Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Phys Med Biol ; 50(4): 655-80, 2005 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-15773626

RESUMO

Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and various voxel sizes with a homogeneous phantom, and assume forward energy transportation only. Simulations with voxel size up to 1 cm show that the CCK algorithm has errors within 0.1% of the maximum gold standard dose. Real dose calculations use a heterogeneous slab phantom, both the 'broad' (5 x 5 cm2) and the 'narrow' (1.2 x 1.2 cm2) tomotherapy beams. Various voxel sizes (0.5 mm, 1 mm, 2 mm, 4 mm and 8 mm) are used for dose calculations. The results show that all three algorithms have negligible difference (0.1%) for the dose calculation in the fine resolution (0.5 mm voxels). But differences become significant when the voxel size increases. As for the DK or CK algorithm in the broad (narrow) beam dose calculation, the dose differences between the 0.5 mm voxels and the voxels up to 8 mm (4 mm) are around 10% (7%) of the maximum dose. As for the broad (narrow) beam dose calculation using the CCK algorithm, the dose differences between the 0.5 mm voxels and the voxels up to 8 mm (4 mm) are around 1% of the maximum dose. Among all three methods, the CCK algorithm is demonstrated to be the most accurate one for multi-resolution dose calculations.


Assuntos
Algoritmos , Modelos Biológicos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografia Computadorizada Espiral/métodos , Simulação por Computador , Humanos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Int J Radiat Oncol Biol Phys ; 56(1): 89-105, 2003 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-12694827

RESUMO

PURPOSE: To review the state of the art in image-guided precision conformal radiotherapy and to describe how helical tomotherapy compares with the image-guided practices being developed for conventional radiotherapy. MATERIALS AND METHODS: Image guidance is beginning to be the fundamental basis for radiotherapy planning, delivery, and verification. Radiotherapy planning requires more precision in the extension and localization of disease. When greater precision is not possible, conformal avoidance methodology may be indicated whereby the margin of disease extension is generous, except where sensitive normal tissues exist. Radiotherapy delivery requires better precision in the definition of treatment volume, on a daily basis if necessary. Helical tomotherapy has been designed to use CT imaging technology to plan, deliver, and verify that the delivery has been carried out as planned. The image-guided processes of helical tomotherapy that enable this goal are described. RESULTS: Examples of the results of helical tomotherapy processes for image-guided intensity-modulated radiotherapy are presented. These processes include megavoltage CT acquisition, automated segmentation of CT images, dose reconstruction using the CT image set, deformable registration of CT images, and reoptimization. CONCLUSIONS: Image-guided precision conformal radiotherapy can be used as a tool to treat the tumor yet spare critical structures. Helical tomotherapy has been designed from the ground up as an integrated image-guided intensity-modulated radiotherapy system and allows new verification processes based on megavoltage CT images to be implemented.


Assuntos
Radioterapia Assistida por Computador , Radioterapia Conformacional/métodos , Radioterapia de Alta Energia/métodos , Tomografia Computadorizada por Raios X , Animais , Cães , Desenho de Equipamento , Humanos , Movimento (Física) , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Lesões por Radiação/prevenção & controle , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X/instrumentação , Ultrassonografia
3.
Med Phys ; 29(11): 2590-605, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12462726

RESUMO

There are many benefits to having an online CT imaging system for radiotherapy, as it helps identify changes in the patient's position and anatomy between the time of planning and treatment. However, many current online CT systems suffer from a limited field-of-view (LFOV) in that collected data do not encompass the patient's complete cross section. Reconstruction of these data sets can quantitatively distort the image values and introduce artifacts. This work explores the use of planning CT data as a priori information for improving these reconstructions. Methods are presented to incorporate this data by aligning the LFOV with the planning images and then merging the data sets in sinogram space. One alignment option is explicit fusion, producing fusion-aligned reprojection (FAR) images. For cases where explicit fusion is not viable, FAR can be implemented using the implicit fusion of normal setup error, referred to as normal-error-aligned reprojection (NEAR). These methods are evaluated for multiday patient images showing both internal and skin-surface anatomical variation. The iterative use of NEAR and FAR is also investigated, as are applications of NEAR and FAR to dose calculations and the compensation of LFOV online MVCT images with kVCT planning images. Results indicate that NEAR and FAR can utilize planning CT data as imperfect a priori information to reduce artifacts and quantitatively improve images. These benefits can also increase the accuracy of dose calculations and be used for augmenting CT images (e.g., MVCT) acquired at different energies than the planning CT.


Assuntos
Algoritmos , Monitorização Intraoperatória/métodos , Neoplasias da Próstata/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Radioterapia Assistida por Computador/métodos , Técnica de Subtração , Humanos , Masculino , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Controle de Qualidade , Intensificação de Imagem Radiográfica/instrumentação , Radiometria/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos
4.
Med Phys ; 31(2): 396-404, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15000626

RESUMO

Helical tomotherapy is a dedicated intensity modulated radiation therapy (IMRT) system with on-board imaging capability (MVCT) and therefore differs from conventional treatment units. Different design goals resulted in some distinctive radiation field characteristics. The most significant differences in the design are the lack of flattening filter, increased shielding of the collimators, treatment and imaging operation modes and narrow fan beam delivery. Radiation characteristics of the helical tomotherapy system, sensitivity studies of various incident electron beam parameters and radiation safety analyses are presented here. It was determined that the photon beam energy spectrum of helical tomotherapy is similar to that of more conventional radiation treatment units. The two operational modes of the system result in different nominal energies of the incident electron beam with approximately 6 MeV and 3.5 MeV in the treatment and imaging modes, respectively. The off-axis mean energy dependence is much lower than in conventional radiotherapy units with less than 5% variation across the field, which is the consequence of the absent flattening filter. For the same reason the transverse profile exhibits the characteristic conical shape resulting in a 2-fold increase of the beam intensity in the center. The radiation leakage outside the field was found to be negligible at less than 0.05% because of the increased shielding of the collimators. At this level the in-field scattering is a dominant source of the radiation outside the field and thus a narrow field treatment does not result in the increased leakage. The sensitivity studies showed increased sensitivity on the incident electron position because of the narrow fan beam delivery and high sensitivity on the incident electron energy, as common to other treatment systems. All in all, it was determined that helical tomotherapy is a system with some unique radiation characteristics, which have been to a large extent optimized for intensity modulated delivery.


Assuntos
Radioterapia Conformacional/métodos , Tomografia/métodos , Elétrons , Humanos , Método de Monte Carlo , Aceleradores de Partículas , Fótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Sensibilidade e Especificidade , Software
5.
Am J Clin Oncol ; 26(1): 70-8, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12576928

RESUMO

The purpose of this study was to determine whether the use of tomotherapy in the treatment of non-small-cell lung cancer (NSCLC) has the potential to reduce radiation dose to normal tissues, in particular, the lungs, esophagus, and spinal cord, as compared with standard radiotherapy. Five patients with anatomically or physiologically inoperable stage III NSCLC were studied, representing a variety of tumor sizes and locations. For each patient, two treatment plans were generated. One was developed using conventional field arrangements (CFA), and the other for tomotherapy. Using dose-volume histogram reduction techniques, including mean normalized dose (NTDmean), V20, and effective uniform dose (EUD), the normal tissue doses for CFA and tomotherapy plans for a given fixed tumor dose were compared. In addition, the maximum tumor doses possible for a given level of mean normalized lung dose were computed and compared for the CFA and tomotherapy plans. The gross tumor volumes in the five patients studied ranged from 13.5 to 87.1 cm. The tumor dose distributions, determined by EUD and minimum dose, were similar for both CFA and tomotherapy plans, as intended. In all cases, the NTDmean of both lungs was significantly reduced using tomotherapy planning (range: 10-53% reduction, mean: 31%). The volume of lung receiving more than 20 Gy was also reduced in all cases using tomotherapy (range: 17-37% reduction, mean: 22%). For a constant lung NTDmean, it is shown that it should be possible to increase tumor dose to up to 160 Gy in certain patients with tomotherapy. The dose to the spinal cord and esophagus was also reduced in all cases with tomotherapy planning, compared with plans generated using conventional field arrangements. Both tomotherapy, and to a lesser extent conventional three-dimensional conformal radiotherapy, have the potential to significantly decrease radiation dose to lung and other normal structures in the treatment of NSCLC. This has important implications for dose escalation strategies in the future.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Radioterapia Assistida por Computador , Humanos , Dosagem Radioterapêutica , Radioterapia Conformacional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA