Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Semin Dial ; 37(3): 269-272, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38418259

RESUMO

Stenosis in the anastomotic site or venous limb of an arteriovenous fistula (AVF) is the most frequent cause of AVF failure. Percutaneous angioplasty with a standard or high-pressure balloon is the first-line treatment for AVF stenosis due to its higher technical success rate (90%) and lower complication rate (4%). Almost 20% of stenosis cases are resistant or undilatable by regular-pressure balloon angioplasty due to fibrosis, leading to technical failure or restenosis. Alternative therapies, such as atherectomy devices or cutting balloons, are expensive and difficult to obtain in low-income developing countries. We successfully treated resistant AVF stenosis with a coronary OPN-NC® ultra-high-pressure balloon and produced a good angiographic result with technical success. Coronary hardware is easily available and relatively cheaper compared to dedicated peripheral balloons or devices in our country due to reuse, which can be a boon in such type of cases. According to the standard hospital protocol, Cathlab hardware was reused.


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica , Análise Custo-Benefício , Humanos , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Angioplastia com Balão/economia , Oclusão de Enxerto Vascular/terapia , Oclusão de Enxerto Vascular/economia , Oclusão de Enxerto Vascular/etiologia , Masculino , Diálise Renal , Feminino , Pobreza , Pessoa de Meia-Idade , Constrição Patológica
2.
Clin Neurol Neurosurg ; 237: 108153, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38350174

RESUMO

OBJECTIVES: The geometry of carotid bifurcation is a crucial contributing factor to the localization of atherosclerotic lesions. Currently, studies on carotid bifurcation geometry are limited to the region near to bifurcation. This study aimed to determine the influence of carotid bifurcation geometry on the blood flow using numerical simulations considering magnitude of haemodynamic parameters in the extended regions of carotid artery. METHODS: In the present study, haemodynamic analysis is carried out using the non-Newtonian viscosity model for patient-specific geometries consisting of both Left and Right carotid arteries. A 3D patient-specific geometric model is generated using MIMICS, and a numerical model is created using ANSYS. RESULTS: The results obtained from patient-specific cases are compared. The influence of geometric features such as lumen diameter, bifurcation angle, and tortuosity on the haemodynamics parameters such as velocity, WSS, pressure, Oscillatory Shear Index (OSI), and Time-Averaged Wall Shear Stress (TAWSS) are compared. CONCLUSION: The results demonstrate significant changes in the flow regime due to the geometric shape of the carotid artery. It is observed that the lower value of TAWSS occurs near the bifurcation region and carotid bulb region. In addition, the higher value of the (OSI) is observed in the Internal Carotid Artery (ICA) and the tortuous carotid artery region. However, it is also observed that apart from the bifurcation angle, other factors, such as tortuosity and area ratio, play a significant role in the flow dynamics of the carotid artery.


Assuntos
Artérias Carótidas , Hemodinâmica , Humanos , Artérias Carótidas/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Viscosidade , Velocidade do Fluxo Sanguíneo/fisiologia , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA