Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Laryngoscope ; 134(11): 4691-4696, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39166732

RESUMO

OBJECTIVE: The short T2 nature of cortical bone causes it to appear similar to air on MR, forcing clinicians to rely on computed tomography imaging, with its attendant ionizing radiation exposure, to define temporal bone structures. Through the use of novel MR sequences with ultra-short echo times (UTE), short T2 structures are now able to be visualized, allowing for improved understanding of anatomical relationships. METHODS: Eight patients (50% female) undergoing MR imaging of the skull base for diagnostic purposes (62.5% for vestibular schwannoma surveillance) at a tertiary care center were enrolled to evaluate the safety and efficacy of UTE imaging. CT scans were completed in 37.5% of the patients as part of their workup and used for comparison purposes. The repetition time, short echo time, and long echo time for the UTE sequence were 11, 0.032, and 2.2 msec, respectively. RESULTS: The protocol added 6 min to the total scanning time, and all patients tolerated the sequence without issue. The ossicles, mastoid air cells, antrum, and epitympanum were able to be seen and had a high Dice similarity coefficient when compared to CT (>0.5). UTE allowed for clear delineation of all segments of the facial nerve with a signal-to-noise ratio of 35 (although the BRAVO sequences had a superior ratio of 140). Vestibular schwannomas were able to be distinguished from normal brain parenchyma. CONCLUSIONS: UTE is safe and effective for visualizing anatomic structures not normally seen on traditional MRI, potentially allowing for improved surgical planning in patients. LEVEL OF EVIDENCE: 3 Laryngoscope, 134:4691-4696, 2024.


Assuntos
Imageamento por Ressonância Magnética , Neuroma Acústico , Osso Temporal , Tomografia Computadorizada por Raios X , Humanos , Osso Temporal/diagnóstico por imagem , Feminino , Masculino , Imageamento por Ressonância Magnética/métodos , Neuroma Acústico/diagnóstico por imagem , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Base do Crânio/diagnóstico por imagem
2.
Hear Res ; 71(1-2): 12-22, 1993 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8113130

RESUMO

This study addressed the hypotheses that the growth of the level of distortion product otoacoustic emissions (LDP) with primary-tone level reflects the behavior of a third-order nonlinear polynomial system, and that two sources exist for these distortion products. The results indicated that the 2f1-f2 otoacoustic emission in humans can be measured over a much larger stimulus range than reported previously, even for stimuli (L1 = L2) as low as 10 dB SPL (re 20 microPa). The input/output functions are best described as a straight line with a rate of growth of about 1 dB/dB of stimulus level. For stimulus levels at which metabolically active, nonlinear cochlear processes are in operation, the system does not behave as a simple third-order nonlinear polynomial. Small plateaus and sharp discontinuities or 'notches' can occur in the functions at stimulus levels of approximately 55 dB SPL. These characteristics are consistent with the notion of two separate sources of the LDP, one at low stimulus levels, and one at high levels. An alternative explanation is that the measured otoacoustic emission does not represent only the activity at a single location along the basilar membrane but includes the effects of interactions among similar signals arising from multiple locations, or from the original source via multiple paths.


Assuntos
Cóclea/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Estimulação Acústica , Adolescente , Adulto , Limiar Auditivo , Meato Acústico Externo/inervação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
Laryngoscope ; 99(11): 1151-7, 1989 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2811554

RESUMO

The hearing sensitivity of 9427 railroad train crew members, determined during the first year of a company-wide hearing conservation program, was compared with hearing sensitivity in a control population not exposed to occupational noise. The hearing sensitivity of the trainmen did not differ significantly from that of the control population. Multiple regression analysis, which considered separately the effects of age and years of service, showed significant differences in hearing levels due to age, but no differences in hearing levels due to years of service. Evaluation of the data by risk categories developed by the National Institute for Occupational Safety and Health indicate that this group of trainmen had no risk of occupational noise-induced hearing loss. These analyses, combined with studies of locomotive cab noise, show clearly that trainmen are not typically exposed to hazardous occupational noise.


Assuntos
Perda Auditiva Provocada por Ruído/diagnóstico , Ruído dos Transportes , Ruído , Doenças Profissionais/diagnóstico , Ferrovias , Adulto , Fatores Etários , Idoso , Análise de Variância , Audiometria , Humanos , Masculino , Pessoa de Meia-Idade , Ruído Ocupacional , Análise de Regressão , Fatores de Tempo
4.
Ann Otol Rhinol Laryngol ; 95(4 Pt 1): 415-20, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3740719

RESUMO

Audiometric tests were conducted on 19 subjects with hypophosphatemic bone disease to investigate whether auditory impairment like that reported in affected adults occurs in young patients. No hearing loss or significant auditory findings were noted among the children or young adult patients. However, sensorineural hearing loss of cochlear origin was identified in the three oldest subjects (40 to 58 years), although a history of noise exposure in two of them could explain the observations. The results indicate that if an association exists between hypophosphatemic bone disease and hearing impairment, the auditory signs will not develop until adulthood in treated patients. Additional studies of large populations of affected adults are needed to identify the incidence and mechanism(s) of the auditory system abnormalities and to assess any effect of medical therapy for the metabolic bone disease.


Assuntos
Perda Auditiva Neurossensorial/etiologia , Hipofosfatemia Familiar/complicações , Adolescente , Adulto , Envelhecimento , Audiometria , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade
5.
Otolaryngol Clin North Am ; 24(2): 415-28, 1991 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1857620

RESUMO

Although many patients with hearing loss benefit from medical or surgical intervention, the vast majority have noncorrectable hearing disorders for which rehabilitation through amplification is indicated. There are three goals for the application of hearing aids: (1) to amplify normal conversational speech to levels that are maximally understandable to the patient; (2) to help the patient hear other environmental sounds; and (3) to assist in the educational or habilitative process for those children who sustain hearing loss prior to language and speech development. In addition, there are certain issues that require medical consideration when a wearable device is placed in the ear. This article describes current hearing aid technology; reviews its benefits, limitations, and application for typical patients; discusses the medical aspects of hearing aid fitting; and describes new hearing aid technology on the horizon.


Assuntos
Auxiliares de Audição , Correção de Deficiência Auditiva , Desenho de Equipamento , Humanos , Ciência de Laboratório Médico
6.
Acta Otolaryngol ; 86(1-2): 64-70, 1978.
Artigo em Inglês | MEDLINE | ID: mdl-696297

RESUMO

Previous studies which have measured acoustic-reflex responses to bone-conducted signals have not effectively differentiated reflex responses from artifacts. A convenient method for identifying such artifacts was developed and employed on some acoustic-reflex measures for bone-conducted signals. The findings indicated that artifacts result when a frequently-used acoustic admittance meter (Grason-Stadler 1720B) and a conventional bone vibrator were used to measure reflex responses for tonal and noise-activating signals. It was suggested that the method be employed in future studies which investigate the acoustic reflex in response to bone-conducted signals.


Assuntos
Testes de Impedância Acústica/instrumentação , Limiar Auditivo/fisiologia , Condução Óssea , Reflexo/fisiologia , Estimulação Acústica , Humanos , Ruído , Osso Temporal/fisiologia
7.
Acta Otolaryngol ; 86(5-6): 428-36, 1978.
Artigo em Inglês | MEDLINE | ID: mdl-716865

RESUMO

Tympanometry was performed before and after producing specific lesions in the middle ears of cats. The lesions selected for study included stapes fixation, ossicular discontinuity, and scarred tympanic membranes. Stapes fixation resulted in marked increases in middle ear impedance, easily detected with tympanometry. Ossicular discontinuity resulted in complex tympanometric shapes which were easily accounted for by simple interactions between acoustic resistance and reactance. The complex shapes that occurred in normal and abnormal ears with pressure changing from negative to positive resulted from more complicated interactions. Large surgical incisions in the posterior-superior quadrant of the eardrum were quite visible at otoscopy but could not be detected tympanometrically one month after surgery.


Assuntos
Testes de Impedância Acústica , Orelha Média/lesões , Estimulação Acústica , Animais , Gatos , Cicatriz/fisiopatologia , Otopatias/diagnóstico , Otopatias/fisiopatologia , Orelha Média/fisiopatologia , Pressão , Ruptura , Estribo/lesões , Estribo/fisiopatologia , Membrana Timpânica/lesões , Membrana Timpânica/fisiopatologia
8.
J Rehabil Res Dev ; 24(4): 55-64, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-3430390

RESUMO

Recent progress on the development of an ear-level digital hearing aid is described. The work includes development of a body-wearable digital hearing aid and a computer-based hearing evaluation system that exploits the flexibility afforded by digital signal processing. The prescriptive criteria and fitting procedure used with the digital hearing aid are described briefly. Design considerations in the development of VLSI chips for an ear-level unit are discussed.


Assuntos
Surdez/reabilitação , Auxiliares de Audição , Audiometria/instrumentação , Humanos , Microcomputadores , Processamento de Sinais Assistido por Computador , Software
9.
Ear Hear ; 5(5): 262-7, 1984.
Artigo em Inglês | MEDLINE | ID: mdl-6500195

RESUMO

After a varied history over the past 15 years, basic acoustic immittance measures now include certain physical measures and certain physiological measures. This article reviews current concepts in the terminology and the instrumentation used for these basic measures. It is designed to provide an understanding of standard acoustic immittance measures and a framework for interpreting the results of special acoustic immittance procedures discussed in this issue.


Assuntos
Testes de Impedância Acústica , Testes de Impedância Acústica/instrumentação , Limiar Auditivo , Meato Acústico Externo/anatomia & histologia , Humanos , Reflexo Acústico , Estapédio/fisiologia , Membrana Timpânica/fisiologia
10.
J Speech Hear Res ; 29(2): 218-26, 1986 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-3724114

RESUMO

Measurements of functional gain were compared first to coupler gain for 57 subjects using one of three hearing aid-earmold combinations and second to probe-tube gain for 12 subjects using in-the-ear hearing aids. The average difference between functional and coupler gain plotted as a function of frequency yielded results that were similar to previous reports, with the greatest effects occurring at 3000 and 4000 Hz. Significant differences were seen among hearing aid-earmold combinations at 3000, 4000, and 6000 Hz. Standard deviations for measurements between 750 and 2000 Hz were less than 5 dB and could be explained by variability of functional gain measures associated with test-retest variability of thresholds measured in a sound field. Below 750 Hz and above 2000 Hz, standard deviations exceeded 5 dB. The greater variability may be explained by differences in earmold venting, acoustic characteristics of the ear canal, and stimuli used to measure functional and coupler gain. Neither room nor hearing-aid noise appeared to affect the results significantly. When functional gain was compared to insertion gain measured with a probe-tube system, the average difference across frequencies was less than 1 dB. The variability of the differences at all frequencies, with the exception of 6000 Hz, was within the range reported for functional gain measurements. It was concluded that functional gain can be accurately estimated using probe-tube measurements.


Assuntos
Auxiliares de Audição/normas , Perda Auditiva Neurossensorial/terapia , Audiometria de Tons Puros , Limiar Auditivo , Perda Auditiva Bilateral/terapia , Humanos
11.
J Speech Hear Res ; 18(3): 435-43, 1975 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1186153

RESUMO

Tympanometry and acoustic reflex threshold data are reported for a series of presumable normal infants ranging in age from 55 to 132 days. In general, tympanograms displayed single peaks between +/- 50 mm H2O. Susceptance tympanograms with a 660-Hz probe frequency were sometimes characterized by monotonically increasing susceptance as ear canal pressure was changed from -200 to +200 mm H2O. Static values of acoustic conductance, susceptance, admittance, resistance, reactance, impedance, and phase angle were computed from tympanograms using the values of ambient and +200 mm H2O (0/+200 procedure) and maximum and minimum tympanometric values (MAX/MIN procedure). Comparison of the data from the two computational procedures suggested that the MAX/MIN procedure produces means and standard deviations of static values which are more manageable for establishing confidence limits with which to evaluate potentially pathological subjects. The MAX/MIN procedure resulted in lower mean values of conductance and susceptance for infant subjects relative to previously reported adult data using a similar computational procedure. Acoustic reflex thresholds were clearly present in all testable infants at coupler sound pressure levels similar to adult data, suggesting that the relations between reflex thresholds and hearing sensitivity demonstrated in adult subjects are similarly applicable to infant subjects. Mild sedation to induce sleep without altering the reflex would make acoustic reflex threshold measurement a useful procedure for screening large numbers of infants.


Assuntos
Orelha Média/fisiologia , Som , Adulto , Complacência (Medida de Distensibilidade) , Transferência de Energia , Humanos , Lactente , Métodos , Reflexo , Estatística como Assunto , Membrana Timpânica/fisiologia
12.
Ear Hear ; 8(5 Suppl): 109S-118S, 1987 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-3678649

RESUMO

Speech audibility may be defined as that proportion of a speech spectrum which is above a person's threshold. To optimize speech audibility with a hearing aid, several measures are needed. These include quantification of a speech spectrum, measures of hearing sensitivity, and measures of the "real ear" gain of the hearing aid. Some procedural factors must be considered to obtain adequate measures in a typical clinical setting. Those considered here are: (1) a modified Articulation Index to quantify a speech spectrum, (2) specification of hearing sensitivity with a narrowband sound field reference where the out-of-band rejection rate of the sound field stimulus is greater than twice the slope of the hearing loss, and (3) use of functional gain (measured directly or estimated using earphone and sound field results provided that the sound field stimulus has the required characteristics for measuring hearing sensitivity in the sound field) as a measure of the real ear gain of the hearing aid. Guidelines are given for the practical measurement of speech audibility in a typical clinical setting. The guidelines are appropriate for all measures of real ear gain including those obtained with all probe tube systems.


Assuntos
Auxiliares de Audição/normas , Percepção da Fala , Audiometria de Tons Puros , Audiometria da Fala , Limiar Auditivo , Perda Auditiva Neurossensorial/terapia , Humanos , Percepção da Altura Sonora , Acústica da Fala
13.
J Speech Hear Res ; 20(3): 447-62, 1977 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-904307

RESUMO

To gain a better understanding of tympanometric results that have been difficult to interpret, such as asymmetrical and W-shaped tympanograms, acoustic susceptance and conductance tympanograms were measured from subjects with normal hearing and from subjects with well-defined middle ear pathology. Acoustic reactance, resistance, and impedance were computed and predicted from the measured data. Asymmetrical tympanograms derive in large part from the marked asymmetry in acoustic resistance as a function of ear canal pressure. W-shaped tympanograms result from interactions between reactance and resistance that occur when the two quantities assume similar absolute values or when reactance is mass controlled. A criterion for distinguishing between W-shaped tympanograms that are normal from those that are abnormal is discussed.


Assuntos
Testes de Impedância Acústica , Otopatias/diagnóstico , Ossículos da Orelha/anormalidades , Estimulação Acústica , Atrofia , Meato Acústico Externo/fisiologia , Otopatias/fisiopatologia , Orelha Média/fisiologia , Orelha Média/fisiopatologia , Humanos , Pressão , Membrana Timpânica
14.
Am J Otol ; 13(4): 313-7, 1992 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-1415492

RESUMO

The combined term, sensorineural, is useful because clinical distinction between sensory and neural lesions is often difficult, and because sensory lesions may lead to secondary neural degeneration or, though rarely, a neural lesion may lead to secondary sensory degeneration. The threat of lawsuits for failure to identify treatable neurologic conditions has led to overuse of tests, while fiscal constraints exert pressure to limit expensive diagnostic testing. The purpose of this review of the relation between sensory and neural hearing loss is to provide a practical method to screen for neural lesions using pure-tone thresholds and a single speech discrimination score. The difference between the articulation index and the word recognition score of a patient provides a statistically reliable index of suspicion that may reduce the diagnostic dilemma of neural presbycusis.


Assuntos
Audiometria de Tons Puros , Doenças do Sistema Nervoso/diagnóstico , Presbiacusia/diagnóstico , Testes de Discriminação da Fala , Idoso , Estudos de Coortes , Humanos , Pessoa de Meia-Idade , Espectrografia do Som
15.
J Speech Hear Disord ; 49(3): 254-61, 1984 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-6547756

RESUMO

Audiologic findings in a child who received a single-channel cochlear implant are presented. The measures used were threshold sensitivity to frequency-specific stimuli and results on various subtests from the Test of Auditory Comprehension (Trammel, 1976), the Monosyllable, Trochee, Spondee Test (Erber & Alencewicz, 1976), and the Minimal Auditory Capabilities Battery (Owens, Kessler, Telleen, & Schubert, 1981). The results for the implanted ear indicated uneven change in performance across measures compared to results with conventional amplification prior to receiving the implant. Performance of the implanted ear did not approach performance of the better contralateral ear. Observations by teachers and guardians indicated that there was no apparent change in auditory performance even after the cochlear implant had been worn for 6 months. Overall there was no evidence that the cochlear implant worn for 6 months provided any practical benefit to this child.


Assuntos
Implantes Cocleares , Surdez/reabilitação , Audição , Limiar Auditivo , Criança , Estudos de Avaliação como Assunto , Auxiliares de Audição , Testes Auditivos , Humanos , Masculino , Som , Fatores de Tempo
16.
J Acoust Soc Am ; 64(5): 1406-11, 1978 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-744841

RESUMO

The growth function of the acoustic stapedius reflex was measured in subjects with normal hearing and sensorineural hearing loss of cochlear origin. The effects of age and magnitude of hearing loss were controlled. Activating stimuli were 500, 1000, and 2000 Hz tones and broadband noise. Stapedius muscle activity was inferred from acoustic impedance measures in the contralateral ear. The mean growth functions for tones were essentially linear in log-log plots with the rate of growth equal for the two groups. The mean growth function for the noise signal was curvilinear for the normal hearing groud had linear for the hearing loss group. Comparison of slope functions derived from the fitted data indicated that the rate of reflex growth for the noise signal, over a limited range above reflex threshold, is greater in ears with cochlear lesions than normal ears. For higher level noise signals, however, the rate of reflex growth is similar for normal and pathological ears. The effect of a cochlear lesion on the input-output function of the cochlea for both tonal and noise stimuli is to maintain the rate of reflex growth but shift the function along the intensity axis of a tonal signal and the response axis for a noise signal.


Assuntos
Perda Auditiva Neurossensorial/fisiopatologia , Músculos/fisiologia , Reflexo/fisiologia , Estapédio/fisiologia , Testes de Impedância Acústica , Estimulação Acústica , Adolescente , Adulto , Criança , Cóclea/fisiopatologia , Feminino , Humanos , Masculino
17.
Ear Hear ; 16(2): 159-65, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7789667

RESUMO

Distortion product otoacoustic emissions (DPOAEs) for low stimulus levels (< 60 dB SPL) have been reported in adult humans under ideal conditions. In neonates, DPOAEs have been reported only for high-level stimuli. The purpose of this paper was to determine characteristics of the 2f1-f2 DPOAE for low-level stimuli in neonates and to assess the feasibility of obtaining such measures in a noisy environment. Subjects were 19 premature neonates presumed to have normal hearing based on systematic pneumatic otoscopy measures and evoked auditory brainstem responses. For stimuli centered at 2000 and 6000 Hz and presented over a range of 30 to 75 dB SPL, DPOAEs were measured employing linear time averaging for up to 128 time frames at each level. In quiescent subjects, the level of the noise floor was as low as that reported in cooperative adults under ideal conditions (approximately -30 dB SPL), and the functions were identical. That is, valid measures were obtained for very low stimulus levels (30 dB SPL), the rate of growth approached 1 dB/dB, and identical nonmonotonicities (saturation, plateaus, and notches) were observed as those reported for adults. When the noise floor was elevated due to subject activity, no valid data could be obtained for low-level stimuli even though the DPOAEs were at expected levels for high-level stimuli. These results have important implications for the use of such measures in this population because the DPOAEs associated with the metabolically active nonlinear cochlear processes at low stimulus levels may be contaminated with DPOAEs associated with other processes at high stimulus levels.


Assuntos
Estimulação Acústica , Percepção Auditiva , Recém-Nascido Prematuro , Distorção da Percepção , Audição/fisiologia , Humanos , Recém-Nascido , Ruído
18.
J Speech Hear Res ; 22(1): 179-91, 1979 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-502496

RESUMO

Acoustic conductance and susceptance tympanograms were obtained at 220 and 660 Hz in 34 neonates. The neonates were categorized into three age groups (8-24 hours, 24-60 hours, and 60-96 hours). Single-peaked, double-peaked, and monotonically increasing tympanograms were found. Static values for conductance, susceptance, admittance, resistance, reactance and impedance at the lateral surface of the tympanic membrane were computed from the tympanograms. There were no significant differences in mean static values among the three groups. At 220 Hz, the individual static reactance values were usually smaller than the static resistance values and often assumed a positive sign. At 660 Hz, the individual static reactance values always assumed a negative sign and were approximately equal to the static resistance values. The single- and double-peaked tympanograms apparently were the result of previously identified interactions between static resistance and reactance values. The data were compared to those of infants and adults. Tympanograms at 220 Hz were obtained for 13 of the original subjects at the age of three to four months. The data collected in this group were consistent with those reported in the literature for the same age group.


Assuntos
Testes de Impedância Acústica , Recém-Nascido , Testes de Impedância Acústica/métodos , Adulto , Fatores Etários , Orelha Média/fisiologia , Feminino , Humanos , Lactente , Masculino , Valores de Referência
19.
Ear Hear ; 19(4): 319-28, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9728727

RESUMO

OBJECTIVE: The objective of this study was to identify individual sources of noise and their contribution to the overall noise that influences valid measurement of otoacoustic emissions in neonates. The hypothesis was that careful selection of eliciting signals and signal processing parameters, unique analysis of measured results, and control of certain subject characteristics would allow isolation of these individual noise sources and determine their relative influence. DESIGN: Eliciting signal parameters were optimized and held constant to minimize equipment noise. Analysis of noise floors in relation to signal level was used to identify equipment-related noise associated with changes in signal parameters. Analysis of noise floor distributions was used to determine whether environmental noise entered the measurements via inadequate coupling of the probe to the ear. The acoustic characteristics of the middle ear were varied via subject selection to determine the influence of middle-ear characteristics on noise floor levels. RESULTS: The two sources of noise associated with the measurement equipment need not contribute to the noise floor for biologically relevant otoacoustic emissions measurements (eliciting signal levels between 30 and 75 dB SPL). Of the two pathways identified for environmental noise, the pathway resulting from an inadequate seal between the probe and the ear canal can be eliminated. One of the two sources of noise related to the subject, noise resulting from biologic activity unrelated to the ear can be minimized. However, the remaining factor, the status of the middle ear, has been shown to contribute as much as 6 dB to the overall noise floor. CONCLUSIONS: Careful selection of signal parameters and additional data analyses and procedural variables can isolate or control several sources of noise that influence distortion product otoacoustic emission measurements in neonates. Tight coupling between the probe unit and the external ear canal should be maintained for all measurements. Middle ear abnormalities can increase noise floors up to 6 dB.


Assuntos
Percepção Auditiva/fisiologia , Recém-Nascido/fisiologia , Ruído , Emissões Otoacústicas Espontâneas/fisiologia , Meio Ambiente , Humanos
20.
Scand Audiol ; 22(3): 159-64, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8210955

RESUMO

Parametric variations in the ratio of primary-tone frequencies were explored to optimize the amplitude of the 2f1-f2 distortion product otoacoustic emission for clinical purposes. Ten ears from 5 normally hearing human subjects were examined with primary tones geometrically centred around the standard audiometric frequencies of 0.5, 1, 1.5, 2, 3, 4, 6 and 8 kHz. The distortion product at the frequency 2f1-f2 (f1 < f2) was measured at six probe tone frequency ratios (f2:f1) varying between 1.15 and 1.40 using equal level primaries of 75 dB SPL. The results showed that a single f2:f1 ratio between 1.20 and 1.25 provides a reasonable value for clinical use in that it optimizes the magnitude of the distortion product at 2f1-f2, provides for sufficient resolution in the test frequency range, and is applicable to the standard clinical test frequencies.


Assuntos
Membrana Basilar/fisiologia , Cóclea/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Estimulação Acústica , Acústica , Adulto , Audiometria , Feminino , Células Ciliadas Auditivas/fisiologia , Humanos , Masculino , Reflexo Acústico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA