Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 148(10): 808-818, 2023 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-37463608

RESUMO

BACKGROUND: In hypertrophic cardiomyopathy (HCM), myocyte disarray and microvascular disease (MVD) have been implicated in adverse events, and recent evidence suggests that these may occur early. As novel therapy provides promise for disease modification, detection of phenotype development is an emerging priority. To evaluate their utility as early and disease-specific biomarkers, we measured myocardial microstructure and MVD in 3 HCM groups-overt, either genotype-positive (G+LVH+) or genotype-negative (G-LVH+), and subclinical (G+LVH-) HCM-exploring relationships with electrical changes and genetic substrate. METHODS: This was a multicenter collaboration to study 206 subjects: 101 patients with overt HCM (51 G+LVH+ and 50 G-LVH+), 77 patients with G+LVH-, and 28 matched healthy volunteers. All underwent 12-lead ECG, quantitative perfusion cardiac magnetic resonance imaging (measuring myocardial blood flow, myocardial perfusion reserve, and perfusion defects), and cardiac diffusion tensor imaging measuring fractional anisotropy (lower values expected with more disarray), mean diffusivity (reflecting myocyte packing/interstitial expansion), and second eigenvector angle (measuring sheetlet orientation). RESULTS: Compared with healthy volunteers, patients with overt HCM had evidence of altered microstructure (lower fractional anisotropy, higher mean diffusivity, and higher second eigenvector angle; all P<0.001) and MVD (lower stress myocardial blood flow and myocardial perfusion reserve; both P<0.001). Patients with G-LVH+ were similar to those with G+LVH+ but had elevated second eigenvector angle (P<0.001 after adjustment for left ventricular hypertrophy and fibrosis). In overt disease, perfusion defects were found in all G+ but not all G- patients (100% [51/51] versus 82% [41/50]; P=0.001). Patients with G+LVH- compared with healthy volunteers similarly had altered microstructure, although to a lesser extent (all diffusion tensor imaging parameters; P<0.001), and MVD (reduced stress myocardial blood flow [P=0.015] with perfusion defects in 28% versus 0 healthy volunteers [P=0.002]). Disarray and MVD were independently associated with pathological electrocardiographic abnormalities in both overt and subclinical disease after adjustment for fibrosis and left ventricular hypertrophy (overt: fractional anisotropy: odds ratio for an abnormal ECG, 3.3, P=0.01; stress myocardial blood flow: odds ratio, 2.8, P=0.015; subclinical: fractional anisotropy odds ratio, 4.0, P=0.001; myocardial perfusion reserve odds ratio, 2.2, P=0.049). CONCLUSIONS: Microstructural alteration and MVD occur in overt HCM and are different in G+ and G- patients. Both also occur in the absence of hypertrophy in sarcomeric mutation carriers, in whom changes are associated with electrocardiographic abnormalities. Measurable changes in myocardial microstructure and microvascular function are early-phenotype biomarkers in the emerging era of disease-modifying therapy.


Assuntos
Cardiomiopatia Hipertrófica , Hipertrofia Ventricular Esquerda , Humanos , Sarcômeros/genética , Imagem de Tensor de Difusão , Predisposição Genética para Doença , Mutação , Cardiomiopatia Hipertrófica/diagnóstico , Fenótipo , Biomarcadores , Fibrose
2.
Circulation ; 146(25): 1930-1945, 2022 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-36417924

RESUMO

BACKGROUND: Autoimmunity is increasingly recognized as a key contributing factor in heart muscle diseases. The functional features of cardiac autoimmunity in humans remain undefined because of the challenge of studying immune responses in situ. We previously described a subset of c-mesenchymal epithelial transition factor (c-Met)-expressing (c-Met+) memory T lymphocytes that preferentially migrate to cardiac tissue in mice and humans. METHODS: In-depth phenotyping of peripheral blood T cells, including c-Met+ T cells, was undertaken in groups of patients with inflammatory and noninflammatory cardiomyopathies, patients with noncardiac autoimmunity, and healthy controls. Validation studies were carried out using human cardiac tissue and in an experimental model of cardiac inflammation. RESULTS: We show that c-Met+ T cells are selectively increased in the circulation and in the myocardium of patients with inflammatory cardiomyopathies. The phenotype and function of c-Met+ T cells are distinct from those of c-Met-negative (c-Met-) T cells, including preferential proliferation to cardiac myosin and coproduction of multiple cytokines (interleukin-4, interleukin-17, and interleukin-22). Furthermore, circulating c-Met+ T cell subpopulations in different heart muscle diseases identify distinct and overlapping mechanisms of heart inflammation. In experimental autoimmune myocarditis, elevations in autoantigen-specific c-Met+ T cells in peripheral blood mark the loss of immune tolerance to the heart. Disease development can be halted by pharmacologic c-Met inhibition, indicating a causative role for c-Met+ T cells. CONCLUSIONS: Our study demonstrates that the detection of circulating c-Met+ T cells may have use in the diagnosis and monitoring of adaptive cardiac inflammation and definition of new targets for therapeutic intervention when cardiac autoimmunity causes or contributes to progressive cardiac injury.


Assuntos
Doenças Autoimunes , Cardiomiopatias , Miocardite , Humanos , Camundongos , Animais , Autoimunidade , Células T de Memória , Miocardite/etiologia , Miocárdio , Cardiomiopatias/complicações , Miosinas Cardíacas , Inflamação/complicações
3.
J Intern Med ; 293(1): 23-47, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36030368

RESUMO

Dilated cardiomyopathy (DCM) is typically defined by left ventricular dilation and systolic dysfunction in the absence of a clear precipitant. Idiopathic disease is common; up to 50% of patients with DCM have no cause found despite imaging, genetic and biopsy assessments. Treatment remains focused on managing symptoms, reducing the risk of sudden cardiac death and ameliorating the structural and electrical complications of disease progression. In the absence of aetiology-specific treatments, the condition remains associated with a poor prognosis; mortality is approximately 40% at 10 years. The role of immune-mediated inflammatory injury in the development and progression of DCM was first proposed over 30 years ago. Despite the subsequent failures of three large clinical trials of immunosuppressive treatment (ATTACH, RENEWAL and the Myocarditis Treatment Trial), evidence for an abnormal adaptive immune response in DCM remains significant. In this review, we summarise and discuss available evidence supporting immune dysfunction in DCM, with a specific focus on cellular immunity. We also highlight current clinical and experimental treatments. We propose that the success of future immunosuppressive treatment trials in DCM will be dependent on the deep immunophenotyping of patients, to identify those with active inflammation and/or an abnormal immune response who are most likely to respond to therapy.


Assuntos
Cardiomiopatia Dilatada , Miocardite , Humanos , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/etiologia , Cardiomiopatia Dilatada/terapia , Miocardite/complicações , Miocardite/diagnóstico , Coração , Arritmias Cardíacas , Inflamação/complicações
4.
Phys Chem Chem Phys ; 25(27): 17999-18010, 2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37377153

RESUMO

In the present work, we synthesized the perovskite Ba0.70Er0.16Ca0.05Ti0.91Sn0.09O3 compound (BECTSO) by a solid-state reaction and sintering at 1200 °C. The effects of doping on the structural, electrical, dielectric, and ferroelectric characteristics of the material are examined in this work. X-ray powder diffraction analysis shows that BECTSO crystallizes in a tetragonal structure with space group P4mm. A detailed study of the dielectric relaxation of the BECTSO compound has been reported for the first time. Classical low-frequency ferroelectric and high-frequency relaxor ferroelectric behaviors have been studied. The study of the real part of the permittivity (ε') as a function of temperature demonstrated a high dielectric constant and identified a phase transition from the ferroelectric phase to the paraelectric phase at Tc = 360 K. The analysis of conductivity curves shows two behaviors: semiconductor behavior for f < 106 Hz and metallic behavior for f >106 Hz. The relaxation phenomenon is dominated by the short-range motion of the charge carriers. The BECTSO sample could be considered as a potential lead-free material for next-generation non-volatile memory devices and wide-temperature range capacitor applications.

5.
Can J Physiol Pharmacol ; 100(6): 509-520, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35395159

RESUMO

The present study hypothesized that cardiac metabolic inflexibility is dependent on cardiac atrial natriuretic peptide/brain natriuretic peptide (ANP/BNP) alteration and histone deacetylase (HDAC) activity. We further sought to investigate the therapeutic potential of short-chain amino acid (SCFA) acetate in high-fat diet (HFD)-induced obese rat model. Adult male Wistar rats were assigned into groups (n = 6 per group): Control, Obese, and Sodium acetate (NaAc)-treated and Obese + NaAc-treated groups received distilled water once daily (oral gavage), 40% HFD ad libitum, 200 mg/kg NaAc once daily (oral gavage), and 40% HFD + NaAc, respectively. The treatments lasted for 12 weeks. HFD resulted in increased food intake, body weight, and cardiac mass. It also caused insulin resistance and enhanced ß-cell function, increased fasting insulin, lactate, plasma and cardiac triglyceride, total cholesterol, lipid peroxidation, tumor necrosis factor-α, interleukin-6, HDAC, and cardiac troponin T and γ-glutamyl transferase, and decreased plasma and cardiac glutathione with unaltered cardiac ANP and BNP. However, these alterations were averted when treated with acetate. Taken together, these results indicate that obesity induces defective cardiac metabolic flexibility, which is accompanied by an elevated level of HDAC and not ANP/BNP alteration. The results also suggest that acetate ameliorates obesity-induced cardiac metabolic inflexibility by suppression of HDAC and independent of ANP/BNP modulation.


Assuntos
Fator Natriurético Atrial , Peptídeo Natriurético Encefálico , Acetatos/farmacologia , Animais , Dieta Hiperlipídica/efeitos adversos , Masculino , Obesidade/complicações , Obesidade/tratamento farmacológico , Ratos , Ratos Wistar
6.
Europace ; 23(9): 1409-1417, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-33930121

RESUMO

AIMS: Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). Data on the efficacy of catheter ablation of AF in HCM patients are sparse. METHODS AND RESULTS: Observational multicentre study in 137 HCM patients (mean age 55.0 ± 13.4, 29.1% female; 225 ablation procedures). We investigated (i) the efficacy of catheter ablation for AF beyond the initial 12 months; (ii) the available risk scores, stratification schemes and genotype as potential predictors of arrhythmia relapse, and (iii) the impact of cryoballoon vs. radiofrequency in procedural outcomes. Mean follow-up was 43.8 ± 37.0 months. Recurrences after the initial 12-month period post-ablation were frequent, and 24 months after the index procedure, nearly all patients with persistent AF had relapsed, and only 40% of those with paroxysmal AF remained free from arrhythmia recurrence. The APPLE score demonstrated a modest discriminative capacity for AF relapse post-ablation (c-statistic 0.63, 95% CI 0.52-0.75; P = 0.022), while the risk stratification schemes for sudden death did not. On multivariable analysis, left atrium diameter and LV apical aneurysm were independent predictors of recurrence. Fifty-eight patients were genotyped; arrhythmia-free survival was similar among subjects with different gene mutations. Rate of procedural complications was high (9.3%), although reducing over time. Outcome for cryoballoon and radiofrequency ablation was comparable. CONCLUSION: Very late AF relapses post-ablation is common in HCM patients, especially in those with persistent AF. Left atrium size, LV apical aneurysm, and the APPLE score might contribute to identify subjects at higher risk of arrhythmia recurrence. First-time cryoballoon is comparable with radiofrequency ablation.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Ablação por Cateter , Criocirurgia , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 31(10): 2626-2631, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32639666

RESUMO

INTRODUCTION: Patients with hypertrophic cardiomyopathy (HCM) and atrial fibrillation (AF) require chronic anticoagulation due to high thromboembolic risk. Evidence supporting the use of non-vitamin K oral anticoagulants (NOACs) in patients with HCM remains sparse, and there are no data regarding the use of NOACs in patients with HCM undergoing catheter ablation of AF. METHODS: Observational nonrandomized study in four European centers. We aimed to investigate the safety and efficacy of NOACs compared with vitamin K antagonists (VKAs) in patients with HCM undergoing catheter ablation for AF. RESULTS: A total of 137 patients with HCM (mean age: 55.0 ± 13.4, 29.1% female) underwent 230 catheter ablations for AF (1.7 ± 1.0 per patient). A total of 55 patients (39.4%) underwent 70 procedures (30.4%) on NOAC, while the remaining were on VKA. Warfarin (97.6%) and rivaroxaban (56.4%) were the most frequently used agents in the respective groups. No procedure-related deaths were reported. We observed no significant difference in the rate of thromboembolism (VKA: 0.6%; NOAC: 0%; p = 1.0) or minor bleeding (VKA: 0.6%; NOAC: 1.4%; p = .54). There was a nonsignificant trend towards a lower incidence of major bleeding (VKA: 6.9%; NOAC: 1.4%; p = .09). CONCLUSION: These preliminary data suggest that NOACs are at least as safe and effective as VKAs in patients with HCM undergoing catheter ablation for AF.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Ablação por Cateter , Acidente Vascular Cerebral , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Vitamina K
8.
Helminthologia ; 57(4): 306-313, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33364899

RESUMO

Protostrongylids, small nematode lungworms, are an integral part of the wild ruminant helminth community, which can damage animals' health when they are held in captivity or semi-captive conditions. The Sahelo-Saharan antelope species dorcas gazelle (Gazella dorcas), the scimitar-horned oryx (Oryx dammah), and the addax (Addax nasomacculatus), reintroduced to Souss-Massa National Park in Morocco, could be host to many species of Protostrongylids. This study was conducted from January to July 2015 to identify infecting parasite species, and determine their prevalence and abundance in all three antelope species. A total of 180 individual fecal samples were collected, morphologically examined by the Baermann technique, and molecularly identified by PCR amplification and sequencing of the second internal transcribed spacer region of the rDNA (ITS-2). Two parasite species were found in the three antelope populations: Muellerius capillaris and Neostrongylus linearis. The prevalence scores recorded for M. capillaris were 98.40 % in the addax, 96.70 % in dorcas gazelle, and 28.40 % in the oryx. The prevalence rates of N. linearis were 60 % in the addax, 23.40 % in dorcas gazelle, and 90 % in the oryx. Excreted larvae were quantified by LPG (larvae per gram) counting: for M. capillaris, the LPG mean values were 92.94 in the addax, 133.09 in dorcas gazelle, and 1.48 in the oryx; and for N. linearis, the LPG mean values were 6.02 in the addax, 1.37 in dorcas gazelle, and 32.81 in the oryx. These findings indicate that the three species of antelopes are infected with Muellerius capillaris and Neostrongylus linearis to varying degrees in intensity and prevalence.

9.
Circulation ; 137(10): 1015-1023, 2018 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-29191938

RESUMO

BACKGROUND: Identification of people with hypertrophic cardiomyopathy (HCM) who are at risk of sudden cardiac death (SCD) and require a prophylactic implantable cardioverter defibrillator is challenging. In 2014, the European Society of Cardiology proposed a new risk stratification method based on a risk prediction model (HCM Risk-SCD) that estimates the 5-year risk of SCD. The aim was to externally validate the 2014 European Society of Cardiology recommendations in a geographically diverse cohort of patients recruited from the United States, Europe, the Middle East, and Asia. METHODS: This was an observational, retrospective, longitudinal cohort study. RESULTS: The cohort consisted of 3703 patients. Seventy three (2%) patients reached the SCD end point within 5 years of follow-up (5-year incidence, 2.4% [95% confidence interval {CI}, 1.9-3.0]). The validation study revealed a calibration slope of 1.02 (95% CI, 0.93-1.12), C-index of 0.70 (95% CI, 0.68-0.72), and D-statistic of 1.17 (95% CI, 1.05-1.29). In a complete case analysis (n= 2147; 44 SCD end points at 5 years), patients with a predicted 5-year risk of <4% (n=1524; 71%) had an observed 5-year SCD incidence of 1.4% (95% CI, 0.8-2.2); patients with a predicted risk of ≥6% (n=297; 14%) had an observed SCD incidence of 8.9% (95% CI, 5.96-13.1) at 5 years. For every 13 (297/23) implantable cardioverter defibrillator implantations in patients with an estimated 5-year SCD risk ≥6%, 1 patient can potentially be saved from SCD. CONCLUSIONS: This study confirms that the HCM Risk-SCD model provides accurate prognostic information that can be used to target implantable cardioverter defibrillator therapy in patients at the highest risk of SCD.


Assuntos
Cardiologia , Cardiomiopatia Hipertrófica/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Estudos de Coortes , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/estatística & dados numéricos , Europa (Continente)/epidemiologia , Seguimentos , Humanos , Incidência , Guias de Prática Clínica como Assunto , Prognóstico , Projetos de Pesquisa , Estudos Retrospectivos , Risco , Sociedades Médicas
11.
Catheter Cardiovasc Interv ; 91(4): 783-789, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28766836

RESUMO

OBJECTIVES: To evaluate utility of Doppler echocardiography in the assessment of left ventricular (LV) mid-cavity obstructive (LVMCO) hypertrophic cardiomyopathy (HCM). BACKGROUND: LVMCO is a relatively under-diagnosed complication of HCM and may occur alone or in combination with LV outflow tract obstruction (LVOTO). Identifying and quantifying LVMCO and differentiating it from LVOTO has important implications for patient management. We aimed to assess diagnostic performance of Doppler echocardiography in the assessment of suspected LV obstruction. METHODS: Forty symptomatic HCM patients with suspected obstruction underwent cardiac catheterization, and comparison of location and magnitude of Doppler derived gradients with synchronous invasive measurements (reference standard), at rest and isoprenaline stress (IS). RESULTS: Doppler's diagnostic accuracy for any obstruction (≥30 mmHg) in this cohort was 75% with false positive and false negative rates of 2.5 and 22.5%, respectively. During subanalysis, Doppler's diagnostic accuracy for isolated LVOTO in this selected cohort is 83% with false positive and false negative rates of 4 and 12.5%, respectively. For LVMCO, the accuracy is only 50%, with false positive and false negative rates of 10 and 40%, respectively. Doppler gradients for isolated LVOTO were similar to invasive: 85 ± 51 and 87 ± 35 mmHg, respectively (P = 0.77). Doppler gradients in LVMCO were consistently lower than invasive: 45 ± 38 and 81 ± 31 mmHg, respectively (P = 0.0002). Mid-systolic flow cessation and/or contamination of spectral signals were identified as causes of Doppler-derived inaccuracies. CONCLUSIONS: Doppler echocardiography under-diagnoses and underestimates severity of LVMCO in symptomatic HCM patients. Recognition of abrupt mid-systolic flow cessation and invasive measurements may improve detection of LVMCO in HCM.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Ecocardiografia sob Estresse/métodos , Função Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Agonistas Adrenérgicos beta/administração & dosagem , Adulto , Idoso , Cateterismo Cardíaco , Cardiomiopatia Hipertrófica/epidemiologia , Cardiomiopatia Hipertrófica/fisiopatologia , Estudos Transversais , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Isoproterenol/administração & dosagem , Londres/epidemiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Obstrução do Fluxo Ventricular Externo/epidemiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia
12.
Eur Heart J ; 37(32): 2552-9, 2016 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-26188002

RESUMO

AIMS: To provide insight into the mechanism of sudden adult death syndrome (SADS) and to give new clinical guidelines for the cardiac management of patients with the most common mitochondrial DNA mutation, m.3243A>G. These studies were initiated after two young, asymptomatic adults harbouring the m.3243A>G mutation died suddenly and unexpectedly. The m.3243A>G mutation is present in ∼1 in 400 of the population, although the recognized incidence of mitochondrial DNA (mtDNA) disease is ∼1 in 5000. METHODS AND RESULTS: Pathological studies including histochemistry and molecular genetic analyses performed on various post-mortem samples including cardiac tissues (atrium and ventricles) showed marked respiratory chain deficiency and high levels of the m.3243A>G mutation. Systematic review of cause of death in our m.3243A>G patient cohort showed the person-time incidence rate of sudden adult death is 2.4 per 1000 person-years. A further six cases of sudden death among extended family members have been identified from interrogation of family pedigrees. CONCLUSION: Our findings suggest that SADS is an important cause of death in patients with m.3243A>G and likely to be due to widespread respiratory chain deficiency in cardiac muscle. The involvement of asymptomatic relatives highlights the importance of family tracing in patients with m.3243A>G and the need for specific cardiac arrhythmia surveillance in the management of this common genetic disease. In addition, these findings have prompted the derivation of cardiac guidelines specific to patients with m.3243A>G-related mitochondrial disease. Finally, due to the prevalence of this mtDNA point mutation, we recommend inclusion of testing for m.3243A>G mutations in the genetic autopsy of all unexplained cases of SADS.


Assuntos
Morte Súbita , Adulto , DNA Mitocondrial , Humanos , Mitocôndrias , Doenças Mitocondriais , Mutação
13.
Acta Virol ; 59(2): 174-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26104334

RESUMO

Here we identified four isolates, MS, 3H, 50A, and 2K of cucumber mosaic virus (CMV) infecting tomato, on the basis of their non-coding intergenic region and a part of the coat protein (CP) sequence in the CMV genomic RNA3. The sequences from the four isolates were compared with other previously characterized isolates of CMV isolated from different plant species across the globe. Sequence comparisons revealed that the two CMV isolates from Hamedan province (MS and 3H) had the highest sequence identity with CMV-G10 (98%), which was previously reported as a severe Hellenic tomato isolate of CMV, while the CMV isolates from Tehran province, including CMV-2K (isolated from Karaj region) and CMV-50A (isolated from Varamin region), had the highest sequence identity with that of CMV-ALF (99%). Phylogenetic analysis of the nucleotide sequences showed that CMV-MS and CMV-3H belong to group IB, while CMV-2K and CMV-50A belong to group IA. This is the first report on the molecular characterization of novel isolates of CMV infecting tomato plants in Iran.


Assuntos
Cucumovirus/genética , Cucumovirus/isolamento & purificação , Doenças das Plantas/virologia , Solanum lycopersicum/virologia , Cucumovirus/classificação , Irã (Geográfico) , Dados de Sequência Molecular , Filogenia , Proteínas Virais/genética
14.
Turk Kardiyol Dern Ars ; 43(3): 302-14, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25906005

RESUMO

Cardiomyopathies are myocardial disorders that are not explained by abnormal loading conditions and coronary artery disease. They are classified into a number of morphological and functional phenotypes that can be caused by genetic and non-genetic mechanisms. The dominant themes in papers published in 2012-2013 are similar to those reported in Almanac 2011, namely, the use (and interpretation) of genetic testing, development and application of novel non-invasive imaging techniques and use of serum biomarkers for diagnosis and prognosis. An important innovation since the last Almanac is the development of more sophisticated models for predicting adverse clinical events.


Assuntos
Cardiomiopatias/diagnóstico , Cardiomiopatias/terapia , Humanos
15.
J Dairy Sci ; 97(12): 7505-14, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25282408

RESUMO

With the aim of assessing the secondary benefits of using electronic identification (e-ID) in sheep farms, we compared the use of manual (M), semiautomatic (SA), and automatic (AU) data-collection systems for performance recording (i.e., milk, lambing, and weight) in 3 experiments. Ewes were identified with visual ear tags and electronic rumen boluses. The M system consisted of visual ear tags, on-paper data recording, and manual data uploading to a computer; the use of a personal digital assistant (PDA) for data recording and data uploading was also done in M. The SA system used a handheld reader (HHR) for e-ID, data recording, and uploading. Both PDA and HHR used Bluetooth for uploading. The AU system was only used for body weight recording and consisted of e-ID, data recording in an electronic scale, and data uploading. In experiment 1, M and SA milk-recording systems were compared in a flock of 48 dairy ewes. Ewes were milked once- (×1, n=24) or twice- (×2, n=24) daily in a 2 × 12 milking parlor and processed in groups of 24. Milk yield (1.21 ± 0.04 L/d, on average) was 36% lower in ×1 than ×2 ewes and milk recording time correlated positively with milk yield (R(2)=0.71). Data transfer was markedly faster for PDA and HHR than for M. As a result, overall milk recording time was faster in SA (×1=12.1 ± 0.6 min/24 ewes; ×2=22.1 ± 0.9 min/24 ewes) than M (×1=14.9 ± 0.6 min/24 ewes; ×2=27.9 ± 1.0 min/24 ewes). No differences between PDA and HHR were detected. Time savings, with regard to M, were greater for ×2 than for ×1 (5.6 ± 0.2 vs. 2.8 ± 0.1 min per 24 ewes, respectively), but similar for PDA and HHR. Data transfer errors averaged 3.6% in M, whereas no errors were found in either SA system. In experiment 2, 73 dairy and 80 meat ewes were monitored at lambing using M and SA. Overall time for lambing recording was greater in M than SA in dairy (1.67 ± 0.06 vs. 0.87 ± 0.04 min/ewe) and meat (1.30 ± 0.03 vs. 0.73 ± 0.03 min/ewe) ewes. Recording errors were greater in dairy (9.6%) than in meat (1.9%) ewes. Data uploading errors only occurred in M (4.9%). In experiment 3, 120 dairy and 120 meat ewes were weighed using M and AU systems. In both flocks, mean BW recording and data uploading times, as well as overall BW recording time (0.63 ± 0.02 and 0.25 ± 0.01 min/ewe, respectively) were greater in M than in AU, and uploading errors only occurred in M (8.8%). In conclusion, HHR and PDA systems were time-effective for performance recording, both saving time and improving data accuracy. Working load and time for ewe identification were faster in HHR but it did not affect the performance recording time. The PDA was the fastest device for data download. Further research will evaluate the costs of implementing e-ID for performance recording and other uses in sheep farms.


Assuntos
Sistemas de Identificação Animal/veterinária , Indústria de Laticínios/métodos , Coleta de Dados/métodos , Carne , Leite/metabolismo , Ovinos/fisiologia , Animais , Peso Corporal , Indústria de Laticínios/instrumentação , Eletrônica/instrumentação , Feminino , Rúmen , Fatores de Tempo
16.
J Dairy Sci ; 97(12): 7515-24, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25282418

RESUMO

Costs and secondary benefits of implementing electronic identification (e-ID) for performance recording (i.e., lambing, body weight, inventory, and milk yield) in dairy and meat ewes were assessed by using the results from a previous study in which manual (M), semiautomatic (SA), and automatic (AU) data collection systems were compared. Ewes were identified with visual ear tags and electronic rumen boluses. The M system used visual identification, on-paper data recording, and manual data uploading to a computer. The SA system used e-ID with a handheld reader in which performances were typed and automatic uploaded to a computer. The use of a personal digital assistant (PDA) for recording and automatic data uploading, which transformed M in a SA system, was also considered. The AU system was only used for BW recording and consisted of e-ID, automatic data recording in an electronic scale, and uploading to a computer. The cost-benefit study was applied to 2 reference sheep farms of 700 meat ewes, under extensive or intensive production systems, and of 400 dairy ewes, practicing once- or twice-a-day machine milkings. Sensitivity analyses under voluntary and mandatory e-ID scenarios were also included. Benefits of using e-ID for SA or AU performance recording mainly depended on sheep farm purpose, number of test days per year, handheld reader and PDA prices, and flock size. Implementing e-ID for SA and AU performance recording saved approximately 50% of the time required by the M system, and increased the reliability of the data collected. Use of e-ID increased the cost of performance recording in a voluntary e-ID scenario, paying only partially the investment made (15 to 70%). For the mandatory e-ID scenario, in which the cost of e-ID devices was not included, savings paid 100% of the extra costs needed for using e-ID in all farm types and conditions. In both scenarios, the reader price was the most important extra cost (40 to 90%) for implementing e-ID in sheep farms. Calculated extra costs of using the PDA covered more than 100% of the implementation costs in all type of sheep farms, indicating that this device was cost-effective for sheep-performance recording.


Assuntos
Sistemas de Identificação Animal/veterinária , Indústria de Laticínios/métodos , Carne/economia , Leite/economia , Ovinos/fisiologia , Agricultura/economia , Sistemas de Identificação Animal/economia , Sistemas de Identificação Animal/métodos , Animais , Peso Corporal , Computadores de Mão/economia , Análise Custo-Benefício , Indústria de Laticínios/economia , Eletrônica/instrumentação , Feminino , Leite/metabolismo , Reprodutibilidade dos Testes , Rúmen
17.
Front Cardiovasc Med ; 11: 1408574, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39314764

RESUMO

Myocarditis is a cardiovascular disease characterised by inflammation of the heart muscle which can lead to heart failure. There is heterogeneity in the mode of presentation, underlying aetiologies, and clinical outcome with impact on a wide range of age groups which lead to diagnostic challenges. Cardiovascular magnetic resonance (CMR) is the preferred imaging modality in the diagnostic work-up of those with acute myocarditis. There is a need for systematic analytical approaches to improve diagnosis. Artificial intelligence (AI) and machine learning (ML) are increasingly used in CMR and has been shown to match human diagnostic performance in multiple disease categories. In this review article, we will describe the role of CMR in the diagnosis of acute myocarditis followed by a literature review on the applications of AI and ML to diagnose acute myocarditis. Only a few papers were identified with limitations in cases and control size and a lack of detail regarding cohort characteristics in addition to the absence of relevant cardiovascular disease controls. Furthermore, often CMR datasets did not include contemporary tissue characterisation parameters such as T1 and T2 mapping techniques, which are central to the diagnosis of acute myocarditis. Future work may include the use of explainability tools to enhance our confidence and understanding of the machine learning models with large, better characterised cohorts and clinical context improving the diagnosis of acute myocarditis.

18.
Artigo em Inglês | MEDLINE | ID: mdl-39179417

RESUMO

The management of acute myocarditis (AM) is addressed in multiple clinical guidelines. We systematically reviewed current guidelines developed by national and international medical organizations on the management of AM to aid clinical practice. Publications in MEDLINE, EMBASE and Cochrane were identified between 1 January 2013 and 12 April 2024. Additionally, the websites of relevant organizations and the Guidelines International Network, Guideline Central, and NHS knowledge and library hub were reviewed. Two reviewers independently screened titles and abstracts, two reviewers assessed the rigour of guideline development, and one reviewer extracted the recommendations. Two of the three guidelines identified showed good rigour of development. Those rigorously developed agreed on the definition of AM, sampling serum troponin as part of the workflow for AM, testing for B-type natriuretic peptides in heart failure, key diagnostic imaging in the form of cardiovascular magnetic resonance, coronary angiography to exclude significant coronary disease, indications for endomyocardial biopsy (EMB), and indications for immunosuppression and advanced treatment options. Discrepancies exist in sampling creatine kinase-myocardial bound as a marker of myocardial injury, indications for EMB, and indications for immunosuppression and treatment of uncomplicated AM. Evidence is lacking for the use of 18F-Fluorodeoxyglucose Positron Emission Tomography for myocardial imaging, exercise restriction, follow-up measures and genetic testing, and there are few high-quality randomized trials to support treatment recommendations. Recommendations for management of AM in the guidelines have largely been developed from expert opinion rather than trial data.

19.
Circ Arrhythm Electrophysiol ; 17(7): e012570, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39012930

RESUMO

BACKGROUND: Patients with refractory, symptomatic left ventricular (LV) mid-cavity obstructive (LVMCO) hypertrophic cardiomyopathy have few therapeutic options. Right ventricular pacing is associated with modest hemodynamic and symptomatic improvement, and LV pacing pilot data suggest therapeutic potential. We hypothesized that site-specific pacing would reduce LVMCO gradients and improve symptoms. METHODS: Patients with symptomatic-drug-refractory LVMCO were recruited for a randomized, blinded trial of personalized prescription of pacing (PPoP). Multiple LV and apical right ventricular pacing sites were assessed during an invasive hemodynamic study of multisite pacing. Patient-specific pacing-site and atrioventricular delays, defining PPoP, were selected on the basis of LVMCO gradient reduction and acceptable pacing parameters. Patients were randomized to 6 months of active PPoP or backup pacing in a crossover design. The primary outcome examined invasive gradient change with best-site pacing. Secondary outcomes assessed quality of life and exercise following randomization to PPoP. RESULTS: A total of 17 patients were recruited; 16 of whom met primary end points. Baseline New York Heart Association was 3±0.6, despite optimal medical therapy. Hemodynamic effects were assessed during pacing at the right ventricular apex and at a mean of 8 LV sites. The gradients in all 16 patients fell with pacing, with maximum gradient reduction achieved via LV pacing in 14 (88%) patients and right ventricular apex in 2. The mean baseline gradient of 80±29 mm Hg fell to 31±21 mm Hg with best-site pacing, a 60% reduction (P<0.0001). One cardiac vein perforation occurred in 1 case, and 15 subjects entered crossover; 2 withdrawals occurred during crossover. Of the 13 completing crossover, 9 (69%) chose active pacing in PPoP configuration as preferred setting. PPoP was associated with improved 6-minute walking test performance (328.5±99.9 versus 285.8±105.5 m; P=0.018); other outcome measures also indicated benefit with PPoP. CONCLUSIONS: In a randomized placebo-controlled trial, PPoP reduces obstruction and improves exercise performance in severely symptomatic patients with LVMCO. REGISTRATION: URL: https://clinicaltrials.gov/study; Unique Identifier: NCT03450252.


Assuntos
Estimulação Cardíaca Artificial , Cardiomiopatia Hipertrófica , Estudos Cross-Over , Função Ventricular Esquerda , Humanos , Masculino , Feminino , Estimulação Cardíaca Artificial/métodos , Pessoa de Meia-Idade , Cardiomiopatia Hipertrófica/terapia , Cardiomiopatia Hipertrófica/fisiopatologia , Cardiomiopatia Hipertrófica/diagnóstico , Resultado do Tratamento , Idoso , Qualidade de Vida , Fatores de Tempo , Hemodinâmica , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/terapia , Obstrução do Fluxo Ventricular Externo/diagnóstico , Tolerância ao Exercício , Função Ventricular Direita , Recuperação de Função Fisiológica
20.
Front Physiol ; 15: 1428709, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39206383

RESUMO

Introduction: Patients with hypertrophic cardiomyopathy (HCM) are at risk for lethal ventricular arrhythmia, but the electrophysiological substrate behind this is not well-understood. We used non-invasive electrocardiographic imaging to characterize patients with HCM, including cardiac arrest survivors. Methods: HCM patients surviving ventricular fibrillation or hemodynamically unstable ventricular tachycardia (n = 17) were compared to HCM patients without a personal history of potentially lethal arrhythmia (n = 20) and a pooled control group with structurally normal hearts. Subjects underwent exercise testing by non-invasive electrocardiographic imaging to estimate epicardial electrophysiology. Results: Visual inspection of reconstructed epicardial HCM maps revealed isolated patches of late activation time (AT), prolonged activation-recovery intervals (ARIs), as well as reversal of apico-basal trends in T-wave inversion and ARI compared to controls (p < 0.005 for all). AT and ARI were compared between groups. The pooled HCM group had longer mean AT (60.1 ms vs. 52.2 ms, p < 0.001), activation dispersion (55.2 ms vs. 48.6 ms, p = 0.026), and mean ARI (227 ms vs. 217 ms, p = 0.016) than structurally normal heart controls. HCM ventricular arrhythmia survivors could be differentiated from HCM patients without a personal history of life-threatening arrhythmia by longer mean AT (63.2 ms vs. 57.4 ms, p = 0.007), steeper activation gradients (0.45 ms/mm vs. 0.36 ms/mm, p = 0.011), and longer mean ARI (234.0 ms vs. 221.4 ms, p = 0.026). A logistic regression model including whole heart mean activation time and activation recovery interval could identify ventricular arrhythmia survivors from the HCM cohort, producing a C statistic of 0.76 (95% confidence interval 0.72-0.81), with an optimal sensitivity of 78.6% and a specificity of 79.8%. Discussion: The HCM epicardial electrotype is characterized by delayed, dispersed conduction and prolonged, dispersed activation-recovery intervals. Combination of electrophysiologic measures with logistic regression can improve differentiation over single variables. Future studies could test such models prospectively for risk stratification of sudden death due to HCM.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA