RESUMO
BACKGROUND. Molecular breast imaging (MBI) is used for various breast imaging indications. An MBI lexicon has been developed, although the likelihood of malignancy of the lexicon descriptors has not been assessed to our knowledge. OBJECTIVE. The purpose of this article was to evaluate the PPV for malignancy of the MBI lexicon imaging descriptors. METHODS. This retrospective study included MBI examinations performed from August 1, 2005, through August 31, 2017, that were positive (BI-RADS analogous categories 0, 3, 4, 5, or 6) according to the clinical report and had an available reference standard. Examinations were performed using dual-detector cadmium zinc telluride MBI systems after injection of 99mTc sestamibi. Category 3 lesions had pathologic correlation, at least 2 years of imaging follow-up, or final resolution on follow-up imaging as category 1 or 2; category 4 and 5 lesions had pathologic correlation. MBI examinations were reviewed by one of two radiologists to assess lesions on the basis of the published MBI lexicon for type (mass vs nonmass uptake), distribution (if nonmass uptake), uptake intensity, and number of MBI views on which the lesion was seen. PPV for malignancy was summarized. RESULTS. The analysis included 643 lesions (479 benign, 164 malignant; 83 mass, 560 nonmass uptake) in 509 patients (median age, 56 years). PPV was 73.5% (61/83) for masses and 18.4% (103/560) for nonmass uptake. Among the nonmass uptake lesions, PPV was 36.2% (17/47) for segmental, 20.1% (77/384) for focal, 30.8% (4/13) for diffuse, and 4.3% (5/116) for regional or multiple regional distribution. PPV was 5.3% (5/94) for one view, 15.2% (32/210) for two views, 14.6% (13/89) for three views, and 45.4% (113/249) for four views showing the lesion. PPV was 14.0% (43/307) for mild, 22.4% (51/228) for moderate, and 64.8% (70/108) for marked uptake intensity. CONCLUSION. The MBI lexicon lesion descriptors are associated with likelihood of malignancy. PPV was higher for masses, lesions seen on multiple MBI views, and lesions with marked uptake intensity. Among nonmass uptake lesions, PPV was highest for those with segmental distribution. CLINICAL IMPACT. Insight into the likelihood of malignancy associated with the MBI lexicon descriptors can inform radiologists' interpretations and guide potential future incorporation of the MBI lexicon into the ACR BI-RADS Atlas.
Assuntos
Neoplasias da Mama , Mamografia , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Mamografia/métodos , Probabilidade , Cintilografia , Exame Físico , Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodosRESUMO
Integrated care pathways (ICPs) are evidence-based decision support tools intended to reduce variation and improve quality of care. Historically, adoption of ICPs has been difficult to measure, as the pathways were outside of the electronic health record (EHR), where care delivery documentation and orders were completed. This Technology Column describes the innovative development and implementation of a diagnosis specific electronic ICP that directly embeds pathway steps into an EHR to facilitate order sets, clinical decision-making, and usage tracking. The pathway was implemented at a seven-hospital academic medical center, and details the technology, team structure, early adoption results, and future directions. As such, the importance of investing and organizing resources to create an eICP (e.g., time, technology, and specialized teams) to provide a user-friendly experience to support early adoption is underscored. Preliminary findings show that the eICP had consistent use in the first year of implementation. This manuscript is intended to serve as a practical guide to build eICPs within behavioral health service areas across institutions.
Assuntos
Prestação Integrada de Cuidados de Saúde , Psiquiatria , Humanos , Registros Eletrônicos de Saúde , Qualidade da Assistência à Saúde , Centros Médicos AcadêmicosRESUMO
BACKGROUND: The objective of this randomized trial was to evaluate the short-term effect of bilingual written and interpersonal education regarding mammographic breast density (MBD). METHODS: Latinas aged 40 to 74 years who were presenting for screening mammography were recruited and randomized 1:1:1 to receive a letter with their mammogram and MBD results (usual care [UC]), a letter plus a brochure (enhanced care [ENH]), or a letter plus a brochure and telephonic promotora education (interpersonal care [INT]). Surveys were administered at enrollment (T0 ) and 2 weeks to 6 months after intervention delivery (T1 ). Differences were assessed with χ2 , Kruskal-Wallis, and McNemar tests and pairwise comparisons as appropriate. INT metrics and audio recordings were analyzed with descriptive statistics and qualitative content analysis. RESULTS: Between October 2016 and October 2019, 943 of 1108 Latina participants (85%) completed both surveys. At T1 , INT participants were more likely (P < .001) to report seeing their MBD results in the letter (70.2%) than UC (53.1%) or ENH participants (55.1%). The percentage of INT women who reported speaking with a provider about MBD (29.0%) was significantly greater (P < .001) than the percentage of UC (14.7%) or ENH participants (15.6%). All groups saw significant (P < .001) but nondifferential improvements in their knowledge of MBD as a masking and risk factor. In the INT group, the promotora delivered education to 77.1% of the 446 participants randomized to INT and answered questions at 28.3% of the encounters for an average of $4.70 per participant. CONCLUSIONS: Among Latinas in a low-resource setting, MBD knowledge may increase with written or interpersonal education, but with modest investment, interpersonal education may better improve MBD awareness and prompt patient-provider discussions.
Assuntos
Densidade da Mama , Neoplasias da Mama , Adulto , Idoso , Detecção Precoce de Câncer , Feminino , Hispânico ou Latino , Humanos , Mamografia , Pessoa de Meia-IdadeRESUMO
BACKGROUND. Background parenchymal uptake (BPU) on molecular breast imaging (MBI) was identified in a case-control study as a breast cancer risk factor beyond mammographic density. To our knowledge, this finding has not yet been confirmed in a cohort study. OBJECTIVE. The objectives of this study were to examine the association of BPU with breast cancer and to estimate the absolute risk and discriminatory accuracy of BPU in a cohort study. METHODS. A retrospective cohort was established that included women without a history of breast cancer who underwent MBI from 2004 to 2015. Radiologists who were blinded to future breast cancer diagnoses assessed BPU on baseline MBI examinations as low (photopenic or minimal) or elevated (mild, moderate, or marked). Associations of BPU with breast cancer were estimated using multivariable Cox proportional hazards models of the time to diagnosis. The 5-year absolute risk was calculated for study subgroups. The discriminatory accuracy of BPU was also assessed. RESULTS. Among 2992 women (mean age, 56.3 years; SD, 10.6 years) who underwent MBI, breast cancer events occurred in 144 women (median follow-up, 7.3 years). Median time to diagnosis after MBI was 4.2 years (range, 0.5-11.6 years). Elevated BPU was associated with a greater breast cancer risk (hazard ratio [HR], 2.39; 95% CI, 1.68-3.41; p ≤ .001). This association remained in postmenopausal women (HR, 3.50; 95% CI, 2.31-5.31; p < .001) but was not significant in premenopausal women (HR, 1.29; 95% CI, 0.72-2.32; p = .39). The 5-year absolute risk of breast cancer was 4.3% (95% CI, 2.9-5.7%) for women with elevated BPU versus 2.5% (95% CI, 1.8-3.1%) for those with low BPU. Postmenopausal women with dense breasts and elevated BPU had a 5-year absolute risk of 8.1% (95% CI, 4.3-11.8%) versus 2.8% (1.8-3.8%) for those with low BPU. Among postmenopausal women, discriminatory accuracy for invasive cancer was improved with the addition of BPU versus use of the Gail risk score alone (C statistic, 65.1 vs 59.1; p = .04) or use of the Breast Cancer Surveillance Consortium risk score alone (C statistic, 66.4 vs 60.4; p = .04). CONCLUSION. BPU on MBI is an independent risk factor for breast cancer, with the strongest association observed among postmenopausal women with dense breasts. In postmenopausal women, BPU provides incremental discrimination in predicting breast cancer when combined with either the Gail model or the Breast Cancer Surveillance Consortium model. CLINICAL IMPACT. Observation of elevated BPU on MBI may identify a subset of women with dense breasts who would benefit most from supplemental screening or preventive options.
Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Imagem Molecular/métodos , Tecido Parenquimatoso/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos RetrospectivosRESUMO
OBJECTIVE. The purpose of this study was to determine whether application of a proprietary image-processing algorithm would allow a reduction in the necessary administered activity for molecular breast imaging (MBI) examinations. MATERIALS AND METHODS. Images from standard-dose MBI examinations (300 MBq 99mTc-sestamibi) of 50 subjects were analyzed. The images were acquired in dynamic mode and showed at least one breast lesion. Half-dose MBI examinations were simulated by summing one-half of the dynamic frames and were processed with the algorithm under study in both a default and a preferred filter mode. Two breast radiologists independently completed a set of two-alternative forced-choice tasks to compare lesion conspicuity on standard-dose images, half-dose images, and the algorithm-processed half-dose images in both modes. RESULTS. Relative to the standard-dose images, the half-dose images were preferred in 4, the default-filtered half-dose images in 50, and preferred-filtered half-dose images in 76 of 100 readings. Compared with standard-dose images, in terms of lesion conspicuity, the half-dose images were rated better in 2, equivalent in 6, and poorer in 92 of 100 readings. The default-filtered half-dose images were rated better, equivalent, or poorer in 13, 73, and 14 of 100 readings. The preferred-filtered half-dose images were rated as better, equivalent, or poorer in 55, 34, and 11 of 100 readings. CONCLUSION. Compared with that on standard-dose images, lesion conspicuity on images obtained with the algorithm and acquired at one-half the standard dose was equivalent or better without compromise of image quality. The algorithm can also be used to decrease imaging time with a resulting increase in patient comfort and throughput.
Assuntos
Algoritmos , Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imagem Molecular/métodos , Doses de Radiação , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , CintilografiaRESUMO
BACKGROUND: High background parenchymal uptake (BPU) on molecular breast imaging (MBI) has been identified as a breast cancer risk factor. We explored the feasibility of offering a short-term intervention of low-dose oral tamoxifen to women with high BPU and examined whether this intervention would reduce BPU. METHODS: Women with a history of high BPU and no breast cancer history were invited to the study. Participants had an MBI exam, followed by 30 days of low-dose oral tamoxifen at either 5 mg or 10 mg/day, and a post-tamoxifen MBI exam. BPU on pre- and post-tamoxifen MBI exams was quantitatively assessed as the ratio of average counts in breast fibroglandular tissue vs. average counts in subcutaneous fat. Pre-tamoxifen and post-tamoxifen BPU were compared with paired t tests. RESULTS: Of 47 women invited, 22 enrolled and 21 completed the study (10 taking 5 mg tamoxifen, 11 taking 10 mg tamoxifen). Mean age was 47.7 years (range 41-56 years). After 30 days low-dose tamoxifen, 8 of 21 women (38%) showed a decline in BPU, defined as a decrease from the pre-tamoxifen MBI of at least 15%; 11 of 21 (52%) had no change in BPU (within ± 15%); 2 of 21 (10%) had an increase in BPU of greater than 15%. Overall, the average post-tamoxifen BPU was not significantly different from pre-tamoxifen BPU (1.34 post vs. 1.43 pre, p = 0.11). However, among women taking 10 mg tamoxifen, 5 of 11 (45%) showed a decline in BPU; average BPU was 1.19 post-tamoxifen vs. 1.34 pre-tamoxifen (p = 0.005). In women taking 5 mg tamoxifen, 2 of 10 (20%) showed a decline in BPU; average BPU was 1.51 post-tamoxifen vs.1.53 pre-tamoxifen (p = 0.99). CONCLUSIONS: Short-term intervention with low-dose tamoxifen may reduce high BPU on MBI for some patients. Our preliminary findings suggest that 10 mg tamoxifen per day may be more effective than 5 mg for inducing declines in BPU within 30 days. Given the variability in BPU response to tamoxifen observed among study participants, future study is warranted to determine if BPU response could predict the effectiveness of tamoxifen for breast cancer risk reduction within an individual. TRIAL REGISTRATION: ClinicalTrials.gov NCT02979301 . Registered 01 December 2016.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Mamografia/métodos , Imagem Molecular/métodos , Tamoxifeno/administração & dosagem , Administração Oral , Adulto , Mama/patologia , Densidade da Mama/efeitos dos fármacos , Neoplasias da Mama/patologia , Estudos de Viabilidade , Feminino , Câmaras gama , Humanos , Mamografia/instrumentação , Pessoa de Meia-Idade , Imagem Molecular/instrumentação , Projetos Piloto , Estudos Prospectivos , Cintilografia/instrumentação , Cintilografia/métodos , Compostos Radiofarmacêuticos/administração & dosagem , Tecnécio Tc 99m Sestamibi/administração & dosagem , Fatores de TempoRESUMO
BACKGROUND: Background parenchymal uptake (BPU), which refers to the level of Tc-99m sestamibi uptake within normal fibroglandular tissue on molecular breast imaging (MBI), has been identified as a breast cancer risk factor, independent of mammographic density. Prior analyses have used subjective categories to describe BPU. We evaluate a new quantitative method for assessing BPU by testing its reproducibility, comparing quantitative results with previously established subjective BPU categories, and determining the association of quantitative BPU with breast cancer risk. METHODS: Two nonradiologist operators independently performed region-of-interest analysis on MBI images viewed in conjunction with corresponding digital mammograms. Quantitative BPU was defined as a unitless ratio of the average pixel intensity (counts/pixel) within the fibroglandular tissue versus the average pixel intensity in fat. Operator agreement and the correlation of quantitative BPU measures with subjective BPU categories assessed by expert radiologists were determined. Percent density on mammograms was estimated using Cumulus. The association of quantitative BPU with breast cancer (per one unit BPU) was examined within an established case-control study of 62 incident breast cancer cases and 177 matched controls. RESULTS: Quantitative BPU ranged from 0.4 to 3.2 across all subjects and was on average higher in cases compared to controls (1.4 versus 1.2, p < 0.007 for both operators). Quantitative BPU was strongly correlated with subjective BPU categories (Spearman's r = 0.59 to 0.69, p < 0.0001, for each paired combination of two operators and two radiologists). Interoperator and intraoperator agreement in the quantitative BPU measure, assessed by intraclass correlation, was 0.92 and 0.98, respectively. Quantitative BPU measures showed either no correlation or weak negative correlation with mammographic percent density. In a model adjusted for body mass index and percent density, higher quantitative BPU was associated with increased risk of breast cancer for both operators (OR = 4.0, 95% confidence interval (CI) 1.6-10.1, and 2.4, 95% CI 1.2-4.7). CONCLUSION: Quantitative measurement of BPU, defined as the ratio of average counts in fibroglandular tissue relative to that in fat, can be reliably performed by nonradiologist operators with a simple region-of-interest analysis tool. Similar to results obtained with subjective BPU categories, quantitative BPU is a functional imaging biomarker of breast cancer risk, independent of mammographic density and hormonal factors.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Imagem Molecular , Tecido Parenquimatoso/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/patologia , Densidade da Mama , Neoplasias da Mama/patologia , Estudos de Casos e Controles , Feminino , Humanos , Mamografia/métodos , Pessoa de Meia-Idade , Fatores de RiscoRESUMO
The NCCN Guidelines for Small Cell Lung Cancer (SCLC) address all aspects of disease management. These NCCN Guidelines Insights focus on recent updates to the NCCN Guidelines for SCLC regarding immunotherapy, systemic therapy, and radiation therapy. For the 2018 update, new sections were added on "Signs and Symptoms of SCLC" and "Principles of Pathologic Review."
Assuntos
Neoplasias Encefálicas/prevenção & controle , Neoplasias Pulmonares/terapia , Oncologia/normas , Carcinoma de Pequenas Células do Pulmão/terapia , Antineoplásicos Imunológicos/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias Encefálicas/secundário , Quimiorradioterapia/métodos , Quimiorradioterapia/normas , Irradiação Craniana/métodos , Irradiação Craniana/normas , Relação Dose-Resposta à Radiação , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Oncologia/métodos , Estadiamento de Neoplasias , Pneumonectomia/métodos , Pneumonectomia/normas , Dosagem Radioterapêutica , Ensaios Clínicos Controlados Aleatórios como Assunto , Carcinoma de Pequenas Células do Pulmão/diagnóstico , Carcinoma de Pequenas Células do Pulmão/mortalidade , Carcinoma de Pequenas Células do Pulmão/secundário , Sociedades Médicas/normas , Análise de Sobrevida , Resultado do Tratamento , Estados UnidosRESUMO
INTRODUCTION AND HYPOTHESIS: The aim of this study was to compare outcomes after uterosacral ligament suspension (USLS) or sacrocolpopexy for symptomatic stage IV apical pelvic organ prolapse (POP) and evaluate predictors of prolapse recurrence. METHODS: The medical records of patients managed surgically for stage IV apical POP from January 2002 to June 2012 were reviewed. A follow-up survey was sent to these patients. The primary outcome, prolapse recurrence, was defined as recurrence of prolapse symptoms measured by validated questionnaire or surgical retreatment. Survival time free of prolapse recurrence was estimated using the Kaplan-Meier method, and Cox proportional hazards models evaluated factors for an association with recurrence. RESULTS: Of 2633 women treated for POP, 399 (15.2%) had stage IV apical prolapse and were managed with either USLS (n = 355) or sacrocolpopexy (n = 44). Those managed with USLS were significantly older (p < 0.001) and less likely to have a prior hysterectomy (39.7 vs 86.4%; p < 0.001) or prior apical prolapse repair (8.2 38.6%; p < 0.001). Median follow-up was 4.3 years [interquartile range (IQR) 1.1-7.7]. Survival free of recurrence was similar between USLS and sacrocolpopexy (p = 0.43), with 5-year rates of 88.7 and 97.6%, respectively. Younger age [adjusted hazard ratio (aHR) 1.55, 95% confidence interval (CI) 1.12-2.13; p = 0.008] and prior hysterectomy (aHR 2.8, 95% CI 1.39-5.64; p = 0.004) were associated with the risk of prolapse recurrence, whereas type of surgery approached statistical significance (aHR 2.76, 95% CI 0.80-9.60; p = 0.11). CONCLUSIONS: Younger age and history of prior hysterectomy were associated with an increased risk of recurrent prolapse symptoms. Notably, excellent survival free of prolapse recurrence were obtained with both surgical techniques.
Assuntos
Procedimentos Cirúrgicos em Ginecologia/efeitos adversos , Prolapso de Órgão Pélvico/cirurgia , Complicações Pós-Operatórias/etiologia , Vagina/cirurgia , Adulto , Fatores Etários , Feminino , Procedimentos Cirúrgicos em Ginecologia/métodos , Humanos , Histerectomia , Estimativa de Kaplan-Meier , Modelos de Riscos Proporcionais , Índice de Gravidade de Doença , Falha de Tratamento , Resultado do Tratamento , Adulto JovemRESUMO
BACKGROUND: Molecular breast imaging (MBI) is a functional test used for supplemental screening of women with mammographically dense breasts. Additionally, MBI depicts variable levels of background parenchymal uptake (BPU) within nonmalignant, dense fibroglandular tissue. We investigated whether BPU is a risk factor for breast cancer. METHODS: We conducted a retrospective case-control study of 3027 eligible women who had undergone MBI between February 2004 and February 2014. Sixty-two incident breast cancer cases were identified. A total of 179 controls were matched on age, menopausal status, and MBI year. Two radiologists blinded to case status independently assessed BPU as one of four categories: photopenic, minimal to mild, moderate, or marked. Conditional logistic regression analysis was performed to estimate the associations (OR) of BPU categories (moderate or marked vs. minimal to mild or photopenic) and breast cancer risk, adjusted for other risk factors. RESULTS: The median age was 60.2 years (range 38-86 years) for cases vs. 60.2 years (range 38-88 years) for controls (p = 0.88). Women with moderate or marked BPU had a 3.4-fold (95 % CI 1.6-7.3) and 4.8-fold (95 % CI 2.1-10.8) increased risk of breast cancer, respectively, compared with women with photopenic or minimal to mild BPU, for two radiologists. The results were similar after adjustment for BI-RADS density (OR 3.3 [95 % CI 1.6-7.2] and OR 4.6 [95 % CI 2.1-10.5]) or postmenopausal hormone use (OR 3.6 [95 % CI 1.7-7.7] and OR 5.0 [95 % CI 2.2-11.4]). The association of BPU with breast cancer remained in analyses limited to postmenopausal women only (OR 3.8 [95 % CI 1.5-9.3] and OR 4.1 [95 % CI 1.6-10.2]) and invasive breast cancer cases only (OR 3.6 [95 % CI 1.5-8.8] and OR 4.4 [95 % CI 1.7-11.1]). Variable BPU was observed among women with similar mammographic density; the distribution of BPU categories differed across density categories (p < 0.0001). CONCLUSIONS: This study provides the first evidence for BPU as a risk factor for breast cancer. Among women with dense breasts, who comprise >40 % of the screening population, BPU may serve as a functional imaging biomarker to identify the subset at greatest risk.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imagem Molecular , Adulto , Idoso , Idoso de 80 Anos ou mais , Densidade da Mama , Estudos de Casos e Controles , Feminino , Humanos , Glândulas Mamárias Humanas/diagnóstico por imagem , Glândulas Mamárias Humanas/patologia , Pessoa de Meia-Idade , Imagem Molecular/métodos , Invasividade Neoplásica , Estadiamento de Neoplasias , Cintilografia/métodos , Estudos Retrospectivos , Fatores de RiscoRESUMO
More than 50 % of states have state-mandated density notification for patients with heterogeneously or extremely dense breasts. Increased breast density carries a risk of masking a cancer and delaying diagnosis. Supplemental imaging is optional and often recommended for certain patients. There are no evidence-based consensus guidelines for screening patients with density as their only risk factor. Breast cancer risk assessment and breast cancer prevention strategies should be discussed with women with dense breasts.
Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/prevenção & controle , Comunicação , Legislação Médica , Detecção Precoce de Câncer , Feminino , Humanos , Imageamento por Ressonância Magnética , Mamografia/métodos , Imagem Molecular , Educação de Pacientes como Assunto , Medição de Risco , Fatores de Risco , Ultrassonografia MamáriaRESUMO
OBJECTIVE: The purposes of this study were to compare the tumor appearance of invasive breast cancer on direct-conversion molecular breast imaging using a standardized lexicon and to determine how often direct-conversion molecular breast imaging identifies all known invasive tumor foci in the breast, and whether this differs for invasive ductal versus lobular histologic profiles. MATERIALS AND METHODS: Patients with prior invasive breast cancer and concurrent direct-conversion molecular breast imaging examinations were retrospectively reviewed. Blinded review of direct-conversion molecular breast imaging examinations was performed by one of two radiologists, according to a validated lexicon. Direct-conversion molecular breast imaging findings were matched with lesions described on the pathology report to exclude benign reasons for direct-conversion molecular breast imaging findings and to document direct-conversion molecular breast imaging-occult tumor foci. Associations between direct-conversion molecular breast imaging findings and tumor histologic profiles were examined using chi-square tests. RESULTS: In 286 patients, 390 invasive tumor foci were present in 294 breasts. A corresponding direct-conversion molecular breast imaging finding was present for 341 of 390 (87%) tumor foci described on the pathology report. Invasive ductal carcinoma (IDC) tumor foci were more likely to be a mass (40% IDC vs 15% invasive lobular carcinoma [ILC]; p < 0.001) and to have marked intensity than were ILC foci (63% IDC vs 32% ILC; p < 0.001). Direct-conversion molecular breast imaging correctly revealed all pathology-proven foci of invasive disease in 79.8% of cases and was more likely to do so for IDC than for ILC (86.1% vs 56.7%; p < 0.0001). Overall, direct-conversion molecular breast imaging showed all known invasive foci in 249 of 286 (87%) patients. CONCLUSION: Direct-conversion molecular breast imaging features of invasive cancer, including lesion type and intensity, differ by histologic subtype. Direct-conversion molecular breast imaging is less likely to show all foci of ILC compared with IDC.
Assuntos
Neoplasias da Mama/diagnóstico , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Lobular/diagnóstico , Imagem Molecular , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Sensibilidade e Especificidade , Tecnécio Tc 99m SestamibiRESUMO
OBJECTIVE: The purpose of this study was to examine additional diagnostic workup and costs generated by addition of a single molecular breast imaging (MBI) examination to screening mammography for women with dense breasts. SUBJECTS AND METHODS: Women with mammographically dense breasts presenting for screening mammography underwent adjunct MBI performed with 300 MBq (99m)Tc-sestamibi and a direct-conversion cadmium-zinc-telluride dual-head gamma camera. All subsequent imaging tests and biopsies were tracked for a minimum of 1 year. The positive predictive value of biopsies performed (PPV3), benign biopsy rate, cost per patient screened, and cost per cancer detected were determined. RESULTS: A total of 1651 women enrolled in the study. Among the 1585 participants with complete reference standard, screening mammography alone prompted diagnostic workup of 175 (11.0%) patients and biopsy of 20 (1.3%) and yielded five malignancies (PPV3, 25%). Results of combined screening mammography plus MBI prompted diagnostic workup of 279 patients (17.6%) and biopsy of 67 (4.2%) and yielded 19 malignancies (PPV3, 28.4%). The benign biopsy rates were 0.9% (15 of 1585) for screening mammography alone and 3.0% (48 of 1585) for the combination (p < 0.001). The addition of MBI increased the cost per patient screened from $176 for mammography alone to $571 for the combination. However, cost per cancer detected was lower for the combination ($47,597) than for mammography alone ($55,851). CONCLUSION: The addition of MBI to screening mammography of women with dense breasts increased the overall costs and benign biopsy rate but also increased the cancer detection rate, which resulted in a lower cost per cancer detected than with screening mammography alone.
Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/economia , Detecção Precoce de Câncer/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Mamografia/economia , Imagem Molecular/economia , Tomografia por Emissão de Pósitrons/economia , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Prevalência , Compostos Radiofarmacêuticos/economia , Tecnécio Tc 99m Sestamibi/economia , Estados Unidos/epidemiologiaRESUMO
OBJECTIVE. The purposes of this study were to describe the prevalence of background parenchymal uptake categories observed at screening molecular breast imaging (MBI) and to examine the association of background parenchymal uptake with mammographic density and other clinical factors. MATERIALS AND METHODS. Adjunct MBI screening was performed for women with dense breasts on previous mammograms. Two radiologists reviewed images from the MBI examinations and subjectively categorized background parenchymal uptake into four groups: photopenic, minimal-mild, moderate, or marked. Women with breast implants or a personal history of breast cancer were excluded. The association between background parenchymal uptake categories and patient characteristics was examined with Kruskal-Wallis and chi-square tests as appropriate. RESULTS. In 1149 eligible participants, background parenchymal uptake was photopenic in 252 (22%), minimal-mild in 728 (63%), and moderate or marked in 169 (15%). The distribution of categories differed across BI-RADS density categories (p < 0.0001). In 164 participants with extremely dense breasts, background parenchymal uptake was photopenic in 72 (44%), minimal-mild in 55 (34%), and moderate or marked in 37 (22%). The moderate-marked group was younger on average, more likely to be premenopausal or perimenopausal, and more likely to be using postmenopausal hormone therapy than the photopenic or minimal-mild groups (p < 0.0001). CONCLUSION. Among women with similar-appearing mammographic density, background parenchymal uptake ranged from photopenic to marked. Background parenchymal uptake was associated with menopausal status and postmenopausal hormone therapy but not with premenopausal hormonal contraceptives, phase of menstrual cycle, or Gail model 5-year risk of breast cancer. Additional work is necessary to fully characterize the underlying cause of background parenchymal uptake and determine its utility in predicting subsequent risk of breast cancer.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Glândulas Mamárias Humanas/anormalidades , Imagem Molecular , Densidade da Mama , Feminino , Humanos , Pessoa de Meia-Idade , Cintilografia , Estudos RetrospectivosRESUMO
OBJECTIVE. The purpose of this study was to assess the diagnostic performance of supplemental screening molecular breast imaging (MBI) in women with mammographically dense breasts after system modifications to permit radiation dose reduction. SUBJECTS AND METHODS. A total of 1651 asymptomatic women with mammographically dense breasts on prior mammography underwent screening mammography and adjunct MBI performed with 300-MBq (99m)Tc-sestamibi and a direct-conversion (cadmium zinc telluride) gamma camera, both interpreted independently. The cancer detection rate, sensitivity, specificity, and positive predictive value of biopsies performed (PPV3) were determined. RESULTS. In 1585 participants with a complete reference standard, 21 were diagnosed with cancer: two detected by mammography only, 14 by MBI only, three by both modalities, and two by neither. Of 14 participants with cancers detected only by MBI, 11 had invasive disease (median size, 0.9 cm; range, 0.5-4.1 cm). Nine of 11 (82%) were node negative, and two had bilateral cancers. With the addition of MBI to mammography, the overall cancer detection rate (per 1000 screened) increased from 3.2 to 12.0 (p < 0.001) (supplemental yield 8.8). The invasive cancer detection rate increased from 1.9 to 8.8 (p < 0.001) (supplemental yield 6.9), a relative increase of 363%, while the change in DCIS detection was not statistically significant (from 1.3 to 3.2, p =0.250). For mammography alone, sensitivity was 24%; specificity, 89%; and PPV3, 25%. For the combination, sensitivity was 91% (p < 0.001); specificity, 83% (p < 0.001); and PPV3, 28% (p = 0.70). The recall rate increased from 11.0% with mammography alone to 17.6% (p < 0.001) for the combination; the biopsy rate increased from 1.3% for mammography alone to 4.2% (p < 0.001). CONCLUSION. When added to screening mammography, MBI performed using a radiopharmaceutical activity acceptable for screening (effective dose 2.4 mSv) yielded a supplemental cancer detection rate of 8.8 per 1000 women with mammographically dense breasts.
Assuntos
Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Imagem Molecular , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de RadiaçãoRESUMO
Minnesota recently became the 16th state to require facilities that perform mammograms to notify patients if they are found to have dense or extremely dense breasts, as this may make it more difficult to detect a cancer or put them at increased risk for cancer. This article outlines the new law and describes the classification system for breast density, the implications for breast density on screening mammography, and the relationship between breast density and cancer. It also provides guidance for patients who have dense breast tissue regarding supplementary screening.
Assuntos
Mama/patologia , Mamografia , Programas de Rastreamento/legislação & jurisprudência , Educação de Pacientes como Assunto/legislação & jurisprudência , Feminino , Humanos , Minnesota , Sensibilidade e EspecificidadeRESUMO
Importance: Early warning decision support tools to identify clinical deterioration in the hospital are widely used, but there is little information on their comparative performance. Objective: To compare 3 proprietary artificial intelligence (AI) early warning scores and 3 publicly available simple aggregated weighted scores. Design, Setting, and Participants: This retrospective cohort study was performed at 7 hospitals in the Yale New Haven Health System. All consecutive adult medical-surgical ward hospital encounters between March 9, 2019, and November 9, 2023, were included. Exposures: Simultaneous Epic Deterioration Index (EDI), Rothman Index (RI), eCARTv5 (eCART), Modified Early Warning Score (MEWS), National Early Warning Score (NEWS), and NEWS2 scores. Main Outcomes and Measures: Clinical deterioration, defined as a transfer from ward to intensive care unit or death within 24 hours of an observation. Results: Of the 362â¯926 patient encounters (median patient age, 64 [IQR, 47-77] years; 200â¯642 [55.3%] female), 16â¯693 (4.6%) experienced a clinical deterioration event. eCART had the highest area under the receiver operating characteristic curve at 0.895 (95% CI, 0.891-0.900), followed by NEWS2 at 0.831 (95% CI, 0.826-0.836), NEWS at 0.829 (95% CI, 0.824-0.835), RI at 0.828 (95% CI, 0.823-0.834), EDI at 0.808 (95% CI, 0.802-0.812), and MEWS at 0.757 (95% CI, 0.750-0.764). After matching scores at the moderate-risk sensitivity level for a NEWS score of 5, overall positive predictive values (PPVs) ranged from a low of 6.3% (95% CI, 6.1%-6.4%) for an EDI score of 41 to a high of 17.3% (95% CI, 16.9%-17.8%) for an eCART score of 94. Matching scores at the high-risk specificity of a NEWS score of 7 yielded overall PPVs ranging from a low of 14.5% (95% CI, 14.0%-15.2%) for an EDI score of 54 to a high of 23.3% (95% CI, 22.7%-24.2%) for an eCART score of 97. The moderate-risk thresholds provided a median of at least 20 hours of lead time for all the scores. Median lead time at the high-risk threshold was 11 (IQR, 0-69) hours for eCART, 8 (IQR, 0-63) hours for NEWS, 6 (IQR, 0-62) hours for NEWS2, 5 (IQR, 0-56) hours for MEWS, 1 (IQR, 0-39) hour for EDI, and 0 (IQR, 0-42) hours for RI. Conclusions and Relevance: In this cohort study of inpatient encounters, eCART outperformed the other AI and non-AI scores, identifying more deteriorating patients with fewer false alarms and sufficient time to intervene. NEWS, a non-AI, publicly available early warning score, significantly outperformed EDI. Given the wide variation in accuracy, additional transparency and oversight of early warning tools may be warranted.
Assuntos
Inteligência Artificial , Escore de Alerta Precoce , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Idoso , Deterioração Clínica , Unidades de Terapia Intensiva/estatística & dados numéricos , Curva ROC , Mortalidade HospitalarRESUMO
Molecular breast imaging (MBI) is one of several options available to patients seeking supplemental screening due to mammographically dense breasts. Patient experience during MBI may influence willingness to undergo the test but has yet to be formally assessed. We aimed to assess patient comfort level during MBI, to compare MBI comfort with mammography comfort, to identify factors associated with MBI discomfort, and to evaluate patients' willingness to return for future MBI. Methods: A 10-question survey was sent by e-mail to patients undergoing MBI between August and December 2022 to obtain quantitative assessments and qualitative opinions about MBI. Results: Of 561 invited patients, 209 (37%) completed the survey and provided study consent. Their average age was 60.1 y (range, 40-81 y). Of the 209 responders, 202 (97%) were presenting for screening MBI, 195 (94%) had dense breasts, and 46 (22%) had a personal history of breast cancer. The average rating of MBI comfort was 2.9 (SD, 1.5; median, 3.0) on a 7-point scale (1 indicating extremely comfortable and 7 indicating extremely uncomfortable). The rating distribution was as follows: 140 (67%) comfortable (rating, 1-3); 24 (12%) neither comfortable nor uncomfortable (rating, 4); and 45 (22%) uncomfortable (rating, 5 or 6). No responders gave a 7 rating. The most frequently mentioned sources of discomfort included breast compression (n = 16), back or neck discomfort (n = 14), and maintaining position during the examination (n = 14). MBI comfort was associated with responder age (74% ≥55 y old were comfortable, versus 53% <55 y old [P = 0.003]) and history of MBI (71% with prior MBI were comfortable, versus 61% having a first MBI [P = 0.006]). Of 208 responders with a prior mammogram, 148 (71%) said MBI is more comfortable than mammography (a significant majority [P < 0.001]). Of 202 responders to the question of whether they were willing to return for a future MBI, 196 (97%) were willing. A notable factor in positive patient experience was interaction with the MBI nuclear medicine technologist. Conclusion: Most responders thought MBI to be a comfortable examination and more comfortable than mammography. Patient experience during MBI may be improved by ensuring back support and soliciting patient feedback at the time of positioning and throughout the examination. Methods under study to reduce imaging time may be most important for improving patient experience.
Assuntos
Imagem Molecular , Humanos , Pessoa de Meia-Idade , Idoso , Adulto , Feminino , Inquéritos e Questionários , Idoso de 80 Anos ou mais , Imagem Molecular/métodos , Neoplasias da Mama/diagnóstico por imagem , MamografiaRESUMO
OBJECTIVE: Early detection of clinical deterioration using machine learning early warning scores may improve outcomes. However, most implemented scores were developed using logistic regression, only underwent retrospective validation, and were not tested in important subgroups. Our objective was to develop and prospectively validate a gradient boosted machine model (eCARTv5) for identifying clinical deterioration on the wards. DESIGN: Multicenter retrospective and prospective observational study. SETTING: Inpatient admissions to the medical-surgical wards at seven hospitals in three health systems for model development (2006-2022) and at 21 hospitals from three health systems for retrospective (2009-2023) and prospective (2023-2024) external validation. PATIENTS: All adult patients hospitalized at each participating health system during the study years. INTERVENTIONS: None MEASUREMENTS AND MAIN RESULTS: Predictor variables (demographics, vital signs, documentation, and laboratory values) were used in a gradient boosted trees algorithm to predict intensive care unit transfer or death in the next 24 hours. The developed model (eCART) was compared to the Modified Early Warning Score (MEWS) and the National Early Warning Score (NEWS) using the area under the receiver operating characteristic curve (AUROC). The development cohort included 901,491 admissions, the retrospective validation cohort included 1,769,461 admissions, and the prospective validation cohort included 205,946 admissions. In retrospective validation, eCART had the highest AUROC (0.835; 95%CI 0.834, 0.835), followed by NEWS (0.766 (95%CI 0.766, 0.767)), and MEWS (0.704 (95%CI 0.703, 0.704)). eCART's performance remained high (AUROC ≥0.80) across a range of patient demographics, clinical conditions, and during prospective validation. CONCLUSIONS: We developed eCART, which performed better than the NEWS and MEWS retrospectively, prospectively, and across a range of subgroups. These results served as the foundation for Food and Drug Administration clearance for its use in identifying deterioration in hospitalized ward patients.
RESUMO
OBJECTIVE: To evaluate how breast cancers come to clinical attention (mode of detection [MOD]) in a population-based cohort, determine the relative frequency of different MODs, and characterize patient and tumor characteristics associated with MOD. PATIENTS AND METHODS: We used the Rochester Epidemiology Project to identify women ages 40 to 75 years with a first-time diagnosis of breast cancer from May 9, 2017, to May 9, 2019 (n=500) in a 9-county region in Minnesota. We conducted a retrospective medical record review to ascertain the relative frequency of MODs, evaluating differences between screening mammography vs all other MODs by breast density and cancer characteristics. Multiple logistic regression was conducted to examine the likelihood of MOD for breast density and stage of disease. RESULTS: In our population-based cohort, 162 of 500 breast cancers (32.4%) were detected by MODs other than screening mammography, including 124 (24.8%) self-detected cancers. Compared with women with mammography-detected cancers, those with MODs other than screening mammography were more frequently younger than 50 years of age (P=.004) and had higher-grade tumors (P=.007), higher number of positive lymph nodes (P<.001), and larger tumor size (P<.001). Relative to women with mammography-detected cancers, those with MODs other than screening mammography were more likely to have dense breasts (odds ratio, 1.87; 95% CI, 1.20 to 2.92; P=.006) and advanced cancer at diagnosis (odds ratio, 3.58; 95% CI, 2.29 to 5.58; P<.001). CONCLUSION: One-third of all breast cancers in this population were detected by MODs other than screening mammography. Increased likelihood of nonmammographic MODs was observed among women with dense breasts and advanced cancer.