Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
2.
J Card Surg ; 37(12): 4269-4277, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36285550

RESUMO

BACKGROUND: Degenerative mitral valve (MV) regurgitation (DMR) shows significative mitral annulus (MA) alterations; mitral valve repair (MVR) seeks to restore annular geometry and function, and the current use of flexible band seams to respect most annular mobility reducing parietal stress. Parameters of MV geometry obtained by 3D transesophageal echocardiography (3D-TTE) analysis are crucial for surgical planning and postoperative success. The aim of this study was to assess, by means of a dedicated software, the variations of MA geometry and function in patients affected by DMR compared to controls and after MVR with flexible band. METHODS: We enrolled 32 patients (cases) with severe DMR who underwent MVR using flexible band; we compare this group with 20 controls. The TEE with 3D MV images acquisition was performed in both groups and then analyzed in postprocessing by using a dedicated software. RESULTS: There were no anthropometrics differences between cases and controls, both presented normal left ventricular ejection fraction. DMR group showed a significant increase of annulus dimensional parameters (p = .001) and alteration of nonplanarity comparing to controls (p < .05). The annuloplasty with flexible band induces a considerable reduction of MV dimensions comparing to preoperative data and restores physiological mobility and nonplanarity. There were no statistical differences between postoperative DMR and controls data, except for nonplanarity parameters (p ~.05), maybe influenced by hemodynamic settings. CONCLUSIONS: MVR with annuloplasty using flexible band appears able to reinstate a more physiological anatomic conformation of the MA, without compromising its dynamic properties.


Assuntos
Ecocardiografia Tridimensional , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Anuloplastia da Valva Mitral/métodos
3.
Echocardiography ; 37(6): 930-934, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32453473

RESUMO

Subvalvular aortic stenosis (SAS) can be either a fixed stenosis resulting from subaortic anatomical obstacle or a dynamic stenosis because of hypertrophic cardiomyopathy. Here, we report a patient with a rare subaortic circumferential fibromuscular tunnel who became unusually symptomatic in her sixth decade of life. Transthoracic and mostly transesophageal echocardiography with 3D application is the preferred diagnostic modality. Indications for surgery include symptoms and LVOT gradient of 50 mm Hg. Our purpose is an image focus on this infrequent case.


Assuntos
Estenose Aórtica Subvalvar , Cardiomiopatia Hipertrófica , Ecocardiografia Tridimensional , Idoso , Constrição Patológica , Ecocardiografia , Feminino , Humanos
4.
Echocardiography ; 33(3): 476-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26593682

RESUMO

In the setting of an acute coronary syndrome, the differential diagnosis between a thrombus and a myxoma may be cumbersome. We describe the case of a patient presenting with an acute coronary syndrome associated with an aneurysmatic apical left ventricular myxoma.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Mixoma/diagnóstico por imagem , Diagnóstico Diferencial , Neoplasias Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade
6.
JAMA ; 312(10): 1016-23, 2014 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-25172965

RESUMO

IMPORTANCE: Postpericardiotomy syndrome, postoperative atrial fibrillation (AF), and postoperative effusions may be responsible for increased morbidity and health care costs after cardiac surgery. Postoperative use of colchicine prevented these complications in a single trial. OBJECTIVE: To determine the efficacy and safety of perioperative use of oral colchicine in reducing postpericardiotomy syndrome, postoperative AF, and postoperative pericardial or pleural effusions. DESIGN, SETTING, AND PARTICIPANTS: Investigator-initiated, double-blind, placebo-controlled, randomized clinical trial among 360 consecutive candidates for cardiac surgery enrolled in 11 Italian centers between March 2012 and March 2014. At enrollment, mean age of the trial participants was 67.5 years (SD, 10.6 years), 69% were men, and 36% had planned valvular surgery. Main exclusion criteria were absence of sinus rhythm at enrollment, cardiac transplantation, and contraindications to colchicine. INTERVENTIONS: Patients were randomized to receive placebo (n=180) or colchicine (0.5 mg twice daily in patients ≥70 kg or 0.5 mg once daily in patients <70 kg; n=180) starting between 48 and 72 hours before surgery and continued for 1 month after surgery. MAIN OUTCOMES AND MEASURES: Occurrence of postpericardiotomy syndrome within 3 months; main secondary study end points were postoperative AF and pericardial or pleural effusion. RESULTS: The primary end point of postpericardiotomy syndrome occurred in 35 patients (19.4%) assigned to colchicine and in 53 (29.4%) assigned to placebo (absolute difference, 10.0%; 95% CI, 1.1%-18.7%; number needed to treat = 10). There were no significant differences between the colchicine and placebo groups for the secondary end points of postoperative AF (colchicine, 61 patients [33.9%]; placebo, 75 patients [41.7%]; absolute difference, 7.8%; 95% CI, -2.2% to 17.6%) or postoperative pericardial/pleural effusion (colchicine, 103 patients [57.2%]; placebo, 106 patients [58.9%]; absolute difference, 1.7%; 95% CI, -8.5% to 11.7%), although there was a reduction in postoperative AF in the prespecified on-treatment analysis (placebo, 61/148 patients [41.2%]; colchicine, 38/141 patients [27.0%]; absolute difference, 14.2%; 95% CI, 3.3%-24.7%). Adverse events occurred in 21 patients (11.7%) in the placebo group vs 36 (20.0%) in the colchicine group (absolute difference, 8.3%; 95% CI; 0.76%-15.9%; number needed to harm = 12), but discontinuation rates were similar. No serious adverse events were observed. CONCLUSIONS AND RELEVANCE: Among patients undergoing cardiac surgery, perioperative use of colchicine compared with placebo reduced the incidence of postpericardiotomy syndrome but not of postoperative AF or postoperative pericardial/pleural effusion. The increased risk of gastrointestinal adverse effects reduced the potential benefits of colchicine in this setting. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01552187.


Assuntos
Fibrilação Atrial/prevenção & controle , Procedimentos Cirúrgicos Cardíacos , Colchicina/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Síndrome Pós-Pericardiotomia/prevenção & controle , Moduladores de Tubulina/uso terapêutico , Idoso , Colchicina/efeitos adversos , Método Duplo-Cego , Feminino , Gastroenteropatias/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico/prevenção & controle , Assistência Perioperatória , Derrame Pleural/prevenção & controle , Moduladores de Tubulina/efeitos adversos
7.
Am J Cardiol ; 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39053724

RESUMO

Coronary allograft vasculopathy (CAV) is a leading cause of morbidity and mortality after heart transplantation. CAV is often diagnosed in later stages or during routine screening in asymptomatic subjects. Myocardial work (MW), calculated using left ventricular global longitudinal strain (LV-GLS) and systemic blood pressure, may be associated with the presence of CAV and outperform conventional echocardiographic parameters. In this retrospective observational study, heart transplant recipients who underwent regular follow-up at our institution between May 2022 and September 2023 were enrolled. All included patients underwent speckle-tracking echocardiography, including MW indexes. CAV was classified according to invasive coronary angiography or computed tomography performed within 12 months of index echocardiography. We collected all available clinical and echocardiographic parameters and evaluated the potential association with CAV. CAV was detected in 29 of 93 patients (31%) (CAV+). Of the MW indexes, the mean global work efficiency (GWE) was 90 ± 6% and was significantly lower in CAV+ than CAV- subjects (86 ± 7% vs 91 ± 4%, p <0.001). GWE (OR 0.86, CI 0.77 to 0.94, p = 0.002), E/e' ratio (OR 1.27, CI 1.08 to 1.52, p = 0.006), and left ventricular ejection fraction (OR 0.90; CI 0.81 to 0.98, p = 0.017) were independently associated with the presence of CAV. GWE (GWE vs LV-GLS, delta area under the curve 0.154, p = 0.047) and the proposed model (GWE+E/e' vs LV-GLS, delta area under the curve 0.198, p = 0.004) were significantly superior in stratifying the incremental risk for CAV compared with LV-GLS. In conclusion, GWE was observed to be independently associated with the presence of CAV. MW could represent a novel noninvasive screening method for CAV in heart transplant recipients. Larger and prospective studies are needed to confirm this hypothesis.

8.
Monaldi Arch Chest Dis ; 80(3): 126-32, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24818319

RESUMO

OBJECTIVE: Aim of this study was to compare the hemodynamic profiles of 2 aortic valve bioprostheses: the Carpentier Edwards Perimount Magna (CEPM) valve and the Trifecta valve. METHODS: 100 patients who underwent AVR for severe symptomatic AS between September 2011 and October 2012 were analyzed by means of standard trans-thoracic Doppler-echocardiography. RESULTS: Mean and peak gradients were significantly lower for the 21 mm Trifecta vs CEPM (11 +/- 4 vs 15 +/- 4 mmHg, and 20 +/- 6 vs 26 +/- 7 mmHg, respectively; all p < 0.05) and the 23 mm Trifecta vs CEPM (8 +/- 2 vs 14 +/- 4 mmHg, and 17 +/- 6 vs 25 +/- 9 mmHg; all p < 0.05). Effective orifice area tended to be slightly higher for the Trifecta valve. CONCLUSION: The new bioprosthetic valve Trifecta has an excellent hemodynamic profile, and lower trans-prosthesic gradients when compared to CEPM valve.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Ecocardiografia Doppler , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Desenho de Prótese , Resultado do Tratamento
9.
Minerva Cardiol Angiol ; 71(3): 324-332, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35332751

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is emerging as an appealing management strategy for patients with severe aortic stenosis at intermediate, high or exceedingly high risk, but its risk-benefit profile in younger patients is less certain. We aimed to explore the outlook of patients aged 70 years or less and undergoing TAVI at 2 high-volume Italian institutions. METHODS: We retrospectively collected baseline, imaging, procedural and outcome features of patients with age ≤70 years in whom TAVI was attempted at participating centers between 2012 and 2021. Non-parametric tests and bootstrap resampling were used for inferential purposes. RESULTS: A total of 39 patients were included, out of >3000 screened with heart team involvement and >1500 receiving TAVI. Most common or relevant indications for TAVI reduced life expectancy (e.g. cardiogenic shock or severe left ventricular systolic dysfunction), chronic obstructive pulmonary disease, morbid obesity, active or recent extra-cardiac cancer, porcelain aorta, neurologic disability, cirrhosis, or prior surgical aortic valve replacement, as well as extreme cachexia, and Hutchinson-Gilford progeria. At least two contemporary high-risk features were present in most cases. Transapical access was used in 5 (12.8%) cases, and a sheathless approach in 15 (38.5%). A variety of devices were used, including both balloon- and self-expandable devices. Clinical outcomes were satisfactory, despite the high-risk profile, at both short- and mid-term, with no in-hospital death, and 5.1% (95% confidence interval 0-12.8%) mortality at a median follow-up of 15 months (minimum 1; maximum 85). Notably, no case of significant valve deterioration requiring reintervention occurred. CONCLUSIONS: In carefully selected patients with 70 years or less of age and prohibitive risk for surgery or reduced life expectancy, TAVI represents a safe option with a favorable mid-term survival and low rate of adverse events.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia
10.
Cardiovasc Ultrasound ; 10: 44, 2012 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-23150924

RESUMO

BACKGROUND: Cardiac allograft vasculopathy (CAV) is a major late complication in cardiac transplant recipients and has a relevant impact on outcome of these patients. AIMS OF THIS STUDY: to compare, in cardiac transplant recipients patients, the diagnostic value of pressure/volume relationship (ESPVR) during dobutamine stress echocardiography (DSE) for coronary artery disease, assessed by Multislice Computed Tomography (MSCT), and by coronary angiography (CA). We also analyzed any possible relationship between ESPVR and the Health Related Quality of Life of the patients (HRQoL), evaluated by SF-36 questionnaire. METHODS: 25 consecutive patients underwent DSE within 24 hours after MSCT coronary angiogram and then they underwent CA. The HRQoL questionnaire was administered to the patients in the settings of DSE. They were followed-up for 6 months. RESULTS: DSE has a sensitivity in detecting CAV of 67%, specificity of 95%, positive predictive value of 67% and negative predictive value of 95%; DSE with ESPVR has a sensitivity of 100%, specificity of 95%, positive predictive value of 75%, negative predictive value of 100%; MSCT has a sensitivity of 100%; specificity of 82%; positive predictive value of 43%; negative predictive value of 100%. Htx recipients with a flat-biphasic ESPVR, although asymptomatic, perceived a worst HRQoL compared with the up-sloping ESPVR population, and this is statistically significant for the general health (p 0.0004), the vitality (p 0.0013) and the mental health (p 0.021) SF-36 subscale. CONCLUSIONS: Evaluation with DSE and ESPVR is accurate in the clinical control of heart transplant recipients reserving invasive evaluation only for patients with abnormal contractility indexes.


Assuntos
Ecocardiografia sob Estresse , Cardiopatias/diagnóstico por imagem , Transplante de Coração , Qualidade de Vida , Idoso , Pressão Sanguínea/fisiologia , Débito Cardíaco/fisiologia , Estudos de Coortes , Angiografia Coronária , Feminino , Cardiopatias/fisiopatologia , Cardiopatias/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Função Ventricular Esquerda/fisiologia
12.
Eur Heart J Acute Cardiovasc Care ; 11(8): 629-639, 2022 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-35866303

RESUMO

AIMS: Pulmonary artery pulsatility index (PAPi) is an indicator of right ventricular (RV) function and an independent predictor of right ventricular failure (RVF) following left ventricular assist device (LVAD) implantation. Administration of vasodilator challenge during right heart catheterization (RHC) could reduce RV workload allowing a better assessment of its functional reserve. METHODS AND RESULTS: Patients undergoing LVAD implantation at our Institution between May 2013 and August 2021 were enrolled. Only patients who had undergone RHC and vasodilator challenge with sodium nitroprusside were analyzed. We collected all available clinical, instrumental, and haemodynamic parameters, at baseline and after nitroprusside infusion and evaluated potential associations with post-LVAD RVF. Of the 54 patients analyzed, 19 (35%) developed RVF after LVAD implantation. Fractional area change (FAC) (OR: 0.647, CI: 0.481-0.871; P = 0.004), pulmonary artery systolic pressure (PASP) (OR: 0.856, CI: 0.761-0.964; P = 0.010), and post-sodium nitroprusside (NTP) PAPi (OR: 0.218, CI: 0.073-0.653; P = 0.006) were independent predictors of post-LVAD RVF. The model combining FAC, PASP, and post-NTP PAPi demonstrated a predictive accuracy of 90.7%. Addition of post-NTP PAPi significantly increased the predictive accuracy of the European Registry for Patients with Mechanical Circulatory Support right-sided heart failure risk score [79.4 vs. 70.4%; area under the curve (AUC): 0.841 vs. 0.724, P = 0.022] and the CRITT score (79.6% vs. 74%; AUC: 0.861 vs. 0.767 P = 0.033). CONCLUSION: Post-NTP PAPi has observed to be an independent predictor of RVF following LVAD implantation. Dynamic assessment of PAPi using a vasodilator challenge may represent a method of testing RV functional reserve in candidates for LVAD implantation. Larger and prospective studies are needed to confirm this hypothesis.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Insuficiência Cardíaca/complicações , Coração Auxiliar/efeitos adversos , Humanos , Nitroprussiato/farmacologia , Estudos Retrospectivos , Vasodilatadores/farmacologia , Vasodilatadores/uso terapêutico , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/etiologia , Função Ventricular Direita
13.
Cardiovasc Ultrasound ; 9: 37, 2011 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-22114985

RESUMO

OBJECTIVES: This study was designed to describe Doppler-echocardiography values of Carpentier-Edwards Perimount Standard (CEPS) and Carpentier-Edwards Perimount Magna (CEPM) aortic prosthetic valves, evaluated by a single, experienced echo-laboratory, early in the postoperative phase. METHODS: Three-hundred-seventy-seven consecutive patients, who had had a CEPS or a CEPM implanted in our Hospital due to aortic stenosis and/or insufficiency, underwent baseline Doppler echocardiography evaluation within 7 days after surgery. Hemodynamic performances of CEPS and CEPM were accurately described, evaluating flow-dependent (transprosthetic velocities and gradients) and flow-independent (effective orifice area, indexed effective orifice area and Doppler velocity index) Doppler-echocardiography parameters. RESULTS: Out of the 377 patients 48.8% were men (n = 184), mean age was 74.63 ± 6.77 years, mean BSA was 1.78 ± 0.18 m2, mean ejection fraction was 57.78 ± 8%. Two-hundred and sixty two CEPS and 115 CEPM were implanted. Comparing size-by-size CEPS with CEPM, both prostheses showed a good hemodynamic profile, with fairly similar values of pressure gradients (PGmax and mean, in mmHg, = 37,18 ± 11.57 and 20.81 ± 7.44 in CEPS n°19 compared to 32,47 ± 7,76 and 17,67 ± 4.63 in CEPM n°19 and progressively lower in higher sized prostheses, having PGmax and mean 15 ± 3,16 and 9.15 ± 1,29 in CEPS n°29 compared to 15,67 ± 1,53 and 9 ± 1 in CEPM n°29) and EOAi (being 0,65 ± 0,33 cm²/m² in CEPS n°19 compared to 0,77 ± 0,29 cm²/m² in CEPM n°19 and progressively higher in higher sized prostheses, being 1,28 ± 0,59 cm²/m² in CEPS n°29 compared to 1,07 ± 0,18 cm²/m² in CEPM n°29), the latter resulting, however, basically less flow obstructive. CONCLUSIONS: Our data confirm the good hemodynamic performance of both aortic bioprostheses and the more favourable hemodynamic profile of CEPM compared to CEPS, pointing out the need to perform routinely an accurate baseline Doppler-echocardiography evaluation early after surgery to allow an adequate interpretation of data at follow-up.


Assuntos
Insuficiência da Valva Aórtica/embriologia , Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia Doppler/estatística & dados numéricos , Próteses Valvulares Cardíacas/estatística & dados numéricos , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Diagnóstico Precoce , Análise de Falha de Equipamento , Feminino , Humanos , Itália/epidemiologia , Masculino , Prevalência , Desenho de Prótese , Medição de Risco , Fatores de Risco , Resultado do Tratamento
16.
Am J Cardiovasc Dis ; 10(2): 131-135, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32685271

RESUMO

BACKGROUND: The pharmacological effects of cocaine have been associated with different types of cardiac dysrhythmias and with Brugada pattern on the ECG, but currently only type 1 pattern has been described. We report a case of a transient Brugada type 2 pattern in a young cocaine abuser. METHOD: We report the clinical presentation of a 32-year-old male with a history of cocaine abuse. RESULT: The treatment and the resolution of the acute phase have been described; moreover we discuss the pathophysiology of the Brugada phenocopy in this specificclinical setting. CONCLUSION: The clinical impact of our case report underscores the necessity of prompt physician awareness of any ECG abnormality besides myocardial infarction in patients with cocaine abuse, such as any Brugada pattern, which could lead to ominous ventricular arrhythmias.

18.
Cureus ; 11(12): e6387, 2019 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-31886099

RESUMO

Metastatic spread to the heart from neoplasms is very rare, often silent and rarely gains clinical attention. Usually, it correlates with widespread metastatic disease and is suggestive of a poor prognosis. Most cardiac metastases (CM) are detected following post-mortem studies with only a handful reported antemortemly. Here, we report a case of an asymptomatic cardiac metastasis from esophageal carcinoma and a review of the literature. In late July 2014, a 73-year-old woman diagnosed with locally advanced esophageal squamous cell carcinoma was admitted to our institution. Cardiothoracic metastases were not detected at basal computed tomography (CT) scan. The patient was submitted to concurrent cisplatin and radiotherapy. Just before surgery, a CT scan revealed two metastases in the right ventricle and in the interventricular septum. Transthoracic echocardiography and an endomyocardial biopsy confirmed the diagnosis of squamous cell carcinoma from the esophageal origin. In February 2015, chemotherapy was started, but after two courses of gemcitabine, a pulmonary embolism and then a congestive heart failure caused death of the patient on April 2015. Reviewing the literature, 14 cases with an antemortem diagnosis of CM from esophageal cancer were reported. Our patient should be the fifteenth case with an uncommon presentation without symptoms or signs in the diagnosis. Our case highlights that patients should be evaluated using echocardiography for CM, even if asymptomatic.

19.
Braz J Cardiovasc Surg ; 33(1): 99-103, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29617508

RESUMO

Penetrating cardiac trauma has been increasing in clinical experience and is joined to important morbidity and mortality. A case of a 38-year-old female with history of postpartum depression was reported, admitted to our department for cardiac tamponade due to penetrating self-inflicted multiple stab wound of the chest complicated by rupture of anterior left ventricular wall and traumatic ventricular septal defect. Following the unstable hemodynamic instability, a combined therapeutic strategy was chosen: surgery and transcatheter implantation to correct free wall ventricle damage and traumatic ventricular septal defect, respectively.


Assuntos
Tamponamento Cardíaco/etiologia , Traumatismos Cardíacos/etiologia , Ferimentos Penetrantes/complicações , Adulto , Tamponamento Cardíaco/cirurgia , Angiografia Coronária , Ecocardiografia , Traumatismos Cardíacos/cirurgia , Humanos , Masculino , Equipe de Assistência ao Paciente , Comportamento Autodestrutivo/complicações , Ferimentos Penetrantes/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA