RESUMO
In the context of investigating cell-material interactions or of material-guided generation of tissues, DNA quantification represents an elective method to precisely assess the number of cells attached or embedded within different substrates. Nonetheless, nucleic acids are known to electrostatically bind to ceramics, a class of materials commonly employed in orthopaedic implants and bone tissue engineering scaffolds. This phenomenon is expected to lead to a relevant underestimation of the DNA amount, resulting in erroneous experimental readouts. The present work aims at *lpar;i) investigating the effects of DNA-ceramic bond occurrence on DNA quantification, and (ii) developing a method to reliably extract and accurately quantify DNA in ceramic-containing specimens. A cell-free model was adopted to study DNA-ceramic binding, highlighting an evident DNA loss (up to 90%) over a wide range of DNA/ceramic ratios (w/w). A phosphate buffer-based (800 mM) enzymatic extraction protocol was developed and its efficacy in terms of reliable DNA extraction and measurement was confirmed with commonly used fluorometric assays, for various ceramic substrates. The proposed buffered DNA extraction technique was validated in a cell-based experiment showing 95% DNA retrieval in a cell seeding experiment, demonstrating a 3.5-fold increase in measured DNA amount as compared to a conventional enzymatic extraction protocol. In conclusion, the proposed phosphate buffer method consistently improves the DNA extraction process assuring unbiased analysis of samples and allowing accurate and sensitive cell number quantification on ceramic containing substrates.
Assuntos
Cerâmica/química , DNA/análise , Sistema Livre de Células , Próteses e Implantes , Reprodutibilidade dos Testes , Engenharia Tecidual/métodosRESUMO
By enabling the maintenance of controlled chemical and physical environmental conditions, bioreactors proved that electro-mechanical stimulation improves tissue development in vitro, especially in the case of tissues which are subjected to stimuli during embryogenesis and growth (i.e. skeletal and cardiac muscle tissue). However, most of the bioreactors developed in the last 20 yrs, designed to suit specific applications, lack versatility. With the aim to provide researchers with a yielding, versatile tool, we designed and realized in this study an electro-mechanical stimulator capable of dynamically culturing four biological constructs, delivering assignable stretching and electrical stimulation patterns. The device has been conceived to be easy to handle and customizable for different applications, while ensuring sterility along with stimuli delivery. The gripping equipment, modular and adaptable to scaffolds of different consistencies, is provided with dedicated tools for supporting sample insertion into the culture chamber performed under a laminar flow hood. As to performance, a wide range of electro-mechanical stimulation patterns and their relative occurrence can be accomplished, permitting the adjustment of the dynamic culture parameters both to the specific cell species and to the developmental phase of the cultured cells.
RESUMO
Native tissues are characterized by spatially organized three-dimensional (3D) microscaled units which functionally define cells-cells and cells-extracellular matrix interactions. The ability to engineer biomimetic constructs mimicking these 3D microarchitectures is subject to the control over cell distribution and organization. In the present study we introduce a novel protocol to generate 3D cell laden hydrogel micropatterns with defined size and shape. The method, named photo-mold patterning (PMP), combines hydrogel micromolding within polydimethylsiloxane (PDMS) stamps and photopolymerization through a recently introduced biocompatible ultraviolet (UVA) activated photoinitiator (VA-086). Exploiting PDMS micromolds as geometrical constraints for two methacrylated prepolymers (polyethylene glycol diacrylate and gelatin methacrylate), micrometrically resolved structures were obtained within a 3 min exposure to a low cost and commercially available UVA LED. The PMP was validated both on a continuous cell line (human umbilical vein endothelial cells expressing green fluorescent protein, HUVEC GFP) and on primary human bone marrow stromal cells (BMSCs). HUVEC GFP and BMSCs were exposed to 1.5% w/v VA-086 and UVA light (1 W, 385 nm, distance from sample = 5 cm). Photocrosslinking conditions applied during the PMP did not negatively affect cells viability or specific metabolic activity. Quantitative analyses demonstrated the potentiality of PMP to uniformly embed viable cells within 3D microgels, creating biocompatible and favorable environments for cell proliferation and spreading during a seven days' culture. PMP can thus be considered as a promising and cost effective tool for designing spatially accurate in vitro models and, in perspective, functional constructs.
Assuntos
Hidrogel de Polietilenoglicol-Dimetacrilato/química , Fotoquímica/métodos , Engenharia Tecidual/instrumentação , Alicerces Teciduais/química , Proliferação de Células , Células Endoteliais da Veia Umbilical Humana/citologia , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato/síntese química , Células-Tronco Mesenquimais/citologia , Polimerização/efeitos da radiaçãoRESUMO
Skeletal myogenesis is a complex process, which is known to be intimately depending on an optimal outside-in substrate-cell signaling. Current attempts to reproduce skeletal muscle tissue in vitro using traditional scaffolds mainly suffer from poor directionality of the myofibers, resulting in an ineffective vectorial power generation. In this study, we aimed at investigating skeletal myogenesis on novel biodegradable microfibrous scaffolds made of DegraPol, a block polyesterurethane previously demonstrated to be suitable for this application. DegraPol was processed by electrospinning in the form of highly orientated ("O") and nonorientated ("N/O") microfibrous meshes and by solvent-casting in the form of nonporous films ("F"). The effect of the fiber orientation at the scaffold surface was evaluated by investigating C2C12 and L6 proliferation (via SEM analysis and alamarBlue test) and differentiation (via RT-PCR analysis and MHC immunostaining). We demonstrated that highly orientated elastomeric microfibrous DegraPol scaffolds enable skeletal myogenesis in vitro by aiding in (a) myoblast adhesion, (b) myotube alignment, and (c) noncoplanar arrangement of cells, by providing the necessary directional cues along with architectural and mechanical support.
Assuntos
Materiais Biocompatíveis/química , Desenvolvimento Muscular , Poliésteres/química , Poliuretanos/química , Animais , Adesão Celular , Linhagem Celular , Desenho de Equipamento , Teste de Materiais , Camundongos , Músculo Esquelético/metabolismo , Mioblastos/metabolismo , Ratos , Engenharia Tecidual/métodosRESUMO
We compared the electrophysiological responses to serotonin (5-HT) of neonatal and juvenile rat hypoglossal motoneurons (HMs) by using intracellular recording techniques in a brainstem slice preparation. In neonatal HMs (=P8), 5-HT caused a substantial decrease in the amplitude of spike afterhyperpolarization (AHP) that was associated with an increase in the minimal repetitive firing frequency (Fmin). Previous work has shown that this effect of 5-HT was mediated by the 5-HT1A receptor and may be secondary to inhibition of N- and P/Q-type calcium channels. In contrast to results from neonates, we found that 5-HT did not inhibit the AHP in juvenile HMs (>/= P20). Application of a cocktail of calcium channel toxins (omega-Conotoxin-GVIA and omega-Agatoxin-IVA) to juvenile HMs substantially inhibited the AHP, indicating that calcium entry through N- and P/Q-type channels supports the AHP in juvenile HMs, as it does in neonates. In addition, intracellular injection of the long-lasting GTP analog GTPgammaS induced an agonist-independent increase in Fmin similar to that seen in neonates in the presence of 5-HT. Together, these results suggested that intracellular mechanisms downstream of the 5-HT1A receptor capable of inhibiting the AHP were intact in juvenile HMs. Therefore, we investigated the possibility that age-related changes in effects of 5-HT on the AHP resulted from altered expression of the 5-HT1A receptor. To this end, we performed ligand-binding autoradiography using [3H]8-OH-DPAT, a 5-HT1A agonist, and in situ hybridization using radiolabeled oligonucleotide probes specific for the 5-HT1A receptor. The two approaches gave remarkably similar results. The highest levels of 5-HT1A receptor expression were found in neonatal HMs, with maximal binding and hybridization at approximately postnatal day 7 (P7) and only low levels of receptor expression by P28. Finally, immunohistochemistry for 5-HT revealed that these developmental changes in 5-HT1A receptor expression occurred coincident with a postnatal increase in serotonergic innervation of the hypoglossal nucleus (nXII). Together, these findings indicate that developmental changes occur in the serotonergic innervation of nXII and in the expression of 5-HT1A receptors in HMs during the early postnatal period, resulting in markedly different effects of 5-HT on firing behavior in neonatal and juvenile HMs.