Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Surg Res ; 240: 156-164, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30933829

RESUMO

BACKGROUND: Aortic aneurysms in the viscerorenal-segment are nowadays treatable by endovascular means. Previously, new endograft techniques were only tested in healthy animals. We aimed to establish a new large animal model for testing complex endovascular stent techniques preclinically. METHODS: In sheep, four juxtarenal and two type IV thoracoabdominal aortic aneurysms were surgically created via a retroperitoneal approach. Two pieces out of a 10 × 15-cm bovine pericardial patch were sewn with the healthy aorta longitudinally. The viscerorenal segment was clamped, and the aorta was incised longitudinally. Then, the patches were longitudinally sewn together. In the meantime, antegrade flow through the native part of the aorta was already established by tangential clamping. Computed tomography angiography was performed after 4, 8, and 52 wk. RESULTS: Technical success was 100%. The median surgical procedure time was 3 h, the median blood loss was 210 mL, and the viscerorenal-segment clamping time was 2-4 min. The animals started drinking 1 h after arousal from anesthesia. One animal died after 1 wk because of delayed bleeding and another died after 1 y because of aneurysm rupture by a secondary bacterial infection. Four animals survived. The proximal landing zone diameter and the clock position of the vessel were stable over 52 wk. CONCLUSIONS: Surgical creation of an aortic aneurysm in the viscerorenal-segment in sheep was successful, without an ischemia/reperfusion injury. This animal model offers a new platform for evaluating innovative endovascular therapy options in vivo.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Modelos Animais de Doenças , Animais , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Ovinos , Resultado do Tratamento
2.
Front Cardiovasc Med ; 11: 1328906, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38596690

RESUMO

Background: Understanding complex cardiac anatomy is essential for percutaneous left atrial appendage (LAA) closure. Conventional multi-slice computed tomography (MSCT) and transesophageal echocardiography (TEE) are now supported by advanced 3D printing and virtual reality (VR) techniques for three-dimensional visualization of volumetric data sets. This study aimed to investigate their added value for LAA closure procedures. Methods: Ten patients scheduled for interventional LAA closure were evaluated with MSCT and TEE. Patient-specific 3D printings and VR models were fabricated based on MSCT data. Ten cardiologists then comparatively assessed LAA anatomy and its procedure relevant surrounding structures with all four imaging modalities and rated their procedural utility on a 5-point Likert scale questionnaire (from 1 = strongly agree to 5 = strongly disagree). Results: Device sizing was rated highest in MSCT (MSCT: 1.9 ± 0.8; TEE: 2.6 ± 0.9; 3D printing: 2.5 ± 1.0; VR: 2.5 ± 1.1; p < 0.01); TEE, VR, and 3D printing were superior in the visualization of the Fossa ovalis compared to MSCT (MSCT: 3.3 ± 1.4; TEE: 2.2 ± 1.3; 3D printing: 2.2 ± 1.4; VR: 1.9 ± 1.3; all p < 0.01). The major strength of VR and 3D printing techniques was a superior depth perception (VR: 1.6 ± 0.5; 3D printing: 1.8 ± 0.4; TEE: 2.9 ± 0.7; MSCT: 2.6 ± 0.8; p < 0.01). The visualization of extracardiac structures was rated less accurate in TEE than MSCT (TEE: 2.6 ± 0.9; MSCT: 1.9 ± 0.8, p < 0.01). However, 3D printing and VR insufficiently visualized extracardiac structures in the present study. Conclusion: A true 3D visualization in VR or 3D printing provides an additional value in the evaluation of the LAA for the planning of percutaneous closure. In particular, the superior perception of depth was seen as a strength of a 3D visualization. This may contribute to a better overall understanding of the anatomy. Clinical studies are needed to evaluate whether a more comprehensive understanding through advanced multimodal imaging of patient-specific anatomy using VR may translate into improved procedural outcomes.

3.
Acta Cardiol ; 67(6): 733-6, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23393947

RESUMO

Using cardiac computed tomography we examined a 72-year-old woman before surgery because of constrictive pericarditis after radiation therapy. Incidentally we discovered an anatomic variation of the right coronary artery with both atrial and ventricular muscle bridges. According to the patient's anamnesis and the characteristics of the courses the findings can be classified as not being harmful to the patient.


Assuntos
Angiografia Coronária/métodos , Vasos Coronários , Ventrículos do Coração/diagnóstico por imagem , Pericardite Constritiva/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Procedimentos Cirúrgicos Cardíacos , Diagnóstico Diferencial , Feminino , Humanos , Pericardite Constritiva/cirurgia
4.
PLoS One ; 16(4): e0249697, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33886607

RESUMO

INTRODUCTION: Aim of this study is to evaluate whether magnetic particle imaging (MPI) is capable of measuring velocities occurring in the coronary arteries and to compute coronary flow reserve (CFR) in a canonical phantom as a preliminary study. METHODS: For basic velocity measurements, a circulation phantom was designed containing replaceable glass tubes with three varying inner diameters, matching coronary-vessel diameters. Standardised boluses of superparamagnetic-iron-oxide-nanoparticles were injected and visualised by MPI. Two image-based techniques were competitively applied to calibrate the respective glass tube and to compute the mean velocity: full-duration-at-half-maximum (FDHM) and tracer dilution (TD) method. For CFR-calculation, four necessary settings of the circulation model of a virtual vessel with an inner diameter of 4 mm were generated using differently sized glass tubes and a stenosis model. The respective velocities in stenotic glass tubes were computed without recalibration. RESULTS: On velocity level, comparison showed a good agreement (rFDHM = 0.869, rTD = 0.796) between techniques, preferably better for 4 mm and 6 mm inner diameter glass tubes. On CFR level MPI-derived CFR-prediction performed considerably inferior with a relative error of 20-44%. CONCLUSIONS: MPI has the ability to reliably measure coronary blood velocities at rest as well as under hyperaemia and therefore may be suitable for CFR calculation. Calibration-associated accuracy of CFR-measurements has to be improved substantially in further studies.


Assuntos
Estenose Coronária/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Técnicas In Vitro/métodos , Velocidade do Fluxo Sanguíneo , Circulação Coronária , Estenose Coronária/sangue , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Hemodinâmica , Humanos , Fenômenos Magnéticos , Modelos Cardiovasculares , Imagens de Fantasmas
5.
J Clin Med ; 10(21)2021 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-34768667

RESUMO

BACKGROUND: The goal of cardiac evaluation of patients awaiting orthotopic liver transplantation (OLT) is to identify the patients at risk for cardiovascular events (CVEs) in the peri- and postoperative periods by opportunistic evaluation of coronary artery calcium (CAC) in non-gated abdominal computed tomographs (CT). METHODS: We hypothesized that in patients with OLT, a combination of Lee's revised cardiac index (RCRI) and CAC scoring would improve diagnostic accuracy and prognostic impact compared to non-invasive cardiac testing. Therefore, we retrospectively evaluated 169 patients and compared prediction of CVEs by both methods. RESULTS: Standard workup identified 22 patients with a high risk for CVEs during the transplant period, leading to coronary interventions. Eighteen patients had a CVE after transplant and a CAC score > 0. The combination of CAC and RCRI ≥ 2 had better negative (NPV) and positive predictive values (PPV) for CVEs (NPV 95.7%, PPV 81.6%) than standard non-invasive stress tests (NPV 92.0%, PPV 54.5%). CONCLUSION: The cutoff value of CAC > 0 by non-gated CTs combined with RCRI ≥ 2 is highly sensitive for identifying patients at risk for CVEs in the OLT population.

6.
Acad Radiol ; 27(9): 1249-1254, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31843393

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the image quality and suitability of Dual-Source Dual-Energy CT venography (DSDE-CTV) with asynchronous virtual monoenergetic images (VMI+) of the entire lower extremity in the context of pre-surgical assessment of complex cases prior to coronary bypass graft as a feasibility study. MATERIALS AND METHODS: Fifteen consecutive patients, consisting of 5 females and 10 males with an average age of 52 ± 17 years underwent DSDE-CTV from the pubic symphysis to the ankles after intravenous injection of an iodinated contrast medium. DSDE-CTV was acquired with tube voltages of 80 kVp and sn140 kVp. Single spectrum images (A - 80 kVp; B - 140 kVp) as well as a linearly blended mixed data set (M_0.6) were reconstructed. By postprocessing, an VMI+ dataset at 40 keV was generated. Objective image quality parameters of the deep and superficial veins of thigh, knee, and calves were measured separately for each location. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Additionally, subjective image quality was assessed independently by two radiologists. RESULTS: Mean vascular attenuation was 73.9 ± 17.8 HU at B, 113.7 ± 42.2 HU at M_0.6, 119.4 ± 45.5 HU at A, and 201.0 ± 89.7 HU at VMI+. Mean CNR was 6.7 ± 2.0 at 140 keV, 9.25 ± 2.3 in the M_0.6 datasets, 8.7 ± 3.0 at 80 keV, and 12.9 ± 4.3 at 40 keV. Attenuation values were approximately doubled when compared to the reference standard (M_0.6) with significantly improved SNR and CNR (p < 0.05). Subjective image quality scores were highest for VMI+ datasets (4.1 ± 0.5) and lowest for B datasets (2.3 ± 0.37), however differences between VMI+ datasets and M_0.6 datasets did not reach statistical significance. CONCLUSION: Postprocessing of dual-energy CTV with VMI+ significantly increases attenuation of veins and markedly improves SNR and CNR values, thereby improving the diagnostic quality of CTV for the evaluation of deep and superficial veins of the entire lower limb prior to coronary bypass graft.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Adulto , Idoso , Animais , Bovinos , Ponte de Artéria Coronária , Estudos de Viabilidade , Feminino , Humanos , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Flebografia , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído
7.
Clin Kidney J ; 13(4): 571-579, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32905245

RESUMO

BACKGROUND: Epicardial adipose tissue (EAT) exerts cardiopathogenic effects, but the independent association between EAT and cardiovascular (CV) calcification in patients with chronic kidney disease (CKD) remains controversial. We therefore assessed the association between EAT, CV risk factors and CV calcifications. METHODS: 257 patients with CKD Stage 3 and/or overt proteinuria underwent quantification of EAT, coronary artery calcification and aortic valve calcification by computed tomography. Framingham and American College of Cardiology and American Heart Association (ACC-AHA) 10-year CV event risk scores were calculated for each patient. RESULTS: Using multivariable regression analysis, higher EAT was significantly associated with the majority of investigated risk factors {higher age: odds ratio [OR] 1.05/year [95% confidence interval (CI) 1.02-1.08]; male sex: OR 4.03 [95% CI 2.22-7.31]; higher BMI: OR 1.28/kg/m2 [95% CI 1.20-1.37]; former smoking: OR 1.84 [95% CI 1.07-3.17]; lower high-density lipoprotein cholesterol: OR 0.98/mg/dL [95% CI 0.96-1.00] and lower estimated glomerular filtration rate: OR 0.98/mL/min/1.73 m2 [95% CI 0.97-0.99]; all P < 0.05} and was not associated with diabetes mellitus, hypertensive nephropathy, total cholesterol and albuminuria. EAT was positively associated with higher ACC-AHA and Framingham risk scores. EAT correlated with coronary artery calcification and aortic valve calcification [Spearman ρ = 0.388 (95% CI 0.287-0.532) and r rb = 0.409 (95% CI 0.310-0.556), respectively], but these correlations were dependent on CV risk factors. CONCLUSIONS: The increase of EAT can be explained by individual CV risk factors and kidney function and correlates with 10-year risk for CV event scores, suggesting that EAT is a modifiable risk factor in patients with CKD. Although EAT correlates with CV calcifications, these relations depend on CV risk factors.

8.
Acad Radiol ; 24(2): 167-174, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28010914

RESUMO

RATIONALE AND OBJECTIVES: Particularly for patients with heart arrhythmias, conventional BestSystole (BS) and BestDiastole (BD) reconstruction techniques in computed tomography (CT) frequently show artifacts that hinder the readability of the coronary tree. To address this problem, this paper presents an alternative reconstruction method that combines the technique "reconstructions with identical filling" (RIF) with motion mapping: This new technique is called "RIF in motion mapping" (RIMM). This study compares the diagnostic quality of images generated with RIMM to that of the other reconstruction techniques. MATERIALS AND METHODS: Having shown major artifacts in standard reconstructions, the CT datasets of 23 patients with suspected coronary artery disease or prior to transcatheter aortic valve replacement were selected manually. Each dataset was evaluated with four reconstruction techniques: BS, BD, RIF, and RIMM. Two radiologists, blinded to the applied reconstruction type, then evaluated the entire coronary tree of each sample using the 15-segment American Heart Association model and the six-grade Likert scale. RESULTS: Of the 345 analyzed coronary segments, the RIMM technique showed a significant number of images with reliable diagnostic quality (n = 228, 66%) as compared to RIF (P = 0.002) and BS/BD reconstructions (P < 0.001). Per coronary segment, vessel, and patient, the RIMM technique scored significantly better than the conventional BS/BD reconstructions (P = 0.003) and better than the RIF reconstructions with regard to the right coronary artery (P = 0.041). CONCLUSIONS: This new technique works: Using RIMM on the worst CT images substantially erased many of these artifacts, thereby enabling the radiologists to clearly visualize these segments. As RIMM considerably eliminates artifacts, this new CT reconstruction technique can help make a fast reliable evaluation of a patient's coronary tree. Thus, this enhanced visualization of cardiac images by RIMM avoids the need for further invasive diagnostic procedures.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Artefatos , Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Angiografia por Tomografia Computadorizada/normas , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Masculino , Movimento/fisiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA