1.
Environ Int ; 55: 109-18, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23542573

RESUMO

To screen for hormonal activity in water samples, highly sensitive in vitro CALUX bioassays are available which allow detection of estrogenic (ERα), androgenic (AR), progestagenic (PR), and glucocorticoid (GR) activities. This paper presents trigger values for the ERα, AR, PR, and GR CALUX bioassays for agonistic hormonal activities in (drinking) water, which define a level above which human health risk cannot be waived a priori and additional examination of specific endocrine activity may be warranted. The trigger values are based on 1) acceptable or tolerable daily intake (ADI/TDI) values of specific compounds, 2) pharmacokinetic factors defining their bioavailability, 3) estimations of the bioavailability of unknown compounds with equivalent hormonal activity, 4) relative endocrine potencies, and 5) physiological, and drinking water allocation factors. As a result, trigger values of 3.8ng 17ß-estradiol (E2)-equivalents (eq)/L, 11ng dihydrotestosterone (DHT)-eq/L, 21ng dexamethasone (DEX)-eq/L, and 333ng Org2058-eq/L were derived. Benchmark Quotient (BQ) values were derived by dividing hormonal activity in water samples by the derived trigger using the highest concentrations detected in a recent, limited screening of Dutch water samples, and were in the order of (value) AR (0.41)>ERα (0.13)>GR (0.06)>PR (0.04). The application of trigger values derived in the present study can help to judge measured agonistic hormonal activities in water samples using the CALUX bioassays and help to decide whether further examination of specific endocrine activity followed by a subsequent safety evaluation may be warranted, or whether concentrations of such activity are of low priority with respect to health concerns in the human population. For instance, at one specific drinking water production site ERα and AR (but no GR and PR) activities were detected in drinking water, however, these levels are at least a factor 83 smaller than the respective trigger values, and therefore no human health risks are to be expected from hormonal activity in Dutch drinking water from this site.


Assuntos
Água Potável/efeitos adversos , Disruptores Endócrinos/toxicidade , Monitoramento Ambiental/métodos , Poluentes Químicos da Água/toxicidade , Antagonistas de Receptores de Andrógenos , Androgênios/análise , Androgênios/toxicidade , Bioensaio/métodos , Água Potável/química , Disruptores Endócrinos/análise , Receptor alfa de Estrogênio/metabolismo , Glucocorticoides/análise , Glucocorticoides/toxicidade , Humanos , Progestinas/análise , Progestinas/toxicidade , Poluentes Químicos da Água/análise
2.
Sci Total Environ ; 427-428: 308-13, 2012 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-22551937

RESUMO

The chemical water quality is often assessed by screening for a limited set of target chemicals. This 'conventional' target analysis approach inevitably misses chemicals present in the samples. In this study a 'broad' target screening approach for water quality assessment using high resolution and accurate mass spectrometry (HR MS) was applied to detect a wide variety of organic chemicals in 42 groundwater samples. In this approach, both known and unidentified chemicals observed in previous samples define the training set for the analysis of future samples and, additionally, new samples can be used to extend the training set. Nearly 400 chemicals were observed in the samples, of which 82 were known and more than 313 are of unknown identity. The obtained results were interpreted in relation to the source characteristics and land use. Groundwater that was affected by landfills showed the highest total MS response (ion counts) and most individual chemicals and was therefore considered most contaminated. Furthermore, river bank filtrated water was generally more contaminated than phreatic groundwater and groundwater from (semi)confined aquifers was most pristine. Additionally, industrial chemicals were more frequently observed in river bank filtrated water and pesticides were more frequently observed in water originating from rural areas. The 'broad' target screening approach for both known and unidentified chemicals does provide more information on the over-all water quality than 'conventional' target analysis.


Assuntos
Monitoramento Ambiental/métodos , Água Subterrânea/análise , Poluentes Químicos da Água/análise , Qualidade da Água , Cromatografia Líquida , Resíduos Industriais/análise , Espectrometria de Massas , Países Baixos , Compostos Orgânicos/análise , Praguicidas/análise
3.
Environ Sci Technol ; 42(15): 5814-20, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18754514

RESUMO

It is generally known that there are compounds present in the aquatic environment that can disturb endocrine processes, for example via interaction with the endogenous hormone receptors. Most research so far has focused on compounds that bind to the estrogen and/or androgen receptor, but ligands for other hormone receptors might also be present. In this study, a newly completed panel of human cell derived CALUX reporter gene bioassays was utilized to test water extracts for estrogen (ER), as well as androgen (AR), progesterone (PR), and glucocorticoid (GR) receptor mediated transactivation activity. Effluents from industry, hospital, and municipal sewage treatment plants, as well as tap water and different sources of surface water were tested. The CALUX reporter gene panel showed high sensitivity and specificity to known agonists, enabling discrimination between different receptor based endocrine responses present in the aquatic environment. Our results clearly showed the presence of agonistic activity on the ER, as well as on the AR, PR, and GR in the raw and wastewater and surface water extracts. However, no hormone receptor-mediated transactivation was detected in the drinking water or in the blank water. The levels of estrogenic activity were 0.2-0.5 ng E2-equiv/L for surface water and 0.4-1.0 ng E2-equiv/L for municipal effluents, which was consistent with previous studies. Surprisingly, the other hormonal activities were found to be present in similar or much higher levels. Most notably, glucocorticoid-like activity was detected in all samples, at surprisingly high levels ranging from 0.39-1.3 ng Dex-equiv/L in surface water and 11-243 ng Dex-equiv/L in effluents. When regarding the fact that dexamethasone in the GR CALUX bioassay is a factor 12 more potent than the natural hormone cortisol, results expressed as cortisol equivalents would range up to 2900 ng cortisol equiv/L. Further studies are needed to establish the identity of the active compounds and to understand the significance of the level of activities with regard to human and ecotoxicological risks.


Assuntos
Bioensaio/métodos , Receptores de Esteroides/análise , Receptores de Esteroides/metabolismo , Esgotos/química , Ativação Transcricional , Eliminação de Resíduos Líquidos , Poluentes Químicos da Água/análise , Cidades , Dexametasona/análise , Dexametasona/metabolismo , Genes Reporter/genética , Glucocorticoides/análise , Glucocorticoides/metabolismo , Hospitais , Humanos , Hidrocortisona/análise , Hidrocortisona/metabolismo , Resíduos Industriais , Medição de Risco , Poluentes Químicos da Água/metabolismo , Abastecimento de Água/análise