1.
J Appl Clin Med Phys ; 25(6): e14359, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38689502

RESUMO

PURPOSE: AAPM Task Group No. 263U1 (Update to Report No. 263 - Standardizing Nomenclatures in Radiation Oncology) disseminated a survey to receive feedback on utilization, gaps, and means to facilitate further adoption. METHODS: The survey was created by TG-263U1 members to solicit feedback from physicists, dosimetrists, and physicians working in radiation oncology. Questions on the adoption of the TG-263 standard were coupled with demographic information, such as clinical role, place of primary employment (e.g., private hospital, academic center), and size of institution. The survey was emailed to all AAPM, AAMD, and ASTRO members. RESULTS: The survey received 463 responses with 310 completed survey responses used for analysis, of whom most had the clinical role of medical physicist (73%) and the majority were from the United States (83%). There were 83% of respondents who indicated that they believe that having a nomenclature standard is important or very important and 61% had adopted all or portions of TG-263 in their clinics. For those yet to adopt TG-263, the staffing and implementation efforts were the main cause for delaying adoption. Fewer respondents had trouble adopting TG-263 for organs at risk (29%) versus target (44%) nomenclature. Common themes in written feedback were lack of physician support and available resources, especially in vendor systems, to facilitate adoption. CONCLUSIONS: While there is strong support and belief in the benefit of standardized nomenclature, the widespread adoption of TG-263 has been hindered by the effort needed by staff for implementation.  Feedback from the survey is being utilized to drive the focus of the update efforts and create tools to facilitate easier adoption of TG-263.


Assuntos
Radioterapia (Especialidade) , Terminologia como Assunto , Humanos , Radioterapia (Especialidade)/normas , Inquéritos e Questionários , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Guias de Prática Clínica como Assunto , Percepção
2.
J Appl Clin Med Phys ; 23(11): e13810, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36316761

RESUMO

PURPOSE: To quantify the clinical practice of respiratory motion management in radiation oncology. METHODS: A respiratory motion management survey was designed and conducted based on clinician survey guidelines. The survey was administered to American Association of Physicists in Medicine (AAPM) members on 17 August 2020 and closed on 13 September 2020. RESULTS: A total of 527 respondents completed the entire survey and 651 respondents completed part of the survey, with the partially completed surveys included in the analysis. Overall, 84% of survey respondents used deep inspiration breath hold for left-sided breast cancer. Overall, 83% of respondents perceived respiratory motion management for thoracic and abdominal cancer radiotherapy patients to be either very important or required. Overall, 95% of respondents used respiratory motion management for thoracic and abdominal sites, with 36% of respondents using respiratory motion management for at least 90% of thoracic and abdominal patients. The majority (60%) of respondents used the internal target volume method to treat thoracic and abdominal cancer patients, with 25% using breath hold or abdominal compression and 13% using gating or tracking. CONCLUSIONS: A respiratory motion management survey has been completed by AAPM members. Respiratory motion management is generally considered very important or required and is widely used for breast, thoracic, and abdominal cancer treatments.


Assuntos
Radioterapia (Especialidade) , Humanos , Estados Unidos , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos , Suspensão da Respiração , Movimento (Física) , Planejamento da Radioterapia Assistida por Computador/métodos , Inquéritos e Questionários
3.
J Appl Clin Med Phys ; 21(1): 95-102, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31943756

RESUMO

Current available secondary dose calculation software for Gamma Knife radiosurgery falls short in situations where the target is shallow in depth or when the patient is positioned with a gamma angle other than 90°. In this work, we evaluate a new secondary calculation software which utilizes an innovative method to handle nonstandard gamma angles and image thresholding to render the skull for dose calculation. 800 treatment targets previously treated with our GammaKnife Icon system were imported from our treatment planning system (GammaPlan 11.0.3) and a secondary dose calculation was conducted. The agreement between the new calculations and the TPS were recorded and compared to the original secondary dose calculation agreement with the TPS using a Wilcoxon Signed Rank Test. Further comparisons using a Mann-Whitney test were made for targets treated at a 90° gamma angle against those treated with either a 70 or 110 gamma angle for both the new and commercial secondary dose calculation systems. Correlations between dose deviations from the treatment planning system against average target depth were evaluated using a Kendall's Tau correlation test for both programs. The Wilcoxon Signed Rank Test indicated a significant difference in the agreement between the two secondary calculations and the TPS, with a P-value < 0.0001. With respect to patients treated at nonstandard gamma angles, the new software was largely independent of patient setup, while the commercial software showed a significant dependence (P-value < 0.0001). The new secondary dose calculation software showed a moderate correlation with calculation depth, while the commercial software showed a weak correlation (Tau = -.322 and Tau = -.217 respectively). Overall, the new secondary software has better agreement with the TPS than the commercially available secondary calculation software over a range of diverse treatment geometries.


Assuntos
Órgãos em Risco/efeitos da radiação , Imagens de Fantasmas , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Cranianas/cirurgia , Software , Humanos , Processamento de Imagem Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Neoplasias Cranianas/diagnóstico por imagem , Neoplasias Cranianas/patologia , Tomografia Computadorizada por Raios X/métodos
4.
J Appl Clin Med Phys ; 20(5): 21-26, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31055877

RESUMO

PURPOSE: Characterize the intra-fraction motion management (IFMM) system found on the Gamma Knife Icon (GKI), including spatial accuracy, latency, temporal performance, and overall effect on delivered dose. METHODS: A phantom was constructed, consisting of a three-axis translation mount, a remote motorized flipper, and a thermoplastic sphere surrounding a radiation detector. An infrared marker was placed on the translation mount secured to the flipper. The spatial accuracy of the IFMM was measured via the translation mount in all Cartesian planes. The detector was centered at the radiation focal point. A remote signal was used to move the marker out of the IFMM tolerance and pause the beam. A two-channel electrometer was used to record the signals from the detector and the flipper when motion was signaled. These signals determined the latency and temporal performance of the GKI. RESULTS: The spatial accuracy of the IFMM was found to be <0.1 mm. The measured latency was <200 ms. The dose difference with five interruptions was <0.5%. CONCLUSION: This work provides a quantitative characterization of the GKI IFMM system as required by the Nuclear Regulatory Commission. This provides a methodology for GKI users to satisfy these requirements using common laboratory equipment in lieu of a commercial solution.


Assuntos
Movimento , Neoplasias/cirurgia , Imagens de Fantasmas , Radiocirurgia/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Desenho de Equipamento , Humanos , Radiometria/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
5.
Acta Neurochir (Wien) ; 160(7): 1343-1347, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29455411

RESUMO

BACKGROUND AND IMPORTANCE: Gamma Knife radiosurgery is an established technique for non-urgent treatment of various intracranial pathologies. Intra-procedural dislodgement of the stereotactic frame is an uncommon occurrence that could lead to abortion of ongoing treatment and necessitate more invasive treatment strategies. CLINICAL PRESENTATION: In this case report, we describe a novel method for resumption of Gamma Knife treatment after an unplanned intra-procedural interruption. The case example involves a radiosurgical treatment of a Spetzler-Martin grade I arteriovenous malformation. CONCLUSION: Our technique involves integration of scans and coordinate systems from two imaging sessions using the composite isodose line to resolve translational differences, thereby limiting delivery of remaining shots to the untreated region of the lesion. MRI follow-up at 13 months showed a reduction in the nidus size with no evidence of any radiation injury to the surrounding brain parenchyma. We believe this technique will allow care teams to effectively salvage interrupted Gamma Knife procedures and reduce progression to more invasive treatment options.


Assuntos
Falha de Equipamento , Malformações Arteriovenosas Intracranianas/cirurgia , Complicações Pós-Operatórias/etiologia , Radiocirurgia/efeitos adversos , Idoso , Humanos , Masculino , Complicações Pós-Operatórias/terapia , Radiocirurgia/instrumentação , Radiocirurgia/métodos , Terapia de Salvação/métodos
6.
J Appl Clin Med Phys ; 17(2): 24-40, 2016 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-27074470

RESUMO

The purpose of this study is to describe the comprehensive commissioning process and initial clinical experience of the Mevion S250 proton therapy system, a gantry-mounted, single-room proton therapy platform clinically implemented in the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital in St. Louis, MO, USA. The Mevion S250 system integrates a compact synchrocyclotron with a C-inner gantry, an image guidance system and a 6D robotic couch into a beam delivery platform. We present our commissioning process and initial clinical experience, including i) CT calibration; ii) beam data acquisition and machine characteristics; iii) dosimetric commissioning of the treatment planning system; iv) validation through the Imaging and Radiation Oncology Core credentialing process, including irradiations on the spine, prostate, brain, and lung phantoms; v) evaluation of localization accuracy of the image guidance system; and vi) initial clinical experience. Clinically, the system operates well and has provided an excellent platform for the treatment of diseases with protons.


Assuntos
Neoplasias/radioterapia , Posicionamento do Paciente , Imagens de Fantasmas , Terapia com Prótons/instrumentação , Terapia com Prótons/normas , Prótons , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Rotação , Tomografia Computadorizada por Raios X
9.
Med Phys ; 39(4): 1728-47, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22482598

RESUMO

New technologies continue to be developed to improve the practice of radiation therapy. As several of these technologies have been implemented clinically, the Therapy Committee and the Quality Assurance and Outcomes Improvement Subcommittee of the American Association of Physicists in Medicine commissioned Task Group 147 to review the current nonradiographic technologies used for localization and tracking in radiotherapy. The specific charge of this task group was to make recommendations about the use of nonradiographic methods of localization, specifically; radiofrequency, infrared, laser, and video based patient localization and monitoring systems. The charge of this task group was to review the current use of these technologies and to write quality assurance guidelines for the use of these technologies in the clinical setting. Recommendations include testing of equipment for initial installation as well as ongoing quality assurance. As the equipment included in this task group continues to evolve, both in the type and sophistication of technology and in level of integration with treatment devices, some of the details of how one would conduct such testing will also continue to evolve. This task group, therefore, is focused on providing recommendations on the use of this equipment rather than on the equipment itself, and should be adaptable to each user's situation in helping develop a comprehensive quality assurance program.


Assuntos
Posicionamento do Paciente/normas , Guias de Prática Clínica como Assunto , Garantia da Qualidade dos Cuidados de Saúde/normas , Radioterapia Conformacional/normas , Radioterapia Guiada por Imagem/normas
10.
Pract Radiat Oncol ; 12(4): e253-e268, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35283342

RESUMO

PURPOSE: This updated report on stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) is part of a series of consensus-based white papers previously published addressing patient safety. Since the first white papers were published, SRS and SBRT technology and procedures have progressed significantly such that these procedures are now more commonly used. The complexity and submillimeter accuracy, and delivery of a higher dose per fraction requires an emphasis on best practices for technical, dosimetric, and quality assurance. Therefore, quality and patient safety considerations for these techniques remain an important area of focus. METHOD: The American Society for Radiation Oncology convened a task force to assess the original SRS/SBRT white paper and update content where appropriate. Recommendations were created using a consensus-building methodology and task force members indicated their level of agreement based on a 5-point Likert scale, from "strongly agree" to "strongly disagree." A prespecified threshold of ≥75% of raters who select "strongly agree" or "agree" indicated consensus. SUMMARY: This white paper builds on the previous version and uses of other guidance documents to broadly address SRS and SBRT delivery, primarily focusing on processes related to quality and safety. SRS and SBRT require a team-based approach, staffed by appropriately trained and credentialed specialists as well as significant personnel resources, specialized technology, and implementation time. A thorough feasibility analysis of resources is required to achieve the clinical and technical goals and thoroughly discussed with all personnel before undertaking new disease sites. A comprehensive quality assurance program must be developed, using established treatment guidelines, to ensure SRS and SBRT are performed in a safe and effective manner. Patient safety in SRS/SBRT is everyone's responsibility and professional organizations, regulators, vendors, and end-users must demonstrate a clear commitment to working together to ensure the highest levels of safety.


Assuntos
Radioterapia (Especialidade) , Radiocirurgia , Consenso , Humanos , Radiometria , Radiocirurgia/métodos
11.
Med Phys ; 48(6): e86-e114, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33780010

RESUMO

With the advancement of data-intensive technologies, such as image-guided radiation therapy (IGRT) and intensity-modulated radiation therapy (IMRT), the amount and complexity of data to be transferred between clinical subsystems have increased beyond the reach of manual checking. As a result, unintended treatment deviations (e.g., dose errors) may occur if the treatment system is not closely monitored by a comprehensive data transfer quality management program (QM). This report summarizes the findings and recommendations from the task group (TG) on quality assurance (QA) of external beam treatment data transfer (TG-201), with the aim to assist medical physicists in designing their own data transfer QM. As a background, a section of this report describes various models of data flow (distributed data repositories and single data base systems) and general data test characteristics (data integrity, interpretation, and consistency). Recommended tests are suggested based on the collective experience of TG-201 members. These tests are for the acceptance of, commissioning of, and upgrades to subsystems that store and/or modify clinical treatment data. As treatment complexity continues to evolve, we will need to do and know more about ensuring the quality of data transfers. The report concludes with the recommendation to move toward data transfer open standards compatibility and to develop tools that automate data transfer QA.


Assuntos
Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Relatório de Pesquisa , Estados Unidos
12.
Med Phys ; 48(5): e44-e64, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33260251

RESUMO

The era of real-time radiotherapy is upon us. Robotic and gimbaled linac tracking are clinically established technologies with the clinical realization of couch tracking in development. Multileaf collimators (MLCs) are a standard equipment for most cancer radiotherapy systems, and therefore MLC tracking is a potentially widely available technology. MLC tracking has been the subject of theoretical and experimental research for decades and was first implemented for patient treatments in 2013. The AAPM Task Group 264 Safe Clinical Implementation of MLC Tracking in Radiotherapy Report was charged to proactively provide the broader radiation oncology community with (a) clinical implementation guidelines including hardware, software, and clinical indications for use, (b) commissioning and quality assurance recommendations based on early user experience, as well as guidelines on Failure Mode and Effects Analysis, and (c) a discussion of potential future developments. The deliverables from this report include: an explanation of MLC tracking and its historical development; terms and definitions relevant to MLC tracking; the clinical benefit of, clinical experience with and clinical implementation guidelines for MLC tracking; quality assurance guidelines, including example quality assurance worksheets; a clinical decision pathway, future outlook and overall recommendations.


Assuntos
Radioterapia (Especialidade) , Robótica , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
13.
J Appl Clin Med Phys ; 12(1): 3338, 2010 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-21330981

RESUMO

A procedure for periodic quality assurance of a video surface imaging system is introduced. AlignRT is a video camera-based patient localization system that captures and compares images of a patient's topography to a DICOM-formatted external contour, then calculates shifts required to accurately reposition the patient. This technical note describes the tools and methods implemented in our department to verify correct and accurate operation of the AlignRT hardware and software components. The procedure described is performed monthly and complements a daily calibration of the system.


Assuntos
Imageamento Tridimensional/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Calibragem , Humanos , Imagens de Fantasmas , Controle de Qualidade , Dosagem Radioterapêutica
14.
J Appl Clin Med Phys ; 12(1): 3479, 2010 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-21330992

RESUMO

The transfer of radiation therapy data among the various subsystems required for external beam treatments is subject to error. Hence, the establishment and management of a data transfer quality assurance program is strongly recommended. It should cover the QA of data transfers of patient specific treatments, imaging data, manually handled data and historical treatment records. QA of the database state (logical consistency and information integrity) is also addressed to ensure that accurate data are transferred.


Assuntos
Bases de Dados Factuais , Radioterapia (Especialidade)/métodos , Radioterapia/métodos , Relatório de Pesquisa , Humanos , Imagens de Fantasmas , Controle de Qualidade , Radioterapia (Especialidade)/normas , Radioterapia/normas , Dosagem Radioterapêutica
15.
Med Phys ; 36(8): 3477-86, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19746781

RESUMO

The Calypso Medical 4D localization system utilizes alternating current electromagnetics for accurate, real-time tumor tracking. A quality assurance program to clinically implement this system is described here. Testing of the continuous electromagnetic tracking system (Calypso Medical Technologies, Seattle, WA) was performed using an in-house developed four-dimensional stage and a quality assurance fixture containing three radiofrequency transponders at independently measured locations. The following tests were performed to validate the Calypso system: (a) Localization and tracking accuracy, (b) system reproducibility, (c) measurement of the latency of the tracking system, and (d) measurement of transmission through the Calypso table overlay and the electromagnetic array. The translational and rotational localization accuracies were found to be within 0.01 cm and 1.0 degree, respectively. The reproducibility was within 0.1 cm. The average system latency was measured to be within 303 ms. The attenuation by the Calypso overlay was measured to be 1.0% for both 6 and 18 MV photons. The attenuations by the Calypso array were measured to be 2% and 1.5% for 6 and 18 MV photons, respectively. For oblique angles, the transmission was measured to be 3% for 6 MV, while it was 2% for 18 MV photons. A quality assurance process has been developed for the clinical implementation of an electromagnetic tracking system in radiation therapy.


Assuntos
Fenômenos Eletromagnéticos , Radioterapia/instrumentação , Radioterapia/normas , Segurança de Equipamentos , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Movimento (Física) , Controle de Qualidade , Reprodutibilidade dos Testes
16.
Brachytherapy ; 8(4): 379-84, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19748834

RESUMO

PURPOSE: As experience with the MammoSite device for accelerated partial breast irradiation (APBI) has increased, more centers are starting to use three-dimensional (3D) treatment planning to generate plans with multiple nonequally weighted dwell positions. This report presents the use of serial computed tomography (CT) imaging, in addition to planar or ultrasound imaging, for the quality assurance of an APBI treatment using the elliptical MammoSite. METHODS AND MATERIALS: CT images of a patient implanted with a 4cmx6cm elliptical MammoSite balloon were acquired. A treatment plan using multiple, nonequally weighted dwells was generated and delivered on Day 1 of a 10-fraction, twice-daily treatment. Before morning treatments on Days 2-5, the patient was reimaged on CT. Treatment plans on repeat CTs were generated two ways: using the decay-corrected plan from Day 1 (unadapted) vs. modifying the plan to account for changes in implant geometry (adapted). Adapted and unadapted plans on repeat CTs were compared with one another, and to the Day 1 plan. RESULTS: The use of unadapted plans led to increased doses to normal tissues, particularly the skin. Adaptive planning on the repeat CTs was effective for maintaining acceptable dosimetry throughout treatment. CONCLUSIONS: Serial CT imaging was shown to provide a useful tool for the quality assurance of an elliptical balloon implant during the course of treatment. Serial CT imaging, as opposed to planar or ultrasound imaging, was necessary to evaluate skin dose and to facilitate adaptation of the treatment plan to satisfy limits for skin dose.


Assuntos
Braquiterapia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Radioterapia de Intensidade Modulada , Tomografia Computadorizada por Raios X , Idoso , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mastectomia Segmentar , Garantia da Qualidade dos Cuidados de Saúde , Planejamento da Radioterapia Assistida por Computador
17.
Neurosurg Focus ; 26(5): E13, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19408991

RESUMO

This report demonstrates that time-of-flight (TOF) MR angiography is a useful adjunct for planning stereotactic radiosurgery (SRS) of large arteriovenous malformations (AVMs) after staged embolization with Onyx. Onyx (ethylene vinyl copolymer), a recently approved liquid embolic agent, has been increasingly used to exclude portions of large AVMs from the parent circulation prior to SRS. Limiting SRS to regions of persistent arteriovenous shunting and excluding regions eliminated by embolization may reduce unnecessary radiation doses to eloquent brain structures. However, SRS dosimetry planning presents unique challenges after Onyx embolization because it creates extensive artifacts on CT scans, and it cannot be delineated from untreated nidus on standard MR sequences. During the radiosurgery procedure, MR images were obtained using a GE Signa 1.5-T unit. Standard axial T2 fast spin echo high-resolution images (TR 3000 msec, TE 108 msec, slice thickness 2.5 mm) were generated for optimal visualization of brain tissue and AVM flow voids. The 3D TOF MR angiography images of the circle of Willis and vertebral arteries were subsequently obtained to visualize AVM regions embolized with Onyx (TR 37 msec, TE 6.9 msec, flip angle 20 degrees). Adjunct TOF MR angiography images demonstrated excellent contrast between nidus embolized with Onyx and regions of persistent arteriovenous shunting within a large AVM prior to SRS. Additional information derived from these sequences resulted in substantial adjustments to the treatment plan and an overall reduction in the treated tissue volume.


Assuntos
Dimetil Sulfóxido/uso terapêutico , Embolização Terapêutica/métodos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/cirurgia , Angiografia por Ressonância Magnética/métodos , Polivinil/uso terapêutico , Radiocirurgia/métodos , Adulto , Artefatos , Artéria Basilar/diagnóstico por imagem , Artéria Basilar/patologia , Artéria Basilar/cirurgia , Tronco Encefálico/irrigação sanguínea , Tronco Encefálico/fisiopatologia , Dimetil Sulfóxido/efeitos adversos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Malformações Arteriovenosas Intracranianas/patologia , Polivinil/efeitos adversos , Valor Preditivo dos Testes , Cuidados Pré-Operatórios/métodos , Reoperação/métodos , Prevenção Secundária , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos
18.
Int J Radiat Oncol Biol Phys ; 70(3): 892-9, 2008 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-18262100

RESUMO

PURPOSE: The Calypso medical four-dimensional localization system uses AC electromagnetics, which do not require ionizing radiation, for accurate, real-time tumor tracking. This investigation compared the static and dynamic tracking accuracy of this system to that of an on-board imaging kilovoltage X-ray system for concurrent use of the two systems. METHODS AND MATERIALS: The localization accuracies of a kilovoltage imaging system and a continuous electromagnetic tracking system were compared. Using an in-house developed four-dimensional stage, quality-assurance fixture containing three radiofrequency transponders was positioned at a series of static locations and then moved through the ellipsoidal and nonuniform continuous paths. The transponder positions were tracked concurrently by the Calypso system. For static localization, the transponders were localized using portal images and digitally reconstructed radiographs by commercial matching software. For dynamic localization, the transponders were fluoroscopically imaged, and their positions were determined retrospectively using custom-written image processing programs. The localization data sets were synchronized with and compared to the known quality assurance fixture positions. The experiment was repeated to retrospectively track three transponders implanted in a canine lung. RESULTS: The root mean square error of the on-board imaging and Calypso systems was 0.1 cm and 0.0 cm, respectively, for static localization, 0.22 mm and 0.33 mm for dynamic phantom positioning, and 0.42 mm for the canine study. CONCLUSION: The results showed that both localization systems provide submillimeter accuracy. The Calypso and on-board imaging tracking systems offer distinct sets of advantages and, given their compatibility, patients could benefit from the complementary nature of the two systems when used concurrently.


Assuntos
Fenômenos Eletromagnéticos/instrumentação , Próteses e Implantes , Planejamento da Radioterapia Assistida por Computador/instrumentação , Animais , Cães , Fenômenos Eletromagnéticos/métodos , Desenho de Equipamento , Pulmão , Movimento , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Respiração
19.
Int J Radiat Oncol Biol Phys ; 71(5): 1511-7, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18538499

RESUMO

PURPOSE: This prospective study investigates gynecologic malignancy online treatment setup error corrections using planar kilovoltage/megavoltage (KV/MV) imaging and helical MV computed tomography (MVCT) imaging. METHODS AND MATERIALS: Twenty patients were divided into two groups. The first group (10 patients) was imaged and treated using a conventional linear accelerator (LINAC) with image-guidance capabilities, whereas the second group (10 patients) was treated using tomotherapy with MVCT capabilities. Patients treated on the LINAC underwent planar KV and portal MV imaging and a two-dimensional image registration algorithm was used to match these images to digitally reconstructed radiographs (DRRs). Patients that were treated using tomotherapy underwent MVCT imaging, and a three-dimensional image registration algorithm was used to match planning CT to MVCT images. Subsequent repositioning shifts were applied before each treatment and recorded for further analysis. To assess intrafraction motion, 5 of the 10 patients treated on the LINAC underwent posttreatment planar imaging and DRR matching. Based on these data, patient position uncertainties along with estimated margins based on well-known recipes were determined. RESULTS: The errors associated with patient positioning ranged from 0.13 cm to 0.38 cm, for patients imaged on LINAC and 0.13 cm to 0.48 cm for patients imaged on tomotherapy. Our institutional clinical target volume-PTV margin value of 0.7 cm lies inside the confidence interval of the margins established using both planar and MVCT imaging. CONCLUSION: Use of high-quality daily planar imaging, volumetric MVCT imaging, and setup corrections yields excellent setup accuracy and can help reduce margins for the external beam treatment of gynecologic malignancies.


Assuntos
Neoplasias do Endométrio/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Neoplasias do Endométrio/radioterapia , Neoplasias do Endométrio/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade , Movimento , Postura , Estudos Prospectivos , Lesões por Radiação/prevenção & controle , Radiocirurgia , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada Espiral/métodos , Incerteza , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/cirurgia
20.
Pract Radiat Oncol ; 8(2): 123-132, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29329998

RESUMO

PURPOSE: The Radiation Oncology Incident Learning System (RO-ILS) receives event reports from facilities across the country. This effort extracted common error pathways seen in the data. These pathways, expressed as fault trees, demonstrate the need for, and opportunities for, preventing these errors and/or limiting their propagation to treatment. METHODS AND MATERIALS: As of the third quarter of 2016, 2344 event reports had been submitted to RO-ILS and reviewed. A total of 396 of the reports judged highest priority were rereviewed and assigned up to 3 keywords to classify events. Based on patterns among the keyword assignments, the data were further aggregated into pathways leading to 3 general error types: "problematic plan approved for treatment," "wrong shift instructions given to therapists," and "wrong shift performed at treatment." Fault trees were created showing how different errors at different stages in the treatment process combine to flow into these general error types. RESULTS: A total of 173 of the 396 (44%) events were characterized as belonging to 1 of these 3 general error types. Ninety-nine events were defined as "problematic plan approved for treatment," 40 as "wrong shift instructions given to therapists," and 34 as "wrong shift performed at treatment." Seventy-six of these events (44%) resulted in incorrectly delivered treatment. Event discovery was by therapists (n = 76), physicists (n = 45), physicians (n = 23), dosimetrists (n = 15), or not identified (n = 9); 5 events were found as a result of the patient questioning the staff. For the event type "problematic plan approved for treatment," 64 of the 99 (65%) events were attributable to physician error: incorrect target or dosing pattern prescribed. CONCLUSIONS: Data extracted from RO-ILS event reports demonstrate common error pathways in radiation oncology that propagate all the way to treatment. Additional study and coordination of efforts is needed to develop and share best practices to address the sources of these errors and curtail their propagation.


Assuntos
Erros Médicos/prevenção & controle , Radioterapia (Especialidade)/ética , Gestão de Riscos/métodos , Humanos