Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Clin Chem Lab Med ; 45(10): 1373-80, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17924850

RESUMO

BACKGROUND: The improvement of the consistency of gamma-glutamyltransferase (GGT) activity results among different assays after calibration with a common material was estimated. We evaluated if this harmonization could lead to reference limits common to different routine methods. METHODS: Seven laboratories measured GGT activity using their own routine analytical system both according to the manufacturer's recommendation and after calibration with a multi-enzyme calibrator [value assigned by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference procedure]. All samples were re-measured using the IFCC reference procedure. Two groups of subjects were selected in each laboratory: a group of healthy men aged 18-25 years without long-term medication and with alcohol consumption less than 44 g/day and a group of subjects with elevated GGT activity. RESULTS: The day-to-day coefficients of variation were less than 2.9% in each laboratory. The means obtained in the group of healthy subjects without common calibration (range of the means 16-23 U/L) were significantly different from those obtained by the IFCC procedure in five laboratories. After calibration, the means remained significantly different from the IFCC procedure results in only one laboratory. For three calibrated methods, the slope values of linear regression vs. the IFCC procedure were not different from the value 1. The results obtained with these three methods for healthy subjects (n=117) were gathered and reference limits were calculated. These were 11-49 U/L (2.5th-97.5th percentiles). The calibration also improved the consistency of elevated results when compared to the IFCC procedure. CONCLUSIONS: The common calibration improved the level of consistency between different routine methods. It permitted to define common reference limits which are quite similar to those proposed by the IFCC. This approach should lead to a real benefit in terms of prevention, screening, diagnosis, therapeutic monitoring and for epidemiological studies.


Assuntos
Bioensaio/normas , Técnicas de Laboratório Clínico/normas , gama-Glutamiltransferase/normas , Adolescente , Adulto , Calibragem , Humanos , Modelos Lineares , Masculino , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo , gama-Glutamiltransferase/sangue
2.
Clin Chem ; 48(2): 291-300, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11805010

RESUMO

BACKGROUND: Apolipoprotein (apo) E is a component of two major classes of plasma lipoproteins, apo B- (apo E-LpB) and non-apo B-containing (apo E-Lp-non-B) lipoproteins. The factors that affect total apo E in particles [lipoprotein E (LpE), apo E-Lp-non-B, and apo E-LpB], are incompletely characterized. METHODS: We studied the determinants of these lipoparticles in a sample population of presumably healthy individuals: 1784 children (age range, 8-18 years) and 1739 adults (age range, 19-50 years). Serum concentrations of LpE and apo E-Lp-non-B were measured by electroimmunoassays, and the concentration of apo E-LpB was calculated by a difference method. RESULTS: Serum LpE and apo E-Lp-non-B were higher in females than in males. Their concentrations decreased with age until 20-25 years and then increased in men but not in women. apo E-LpB concentrations increased up to 20-25 years and were similar in both sexes. Thereafter, adult men had higher values than women. Individuals carrying the epsilon2 allele had higher mean apo E-Lp-non-B concentrations and lower apo E-LpB concentrations than did individuals carrying the epsilon3 allele. Individuals with the epsilon4 allele showed an inverse profile compared with those with the epsilon2 allele. Age, gender, the common apo E polymorphism, puberty, serum lipid concentrations, and alcohol consumption were significantly associated with total LpE, apo E-Lp-non-B, and apo E-LpB concentrations. Reference limits were established according to age, gender, and the common apo E polymorphism. CONCLUSIONS: Because measurements of LpE, apo E-Lp-non-B, and apo E-LpB concentrations may improve cardiovascular risk assessment, the proposed reference limits will aid interpretation of the results in clinical or therapeutic trials.


Assuntos
Apolipoproteínas B/química , Apolipoproteínas E/química , Lipoproteínas/química , Adolescente , Adulto , Fatores Etários , Apolipoproteínas B/sangue , Apolipoproteínas E/sangue , Apolipoproteínas E/genética , Criança , Estudos de Coortes , Feminino , Humanos , Estilo de Vida , Lipoproteínas/sangue , Masculino , Pessoa de Meia-Idade , Polimorfismo Genético , Puberdade , Valores de Referência , Fatores Sexuais
3.
Clin Chem Lab Med ; 40(7): 718-24, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12241021

RESUMO

This paper is the fourth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 2.


Assuntos
Alanina Transaminase/análise , Alanina Transaminase/normas , Catálise , Ensaios Enzimáticos Clínicos/métodos , Ensaios Enzimáticos Clínicos/normas , Humanos , Concentração de Íons de Hidrogênio , Cinética , Valores de Referência , Soluções
4.
Clin Chem Lab Med ; 40(7): 725-33, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12241022

RESUMO

This paper is the fifth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 3.


Assuntos
Aspartato Aminotransferases/análise , Aspartato Aminotransferases/normas , Catálise , Ensaios Enzimáticos Clínicos/métodos , Ensaios Enzimáticos Clínicos/normas , Humanos , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Cinética , Valores de Referência , Soluções
5.
Clin Chem Lab Med ; 40(7): 734-8, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12241023

RESUMO

This paper is the sixth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 7. Certification of Four Reference Materials for the Determination of Enzymatic Activity of Gamma-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C A document describing the determination of preliminary upper reference limits is also in preparation. The procedure described here is deduced from the previously described 30 degrees C IFCC reference method. Differences are tabulated and commented on in Appendix 1.


Assuntos
gama-Glutamiltransferase/análise , Catálise , Ensaios Enzimáticos Clínicos/métodos , Ensaios Enzimáticos Clínicos/normas , Humanos , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Cinética , Valores de Referência , Soluções , gama-Glutamiltransferase/normas
6.
Clin Chem Lab Med ; 40(6): 631-4, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12211661

RESUMO

This paper is the first in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and with the certification of reference preparations. Other parts deal with: Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic fication of Four Reference Materials for the Determination of Enzymatic Activity of y-Glutamyltransferase, Lactate Dehydrogenase, Alanine Aminotransferase and Creatine Kinase at 37 degrees C. A document describing the determination of preliminary reference values is also in preparation.


Assuntos
Enzimas/metabolismo , Catálise , Química Clínica/normas , Humanos , Concentração de Íons de Hidrogênio , Cinética , Garantia da Qualidade dos Cuidados de Saúde , Padrões de Referência , Reprodutibilidade dos Testes , Temperatura , Termodinâmica
7.
Clin Chem Lab Med ; 40(7): 739-45, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12241024

RESUMO

This paper is the seventh in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C and the certification of reference preparations. Other parts deal with: Part 1. The Concept of Reference Procedures for the Measurement of Catalytic Activity Concentrations of Enzymes; Part 2. Reference Procedure for the Measurement of Catalytic Concentration of Creatine Kinase; Part 3. Reference Procedure for the Measurement of Catalytic Concentration of Lactate Dehydrogenase; Part 4. Reference Procedure for the Measurement of Catalytic Concentration of Alanine Aminotransferase; Part 5. Reference Procedure for the Measurement of Catalytic Concentration of Aspartate Aminotransferase; Part 6. Reference Procedure for the Measurement of Catalytic Concentration of Gamma-Glutamyltransferase. A document describing the determination of preliminary reference values is also in preparation. The certification of the catalytic activity concentrations as determined by the recently elaborated IFCC primary reference methods at 37 degrees C of four enzyme preparations, namely IRMM/IFCC 452 (gamma-glutamyltransferase), IRMM/IFCC 453 (lactate dehydrogenase 1), IRMM/IFCC 454 (alanine aminotransferase) and IRMM/IFCC 455 (creatine kinase) is described. Homogeneity data were derived from previous results. Stability was assessed using recently obtained data as well as data from previous stability studies. The collaborative study for value assignment was performed under a strict quality control scheme to ensure traceability to the primary reference method. Uncertainty of the materials was assessed in compliance with the Guide to the Expression of Uncertainty in Measurement. The certified values obtained at 37 degrees C are 1.90 microkat/l +/- 0.04 microkat/l (114.1 U/l +/- 2.4 U/l), for gamma-glutamyltransferase, 8.37 microkat/l +/- 0.12 microkat/l (502 U/l +/- 7 U/l), for lactate dehydrogenase 1, 3.09 microkat/l +/- 0.07 microkat/l (186 U/l +/- 4 U/l), for alanine aminotransferase and 1.68 microkat/l +/- 0.07 microkat/l (101 U/l +/- 4 U/l), for creatine kinase. The materials are intended for internal quality control as well as for the evaluation of test systems as required by recent European Union legislation. Furthermore, the materials can be used to transfer accuracy from a reference method to a routine procedure provided the procedures exhibit the same analytical specificity and the certified materials are commutable.


Assuntos
Enzimas/normas , Guias como Assunto , Alanina Transaminase/análise , Alanina Transaminase/normas , Ensaios Enzimáticos Clínicos/métodos , Ensaios Enzimáticos Clínicos/normas , Creatina Quinase/análise , Creatina Quinase/normas , Enzimas/análise , Humanos , L-Lactato Desidrogenase/análise , L-Lactato Desidrogenase/normas , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , gama-Glutamiltransferase/análise , gama-Glutamiltransferase/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA