1.
Echocardiography ; 32(12): 1790-801, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25925784

RESUMO

BACKGROUND: Whether an intervendor discordance of myocardial velocities determined by tissue Doppler echocardiography (TDE) can be generalized remains unclear. We compared intervendor variabilities of left ventricular (LV) and right ventricular (RV) myocardial velocities among three TDE systems. METHODS: Examinations with TDE were performed in 41 healthy subjects and 11 patients with cardiovascular risk factors (CVR) using α-7 (V1, Hitachi Aloka Medical), Artida (V2, Toshiba Medical Systems), and Vivid E9 (V3, GE Healthcare) on the same day. Peak systolic (s'), early diastolic (e'), and late diastolic (a') myocardial velocities at medial and lateral sites of the mitral annulus and lateral site of the tricuspid annulus were measured using both pulsed-wave TDE and color TDE. Intra-observer and inter-observer variabilities were determined in 10 subjects and test-retest variability in 14 subjects. RESULTS: As for test-retest variability, reproducibilities of LV and RV myocardial velocities determined by pulsed-wave TDE and color TDE were relatively low but comparable between V1, V2, and V3. Myocardial velocities in healthy subjects determined by both pulsed-wave TDE and color TDE were significantly different among the three TDE systems. Myocardial velocities by pulsed-wave TDE in V3 were 2-12% lower (P < 0.05) than those by V2 and 5-14% lower (P < 0.05) than those by V1. Similar differences in myocardial velocities determined by both pulsed-wave TDE and color TDE were found in patients with CVR. CONCLUSIONS: LV and RV myocardial velocities determined by both pulsed-wave TDE and color TDE are vendor dependent, and reproducibility of the myocardial velocities determined by both TDE systems is relatively low.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Volume Sistólico , Disfunção Ventricular/diagnóstico por imagem , Disfunção Ventricular/fisiopatologia , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Echocardiography ; 31(5): 597-604, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-25070187

RESUMO

BACKGROUND: Inter-vendor discordance in three-dimensional speckle-tracking echocardiography (3DS) remains uncharacterized. We aimed to examine inter-vendor discordance of left ventricular (LV) volumes, and functional parameters and their reproducibilities between two commercially available 3DS systems. METHODS: Echocardiographic examinations with 3DS were performed in 26 healthy subjects (age 34 ± 13 years, 85% men) using a Vivid E9 system (V1) with 4V probe (GE Health Care) and Artida (V2) with PST-25SX probe (Toshiba Medical Systems) on the same day. LV variables and global LV longitudinal, circumferential, radial, and area strains were measured by vendor-specific softwares, 4D strain EchoPAC BT11 (for V1) and 3D WMT (for V2), respectively. Reproducibility of data was assessed by an intra-class correlation coefficient (ICC). RESULTS: The mean time required for 3DS analysis was 5.4 ± 1.5 min for V1, being 21% less than that for V2 (6.8 ± 1.9 min, P < 0.01). Reproducibilities of all LV strains were comparable between V1 (ICC 0.50-0.82) and V2 (ICC 0.51-0.76), except for intra-observer and inter-observer reproducibilities of radial strain being lower in V2 (ICC for V1 0.82 and 0.82 and ICC for V2 0.44 and 0.40, respectively). LV strains in all directions and area were significantly different between V1 and V2, though LV volumes and ejection fraction were comparable. CONCLUSIONS: Global longitudinal, circumferential, and area LV strains are reproducible in both 3DS vendors. However, values of three-dimensional LV strains by 3DS are highly vendor-dependent.


Assuntos
Algoritmos , Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Adulto , Estudos Transversais , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
3.
J Med Ultrason (2001) ; 43(1): 91-4, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26703172

RESUMO

We report a case of unroofed coronary sinus (URCS) in a 42-year-old female. At an outpatient clinic, she was found to have an atrioventricular septal defect and mitral regurgitation with pulmonary hypertension, and she was transferred to our institute for surgical treatment. Both atrioventricular valves were located at the same level, and both the right atrium (RA) and right ventricle were enlarged on two-dimensional transthoracic echocardiography. Color Doppler imaging demonstrated severe mitral and tricuspid regurgitation and a left-to-right shunt from the left atrium (LA) to the RA. Although an ostium primum defect of the atrial septum was suspected, the exact position of the shunt flow was unclear. Two-dimensional transesophageal echocardiography (2D-TEE) could visualize a direct communication between the LA and coronary sinus. Three-dimensional transesophageal echocardiography (3D-TEE) clearly visualized the entire route from the coronary sinus into the LA and RA. The utility of 3D-TEE as a modality complementary to 2D-TEE in diagnosis of URCS was confirmed.


Assuntos
Seio Coronário/anormalidades , Seio Coronário/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Adulto , Seio Coronário/cirurgia , Ecocardiografia Doppler em Cores/métodos , Feminino , Humanos