Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Magn Reson ; 21(1): 48, 2019 07 29.
Artigo em Inglês | MEDLINE | ID: mdl-31352898

RESUMO

BACKGROUND: The benefit of cardiovascular magnetic resonance Imaging (CMR) in assessing occupational risk is unknown. Pilots undergo frequent medical assessment for occult disease, which threatens incapacitation or distraction during flight. ECG and examination anomalies often lead to lengthy restriction, pending full investigation. CMR provides a sensitive, specific assessment of cardiac anatomy, tissue characterisation, perfusion defects and myocardial viability. We sought to determine if CMR, when added to standard care, would alter occupational outcome. METHODS: A retrospective review was conducted of all personnel attending the RAF Aviation Medicine Consultation Service (AMCS) for assessment of a cardiac anomaly, over a 2-year period. Those undergoing standard of care (history, examination, exercise ECG, 24 h-Holter and transthoracic echocardiography), and those undergoing a CMR in addition, were identified. The influence of CMR upon the final decision regarding flying restriction was determined by comparing the diagnosis reached with standard of care plus CMR vs. standard of care alone. RESULTS: Of the ~ 8000 UK military aircrew, 558 personnel were seen for cardiovascular assessment. Fifty-two underwent CMR. A normal TTE did not reliably exclude abnormalities subsequently detected by CMR. Addition of CMR resulted in an upgraded occupational status in 62% of those investigated, with 37% returning to unrestricted duties. Only 8% of referrals were undiagnosed following CMR. All these were cases of borderline chamber dilatation and reduction in systolic function in whom diagnostic uncertainty remained between physiological exercise adaptation and early cardiomyopathy. CONCLUSIONS: CMR increases the likelihood of a definitive diagnosis and of return to flying. This study supports early use of CMR in occupational assessment for high-hazard occupations.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Militares , Saúde Ocupacional , Pilotos , Adulto , Doenças Cardiovasculares/patologia , Doenças Cardiovasculares/fisiopatologia , Eletrocardiografia , Feminino , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Retorno ao Trabalho , Medição de Risco , Fatores de Risco , Fatores de Tempo , Fluxo de Trabalho , Adulto Jovem
2.
Eur Radiol ; 26(5): 1493-502, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26253256

RESUMO

OBJECTIVES: We validate a novel CT coronary angiography (CCTA) coronary calcium scoring system. METHODS: Calcium was quantified on CCTA images using a new patient-specific attenuation threshold: mean + 2SD of intra-coronary contrast density (HU). Using 335 patient data sets a conversion factor (CF) for predicting CACS from CCTA scores (CCTAS) was derived and validated in a separate cohort (n = 168). Bland-Altman analysis and weighted kappa for MESA centiles and Agatston risk groupings were calculated. RESULTS: Multivariable linear regression yielded a CF: CACS = (1.185 × CCTAS) + (0.002 × CCTAS × attenuation threshold). When applied to CCTA data sets there was excellent correlation (r = 0.95; p < 0.0001) and agreement (mean difference -10.4 [95% limits of agreement -258.9 to 238.1]) with traditional calcium scores. Agreement was better for calcium scores below 500; however, MESA percentile agreement was better for high risk patients. Risk stratification was excellent (Agatston groups k = 0.88 and MESA centiles k = 0.91). Eliminating the dedicated CACS scan decreased patient radiation exposure by approximately one-third. CONCLUSION: CCTA calcium scores can accurately predict CACS using a simple, individualized, semiautomated approach reducing acquisition time and radiation exposure when evaluating patients for CAD. This method is not affected by the ROI location, imaging protocol, or tube voltage strengthening its clinical applicability. KEY POINTS: • Coronary calcium scores can be reliably determined on contrast-enhanced cardiac CT • This score can accurately risk stratify patients • Elimination of a dedicated calcium scan reduces patient radiation by a third.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem , Idoso , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores/métodos , Variações Dependentes do Observador , Doses de Radiação , Reprodutibilidade dos Testes
3.
Artigo em Inglês | MEDLINE | ID: mdl-38795237

RESUMO

Transcatheter aortic valve implantation (TAVI) with commissural alignment aims to limit the risk of coronary occlusion and maintain good coronary access. However, due to coronary origin eccentricity within the coronary cusp, coronary-commissural overlap (CCO) may still occur. TAVI using coronary alignment, rather than commissural alignment, may further improve coronary access. To compare rates of CCO after TAVI using commissural versus coronary alignment methodology. Cardiac CT scans from 102 patients with severe (tricuspid) aortic stenosis referred for TAVI were analysed. Native cusp asymmetry and coronary eccentricity were defined and used to simulate TAVI using commissural versus coronary alignment. Rates of optimal coronary alignment (< 10° from cusp centre) and severe misalignment (< 15° from coronary-commissural overlap) were compared. Additionally, the impact of valve misalignment during implantation was assessed. The native right coronary artery (RCA) origin was 15.8° (9.5 to 24°) closer to the right coronary cusp/non-coronary cusp (RCC-NCC) commissure than the centre of the right coronary cusp. The native left coronary artery (LCA) origin was 4.5° (0 to 11.5°) closer to the left coronary cusp/non-coronary cusp (LCC-NCC) commissure than the centre of the left coronary cusp (p < 0.01). Compared to commissural alignment, coronary alignment doubled the proportion of optimally-aligned RCAs (62/102 [60.8%] vs. 31/102 [30.4%]; p < 0.001), without a significant change in optimal LCA alignment (62/102 [60.8% vs. 74/102 [72.6%]; p = 0.07). There were no cases of severe misalignment with either strategy. Simulating 15° of valve misalignment resulted in severe RCA compromise risk in 7/102 (6.9%) of commissural alignment cases, compared to none using coronary alignment. Fluoroscopic projection was similar with both approaches. Coronary alignment resulted in a 2-fold increase of optimal TAVI positioning relative to the RCA ostium when compared to commissural alignment without impacting the LCA. Use of coronary alignment rather than commissural alignment may improve coronary access after TAVI and is less sensitive to valve rotational error, particularly for the right coronary artery.

4.
Eur Heart J Case Rep ; 7(2): ytad016, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36819886

RESUMO

Background: Guidelines support upgrade to cardiac resynchronization therapy (CRT) through His-bundle pacing (HBP) in pacing-induced cardiomyopathy and moderate left ventricular systolic dysfunction (LVSD). Lead-related venous occlusion can represent an obstacle to upgrade procedures. We describe a technique to overcome venous occlusion through direct puncture of a collateral vein facilitating upgrade to HBP. Case summary: An 84-year-old man with a right ventricular (RV) pacemaker was referred with New York Heart Association (NYHA) Class III breathlessness secondary to moderate LVSD (left ventricular ejection fraction [LVEF] 45%). Device interrogation revealed 100% RV pacing and AV-dyssynchrony. To optimize atrioventricular (AV) and interventricular (VV) synchrony a CRT upgrade with HBP was planned. Venography revealed an occluded left subclavian vein which was probed in a retrograde manner using a 6F MPA catheter from right femoral venous access. We were able to direct the catheter distal to the left brachio-cephalic vein and define the occlusion using contrast. A collateral branch was identified, a J-wire was left in this branch and venous access was secured at this medial subclavian site using the Seldinger technique. A right atrial lead was deployed and 69 cm ISI-1 His lead was deployed via a C315 sheath at the His-bundle. The resulted in non-selective HBP (Stim-QRS end 146 ms). There were no procedural complications. Two months later both symptoms and LV function (LVEF 55%) improved. Discussion: Lead-related venous occlusion occurs frequently and can be probed in a retrograde manner from femoral venous access using contrast, facilitating direct percutaneous puncture of collateral venous branches to allow upgrade to CRT via HBP.

5.
J Invasive Cardiol ; 35(1): E37-E45, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36495540

RESUMO

INTRODUCTION: Right bundle-branch block (RBBB) is a strong predictor of the development of high-grade AV block (AVB) after TAVI. AIMS: To assess mortality, length-of-hospital stay, and cost in patients with RBBB undergoing TAVI according to whether or not they had preprocedural permanent pacemaker (PPM) implantation. METHODS AND RESULTS: A total of 121 patients with RBBB who underwent TAVI between 2009-2021 were included. A total of 41 patients (33.9%) received a prophylactic PPM by clinical preference and 45/80 patients (56%) received PPM after TAVI. Baseline characteristics were balanced. Mortality was similar at 5 years, with death in 17 patients (41.4%) in the prophylactic PPM group vs 27 (33.8%) in the no prophylactic PPM group (adjusted hazard ratio [HR], 1.27; 95% confidence interval [CI], 0.69-2.33; P=.44). Median survival for the prophylactic PPM (4.2 years), post TAVI PPM (4.5 years) and no pacemaker (4.7 years) groups was similar. Sixteen deaths (35.6%) occurred in those receiving PPM after TAVI and 11 deaths (31.4%) occurred in those not receiving PPM (HR, 0.95; 95% CI, 0.43-2.09; P=.90). Thirty-day all-cause mortality was similar. Compared with post-TAVI PPM, prophylactic PPM reduced hospital length of stay (4.3 ± 4.5 days vs 2.5 ± 1.6 days, respectively; P=.02). For the highest and lowest complication and comorbidity scores, prophylactic PPM resulted in cost savings of £297.32 (-2.9%) and excess cost of £423.89 (+5.6%), respectively. There were no major pacing-related complications. CONCLUSIONS: More than half of patients with RBBB undergoing TAVI require PPM shortly after their valve implant. A prophylactic pacing strategy is safe, reduces length of hospital stay, and is cost effective in the United Kingdom.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bloqueio Atrioventricular/terapia , Marca-Passo Artificial/efeitos adversos , Valva Aórtica/cirurgia , Resultado do Tratamento , Estimulação Cardíaca Artificial , Fatores de Risco
6.
Open Heart ; 4(2): e000636, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29081978

RESUMO

Patent foramen ovale (PFO) closure for cryptogenic stroke remains controversial due to a lack of conclusive randomised controlled data. Many experts feel PFO closure is indicated in selected cases; however, national and international guideline recommendations differ. We surveyed the UK cardiologists, stroke physicians and neurologists, seeking to determine specialist interpretation of the evidence base, and to gain an insight into the current UK practice. The British Cardiac Society and British Society of Stroke physicians distributed our survey which was performed using an online platform. 120 physicians (70 stroke physicians, 23 neurologists, 27 cardiologists) completed the survey. Most (89%) felt PFO closure should be considered in selected patients. Atrial fibrillation (86.6%), significant carotid stenosis (86.6%), diabetes (38.4%) and hypertension (36.6%) were considered exclusion criteria for cryptogenic stroke diagnosis. More stroke physicians than cardiologists considered an age cut-off when considering PFO as the stroke aetiology (70.4%vs 54.5%p=0.04). Anatomical features felt to support PFO closure were aneurysmal septum (89.6%), shunt size (73.6%), prominent Eustachian valve (16%). 60% discuss patients in multidisciplinary meetings prior to PFO closure, with more cardiologists than stroke physicians/neurologists favouring this approach (76.9% vs 54.8%; p=0.05). After PFO closure, patients receive Clopidogrel (72.3%), aspirin (50%) or anticoagulants (17%). 63.2% continue therapy for a limited period after PFO closure, while 34% prefer life-long therapy (14.8% cardiologists vs 40.5% non-cardiologists; p=0.02). While experts support selective PFO closure in cryptogenic stroke, current practice remains variable with significant differences in perceptions of cardiologists and neurologists/stroke physicians.

7.
J Thorac Imaging ; 31(3): 177-82, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27007667

RESUMO

PURPOSE: We evaluated a high-pitch, non-electrocardiogram-gated cardiac computed tomographic protocol, designed to image both cardiac and extracardiac structures, including coronary arteries, in a neonatal population (less than 1 year old) that was referred for congenital heart disease assessment and compared it with an optimized standard-pitch protocol in an equivalent cohort. MATERIALS AND METHODS: Twenty-nine high-pitch scans were compared with 31 age-matched, sex-matched, and weight-matched standard-pitch, dosimetrically equivalent scans. The visualization and subjective quality of both cardiac and extracardiac structures were scored by consensus between 2 trained blinded observers. Image noise, signal-to-noise and contrast-to-noise ratios, and radiation doses were also compared. RESULTS: The high-pitch protocol better demonstrated the pulmonary veins (P=0.03) and all coronary segments (all P<0.05), except the distal right coronary artery (P=0.10), with no significant difference in the visualization of the remaining cardiac or extracardiac structures. Both contrast-to-noise and signal-to-noise ratios improved due to greater vessel opacity, with significantly fewer streak (P<0.01) and motion (P<0.01) artifacts. Image noise and computed tomographic dose index were comparable across the 2 techniques; however, the high-pitch acquisition resulted in a small, but statistically significant, increase in dose-length product [13.0 mGy.cm (9.0 to 17.3) vs. 11.0 mGy.cm (9.0 to 13.0), P=0.05] due to greater z-overscanning. CONCLUSIONS: In neonates, a high-pitch protocol improves coronary artery and pulmonary vein delineation compared with the standard-pitch protocol, allowing a more comprehensive assessment of cardiovascular anatomy while obviating the need for either patient sedation or heart rate control.


Assuntos
Angiografia Coronária/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Coração/diagnóstico por imagem , Humanos , Lactente , Recém-Nascido , Masculino , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
8.
Int J Cardiovasc Imaging ; 32(2): 347-354, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26420491

RESUMO

Assessment of the left atrial appendage (LAA) for thrombus and anatomy is important prior to atrial fibrillation (AF) ablation and LAA exclusion. The use of cardiovascular CT (CCT) to detect LAA thrombus has been limited by the high incidence of pseudothrombus on single-pass studies. We evaluated the diagnostic accuracy of a two-phase protocol incorporating a limited low-dose delayed contrast-enhanced examination of the LAA, compared with a single-pass study for LAA morphological assessment, and transesophageal echocardiography (TEE) for the exclusion of thrombus. Consecutive patients (n = 122) undergoing left atrial interventions for AF were assessed. All had a two-phase CCT protocol (first-past scan plus a limited, 60-s delayed scan of the LAA) and TEE. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) were calculated for the detection of true thrombus on first-pass and delayed scans, using TEE as the gold standard. Overall, 20/122 (16.4 %) patients had filling defects on the first-pass study. All affected the full delineation of the LAA morphology; 17/20 (85 %) were confirmed as pseudo-filling defects. Three (15 %) were seen on late-pass and confirmed as true thrombi on TEE; a significant improvement in diagnostic performance relative to a single-pass scan (McNemar Chi-square 17, p < 0.001). The sensitivity, specificity, diagnostic accuracy, PPV and NPV was 100, 85.7, 86.1, 15.0 and 100 % respectively for first-pass scans, and 100 % for all parameters for the delayed scans. The median (range) additional radiation dose for the delayed scan was 0.4 (0.2-0.6) mSv. A low-dose delayed scan significantly improves the identification of true LAA anatomy and thrombus in patients undergoing LA intervention.


Assuntos
Apêndice Atrial/anatomia & histologia , Apêndice Atrial/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
9.
Int J Cardiovasc Imaging ; 30(6): 1135-43, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24798126

RESUMO

We validate a method of calcium scoring on CT coronary angiography (CTCA) and propose an algorithm for the assessment of patients with stable chest pain. 503 consecutive patients undergoing coronary artery calcium score (CACS) and CTCA were included. A 0.1 cm2 region of interest was used to determine the mean contrast density on CTCA images either in the left main stem (LM) or right coronary artery. Axial 3 mm CTCA images were scored for calcium using conventional software with a modified threshold: mean LM contrast density (HU) + 2SD. A conversion factor (CF) for predicting CACS from raw CTCA scores (rCTCAS) was determined using a multivariable regression model adjusted for model over-optimism (1,000 bootstrap samples). Accuracy of this method was determined using weighted kappa for NICE recommended CACS groupings (0, 1-400, >400) and Bland-Altman analysis for absolute score. With the CF applied: CACS = (1.183 × rCTCAS) + (0.002 × rCTCAS × threshold), there was excellent agreement between methods for absolute score (mean difference 5.44 [95% limits of agreement -207.0 to 217.8]). The method discriminated between high (>400) and low risk (<400) calcium scores with a sensitivity and specificity of 85 and 99%, and a PPV and NPV of 92 and 98%, respectively, and led to a significant reduction in radiation exposure (6.9 [5.1-10.2] vs. 5.2 [6.3-8.7] mSv; p < 0.0001). Our proposed method allows a comprehensive assessment of coronary artery pathology through the use of an individualised, semi-automated approach. If incorporated into stable chest pain guidelines the need for further functional testing or invasive angiography could be determined from CTCA alone, supporting a change to the current guidelines.


Assuntos
Algoritmos , Angina Estável/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Interpretação de Imagem Radiográfica Assistida por Computador , Calcificação Vascular/diagnóstico por imagem , Idoso , Angina Estável/etiologia , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Software , Calcificação Vascular/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA