Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Cureus ; 16(2): e53540, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38318279

RESUMO

Introduction Distal tibiofibular joint (DTFJ) injuries are commonly encountered in patients with ankle fractures. Achieving optimal fixation is mandatory, but it requires a thorough understanding of the local anatomical relationships. For this reason, we performed a retrospective CT study in healthy ankles to radiologically describe the normal anatomy of the DTFJ and the anatomical relationship of the fibula within the ankle joint. Materials and methods For this study, we retrospectively examined 60 CT scans of healthy, non-injured ankles in a plantigrade position. Patients with prior ankle surgery or systemic diseases with ankle involvement were excluded because we needed to describe the normal anatomy of the joint. The radiological evaluation included the position of the fibula in the fibular notch and the rotational relationship of the fibula with the talus and the medial malleolus. Results Our study included 60 healthy ankles. Thirty-three were right ankles, and 27 were left. The cohort included 36 females and 24 males with a mean age of 48.3 years old. We found that the fibular notch was retroverted on the transverse plane, with the tibiofibular engagement being 0.11 mm (SD=1.57 mm, SE=0.2 mm), at 1 cm proximally to the tibial plafond. Additionally, we observed that the fibula was internally rotated against the lateral talar facet, while the medial and lateral malleolus facets were externally rotated in between. Moreover, we found a strong positive correlation between the incisura retroversion and fibular engagement at 1 cm above the tibial plafond line (Pearson correlation=0.273, p=0.03). Conclusion Our study highlights the importance of gaining a comprehensive understanding of the inherent anatomy of the DTFJ to achieve reduction goals in ankle fractures. According to our results, in ankle fracture treatment, surgeons should aim for anatomical fracture and syndesmotic fixation, with the fibula in internal rotation against the lateral talar facet. Additionally, as normal tibiofibular engagement is borderline, we do not suggest that over-tightening the syndesmotic screws is essential. This study's findings can aid surgeons in reducing the malreduction rates in patients with ankle fractures.

2.
World J Methodol ; 14(1): 90930, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38577201

RESUMO

BACKGROUND: Selecting the optimal size of components is crucial when performing a primary total hip arthroplasty. Implanting the accurate size of the acetabular component can occasionally be exacting, chiefly for surgeons with little experience, whilst the complications of imprecise acetabular sizing or over-reaming can be potentially devastating. AIM: To assist clinicians intraoperatively with a simple and repeatable tip in elucidating the ambivalence when determining the proper acetabular component size is not straightforwardly achieved, specifically when surgeons are inexperienced or preoperative templating is unavailable. METHODS: This method was employed in 263 operations in our department from June 2021 to December 2022. All operations were performed by the same team of joint reconstruction surgeons, employing a typical posterior hip approach technique. The types of acetabular shells implanted were: The Dynasty® acetabular cup system (MicroPort Orthopedics, Shanghai, China) and the R3® acetabular system (Smith & Nephew, Watford, United Kingdom), which both feature cementless press-fit design. RESULTS: The mean value of all cases was calculated and collated with each other. We distinguished as oversized an implanted acetabular shell when its size was > 2 mm larger than the size of the acetabular size indicator reamer (ASIR) or when the implanted shell was larger than 4 mm compared to the preoperative planned cup. The median size of the implanted acetabular shell was 52 (48-54) mm, while the median size of the preoperatively planned cup was 50 (48-56) mm, and the median size of the ASIR was 52 (50-54) mm. The correlation coefficient between ASIR size and implanted acetabular component size exhibited a high positive correlation with r = 0.719 (P < 0.001). Contrariwise, intraoperative ASIR measurements precisely predicted the implanted cups' size or differed by only one size (2 mm) in 245 cases. CONCLUSION: In our study, we demonstrated that the size of the first acetabular reamer not entering freely in the acetabular rim corroborates the final acetabular component size to implant. This was also corresponding in the majority of the cases with conventional preoperative templating. It can be featured as a valid tool for avoiding the potentially pernicious complications of acetabular cup over-reaming and over-sizing in primary total hip arthroplasty. It is a simple and reproducible technical note useful for confirming the predicted acetabular cup size preoperatively; thus, its application could be considered routinely, even in cases where preoperative templating is unavailable.

3.
J Clin Med ; 13(12)2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38930119

RESUMO

Background: Spinal cord compression is a formidable complication of advanced cancer, and clinicians of copious specialities often have to encounter significant complex challenges in terms of diagnosis, management, and prognosis. Metastatic lesions from cancer are a common cause of spinal cord compression, affecting a substantial portion of oncology patients, and only in the US has the percentage risen to 10%. Acute metastasis-correlated spinal cord compression poses a considerable clinical challenge, necessitating timely diagnosis and intervention to prevent neurological deficits. Clinical presentation is often non-specific, emphasizing the importance of thorough evaluation and appropriate differential diagnosis. Diagnostic workup involves various imaging modalities and laboratory studies to confirm the diagnosis and assess the extent of compression. Treatment strategies focus on pain management and preserving spinal cord function without significantly increasing patient life expectancy, while multidisciplinary approaches are often required for optimal outcomes. Prognosis depends on several factors, highlighting the importance of early intervention. We provide an up-to-date overview of acute spinal cord compression in metastases, accentuating the importance of comprehensive management strategies. Objectives: This paper extensively explores the pathophysiology, clinical presentation, diagnostic strategies, treatment modalities, and prognosis associated with spinal cord metastases. Materials and Methods: A systematic literature review was conducted in accordance with the PRISMA guidelines. Conclusions: We aim to help healthcare professionals make informed clinical decisions when treating patients with spinal cord metastases by synthesizing current evidence and clinical insights.

4.
J Long Term Eff Med Implants ; 34(3): 37-41, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38505892

RESUMO

Persistent pain is one of the most frequent complications following total knee arthroplasty (TKA) and can be devastating for the patient's quality of life. The use of genicular nerve radiofrequency ablation (GNRFA) is prevalent regarding non-surgical treatment of knee osteoarthritis. However, it is controversial when employed for the management of residual pain after TKA. This study aims to evaluate the efficacy of GNRFA for the treatment of post-TKA chronic pain and to assess the potential benefits of its use. Twelve patients sustaining chronic pain after TKA underwent GNRFA treatment. The intervention included the superior medial genicular nerve, the superior lateral genicular nerve and the inferior medial genicular nerve. Visual analog scale (VAS) system was utilized for pain assessment at 1-week, 6-month, and 1-year follow-ups. Patients experiencing chronic knee pain derived from other or unspecified causes were excluded. Mean VAS score before the treatment was 8.3, while it ended up 2.3, 5.7, and 7.9 at the 1-week, 6-month, and 1-year follow-up, respectively. Some patients reported residual pain that they regarded more bearable than before the procedure at the 1-week evaluation, with no significant alterations in the 6-month reassessment. In 2 cases results at the 1-week follow-up were dissatisfying, however, this aided us in distinguishing the cause of the persistent pain. We were not able to conclude that GNRFA used for the treatment of chronic pain after TKA is as efficacious as in knee osteoarthritis pain. However, in some cases, it proved to be beneficial regarding discerning the etiology of the pain.


Assuntos
Artroplastia do Joelho , Dor Crônica , Osteoartrite do Joelho , Ablação por Radiofrequência , Humanos , Artroplastia do Joelho/efeitos adversos , Osteoartrite do Joelho/cirurgia , Dor Crônica/etiologia , Dor Crônica/cirurgia , Qualidade de Vida , Articulação do Joelho/cirurgia , Ablação por Radiofrequência/efeitos adversos , Resultado do Tratamento
5.
Biomedicines ; 12(5)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38790921

RESUMO

BACKGROUND: The global population, especially in the Western world, is constantly aging and the need for total hip arthroplasties has rocketed, hence there has been a notable increase in revision total hip arthroplasty cases. As time has passed, a considerable developments in science and medicine have been attained which have also resulted in the evolution of both surgical techniques and implants. Continuous improvements have allowed large bore bearings to be utilized which provide an increased range of motion, with ameliorated stability and a very low rate of wear. The trend for almost the last two decades has been the employment of porous tantalum acetabular cups. Several studies exist comparing them with other conventional methods for total hip arthroplasties, exhibiting promising short and midterm results. METHODS: The Preferred Reporting Items for Systematic Reviews and a Meta-Analysis (PRISMA) were used to identify published studies in a comprehensive search up to February 2023, and these studies were reviewed by the authors of the article. Specific rigorous pre-determined inclusion and exclusion criteria were implemented. RESULTS: Fifty-one studies met our inclusion criteria and were involved in the systematic review. Sixteen studies examined postoperative clinical and radiological outcomes of using a tantalum cup in primary and revision total hip arthroplasty, whilst four biomechanical studies proved the superiority of tantalum acetabular components. Five articles provided a thorough comparison between tantalum and titanium acetabular cups, while the other studies analyzed long-terms results and complication rates. CONCLUSIONS: Porous tantalum acetabular cups appear to be a valuable option in revision total hip arthroplasty, providing clinical improvement, radiological stability, and promising long-term outcomes. However, ongoing research, longer follow-up periods, and careful consideration of patient factors are essential to further validate and refine the use of tantalum in various clinical scenarios.

6.
Cureus ; 16(1): e53003, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38406115

RESUMO

Background Osteoporosis is globally recognized as a prevalent bone disease, and proximal femoral fractures constitute a serious complication associated with it. In recent years, the frequency of hip fractures has increased rapidly, with ramifications that extend into the social and economic aspects of both patients' lives and healthcare systems. The primary goal of this study is to discover whether bone mineral density (BMD) in specific regions of the hip could be related to femoral neck or trochanteric fractures. Methodology This prospective cohort study employed dual-energy X-ray absorptiometry (DEXA) measurements on 70 individuals with proximal femoral fractures. The participants sought treatment at the emergency department of our unit for hip fractures and adhered to our predefined eligibility criteria. These criteria primarily included (i) age exceeding 60 years and (ii) a diagnosis of either femoral neck or trochanteric fracture attributed to (iii) a low-energy lateral fall and (iv) a previously established state of complete ambulation before the occurrence of the fracture. In this context, we recorded the BMD of the hip, as well as the BMD values of the upper and lower halves of the neck, trochanteric region, and diaphysis. For the comparison of the categorical variables, Pearson's χ2 criterion was used, whereas Student's t-test was applied for the comparison of means of quantitative variables across fracture types. Results No statistical differences were identified when comparing regional BMDs and T-scores with the fracture type. This conclusion was also reconfirmed concerning age, gender, and Tonnis classification. Only a moderate correlation was observed, demonstrating lower values of regional BMDs in women compared to men. Conclusions The inability of our study to establish a direct correlation between BMD measurements across diverse areas of the proximal femur underlines the imperative need for subsequent investigations. These studies should not only integrate more precise techniques for measuring and mapping the BMD of different hip regions but should also encompass a comprehensive examination that would consider both intrinsic and extrinsic characteristics of the proximal femur.

7.
Diagnostics (Basel) ; 14(3)2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38337763

RESUMO

BACKGROUND: The COVID-19 pandemic has presented numerous challenges to the global healthcare system and emerging evidence suggests a potential link between COVID-19 treatment, specifically steroid therapy, and the development of avascular necrosis (AVN) of the hip. This review aims to provide a comprehensive overview of recent studies and case reports investigating the relationship between COVID-19, corticosteroid therapy, and the development of AVN. Understanding the nuances of AVN in the context of COVID-19 is crucial for healthcare professionals to navigate treatment decisions and mitigate potential complications. MATERIALS AND METHODS: The Preferred Reporting Items for Systematic Reviews and a Meta-Analysis (PRISMA) were used in the systematic review until 1 September 2023. The full texts of the remaining twenty-three (n = 23) articles were independently reviewed by the authors of this review. CONCLUSIONS: The association between steroid therapy for COVID-19 and the development of hip AVN is a noteworthy concern even though no relationship is evident between the duration of treatment, cumulative dosage of medication, maximum daily dosage received, and presence of AVN. Further research with larger cohorts and long-term follow up is needed to better understand the causative relationship and optimal management strategies for hip AVN in the context of COVID-19 and steroid therapy.

8.
World J Orthop ; 15(3): 247-256, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38596188

RESUMO

BACKGROUND: Computer-assisted systems obtained an increased interest in orthopaedic surgery over the last years, as they enhance precision compared to conventional hardware. The expansion of computer assistance is evolving with the employment of augmented reality. Yet, the accuracy of augmented reality navigation systems has not been determined. AIM: To examine the accuracy of component alignment and restoration of the affected limb's mechanical axis in primary total knee arthroplasty (TKA), utilizing an augmented reality navigation system and to assess whether such systems are conspicuously fruitful for an accomplished knee surgeon. METHODS: From May 2021 to December 2021, 30 patients, 25 women and five men, underwent a primary unilateral TKA. Revision cases were excluded. A preoperative radiographic procedure was performed to evaluate the limb's axial alignment. All patients were operated on by the same team, without a tourniquet, utilizing three distinct prostheses with the assistance of the Knee+™ augmented reality navigation system in every operation. Postoperatively, the same radiographic exam protocol was executed to evaluate the implants' position, orientation and coronal plane alignment. We recorded measurements in 3 stages regarding femoral varus and flexion, tibial varus and posterior slope. Firstly, the expected values from the Augmented Reality system were documented. Then we calculated the same values after each cut and finally, the same measurements were recorded radiologically after the operations. Concerning statistical analysis, Lin's concordance correlation coefficient was estimated, while Wilcoxon Signed Rank Test was performed when needed. RESULTS: A statistically significant difference was observed regarding mean expected values and radiographic measurements for femoral flexion measurements only (Z score = 2.67, P value = 0.01). Nonetheless, this difference was statistically significantly lower than 1 degree (Z score = -4.21, P value < 0.01). In terms of discrepancies in the calculations of expected values and controlled measurements, a statistically significant difference between tibial varus values was detected (Z score = -2.33, P value = 0.02), which was also statistically significantly lower than 1 degree (Z score = -4.99, P value < 0.01). CONCLUSION: The results indicate satisfactory postoperative coronal alignment without outliers across all three different implants utilized. Augmented reality navigation systems can bolster orthopaedic surgeons' accuracy in achieving precise axial alignment. However, further research is required to further evaluate their efficacy and potential.

9.
Healthcare (Basel) ; 12(2)2024 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-38275553

RESUMO

BACKGROUND: Total hip arthroplasty is indubitably a dominant elective surgery in orthopaedics, contributing to prodigious improvement in the quality of life of patients with osteoarthritis. One of the most potentially devastating complications of this operation is periprosthetic joint infection. Immunocompromised patients might be afflicted by infrequent low-virulence organisms not typically detected with conventional procedures. Consequently, employing advanced identification methods, such as the circumstantial sonication of orthopaedic implants, could be crucial to managing such cases. CASE PRESENTATION: We present a peculiar case of a 72-year-old female patient suffering from a chronic periprosthetic hip infection due to Corynebacterium striatum. The pathogen was only identified after rigorous sonication of the extracted implants. The overall management of this case was immensely exacting, primarily because of the patient's impaired immune system, and was finally treated with two-stage revision in our Institution. LITERATURE REVIEW: Although copious literature exists concerning managing periprosthetic hip infections, no concrete guidelines are available for such infections in multimorbid or immunocompromised patients with rare low-virulence microorganisms. Hence, a diagnostic work-up, antibiotic treatment and appropriate revision timeline must be determined. Sonication of extracted implants could be a powerful tool in the diagnostic arsenal, as it can aid in identifying rare microbes, such as Corynebacterium spp. Pertinent antibiotic treatment based on antibiogram analysis and apposite final revision-surgery timing are the pillars for effective therapy of such infections. CLINICAL RELEVANCE: Corynebacterium striatum has been increasingly recognized as an emerging cause of periprosthetic hip infection in the last decade. A conspicuous rise in such reports has been observed in multimorbid or immunocompromised patients after the COVID-19 pandemic. This case is the first report of Corynebacterium striatum periprosthetic hip infection diagnosed solely after the sonication of extracted implants. This paper aims to increase awareness surrounding Corynebacterium spp. prosthetic joint infections, while highlighting the fields for further apposite research.

10.
J Funct Morphol Kinesiol ; 9(2)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38651421

RESUMO

Total hip arthroplasty is indubitably one of the most performed operations worldwide. On the other hand, especially in the western world, the average age that women get pregnant has raised confoundedly. Consequently, a steadily increasing number of women become pregnant after they had hip arthroplasty surgery, with copious potential implications. The amount of knowledge on this particular field is considered inadequate in the existing literature. This paper aims to augment clinicians understanding surrounding this topic. A systematic literature review was conducted in accordance with the PRISMA guidelines. Papers from various computerized databases were scrutinized. Article selection was carried out by three authors independently employing specific pre-determined inclusion and exclusion criteria, while disagreements were elucidated with the contribution of other authors. A patently limited number of research articles were detected from our rigorous literature review, with only 12 papers meeting the inclusion criteria. The vast majority of studies were small-scale and examined confined population groups. Most studies had been performed in Finland, utilizing data from nationwide registries. Women with previous history of total hip arthroplasty feature increased rates of c-section delivery, although vaginal labor can be attempted with certain precautions. Hip implants' survival does not appear to be affected from gestation, which is predominately well-tolerated from these women. Metal ion circulation in mothers' blood has not been proven to trigger substantial complications concerning either mothers or offspring. It can be considered safe for women with such medical history to get pregnant; however, further multinational studies and pertinent research on this field are vital to attain more solid inferences.

11.
Clin Case Rep ; 11(6): e7465, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37287621

RESUMO

Key Clinical Message: The treatment of long bone fractures in post-polio survivors is indubitably an exacting task. Out of this complicated case presented in this paper, it can be deduced that it is attainable to repair a peri-implant subtrochanteric refracture or a complex non-union of the proximal femur with plate and screws with grafting. Abstract: Post-polio survivors are prone to low-energy bone fractures. The management of such cases is exigent, as no literature data indicate the best surgical approach. This paper presents an intricate peri-implant proximal femoral fracture in a polio survivor treated in our institution and accentuates the various challenges we encountered.

12.
Diagnostics (Basel) ; 13(15)2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37568972

RESUMO

Hip pain is indubitably a frequent clinical problem deriving from copious etiologies. Hip impingement syndromes are one of the most prevalent causes of persistent groin pain, especially in young and active patients. Diligent imaging of the hip region is indispensable to discern femoroacetabular impingement, as the differential diagnosis of hip pain can be exceedingly arduous. Despite hip radiography being plain and broadly attainable, it offers narrow information concerning soft tissue pathologies around the hip joint (extra-articular hip impingement syndromes). Magnetic resonance imaging and arthrography remain the gold standard examination for detecting intra-articular pathologies; however, they are widely considered expensive, time-consuming and characterized by confined. Consequently, ultrasonography has emerged as an alternative valuable diagnostic tool for distinguishing the underlying abnormalities that trigger femoroacetabular impingement. Proper hip ultrasound examination provides dynamic assessment, while also beneficial for guided intervention around the hip joint. Ultrasound hip examination is exacting due to its complex regional anatomy and deep location. It is capable of providing detailed information about various hip quadrants. An adept operator can identify both intra-articular and extra-articular pathologies. In addition, with ultrasonography, hip injections have been rendered relatively undemanding, aiding in therapeutic and diagnostic purposes. This paper aims to provide a succinct and compendious review of the existing literature, accentuating the crucial role of ultrasonography in diagnosing hip impingement syndromes and determining whether an additional examination is required regarding distinguishing between intra-articular and extra-articular syndromes.

13.
Medicine (Baltimore) ; 102(37): e34653, 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37713867

RESUMO

Spinal cord injuries at the cervical spine level represent the most consequential of the related injuries at all levels of the spine. They can trigger permanent unilateral or bilateral damage with conspicuous disability. Regarding unstable injuries, the gold standard approach is open reduction and osteosynthesis, which can select between anterior and posterior surgical access. Each of the aforementioned approaches demonstrates both advantages and disadvantages; thus, it is up to the surgeon to determine the optimal option concerning the patient's safety. Diligent intraoperative control of anatomical reduction is pivotal to obtaining the best feasible postoperative outcomes. Literature data delineate copious complications following surgical intervention in the cervical spine. Indubitably, the most crucial intraoperative complication accounts for vascular injuries, with the most preponderant being the corrosion of the vertebral artery, as it is potentially life-threatening. This paper aims to provide a succinct and compendious review of the existing literature regarding cervical spinal cord injuries and to deduce many inferences concerning the incidence of iatrogenic vertebral artery injuries in relation to the surgical approach for fracture reduction.


Assuntos
Traumatismos Craniocerebrais , Lesões do Pescoço , Traumatismos da Medula Espinal , Humanos , Incidência , Artéria Vertebral , Traumatismos da Medula Espinal/epidemiologia , Traumatismos da Medula Espinal/etiologia , Vértebras Cervicais/cirurgia
14.
Medicine (Baltimore) ; 102(41): e35475, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37832084

RESUMO

Transient osteoporosis of the hip is indubitably a comparatively infrequent entity affecting both men and women worldwide. Its occurrence in the course of pregnancy, specifically in the third trimester, and lactation are of paramount concernment. The exact association between transient hip osteoporosis and pregnancy is precarious. Etiology and potential pathophysiological mechanisms behind this correlation are still to be utterly defined. Magnetic resonance imaging is highly regarded as the gold standard imaging method for assiduous assessment of this disorder. Physicians of copious medical specialties should practice scrupulous techniques for early and pertinent diagnosis when pregnant women are presented with persistent hip pain, as differential diagnosis with femoral head avascular necrosis can be exceedingly arduous. Treatment is predominantly conservative with protected weight-bearing and analgesic medication in the first line of management. In terms of prognosis, the disease ordinarily resolves spontaneously after a few months. Further research is required in order to elucidate the ambiguity surrounding the establishment of globally approved diagnosis and treatment guidelines for pregnancy-associated transient hip osteoporosis. This paper aims to accentuate the significance of this particular disorder by providing a succinct review of the existing literature, augmenting clinicians' knowledge about the features of pregnancy-related transient proximal femur osteoporosis.


Assuntos
Osteoporose , Complicações na Gravidez , Masculino , Feminino , Humanos , Gravidez , Complicações na Gravidez/tratamento farmacológico , Osteoporose/complicações , Osteoporose/diagnóstico , Osteoporose/tratamento farmacológico , Quadril , Articulação do Quadril/patologia , Imageamento por Ressonância Magnética/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA