Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
JAMA Netw Open ; 7(3): e243786, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38530310

RESUMO

Importance: Heparin-induced thrombocytopenia (HIT) is a life-threatening condition that requires urgent diagnostic clarification. However, knowledge of the diagnostic utility of the recommended diagnostic tests is limited in clinical practice. Objective: To evaluate the current diagnostic practice for managing the suspicion of HIT. Design, Setting, and Participants: This prospective diagnostic study was conducted from January 2018 to May 2021 among consecutive patients with suspected HIT from 11 study centers in Switzerland, Germany, and the United States. Detailed clinical data and laboratory information were recorded. Platelet factor 4/heparin antibodies were quantified using an automated chemiluminescent immunoassay (CLIA). A washed-platelet heparin-induced platelet activation (HIPA) test was used as a reference standard to define HIT. Exposures: Suspicion of HIT. Main Outcomes and Measures: The primary outcome was the diagnostic accuracy of the 4Ts score, the CLIA, and the recommended algorithm serially combining both tests. Results: Of 1448 patients included between 2018 and 2021, 1318 were available for the current analysis (median [IQR] age, 67 [57-75] years; 849 [64.6%] male). HIPA was positive in 111 patients (prevalence, 8.4%). The most frequent setting was intensive care unit (487 [37.0%]) or cardiovascular surgery (434 [33.0%]). The 4Ts score was low risk in 625 patients (46.8%). By 2 × 2 table, the numbers of patients with false-negative results were 10 (9.0%; 4Ts score), 5 (4.5%; CLIA), and 15 (13.5%; recommended diagnostic algorithm). The numbers of patients with false-positive results were 592 (49.0%; 4Ts score), 73 (6.0%; CLIA), and 50 (4.1%; recommended diagnostic algorithm), respectively. Conclusions and Relevance: In this diagnostic study of patients suspected of having HIT, when the recommended diagnostic algorithm was used in clinical practice, antibody testing was required in half the patients. A substantial number of patients were, however, still misclassified, which could lead to delayed diagnosis or overtreatment. Development of improved diagnostic algorithms for HIT diagnosis should be pursued.


Assuntos
Trombocitopenia , Humanos , Masculino , Idoso , Feminino , Estudos Prospectivos , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico , Heparina/efeitos adversos , Algoritmos , Alemanha
2.
Blood Adv ; 8(11): 2825-2834, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38588487

RESUMO

ABSTRACT: New analytical techniques can assess hundreds of proteins simultaneously with high sensitivity, facilitating the observation of their complex interplay and role in disease mechanisms. We hypothesized that proteomic profiling targeting proteins involved in thrombus formation, inflammation, and the immune response would identify potentially new biomarkers for heparin-induced thrombocytopenia (HIT). Four existing panels of the Olink proximity extension assay covering 356 proteins involved in thrombus formation, inflammation, and immune response were applied to randomly selected patients with suspected HIT (confirmed HIT, n = 32; HIT ruled out, n = 38; and positive heparin/platelet factor 4 [H/PF4] antibodies, n = 28). The relative difference in protein concentration was analyzed using a linear regression model adjusted for sex and age. To confirm the test results, soluble P-selectin was determined using enzyme-linked immunosorbent assay (ELISA) in above mentioned patients and an additional second data set (n = 49). HIT was defined as a positive heparin-induced platelet activation assay (washed platelet assay). Among 98 patients of the primary data set, the median 4Ts score was 5 in patients with HIT, 4 in patients with positive H/PF4 antibodies, and 3 in patients without HIT. The median optical density of a polyspecific H/PF4 ELISA were 3.0, 0.9, and 0.3. Soluble P-selectin remained statistically significant after multiple test adjustments. The area under the receiver operating characteristic curve was 0.81 for Olink and 0.8 for ELISA. Future studies shall assess the diagnostic and prognostic value of soluble P-selectin in the management of HIT.


Assuntos
Biomarcadores , Heparina , Proteômica , Trombocitopenia , Humanos , Heparina/efeitos adversos , Feminino , Proteômica/métodos , Masculino , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico , Trombocitopenia/sangue , Pessoa de Meia-Idade , Idoso , Selectina-P/sangue , Fator Plaquetário 4 , Adulto , Ativação Plaquetária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA