Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Acta Chir Belg ; : 1-8, 2022 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-36346005

RESUMO

BACKGROUND: The SARS-CoV-2 (COVID-19) pandemic required a rapid surge of healthcare capacity to face a growing number of critically ill patients. For this reason, a support reserve of physicians, including surgeons, were required to be reassigned to offer support. OBJECTIVE: To realize a survey on the educational programs deployed (face-to-face or e-learning focusing on infective area, basic gestures, COVID clinical management and intensive care medicine), and their impact on behavior change (Kirkpatrick 3) of the target population of surgeons, measured on a five modalities Likert scale. DESIGN: Cross-sectional online e-survey (NCT04732858) within surgeons from the Assistance Publique - Hôpitaux de Paris network, metropolitan area of Paris, France. RESULTS: Cross-sectional e-Survey: among 382 surgeons invited, 37 (9.7%) participated. The effectiveness of the educational interventions on behavior changes was rated within the highest region of the Likert scale by 15% (n = 3) and 22% (n = 6) for 'e-learning' and 'face-to-face' delivery modes, respectively. CONCLUSIONS: Despite the low response rate, this survey suggests an overall low impact on behaviour change among responders affiliated to a surgical discipline.

2.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2305-2311, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32902686

RESUMO

PURPOSE: The purpose was to evaluate the clinical and radiological results of knotless repair with flat-braided suture in full small-sized supraspinatus tendon tears (< 1 cm). METHODS: A consecutive series of 54 patients with isolated small supraspinatus tendon tear (< 1 cm and Goutallier index < 2) was evaluated in the study. Patients underwent a knotless arthroscopic repair using flat-braided suture (2 mm wide). Minimal follow-up required was 5 years. Changes in Murley-Constant score, ASES score, strength, and pain relief were assessed. The Sugaya score was used to confirm the tendon repair on MRI. Data were analyzed in two subgroups: technique with additional U point for dog ear deformity (group 1) and technique without additional U point (group 2). The immobilization period was 3 weeks long. Passive mobilization was immediate. RESULTS: Fifty-four patients were included. Mean age was 57 ± 4 years. The average follow-up was 68 ± 10 months. Average preoperative score of Constant was 51.2 ± 8.5 and 83.1 ± 14.6 at the end of the follow-up (p < 0.001). Mean VAS went from 5.8 ± 1.8 to 1.9 ± 2.1 (p < 0.001). Average forward elevation of the shoulder went from 86.3° ± 9 preoperatively to 169.6° ± 15.9 at the end of the follow-up (p < 0.001). The strength score was significantly higher post-operatively (18.4 vs. 8.3, p < 0.001.). The ASES score was significantly improved 49.1 ± 13.1 vs. 88.6 ± 15.8, p < 0.001). The MRI assessment revealed 94% of Sugaya 1-2. No significant difference was observed between group 1 and 2 regarding all clinical outcomes. Two complex regional pain syndromes were described with a favorable evolution. Three patients presented a retear requiring an iterative arthroscopic repair. CONCLUSION: The use of a knotless arthroscopic construct with flat-braided suture for small supraspinatus repair achieved excellent structural and clinical results. This technique is fully adequate for the arthroscopic treatment of such tears, enabling early mobilization. LEVEL OF EVIDENCE: Level III.


Assuntos
Artroscopia/métodos , Lesões do Manguito Rotador/cirurgia , Técnicas de Sutura , Traumatismos dos Tendões/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico por imagem , Ombro/diagnóstico por imagem , Ombro/fisiopatologia , Ombro/cirurgia , Dor de Ombro/epidemiologia , Traumatismos dos Tendões/diagnóstico por imagem , Tendões/cirurgia , Resultado do Tratamento
3.
Int Orthop ; 45(11): 2917-2926, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34554308

RESUMO

PURPOSE: The aim of this study was (1) to compare clinical and radiological outcomes of 3- and 4-part proximal humeral fractures using either IMN or LP (2) and to report complications related to each technique. METHODS: A prospective controlled randomized open-label two-arm study was performed. Ninety-nine consecutive adult patients with a 3- and 4-part displaced acute proximal humeral fractures were randomized to be treated with IMN (n = 49) or LP (n = 50). Constant, ASES and SST scores were recorded by the surgeon. Range of motion was evaluated. A visual analog scale (VAS) was used to assess shoulder pain. Complications and revision surgeries were reported. RESULTS: Eighty-five patients were analyzed, nine were lost, and five died during the follow-up period. The mean age was 73.7 years (± 13.3,, and the mean follow-up was 66 months (± 13.5). At last follow-up, VAS was lower in the IMN group (0.9 (± 1.1) vs. 1.9 (± 1.7), p = 0.001). The median Constant score was significantly higher in the IMN group (81.6 (± 10.9) points) vs. in the LP group (75.6 (± 19.5) points) (p = 0.043), and ASES score was also significantly higher in the IMN group (86.3 (± 9.5) vs. 75.2 (± 19.6), p = 0.001). There was no difference in the range of motion or SST scores between the two groups. Complications were seen higher in the LP group (9 (21%) vs. 22 (52%), p = 0.003). Revision surgery was higher in the LP group (37% vs. 21%). CONCLUSION: Satisfactory results were accomplished in both groups according to the reported clinical outcomes. Complication and revision rates were higher in LP group.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Úmero , Fraturas do Ombro , Adulto , Idoso , Placas Ósseas , Fixação Interna de Fraturas , Fixação Intramedular de Fraturas/efeitos adversos , Humanos , Estudos Prospectivos , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Resultado do Tratamento
4.
Arch Orthop Trauma Surg ; 141(5): 795-801, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32451618

RESUMO

PURPOSE: Although shoulder arthroplasty is relatively safe in general population, it remains unclear in transplant recipient. Aim of this study was to determine outcomes and morbidity after shoulder arthroplasty in lung transplant recipients. METHODS: A retrospective analysis was performed at our university hospital center from 2001 to 2015. Main inclusion criterion was all lung transplant recipient who underwent shoulder arthroplasty. Clinical outcomes including Constant score, visual analogue scale (VAS), American Shoulder and Elbow Surgeons score (ASES) were determined in pre-operative period and a minimum follow-up of 36 months. Special attention was taken about complications. RESULTS: Among 700 lung transplant recipients, we identified 12 patients who underwent 14 shoulder arthroplasties. Arthroplasties were performed after proximal humeral avascular necrosis (n = 10), degenerative osteoarthritis (n = 1) and non-union of proximal humeral fracture (n = 1). 8 anatomical total shoulder arthroplasties and 6 reversed shoulder arthroplasties were performed. Mean follow-up was 61.4 months (± 22.1). Mean age was 47.1 (± 9.3) years. All patients had immunosuppression therapy at the time of surgery. Mean Constant score was improved at last follow-up [43(± 9.7) vs 94(± 4), p < 0.001]. VAS decreased from 6.4 (± 1.2) to 0.4 (± 0.8), p < 0.001. Mean ASES was improved from 33 (± 6) to 91 (± 5) at last follow-up (p < 0.001). Range of motion were improved between early post-operative evaluation and last follow-up: forward flexion: 85° (± 8°) vs 119°(± 13°); abduction: 83° (± 14°) vs 106°(± 23°); external rotation (RE1): 26° (± 7°) vs 36°(± 10°). At last follow-up, one revision was required for humeral prothesis loosening at 2 years post-surgery. One patient died due to acute pulmonary decompensation on chronic rejection 66 months after shoulder arthroplasty. CONCLUSION: Shoulder arthroplasty is a safe procedure in this vulnerable population of lung transplant recipients. Such results encourage us to continue arthroplasty surgery when required. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia do Ombro , Segurança do Paciente , Articulação do Ombro/cirurgia , Transplantados , Adulto , Humanos , Transplante de Pulmão , Pessoa de Meia-Idade , Amplitude de Movimento Articular/fisiologia
5.
J Shoulder Elbow Surg ; 29(6): 1197-1205, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31812588

RESUMO

BACKGROUND: Reverse shoulder arthroplasties have progressed in recent decades to become the most popular type of arthroplasty. Short stems with metaphyseal fixation have been developed to preserve bone stock and facilitate possible revision. Accurate positioning of these implants can be challenging using the superolateral approach. OBJECTIVE: This study aimed to evaluate the clinical and radiologic results of reverse short-stem arthroplasties using a superolateral approach with a minimum of 2 years' follow-up. METHODS: Between January 2015 and December 2016, a total of 76 patients underwent reverse shoulder arthroplasty surgery (79 shoulders) using a short uncemented humeral stem for shoulder arthritis with irreparable rotator cuff tear. Arthroplasties for post-traumatic osteoarthritis were excluded. Functional outcomes were assessed using Constant Score, American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), visual analog scale (VAS), and range of motion. Radiographic analysis was used to evaluate component loosening, implant position, and implant filling ratio. RESULTS: The mean age was 70.8 years. At a mean of 38.8-month follow-up, there were significant improvements in Constant score (44.2 to 87.9, P < .001), ASES score (36.2 to 84.3, P < .001), and VAS score (6.8 to 0.4, P < .001). Forward flexion improved from 89°to 131°(P < .001), and external rotation improved from 25° to 36°(P < .001). No evidence of periprosthetic loosening was visible. Mean varus of the humeral stem was 1°(±6°). The mean glenoidal inclination was 98°(±7°), which corresponds to a lower tilt of 8°. The average filling ratio was between 50% and 60% in both the metaphysis and the diaphysis. CONCLUSION: The clinical results obtained in this study were satisfying, with a significantly low complication rate. Hence, short-stem reverse shoulder arthroplasty using a superolateral approach, while taking particular care to protect the deltoid, remains our method of choice.


Assuntos
Artroplastia do Ombro/métodos , Prótese de Ombro , Idoso , Artroplastia do Ombro/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Rotação , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Escala Visual Analógica
7.
Eur J Orthop Surg Traumatol ; 28(7): 1321-1326, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29704127

RESUMO

BACKGROUND: Screw-plates disassembly incidence after pertrochanteric fracture (PF) amounts to 1 and 16% among the elderly population. The main occurrence is early cervical screw cut-out. The population at highest risk of disassembly remains difficult to identify. The correlation between femoral offset loss and disassembly occurrence has never been surveyed. OBJECTIVES: A radiological prognosis score for screw plate disassembly was defined to reflect trochanteric impaction (TI); it was based on a femoral offset ratio. STUDY DESIGN AND METHODS: Our single-centre retrospective case-control study surveyed patients suffering from Dynamic Hip Screw (DHS, Synthes®) disassembly following osteosynthesis of non-pathological osteoporotic PF between 2004 and 2014. All cases were categorised by age and gender and paired to three patients in the control group. The primary endpoint was TI measurement, corresponding to offset loss on the operated hip compared to healthy hip offset and expressed as a percentage. The measurement was done on an immediate postoperative X-ray. The secondary endpoints were tip apex distance (TAD) measurement, Ender and AO classifications, as well as postoperative weight-bearing prescription. RESULTS: Twenty-three cases and 69 controls were surveyed. The case group's average age was 87; 70% of the cases were women. The main disassembly occurrence delay was after 27 days. Average TI was 26% within the patients global group and 12% within the control group (p < 10-5). Over a 21% impaction percentage, disassembly occurrence represents a greater risk: OR = 21.95% CI [5.4-104.3], p < 10-5. Ender 3 type fractures were the most frequent indication for surgery within the case group. Average TAD was 20 mm within the case group, and 17 mm within the control group (p = 0.03). The weight-bearing prescription rate was 52% within the control group and 21% within the case group (p = 0.014). 14.5% of the control group had a TI > 21%. CONCLUSIONS: Using the offset ratio tool, TI measurement was associated with a greater risk of DHS disassembly when it was higher than 21%. The exclusive use of a DHS device does not seem optimal for a TI > 21%. Weight-bearing may be prescribed for all the patients with a TI < 21%, provided good implant positioning is secured.


Assuntos
Placas Ósseas/efeitos adversos , Parafusos Ósseos/efeitos adversos , Fixação Interna de Fraturas/efeitos adversos , Fraturas do Quadril/cirurgia , Fraturas por Osteoporose/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Fraturas do Quadril/diagnóstico por imagem , Humanos , Masculino , Fraturas por Osteoporose/diagnóstico por imagem , Prognóstico , Falha de Prótese , Estudos Retrospectivos
8.
Neuroimage ; 124(Pt B): 1188-1195, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26364860

RESUMO

Neuroimaging has been facing a data deluge characterized by the exponential growth of both raw and processed data. As a result, mining the massive quantities of digital data collected in these studies offers unprecedented opportunities and has become paramount for today's research. As the neuroimaging community enters the world of "Big Data", there has been a concerted push for enhanced sharing initiatives, whether within a multisite study, across studies, or federated and shared publicly. This article will focus on the database and processing ecosystem developed at the Montreal Neurological Institute (MNI) to support multicenter data acquisition both nationally and internationally, create database repositories, facilitate data-sharing initiatives, and leverage existing software toolkits for large-scale data processing.


Assuntos
Bases de Dados Factuais , Disseminação de Informação , Neuroimagem , Comportamento , Genômica , Humanos , Estudos Longitudinais , Controle de Qualidade , Software
9.
J Arthroplasty ; 31(10): 2308-13, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27235329

RESUMO

BACKGROUND: This study compared 2- and 3-dimensional (2D and 3D) radiographic measurements of anatomical and functional leg length and knee coronal and sagittal alignments and correlated these measurements with patients' leg-length perceptions. METHODS: Patients without symptomatic spinal pathology, previous surgery of the spine, and lower extremities (140 lower extremities) were evaluated on EOS images obtained in standing position. Numerous measurements of each limb were compared to the contralateral limb. All 2D/3D measures were evaluated and compared for repeatability and reproducibility. RESULTS: Mean 2D functional and anatomical lengths were 78.7 cm (64.7-88.4, confidence interval [CI] 95%: 77.4-80) and 78.3 cm (64.9-87.9, CI 95%: 77-79.6), respectively. Mean 3D functional and anatomical lengths were 78.9 cm (65.1-88.7, CI 95%: 77.6-80.2) and 78.9 cm (65.6-88.3, CI 95%: 77.8-80.5), respectively (P < .001). Mean 2D and 3D knee varus/valgus angles were -1.9° (-26.4 to 9.1, CI 95%: -3.5 to -0.7) and -0.9° (-19.2 to 11.8, CI 95%: -2.4 to 0.2), respectively (P = .004). Multiple regression analysis found that patients with >10° of flexum/recurvatum were 2.1× more likely to perceive unequal length (P < .1). Patients with irreducible varus/valgus knee deformity were 4× more likely to perceive unequal length (P < .04). CONCLUSION: EOS imaging allows more accurate assessment of anatomical and functional lengths. Patients' perceptions of lower extremity length may correlate more closely with coronal and sagittal alignments of the knee than with femoral or tibial length. This study highlights the importance of physical examination of all the joints and 3D measurements in functional standing position.


Assuntos
Imagem Corporal , Imageamento Tridimensional/estatística & dados numéricos , Desigualdade de Membros Inferiores/diagnóstico por imagem , Radiografia/métodos , Fêmur/diagnóstico por imagem , Humanos , Desigualdade de Membros Inferiores/psicologia , Extremidade Inferior , Análise Multivariada , Percepção , Postura , Estudos Prospectivos , Radiografia/estatística & dados numéricos , Análise de Regressão , Reprodutibilidade dos Testes , Coluna Vertebral , Tíbia/diagnóstico por imagem
10.
Eur J Orthop Surg Traumatol ; 26(7): 713-24, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27573076

RESUMO

Lumbar stenosis is frequently observed and treated by spine surgeons. The extent of neurological decompression and the potential spinal fixation are the basic concerns when surgery is planned. But this segmented approach to the problem is sometimes insufficient due to the complex functional situations induced by a sagittal imbalance of the patient and the combination of pathologies known as hip-spine or knee-spine syndromes. A total of 373 consecutive patients included from our EOS and clinical data base. Patients were divided in two groups. Group A included patients presenting exclusive spinal issues (172 cases) out of whom 117 (68 %) had sagittal imbalance. Among 201 patients with associated lower limbs issues (group B), 122 (61 %) had sagittal imbalance. The perception of imbalance was noticed in 54 % (93 cases) in group A and 57 % (115 cases) in group B. In the global series of 239 imbalanced cases, the key point was a spine issue for 165 patients (the 117 patients with only spine problems and 48/122 cases with combined spine and lower limbs problems). But in the patients with combined spine and lower limbs problems, we individualized hip-spine syndromes (24/122 patients) and knee-spine syndromes (13/122 patients). In some cases, (37/122 patients) the anatomical and functional situations were more complex to characterize a spine-hip or a hip-spine problem. The EOS full-body images provide new information regarding the global spinal and lower limbs alignment to improve the understanding of the patient functional posture. This study highlights the importance of the lower limb evaluation not only as compensatory mechanism of the spinal problems but also as an individualized parameter with its own influence on the global balance analysis. Level of evidence IV diagnostic case series.


Assuntos
Equilíbrio Postural , Transtornos de Sensação/etiologia , Estenose Espinal/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Extremidade Inferior , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Percepção , Equilíbrio Postural/fisiologia , Postura/fisiologia , Transtornos de Sensação/fisiopatologia , Estenose Espinal/complicações , Estenose Espinal/fisiopatologia , Imagem Corporal Total/métodos
11.
Int Orthop ; 39(7): 1259-67, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25522799

RESUMO

PURPOSE: Accurate evaluation of femoral offset is difficult with conventional anteroposterior (AP) X-rays. The EOS imaging system is a system that makes the acquisition of simultaneous and orthogonal AP and lateral images of the patient in the standing position possible. These two-dimensional (2D) images are equivalent to standard plane X-rays. Three-dimensional (3D) reconstructions are obtained from these paired images according to a validated protocol. This prospective study explores the value of the EOS imaging system for comparing measurements of femoral offset from these 2D images and the 3D reconstructions. METHODS: We included 110 patients with unilateral total hip arthroplasty (THA). The 2D offset was measured on the AP view with the same protocol as for standard X-rays. The 3D offset was calculated from the reconstructions based on the orthogonal AP and lateral views. Reproducibility and repeatability studies were conducted for each measurement. We compared the 2D and 3D offset for both hips (with and without THA). RESULTS: For the global series (110 hips with and 110 without THA), 2D offset was 40 mm (SD 7.3; 7-57 mm). The standard deviation was 6.5 mm for repeatability and 7.5 mm for reproducibility. Three-dimensional offset was 43 mm (SD 6.6; 22-62 mm), with a standard deviation of 4.6 for repeatability and 5.5 for reproducibility. Two-dimensional offset for the hips without THA was 40 mm (SD 7.0; 26-56 mm), and 3D offset 43 mm (SD 6.6; 28-62 mm). For THA side, 2D offset was 41 mm (SD 8.2; 7-57 mm) and 3D offset 45 mm (SD 4.8; 22-61 mm). Comparison of the two protocols shows a significant difference between the 2D and 3D measurements, with the 3D offset having higher values. Comparison of the side with and without surgery for each case showed a 5-mm deficit for the offset in 35 % of the patients according to the 2D measurement but in only 26 % according to the 3D calculation. CONCLUSIONS: This study points out the limitations of 2D measurements of femoral offset on standard plane X-rays. The reliability of the EOS 3D models has been previously demonstrated with CT scan reconstructions as a reference. The EOS imaging system could be an option for obtaining accurate and reliable offset measurements while significantly limiting the patient's exposure to radiation.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Imageamento Tridimensional/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Postura , Estudos Prospectivos , Radiografia , Reprodutibilidade dos Testes
12.
Eur J Orthop Surg Traumatol ; 25 Suppl 1: S155-65, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25845316

RESUMO

UNLABELLED: Simulating compressive action of muscles, a follower load attends to reproduce a more physiological biomechanical behaviour of the cervical spine. Only few experimental studies reported its influence on kinematics and intradiscal pressure in the cervical spine. STUDY DESIGN: In vitro human cadaveric and numerical simulating evaluation of a compressive preload in the cervical spine. OBJECTIVES: To analyse the influence of a compressive follower preload on the biomechanical behaviour of the cervical spine. METHODS: The present study was divided into two parts: part 1: in vitro investigation; part 2: numerical simulating analysis. Part 1: Twelve human cadaveric spines from C2 to T2 were evaluated intact and after application of a 50-N follower load. All tests were performed under load control by applying pure moments loading of 2 Nm in flexion/extension (FE), axial rotation (AR) and lateral bending (LB). Three-dimensional displacements were measured using an optoelectronic system, and intradiscal pressures were measured at two levels. Part 2: Using a 3D finite element model, we evaluated the influence of a 50- and 100-N compressive preload on intradiscal loads, facets forces and ranges of motion. Different positions of the follower load along the anteroposterior axis (±5 mm) were also simulated. RESULTS: Part 1: Mean variation of cervical lordosis was 5° ± 3°. The ROM slightly increased in FE, whereas it consistently decreased in AR and LB. Coupled lateral bending during AR was also reduced. Increase in hysteresis was observed on load-displacement curves only for AR and LB. Intradiscal pressures increased, but the aspect of load-pressure curves was altered in AR and LB. Part 2: Using the FE model, only minimal changes in ROM were noted following the simulation of a 50-N compressive load for the three loading conditions. Compared to intact condition, <10% variation was observed with regard to the different magnitude and positioning simulated. Intradiscal loads and facets forces were systematically increased by applying compressive preload. CONCLUSIONS: Although the follower load represents an attractive option to apply compressive preload during experimental tests, we found that this method could affect the native biomechanical behaviour of spine specimen depending on which movement was considered. Only minimal effects were observed in FE, whereas significant changes in kinematics and intradiscal pressures were observed for AR and LB.


Assuntos
Vértebras Cervicais/fisiologia , Disco Intervertebral/fisiologia , Suporte de Carga/fisiologia , Idoso , Fenômenos Biomecânicos , Cadáver , Vértebras Cervicais/diagnóstico por imagem , Simulação por Computador , Feminino , Humanos , Imageamento Tridimensional , Disco Intervertebral/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Pressão , Radiografia , Amplitude de Movimento Articular , Rotação , Estresse Mecânico
13.
J Spinal Disord Tech ; 27(3): 166-73, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24945294

RESUMO

DESIGN: Retrospective study of radiologic records of patients who underwent lumbar pedicle subtraction osteotomy (PSO) procedures. OBJECTIVE: To evaluate the restoration of spinal balance above and below the osteotomy site after PSO for various causes. SUMMARY OF BACKGROUND DATA: The normal sagittal balance of the spine has been widely documented. Sagittal imbalance can be surgically treated with vertebral osteotomy. Reports have described its technical aspects and local radiologic results. Less is known about the spontaneous rebalancing of the spine cranially and caudally to the osteotomy site. METHODS: The French Scoliosis Study Group conducted a multicenter retrospective study from the records of a combined cohort of 356 patients. Spinal balance after PSO was assessed radiologically. In this study, we focused specifically on measuring the reorientation of the pelvis and upper thoracic segments and investigated the influence of pelvic incidence, osteotomy level, and regional lordosis gain. The population was classified according to the indication for the procedure: posttraumatic deformity, degenerative kyphosis, scoliosis, or ankylosing spondylarthritis. RESULTS: The average regional lordosis gain was 26.1 degrees. In the degenerative kyphosis and scoliosis groups, the level of osteotomy and the incidence angle tended to influence pelvic adaptation (better balance of the caudal portion was associated with low-level PSO and low-incidence angle). The posttraumatic deformity cases had a specific pattern: balance changes after PSO were limited to the local lordosis gain, with less pelvic and thoracic reorientation, probably due to spinal flexibility. On the contrary, the spondylarthritis cases showed less pelvic and more thoracic reorientation, probably due to hip and spinal stiffness. CONCLUSIONS: Better knowledge from a large series of the overall spontaneous spinal balance after PSO and the pelvic/thoracic reorientation would be useful for preoperative planning of lumbar osteotomies and predicting pelvic and hip reorientation. LEVEL OF EVIDENCE: Level II.


Assuntos
Parafusos Ósseos , Vértebras Lombares/cirurgia , Osteotomia/métodos , Pelve/fisiopatologia , Pelve/cirurgia , Equilíbrio Postural/fisiologia , Vértebras Torácicas/fisiopatologia , Vértebras Torácicas/cirurgia , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Pelve/diagnóstico por imagem , Radiografia , Doenças da Coluna Vertebral/fisiopatologia , Doenças da Coluna Vertebral/cirurgia , Vértebras Torácicas/diagnóstico por imagem , Resultado do Tratamento
14.
Eur J Orthop Surg Traumatol ; 24(6): 891-5, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23942777

RESUMO

PURPOSE: A source of radiological bias occurs when the axial rotation of the pelvis is disregarded in hip and spine biomechanics analyses. The EOS imaging system (EOS Imaging, France) offers the possibility of detecting and measuring the axial rotation of bones. Reproducibility and accuracy have not been documented in the case of the pelvis. METHODS: A dry pelvis has been X-rayed with the EOS system every 5° from 30° left to 30° right according to a laser line reference goniometer. Three observers have measured the rotation. One observer did it 3 times. The intra- and inter-observer reproducibility and the accuracy have been calculated using the root mean square standard deviation calculation. The relationship between the axial rotation and the offset between the left and right acetabulae on the lateral view was investigated. RESULTS: The 95 % CI was ±0.23° for the intra-observer and ±0.33° for the inter-observer reliability. The mean of signed differences between the software calculation and the actual axial rotation of the pelvis was -0.39° (SD 0.77°). The lateral acetabular offset was proportional to the sin of the rotation. Approximately, 30 mm offset corresponded to about 10° rotation. CONCLUSIONS: The 3D slot scanning imaging system demonstrated significant reproducibility and accuracy for the assessment of the axial rotation of the pelvis.


Assuntos
Ossos Pélvicos/diagnóstico por imagem , Rotação , Acetábulo/diagnóstico por imagem , Artrometria Articular , Fenômenos Biomecânicos , Feminino , Humanos , Imageamento Tridimensional/instrumentação , Pessoa de Meia-Idade , Variações Dependentes do Observador , Ossos Pélvicos/fisiologia , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Reprodutibilidade dos Testes
15.
J Leukoc Biol ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38952292

RESUMO

The absolute lymphocyte count (ALC), lymphocyte-to-monocyte ratio (LMR), and neutrophil-to-lymphocyte ratio (NLR) offer convenient means to assess systemic inflammation post-cancer treatment, which influences treatment outcomes. Understanding these biomarker variations and leukocyte subpopulation interplay is crucial for optimizing radiotherapy. Herein, leukocyte subpopulations (T-CD4+, T-CD8+, B-cells, NK-cells, neutrophils, monocytes) during and after brain irradiation (using X-rays or Protons) in tumor-free mice were used to compute ALC, LMR, and NLR, on which radiation parameter influence was assessed by principal component analysis (PCA). NLR kinetics were further examined using modeling. Leukocyte subpopulations interplays and their response to radiation parameters were examined using PCA and correlation analysis. Under X-rays, ALC and LMR decreased, with ALC recovered to baseline after irradiation, but not LMR. Both X-rays and protons increased the NLR during irradiation, recovering in protons but not X-rays. Both irradiation volume and dose rate had a pronounced effect on the NLR. Leukocyte subpopulation interplay was observed under X-rays and protons, normalizing in the proton group by day 28. Lymphopenia was observed in all lymphocyte subpopulations under X-ray irradiation but not protons. The recovery patterns varied among the subpopulations. Neutrophil counts increased during irradiation, with the recovery of protons, but not X-rays, by day 28. Interplays between NK-cells and myeloid subpopulations were evident under X-rays but not protons. Importantly, no interplay was detected between myeloid cells and T/B-cells, indicating that LMR and NLR variations were primarily due to independent responses to brain irradiation. A tumor-free experimental mouse model was used to study the effects of brain radiotherapy on systemic immunity. When administering fractionated irradiation with a total dose of 20 Gy using a vertical beam to either the whole brain or hemi-brain, proton irradiation had fewer adverse impacts on the immune system compared to X-rays in tumor-free rodents.

16.
Orthop Traumatol Surg Res ; 110(3): 103815, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38246492

RESUMO

INTRODUCTION: The arthroscopic bone block has shown reliability and reproducibility regarding functional scores and shoulder mobility compared to the open bone block technique. The recovery of muscle strength, especially the strength ratio external rotator/internal rotator (ER/IR), is crucial to recovering satisfactory function. This ratio should be as near to 1 as possible, meaning a good strength balance. Little is known about the difference in strength recovery between the open and arthroscopic techniques. HYPOTHESIS: Arthroscopic Latarjet reduces surgical stress and improves the strength recovery and strength ratio. OBJECTIVES: To compare arthroscopic and open Latarjet procedures for shoulder muscle strength and functional outcomes. MATERIAL AND METHODS: It was an observational longitudinal and prospective cohort follow-up. Two groups of patients were accessible for comparison: 35 in an arthroscopy group and 38 in an open group. The main outcome was the muscle strength of shoulder muscles measured with a dynamometer and expressed in Newton (N) at day 21 (D21), D45, D90, D180, and D365 in the operated and contralateral shoulders. The measurements were made for the pectoralis major, the three deltoid fascicles, and the subscapularis. The shoulder ER/IR strength ratio was calculated. Other variables were the range of motion (ROM), the Walch-Duplay (WD), the Western Ontario Shoulder Instability score (WOSI), and the Visual Analogic Scale for pain assessment. The strength, ROM, and functional scores were compared between open and arthroscopy with linear mixed models. RESULTS: The median strengths at 52 weeks were significantly higher than at 3 weeks (P<10-4): anterior deltoid (AD) 8N (Q1:7, Q3: 9) versus 4N (Q1:2, Q3: 5), lateral deltoid (LD) 9N (Q1:9, Q3: 11) versus 6N (Q1:4, Q3: 7), posterior deltoid (PD) 14N (Q1:12, Q3: 15) versus 9N (Q1:8, Q3: 10), subscapularis 10N (Q1:9, Q3: 12) versus 7N (Q1:5, Q3: 8), and pectoralis major (PM) 11N (Q1:9, Q3: 12) versus 7N (Q1:5, Q3: 10). The overall strengths were lower in the open group compared to the arthroscopy group: AD -2.1N (CI95%[-3.1--1.2], p=0.0005), LD -1.3N (CI95% [-2.4--0.15], p=0.03), PD -0.35N (CI95% [-1-0.9], p=0.52), subscapularis -2.1N (CI95% [-3.3--0.7], p=0.006), and PM -1.4N (CI95% [-2.2--0.02], p=0.03). The ER/IR ratio was stable throughout the follow-up for both the operated and contralateral shoulders (p>0.5). The overall mean ratio was 1.3 (median 1.2, Q1: 1, Q3:1.45) for the operated shoulder and 1.1 (median 1, Q1: 0.9, Q3:1.3) for the contralateral shoulder (p=0.0004). The average ER/IR ratio was 0.27 points higher in the open group (CI95% [0.1-0.46], p=0.003). The ROM was similar between the two groups, and there was no correlation between the ER/IR ratio and the ROM (p>0.5). The VAS < 3 weeks and WD > 12 weeks were significantly poorer in the open group: +0.61 (CI95% [0.03-1.16] p=0.02), and -7.3 points (CI95% [-13--0.01], p=0.05), on average, respectively. CONCLUSION: The patients in the arthroscopy group had a better ER/IR strength ratio (closer to 1) and better WOSI after 12 weeks. The strength and the ROM were not correlated with each other. LEVEL OF EVIDENCE: III.


Assuntos
Artroscopia , Força Muscular , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Articulação do Ombro , Humanos , Artroscopia/métodos , Força Muscular/fisiologia , Masculino , Feminino , Estudos Prospectivos , Amplitude de Movimento Articular/fisiologia , Adulto , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Seguimentos , Pessoa de Meia-Idade , Adulto Jovem , Estudos Longitudinais
17.
World Neurosurg ; 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38679377

RESUMO

BACKGROUND: Anterior cervical corpectomy and fusion achieves foraminal radicular and central medullary decompression and spinal stabilization in staged lesions. Many bone graft materials have been developed for the reconstruction of cervical lordosis and the restoration of intervertebral height after corpectomy. The PolyEtherKetoneEtherKetoneKetone (PEKEKK) is a semicrystalline thermoplastic polymer that can be reinforced with carbon fibers to create long and highly fenestrated rectangular cervical cages for corpectomy. This study aimed to evaluate the radiological outcomes of an innovative PEKEEKK cage compared with others grafting options. METHODS: Forty-five consecutive patients who underwent surgery with PEKEKK cages between 2017 and 2019 at a spine institution, were matched with 15 patients with a titanium mesh cylindrical cage (TMC) and 15 patients with a tricortical structural iliac bone graft. The restoration of vertebral height and cervical lordosis postoperatively, and subsidence of the construct were evaluated. Complications were reported. RESULTS: The minimal follow-up was 5.1±2years. A better, but nonsignificant, postoperative gain in height was observed for PEKEKK (+8.1 ± 20%) and TMC cages (+8.2 ± 16%) than for iliac crest autograft reconstruction (+2.3 ± 15%, P = 0.119). The mean subsidence at the last follow-up was greater for TMC cages (-10.2 ± 13%), but was not significant, with -6.1 ± 10% for PEKEKK cages and -4.1 ± 7% for iliac crest autografts (P = 0.223). The gain in segmental cervical lordosis was significant (P < 0.001) and remained stable in all the groups. CONCLUSIONS: Although an improvement in radiologic anatomical parameters can be achieved with all cage groups, the PEKEKK cage can be considered as a safe alternative for reducing subsidence.

18.
Int J Radiat Biol ; 100(5): 744-755, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38466699

RESUMO

PURPOSES: Lymphopenia is extensively studied, but not circulating leucocyte subpopulations, which however have distinct roles in tumor tolerance. Proton therapy has been shown to have a lesser impact on the immune system than conventional X-ray radiotherapy through lower dose exposure to healthy tissues. We explored the differential effects of brain X-ray and proton irradiation on circulating leucocyte subpopulations. MATERIALS AND METHODS: Leucocyte subpopulation counts from tumor-free mice were obtained 12 hours after 4 fractions of 2.5 Gy. The relationships between irradiation type (X-rays or protons), irradiated volume (whole-brain/hemi-brain) and dose rate (1 or 2 Gy/min) with circulating leucocyte subpopulations (T-CD4+, T-CD8+, B, and NK-cells, neutrophils, and monocytes) were investigated using linear regression and tree-based modeling approaches. Relationships between dose maps (brain, vessels, lymph nodes (LNs)) and leucocyte subpopulations were analyzed and applied to construct the blood dose model, assessing the hypothesis of a direct lymphocyte-killing effect in radiation-induced lymphopenia. RESULTS: Radiation-induced lymphopenia occurred after X-ray but not proton brain irradiation in lymphoid subpopulations (T-CD4+, T-CD8+, B, and NK-cells). There was an increase in neutrophil counts following protons but not X-rays. Monocytes remained unchanged under both X-rays and protons. Besides irradiation type, irradiated volume and dose rate had a significant impact on NK-cell, neutrophil and monocyte levels but not T-CD4+, T-CD8+, and B-cells. The dose to the blood had a heterogeneous impact on leucocyte subpopulations: neutrophil counts remained stable with increasing dose to the blood, while lymphocyte counts decreased with increasing dose (T-CD8+-cells > T-CD4+-cells > B-cells > NK-cells). Direct cell-killing effect of the dose to the blood mildly contributed to radiation-induced lymphopenia. LN exposure significantly contributed to lymphopenia and partially explained the distinct impact of irradiation type on circulating lymphocytes. CONCLUSIONS: Leucocyte subpopulations reacted differently to X-ray or proton brain irradiation. This difference could be partly explained by LN exposure to radiation dose. Further researches and analyses on other biological processes and interactions between leucocyte subpopulations are ongoing. The various mechanisms underlying leucocyte subpopulation changes under different irradiation modalities may have implications for the choice of radiotherapy modalities and their combination with immunotherapy in brain cancer treatment.


Assuntos
Encéfalo , Leucócitos , Animais , Camundongos , Encéfalo/efeitos da radiação , Leucócitos/efeitos da radiação , Linfopenia/etiologia , Relação Dose-Resposta à Radiação , Masculino , Raios X , Terapia com Prótons/efeitos adversos , Camundongos Endogâmicos C57BL
19.
J Spinal Disord Tech ; 26(4): 212-7, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22134734

RESUMO

STUDY DESIGN: Retrospective radiographic and clinical review. OBJECTIVE: To determine the feasibility of iliosacral screw fixation in adult spinal deformations. SUMMARY OF BACKGROUND DATA: Pelvic fixation is one of the most challenging instrumentation problems. The poor bone quality frequently found within the sacrum and the large lumbosacral loads with cantilever pullout forces across this region explain its frequent failure. METHODS: Fourteen adult patients undergoing pelvic fixation using iliosacral screws with a minimal follow-up of 24 months were analyzed for radiographic outcomes. Radiographic data included the localization of the spinal deformity, the Cobb angle, T4-T12 thoracic kyphosis, L1-S1 lumbar lordosis, the T9 tilt, the pelvic parameters, and the POA. Mechanical and infectious complications were also noted. RESULTS: The lumbo-pelvic correction was performed with a large reduction of the POA in every case. The frontal and sagittal corrections obtained with this procedure were considered as being effective. There were no mechanical complications due to failure of the instrumentation, loss of sacral fixation, or loss of lumbar lordosis at the time of the last follow-up. One patient experienced local infection on the left iliosacral screw without any residual functional sequel. DISCUSSION: Iliosacral screwing can offer a pelvic fixation reliable enough to allow restoration of 3-dimensional trunk balance. This technique has a quite short learning curve and adequately permits frontal and sagittal corrections, increases stability, and decreases instrumentation-related complications. Our observations suggest that it is applicable to pelvic fixation in adult surgery.


Assuntos
Parafusos Ósseos , Ílio/cirurgia , Fixadores Internos , Sacro/cirurgia , Curvaturas da Coluna Vertebral/diagnóstico por imagem , Curvaturas da Coluna Vertebral/cirurgia , Fusão Vertebral/instrumentação , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Pelve/cirurgia , Radiografia , Estudos Retrospectivos , Fusão Vertebral/métodos , Resultado do Tratamento , Adulto Jovem
20.
Eur J Orthop Surg Traumatol ; 23(2): 131-43, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23412443

RESUMO

The viscoelastic lumbar disk prosthesis-elastic spine pad (LP-ESP(®)) is an innovative one-piece deformable but cohesive interbody spacer providing 6 full degrees of freedom about the 3 axes, including shock absorption. A 20-year research program has demonstrated that this concept provides mechanical properties very close to those of a natural disk. Improvements in technology have made it possible to solve the problem of the bond between the elastic component and the titanium endplates and to obtain an excellent biostability. The prosthesis geometry allows limited rotation and translation with resistance to motion (elastic return property) aimed at avoiding overload of the posterior facets. The rotation center can vary freely during motion. It thus differs substantially from current prostheses, which are 2- or 3-piece devices involving 1 or 2 bearing surfaces and providing 3 or 5 degrees of freedom. This design and the adhesion-molding technology differentiate the LP-ESP prosthesis from other mono-elastomeric prostheses, for which the constraints of shearing during rotations or movement are absorbed at the endplate interface. Seven years after the first implantation, we can document in a solid and detailed fashion the course of clinical outcomes and the radiological postural and kinematic behavior of this prosthesis.


Assuntos
Disco Intervertebral/cirurgia , Vértebras Lombares/cirurgia , Próteses e Implantes , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Disco Intervertebral/fisiologia , Degeneração do Disco Intervertebral/cirurgia , Vértebras Lombares/fisiologia , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Próteses e Implantes/normas , Amplitude de Movimento Articular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA