Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Heart Lung Circ ; 31(8): 1102-1109, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35501246

RESUMO

BACKGROUND: Non-invasive computed tomography (CT)-derived fractional flow reserve (FFRCT) is computed from standard coronary CT angiography (CTA) datasets and provides accurate vessel-specific ischaemia assessment of coronary artery disease (CAD). To date, the technique and its diagnostic performance has not been verified in the Australian clinical context. The aim of this study was to describe and compare the diagnostic performance of FFRCT and CTA for the detection of vessel-specific ischaemia as determined by invasive fractional flow reserve (FFR) in the Australian patient population. METHODS: One-hundred-and-nine patients (219 vessels) referred for clinically mandated invasive angiography were retrospectively assessed. Each patient underwent research mandated CTA and FFRCT within 3 months of invasive angiography and invasive FFR assessment. Independent core laboratory assessments were made to determine visual CTA stenosis, FFRCT and invasive FFR values. FFRCT values were matched with the corresponding invasive FFR measurement taken at the given wire position. Visual CTA stenosis ≥50%, FFRCT values ≤0.8 and invasive FFR values ≤0.8 were considered significant for ischaemia. RESULTS: Per vessel accuracy, sensitivity, specificity, positive predictive value and negative predictive value of FFRCT were 80.4%, 80.0%, 80.6%, 64.9% and 90.0% respectively. Corresponding values for CTA were 75.1%, 87.1%, 69.2%, 58.1% and 91.7% respectively. In receiver operating characteristic curve analysis, FFRCT demonstrated superior area under the curve (AUC) compared with CTA in both per vessel (0.87 vs 0.77, p=0.004) and per patient analysis (0.86 vs 0.74, p=0.011). Per vessel AUC of combined CTA and FFRCT was superior to CTA alone (0.89 vs 0.77, p<0.0001). CONCLUSION: In this cohort of Australian patients, the diagnostic performance of FFRCT was found to be comparable to existing international literature, with demonstrated improvement in performance compared with CTA alone for the detection of vessel-specific ischaemia.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Austrália , Constrição Patológica , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X/métodos
2.
Radiology ; 292(2): 343-351, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31184558

RESUMO

Background Coronary CT angiography with noninvasive fractional flow reserve (FFR) predicts lesion-specific ischemia when compared with invasive FFR. The longer term prognostic value of CT-derived FFR (FFRCT) is unknown. Purpose To determine the prognostic value of FFRCT when compared with coronary CT angiography and describe the relationship of the numeric value of FFRCT with outcomes. Materials and Methods This prospective subanalysis of the NXT study (Clinicaltrials.gov: NCT01757678) evaluated participants suspected of having stable coronary artery disease who were referred for invasive angiography and who underwent FFR, coronary CT angiography, and FFRCT. The incidence of the composite primary end point of death, myocardial infarction, and any revascularization and the composite secondary end point of major adverse cardiac events (MACE: cardiac death, myocardial infarction, unplanned revascularization) were compared for an FFRCT of 0.8 or less versus stenosis of 50% or greater on coronary CT angiograms, with treating physicians blinded to the FFRCT result. Results Long-term outcomes were obtained in 206 individuals (age, 64 years ± 9.5), including 64% men. At median follow-up of 4.7 years, there were no cardiac deaths or myocardial infarctions in participants with normal FFRCT. The incidence of the primary end point was more frequent in participants with positive FFRCT compared with clinically significant stenosis at coronary CT angiography (73.4% [80 of 109] vs 48.7% [91 of 187], respectively; P < .001), with the majority of outcomes being planned revascularization. Corresponding hazard ratios (HRs) were 9.2 (95% confidence interval [CI]: 5.1, 17; P < .001) for FFRCT and 5.9 (95% CI: 1.5, 24; P = .01) for coronary CT angiography. FFRCT was a superior predictor compared with coronary CT angiography for primary end point (C-index FFRCT, 0.76 vs coronary CT angiography, 0.54; P < .001) and MACE (FFRCT, 0.71 vs coronary CT angiography, 0.52; P = .001). Frequency of MACE was higher in participants with positive FFRCT compared with coronary CT angiography (15.6% [17 of 109] vs 10.2% [19 of 187], respectively; P = .02), driven by unplanned revascularization. MACE HR was 5.5 (95% CI: 1.6, 19; P = .006) for FFRCT and 2.0 (95% CI: 0.3, 14; P = .46) for coronary CT angiography. Each 0.05-unit FFRCT reduction was independently associated with greater incidence of primary end point (HR, 1.7; 95% CI: 1.4, 1.9; P < .001) and MACE (HR, 1.4; 95% CI: 1.1, 1.8; P < .001). Conclusion In stable patients referred for invasive angiography, a CT-derived fractional flow reserve (FFRCT) value of 0.8 or less was a predictor of long-term outcomes driven by planned and unplanned revascularization and was superior to clinically significant stenosis on coronary CT angiograms. Additionally, the numeric value of FFRCT was an independent predictor of outcomes. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Dennie and Rubens in this issue.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Medição de Risco , Índice de Gravidade de Doença
3.
Radiology ; 279(1): 75-83, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26444662

RESUMO

PURPOSE: To compare the diagnostic performance of 320-detector row computed tomography (CT) coronary angiography-derived computed fractional flow reserve (FFR; FFRCT), transluminal attenuation gradient (TAG; TAG320), and CT coronary angiography alone to diagnose hemodynamically significant stenosis as determined by invasive FFR. MATERIALS AND METHODS: This substudy of the prospective NXT study (no. NCT01757678) was approved by each participating institution's review board, and informed consent was obtained from all participants. Fifty-one consecutive patients who underwent 320-detector row CT coronary angiographic examination and invasive coronary angiography with FFR measurement were included. Independent core laboratories determined coronary artery disease severity by using CT coronary angiography, TAG320, FFRCT, and FFR. TAG320 is defined as the linear regression coefficient between luminal attenuation and axial distance from the coronary ostium. FFRCT was computed from CT coronary angiography data by using computational fluid dynamics technology. Diagnostic performance was evaluated and compared on a per-vessel basis by the area under the receiver operating characteristic (ROC) curve (AUC). RESULTS: Among 82 vessels, 24 lesions (29%) had ischemia by FFR (FFR ≤ 0.80). FFRCT exhibited a stronger correlation with invasive FFR compared with TAG320 (Spearman ρ, 0.78 vs 0.47, respectively). Overall per-vessel accuracy, sensitivity, specificity, and positive and negative predictive values for TAG320 (<15.37) were 78%, 58%, 86%, 64%, and 83%, respectively; and those of FFRCT were 83%, 92%, 79%, 65%, and 96%, respectively. ROC curve analysis showed a significantly larger AUC for FFRCT (0.93) compared with that for TAG320 (0.72; P = .003) and CT coronary angiography alone (0.68; P = .008). CONCLUSION: FFRCT computed from 320-detector row CT coronary angiography provides better diagnostic performance for the diagnosis of hemodynamically significant coronary stenoses compared with CT coronary angiography and TAG320.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia Computadorizada Multidetectores/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Feminino , Humanos , Iohexol , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
4.
Radiology ; 276(1): 91-101, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25710278

RESUMO

PURPOSE: To identify computed tomographic (CT) coronary indexes independently associated with a fractional flow reserve (FFR) of 0.8 or less, to derive a score that combines CT indexes most predictive of an FFR of 0.8 or less, and to evaluate the diagnostic accuracy of the score in predicting an FFR of 0.8 or less. MATERIALS AND METHODS: This retrospective study had institutional review board approval and waiver of the need to obtain informed consent. Consecutive patients who underwent CT coronary angiography and FFR assessment with one or more discrete lesion(s) of intermediate (30%-70%) severity at CT were included. Quantitative CT measurements were performed by using dedicated software. The CT indexes evaluated included the following: plaque burden, minimal luminal area and diameter, stenosis diameter, area of stenosis, lesion length, remodeling index, plaque morphology, calcification severity, and the Alberta Provincial Project for Outcome Assessment in Coronary Heart Disease (APPROACH) score, which approximates the size of the myocardium subtended by a lesion. By using covariates independently associated with an FFR of 0.8 or less, a score was determined on the basis of modified Akaike information criteria, and the C statistics of individual and combined indexes were compared. RESULTS: Eighty-five patients (mean age, 64.2 years; range, 48-88 years; 65.9% men; 124 lesions; 38 lesions with an FFR ≤ 0.8) were included. Area of stenosis, lesion length, and APPROACH score were the strongest predictors of an FFR of 0.8 or less and were used to derive the ASLA score. The optimism-adjusted Harrell C statistic for the combined score was 0.82, which was superior to that for area of stenosis (0.74), lesion length (0.75), and the APPROACH score (0.71) (P < .001 for trend). The corresponding incremental discrimination improvement indexes were 0.17, 0.11, and 0.19, respectively (P < .001 for all), suggesting that the score improves reclassification compared with any one angiographic index. The average time required for score derivation was 102.6 seconds. CONCLUSION: The ASLA score, which accounts for CT-derived area of stenosis, lesion length, and APPROACH score, may conveniently improve the prediction, beyond individual indexes, of functionally significant intermediate coronary lesions.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença
5.
Radiology ; 272(3): 674-82, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24738614

RESUMO

PURPOSE: To assess the long-term outcome and hospital readmission rate associated with a computed tomographic (CT) angiography-guided strategy used to examine patients who present to the emergency department (ED) with symptoms of possible acute coronary syndrome (ACS). MATERIALS AND METHODS: The study was approved by the institutional review board, and all patients provided written informed consent. A total of 585 consecutive patients (mean age, 58 years ± 11 [standard deviation]; 58% were male) with ischemic-type chest pain and low to intermediate risk for ACS were evaluated prospectively. Patients underwent coronary CT angiography after single or serial troponin I (TnI) measurement, depending on time of presentation to the ED. Subsequent care was determined with CT angiography findings: Patients without plaque and patients with nonobstructive plaque and at most mild to moderate stenosis (<40% luminal narrowing) were discharged without further investigation. Patients with moderate stenosis (40%-70% narrowing) were discharged and referred for outpatient stress echocardiography. Patients with severe stenosis (>70% narrowing) were admitted. Discharged patients were contacted and their medical records were reviewed to determine rates of death, ACS, revascularization, and hospital admission. By using binomial distribution, Clopper-Pearson confidence intervals (CIs) were calculated for outcome data. RESULTS: Coronary CT angiography findings were as follows: A total of 196 patients (34%) had no coronary plaque or stenosis, 288 (49%) had nonobstructive plaque, 22 (4%) had moderate stenosis, and 79 (13%) had severe stenosis. At median 47.4-month follow-up (range, 24-57 months) of the 506 discharged patients, five (1%; 95% CI: 0.4%, 2.3%) had been readmitted for chest pain; there were no instances of coronary revascularization, ACS, or death (0% for all; 95% CI: 0%, 0.7%). Follow-up was 100% complete. CONCLUSION: Use of a CT angiography-guided strategy to investigate patients with low to intermediate risk of ACS who present to the ED with chest pain is safe at long-term follow-up, including patients discharged after single TnI measurement.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Síndrome Coronariana Aguda/terapia , Estudos de Coortes , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Prevalência , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Resultado do Tratamento , Vitória/epidemiologia
6.
Eur Radiol ; 24(3): 738-47, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24217643

RESUMO

OBJECTIVES: To determine the accuracy of 320-row multidetector coronary computed tomography angiography (M320-CCTA) to detect functional stenoses using fractional flow reserve (FFR) as the reference standard and to predict revascularisation in stable coronary artery disease. METHODS: One hundred and fifteen patients (230 vessels) underwent M320-CCTA and FFR assessment and were followed for 18 months. Diameter stenosis on invasive angiography (ICA) and M320-CCTA were assessed by consensus by two observers and significant stenosis was defined as ≥50%. FFR ≤0.8 indicated functionally significant stenoses. RESULTS: M320-CCTA had 94% sensitivity and 94% negative predictive value (NPV) for FFR ≤0.8. Overall accuracy was 70%, specificity 54% and positive predictive value 65%. On receiver operating characteristic (ROC) curve analysis, the area under the curve (AUC) for CCTA to predict FFR ≤0.8 was 0.74 which was comparable with ICA. The absence of a significant stenosis on M320-CCTA was associated with a 6% revascularisation rate. M320-CCTA predicted revascularisation with an AUC of 0.71 which was comparable with ICA. CONCLUSIONS: M320-CCTA has excellent sensitivity and NPV for functional stenoses and therefore may act as an effective gatekeeper to defer ICA and revascularisation. Like ICA, M320-CCTA lacks specificity for functional stenoses and only has moderate accuracy to predict the need for revascularisation. KEY POINTS: • Important information about the heart is provided by 320-row multidetector CT coronary angiography (M320-CCTA). • M320-CCTA accurately detects and excludes functional stenoses determined by fractional flow reserve (FFR). • Non-significant stenoses on M320-CCTA associated with fewer cardiac events and less revascularisation. • M320-CCTA may act as a gatekeeper for invasive angiography and inappropriate revascularisation. • Like ICA, M320-CCTA only has moderate accuracy to predict vessels requiring revascularisation.


Assuntos
Angiografia Coronária/normas , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Tomografia Computadorizada Multidetectores/normas , Idoso , Angina Pectoris/diagnóstico por imagem , Área Sob a Curva , Angiografia Coronária/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
7.
Pacing Clin Electrophysiol ; 37(5): 537-45, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24883448

RESUMO

INTRODUCTION: We aimed to assess the utility of cardiac computed tomography (CT) in the evaluation of right atrial (RA) and right ventricular (RV) pacemaker and implantable cardiac defibrillator lead perforation. METHODS: Images from a 320-slice electrocardiogram-gated cardiac CT scanner were retrospectively independently analyzed by two reviewers for lead position, pericardial effusion, and perforation.Perforation results were correlated with pacing sensing, impedance, and threshold measurements. RESULTS: A total of 52 patients had RV leads and 35 had RA leads. Five of 17 RV apical, one of 35 RV nonapical, and none of the 35 RA leads perforated through the myocardium on CT imaging criteria. Two "clinically" perforated leads (that had protruded 5 mm and 15 mm from the outer edge of the myocardium)had pericardial effusions and changes in pacing parameters, and required RV lead repositioning. In contrast,there were four apparent "radiologic" perforations (that had protruded only an average 1.5±0.5 mm from the outer edge of the myocardium) that did not require repositioning. These had the radiologic appearance of perforation on cardiac CT; however, they were not associated with pericardial effusions or significant changes in RV pacing lead sensing, impedance, and threshold measurements. CONCLUSIONS: Cardiac CT scanning with multiplanar reformatting is useful for documenting lead position and assessing for possible cardiac perforation. The clinical significance and natural history of leads with only the appearance of perforation on cardiac CT is uncertain.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Traumatismos Cardíacos/etiologia , Marca-Passo Artificial/efeitos adversos , Tomografia Computadorizada por Raios X , Ferimentos Penetrantes/etiologia , Idoso , Feminino , Traumatismos Cardíacos/diagnóstico por imagem , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Ferimentos Penetrantes/diagnóstico por imagem
8.
Pacing Clin Electrophysiol ; 37(6): 717-23, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24372320

RESUMO

INTRODUCTION: There have been rare case reports of damage to adjacent coronary arteries by screw-in pacemaker and implantable cardioverter-defibrillator (ICD) leads. Our aim was to assess the proximity of pacemaker and ICD leads to the major coronary anatomy using cardiac computed tomography (CT). METHODS: Cardiac CT images were retrospectively analyzed to assess the spatial relationship of device lead tips to the major coronary anatomy. RESULTS: Fifty-two right ventricular (RV) leads (17 apical, 35 nonapical) and 35 right atrial (RA) leads were assessed. Leads on the RV antero-septal junction (20 of 52) were close (median 4.7 mm) to, and orientated toward, the left anterior descending (LAD) coronary artery. RA leads in the anterior (26 of 35) and lateral (seven of 35) walls of the RA appendage were not close to (16.9 ± 7.7 mm and 18.9 ± 12.4 mm, respectively) and directed away from the right coronary artery. However, an RA lead adjacent to the superior border of the tricuspid valve was 4.3 mm from the right coronary artery and an RA lead on the medial wall of the RA appendage was 1.6 mm away from the aorta. An RV pacemaker lead in the lateral wall of the RV inlet was 3.4 mm from the right coronary artery. CONCLUSIONS: In our cohort, a majority of RV leads were on the antero-septal junction and close to the overlying LAD coronary artery. RA leads adjacent to the tricuspid valve or on the medial RA appendage were in close proximity to the right coronary artery and aorta, respectively.


Assuntos
Angiografia Coronária/métodos , Vasos Coronários/cirurgia , Desfibriladores Implantáveis , Implantação de Prótese/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Marca-Passo Artificial , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 37(4): 495-504, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24215477

RESUMO

INTRODUCTION: It is hypothesized that pacing the right ventricular (RV) septum is associated with less deleterious outcomes than RV apical pacing. Our aim was to validate fluoroscopic and electrocardiography (ECG) criteria for describing pacemaker and implantable cardioverter defibrillator RV "septal" lead position against the proposed gold standard: cardiac computed tomography (CT). METHODS: Using the conventional fluoroscopic criteria, we intended to place RV nonapical leads on the interventricular septum. Lead positions were later retrospectively analyzed with CT and correlated with ECGs and fluoroscopic projections: posterior-anterior, 40° left anterior oblique (LAO), 40° right anterior oblique (RAO), and left lateral. RESULTS: Only 21% (nine of 35) of presumed "septal" RV nonapical leads using the conventional fluoroscopic criteria were on the true septum. A schema developed to define septal position in the RAO fluoroscopic view had high agreement with CT images. ECG criteria had only fair to moderate agreement with CT. The paced QRS duration was significantly longer (P < 0.001) with RV apical pacing (176 ± 10.7 ms), compared to RV nonapical pacing (144.5 ± 14.3 ms). CONCLUSION: Using the conventional fluoroscopic criteria, only a minority of RV leads were implanted on the true RV septum. Instead, aiming for the middle of the cardiac silhouette in the RAO fluoroscopic view, confirming rightward orientation in the LAO view, and having a paced QRS duration <140 ms may allow the implanting cardiologist a simple, more accurate method to achieve true RV septal lead positioning.


Assuntos
Eletrocardiografia/métodos , Eletrodos Implantados , Fluoroscopia/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Marca-Passo Artificial , Tomografia Computadorizada por Raios X/métodos , Austrália , Septos Cardíacos/diagnóstico por imagem , Humanos , Implantação de Prótese/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Radiology ; 267(1): 11-25, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23525715

RESUMO

Multidetector computed tomography (CT) has an established role in the evaluation of selected patients suspected of having coronary disease; however, in addition to coronary assessment, multidetector CT can be used to evaluate numerous noncoronary structures in the same examination. In particular, the use of multidetector CT to provide pulmonary and cardiac venous anatomic information prior to electrophysiology procedures is well established, and its important role in the periprocedural evaluation of patients undergoing percutaneous procedures, such as transcatheter aortic valve replacement and left atrial appendage device occlusion, is being increasingly recognized. Such advances have resulted in multidetector CT being increasingly used as a complementary imaging technique to echocardiography and magnetic resonance imaging for the comprehensive evaluation of cardiac structure and function in particular clinical situations. This review provides an overview of the noncoronary cardiac structures that can be evaluated with multidetector CT, and outlines the established appropriate clinical uses of multidetector CT in the assessment of structural heart disease, as well as evolving periprocedural clinical applications.


Assuntos
Cardiopatias/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Meios de Contraste , Ecocardiografia , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Interpretação de Imagem Radiográfica Assistida por Computador
11.
Eur Radiol ; 23(7): 1812-21, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23430194

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of combined 320-detector row computed tomography coronary angiography (CTA) and adenosine stress CT myocardial perfusion imaging (CTP) in detecting perfusion abnormalities caused by obstructive coronary artery disease (CAD). METHODS: Twenty patients with suspected CAD who underwent initial investigation with single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) were recruited and underwent prospectively-gated 320-detector CTA/CTP and invasive angiography. Two blinded cardiologists evaluated invasive angiography images quantitatively (QCA). A blinded nuclear physician analysed SPECT-MPI images for fixed and reversible perfusion defects. Two blinded cardiologists assessed CTA/CTP studies qualitatively. Vessels/territories with both >50 % stenosis on QCA and corresponding perfusion defect on SPECT-MPI were defined as ischaemic and formed the reference standard. RESULTS: All patients completed the CTA/CTP protocol with diagnostic image quality. Of 60 vessels/territories, 17 (28 %) were ischaemic according to QCA/SPECT-MPI criteria. Sensitivity, specificity, PPV, NPV and area under the ROC curve for CTA/CTP was 94 %, 98 %, 94 %, 98 % and 0.96 (P < 0.001) on a per-vessel/territory basis. Mean CTA/CTP radiation dose was 9.2 ± 7.4 mSv compared with 13.2 ± 2.2 mSv for SPECT-MPI (P < 0.001). CONCLUSIONS: Combined 320-detector CTA/CTP is accurate in identifying obstructive CAD causing perfusion abnormalities compared with combined QCA/SPECT-MPI, achieved with lower radiation dose than SPECT-MPI. KEY POINTS: • Advances in CT technology provides comprehensive anatomical and functional cardiac information. • Combined 320-detector CTA/adenosine-stress CTP is feasible with excellent image quality. • Combined CTA/CTP is accurate in identifying myocardial ischaemia compared with QCA/SPECT-MPI. • Combined CTA/CTP results in lower patient radiation exposure than SPECT-MPI. • CTA/CTP may become an established imaging technique for suspected CAD.


Assuntos
Adenosina , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/patologia , Feminino , Taxa de Filtração Glomerular , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Perfusão , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/métodos
12.
Eur Heart J ; 33(1): 67-77, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21810860

RESUMO

AIMS: Adenosine stress computed tomography myocardial perfusion imaging (CTP) is an emerging non-invasive method for detecting myocardial ischaemia. Its value when compared with fractional flow reserve (FFR), a highly accurate index of ischaemia, is unknown. Our aim was to determine the diagnostic accuracy of CTP and its incremental value when used with computed tomography coronary angiography (CTA) for detecting ischaemia compared with FFR. METHODS AND RESULTS: Forty-two patients (126 vessel territories), who had at least one ≥50% angiographic stenosis on invasive angiography considered for non-urgent revascularization, were included and underwent FFR and CT assessment, including CTP, delayed contrast enhancement scan and CTA all acquired using 320-detector row CT, and prospective ECG gating. Fractional flow reserve was determined in 86 territories subtended by vessels with ≥50% stenosis upon visual assessment. Fractional flow reserve ≤0.8 was considered to indicate significant ischaemia. Computed tomography myocardial perfusion imaging correctly identified 31/41 (76%) ischaemic territories and 38/45 (84%) non-ischaemic territories. Per-vessel territory sensitivity, specificity, positive, and negative predictive values of CTP were 76, 84, 82, and 79%, respectively. The combination of a ≥50% stenosis on CTA and perfusion defect on CTP was 98% specific for ischaemia, while the presence of <50% stenosis on CTA and normal perfusion on CTP was 100% specific for exclusion of ischaemia. Mean radiation for CTP and combined CT was 5.3 and 11.3 mSv, respectively. CONCLUSION: Computed tomography myocardial perfusion imaging is moderately accurate in identifying perfusion defects associated with ischaemia as assessed by FFR in patients considered for revascularization. In territories, where CTA and CTP are concordant, CTA/CTP is highly accurate in the detection and exclusion of ischaemia. This is achievable with acceptable radiation exposure using 320-detector row CT and prospective ECG gating.


Assuntos
Reserva Fracionada de Fluxo Miocárdico/fisiologia , Isquemia Miocárdica/diagnóstico , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos , Adenosina , Idoso , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Revascularização Miocárdica/métodos , Variações Dependentes do Observador , Estudos Prospectivos , Sensibilidade e Especificidade , Vasodilatadores
13.
Radiology ; 260(2): 381-9, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21673228

RESUMO

PURPOSE: To assess the impact on length of stay and rate of major adverse cardiovascular events of a cardiac computed tomographic (CT) angiography-guided algorithm to examine patients who present to the emergency department (ED) with low- to intermediate-risk chest pain. MATERIALS AND METHODS: The study was approved by the institutional review board, and all patients gave written informed consent. Two hundred three consecutive patients (mean age, 55 years ± 11 [standard deviation]; 123 men) with low- to intermediate-risk ischemic-type chest pain were prospectively enrolled. Patients underwent initial cardiac CT angiography with subsequent treatment determined by reference to findings at cardiac CT angiography; patients without overt plaque were immediately discharged from the hospital, patients with nonobstructive plaque and mild-to-moderate stenoses were discharged after a negative 6-hour troponin level, and patients with severe stenoses were admitted to the hospital. Discharged patients were followed up for a mean of 14.2 months. Additionally, length of stay and safety outcomes among these patients were compared with those in 102 consecutive patients with low- to intermediate-risk chest pain who presented to the ED and underwent a standard of care (SOC) work-up without cardiac CT angiography. One-way analysis of variance with Bonferroni correction was used to compare length of stay between groups. RESULTS: Cardiac CT angiography findings in the 203 patients who underwent cardiac CT angiography were as follows: Sixty-five (32%) patients had no plaque, 107 (53%) had nonobstructive plaque, and 31 (15%) had severe stenoses. At follow-up, there were no deaths or cases of acute coronary syndrome (cardiac CT angiography, 0%, 95% confidence interval [CI]: 0%, 1.85%; SOC, 0%, 95% CI: 0%, 3.63%), and the rate of readmission to the hospital because of chest pain was higher with the SOC approach (9% vs 1%, P = .01). Mean ED length of stay was lower with cardiac CT angiography (6.62 hours ± 0.38 after a single troponin level and 9.15 hours ± 0.30 after serial troponin levels) than with the SOC approach (11.62 hours ± 0.47, P < .001). CONCLUSION: Tailoring troponin measurement to cardiac CT angiography findings is safe and allows early discharge of patients with low- to intermediate-risk chest pain, resulting in reduced length of stay.


Assuntos
Dor no Peito/diagnóstico por imagem , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X , Troponina/sangue , Doença Aguda , Algoritmos , Análise de Variância , Biomarcadores/sangue , Dor no Peito/terapia , Distribuição de Qui-Quadrado , Serviço Hospitalar de Emergência , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
14.
AJR Am J Roentgenol ; 196(6): W729-35, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21606261

RESUMO

OBJECTIVE: High heart rate may negatively influence the image quality of cardiac CT. The technical advances of 320-MDCT may overcome issues with poor image quality associated with high heart rate. This study aimed to evaluate the coronary image quality of 320-MDCT in patients with heart rates above 65 beats/min. MATERIALS AND METHODS: Patients who presented for cardiac CT were divided into two groups according to heart rate, either greater than 65 beats/min or less than or equal to 65 beats/min. Two radiologists were blinded to the patient groups and evaluated images of 15 coronary artery segments per patient using 320-MDCT with consensus agreement. The image quality was scored subjectively as 1 or 2 (diagnostic quality) or 3 (poor quality and nondiagnostic). RESULTS: There were no statistically significant differences between the two groups in terms of age, sex, and body mass index (p > 0.05). The median heart rate was 70 beats/min (range, 67-110 beats/min) for the group with heart rate greater than 65 beats/min and 60 beats/min (range, 48-65 beats/min) for the group with heart rate less than or equal to 65 beats/min (p < 0.001). In patients with heart rates greater than 65 beats/min, diagnostic quality images (scores of 1 or 2) were obtained in 95.6% of the analyzed segments, compared with 96.9% in the group with heart rate less than or equal to 65 beats/min (p = 0.7). CONCLUSION: Our initial evaluation suggests that coronary artery images of diagnostic quality can be obtained using 320-MDCT in most patients with heart rates greater than 65 beats/min, in percentages similar to those for patients with heart rates less than or equal to 65 beats/min. This finding may be the result of the inherent image acquisition and reconstruction technique of 320-MDCT.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Frequência Cardíaca/fisiologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Distribuição de Qui-Quadrado , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X/normas
15.
J Cardiovasc Comput Tomogr ; 14(4): 356-362, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31787591

RESUMO

BACKGROUND: Onsite workstation-based CT-derived Fractional-Flow-Reserve (CT-FFR) is accurate in assessing hemodynamic-significance of coronary stenoses. We aim to describe the influence of operator expertise and luminal-segmentation technique on the diagnostic performance, precision and reproducibility of CT-FFR in identifying hemodynamically-significant stenosis (FFR≤0.8). METHODS: Forty-eight consecutive stable-patients (86 vessels) with suspected CAD underwent research indicated invasive-FFR and 320-detector CT-coronary-angiography (CTA). CT-FFR was derived using reduced-order model on standard desktop-computer. Semi-automated coronary luminal segmentation was performed using focused-technique with manual adjustments at regions of stenosis and calcification or comprehensive-technique with manual adjustments along the entire course of the vessel. CT-FFR analysis was performed using 3 blinded operators; core-laboratory engineer using focused-technique and radiographer and cardiologist using the comprehensive-technique. Diagnostic performance was assessed by area under receiver-operating-curve (AUC). Precision with invasive FFR was determined by Bland-Altman analysis, and reproducibility by intraclass-correlation-coefficient (ICC). RESULTS: Diagnostic performance was comparable among operators (Engineer: AUC = 0.88, Radiographer 0.84; Cardiologist 0.87; P = 0.59). Coronary luminal-segmentation time was shortest using focused technique (engineer 6:17 ± 2.43 min), compared with comprehensive technique (cardiologist 14.83 ± 7.09, radiographer 24.74 ± 12.65; P < 0.001). Use of focused technique was associated with widest limits of agreement (LOA) with FFR and moderate intra-operator reproducibility (engineer LOA -0.20-0.33; ICC 0.66), when compared with the comprehensive technique which demonstrated narrower LOA and excellent reproducibility [radiographer (LOA -0.17-0.20, ICC = 0.91) and cardiologist (LOA-0.15-0.23, ICC = -0.93)] CONCLUSION: A workstation-based CT-FFR technique was reproducible with high and comparable diagnostic performance among operators with different expertise. A comprehensive luminal segmentation technique was the most time-consuming and associated with the highest reproducibility and precision with FFR.


Assuntos
Cardiologistas , Competência Clínica , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Tomografia Computadorizada Multidetectores , Interpretação de Imagem Radiográfica Assistida por Computador , Radiologistas , Idoso , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
16.
Arterioscler Thromb Vasc Biol ; 28(3): 568-74, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18174458

RESUMO

OBJECTIVE: To assess the association between cardiovascular risk factors and extent of noncalcified- (NCAP), mixed- (MCAP), and calcified coronary atherosclerotic plaque (CAP). METHODS AND RESULTS: In this cross-sectional study, we included consecutive subjects who presented with chest pain but had no history of coronary artery disease (CAD) and did not develop acute coronary syndrome. Contrast-enhanced 64-slice coronary MDCT was performed to determine the presence of NCAP, MCAP, and CAP for each coronary segment. Among 195 patients (91 women, mean age: 54.6+/-12.0) exclusively NCAP was detected in 11 patients (5.6%). The extent of NCAP decreased and the extent of MCAP and CAP increased with age (P=0.06, P=0.02, and P=0.13, respectively). Hyperlipidemia and family history of CAD were associated with the extent of NCAP after adjusting for other risk factors (P=0.02 and P=0.04, respectively) or for the extent of MCAP and CAP (P=0.02 and P=0.05, respectively). CONCLUSIONS: Our data suggest that only a small proportion of individuals have exclusively NCAP and indicate that the relation of NCAP and CAP changes with age. Among individual risk factors, hyperlipidemia and family history of CAD may be associated with the extent of NCAP. Larger observational trials are necessary to confirm our findings.


Assuntos
Aterosclerose/patologia , Doença da Artéria Coronariana/diagnóstico , Tomografia Computadorizada Espiral/métodos , Adulto , Distribuição por Idade , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Meios de Contraste , Doença da Artéria Coronariana/epidemiologia , Estudos Transversais , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Probabilidade , Medição de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Análise de Sobrevida
17.
AJR Am J Roentgenol ; 193(6): 1514-21, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19933642

RESUMO

OBJECTIVE: Noninvasive coronary angiography has generally been contraindicated in patients with atrial fibrillation because of the difficulty in synchronizing an irregular heartbeat with table gantry movement. The objective of this study was to evaluate and compare the quality of 320-MDCT images obtained in patients with atrial fibrillation and in a control group of patients in sinus rhythm. MATERIALS AND METHODS: Two reviewers were blinded to the patient groups and evaluated images of 15 coronary artery segments for each patient using 320-MDCT. The images were printed on glossy paper and scored subjectively as 1 or 2, meaning of diagnostic quality, or 3, meaning poor quality. RESULTS: No statistical difference between the groups was noted in patient age: The mean age of the patients with atrial fibrillation was 67 years (age range, 52-82 years) and that of the patients in sinus rhythm was 59 years (36-86 years) (p = 0.3). Scores of 1 and 2 (diagnostic quality) were assigned to 100% in sinus rhythm and 96% in atrial fibrillation (p < 0.05). Scores of 3 were seen only in the atrial fibrillation group (7/175, 4%). Segment 15, the distal circumflex artery, was the segment that was most frequently assigned a score of 3 (2/7, 28.6%). A discrepancy in the two reviewers' scores was seen in 25 segments (7%), requiring joint consensus. The segments that most frequently required consensus reading were segments 12 and 15. The overall mean image quality score for all three coronary arteries in atrial fibrillation was 1.25 +/- 0.47 (SD) and 1.08 +/- 0.26 in sinus rhythm (p < 0.001). The median effective dose was 19.28 and 13.55 mSv in the atrial fibrillation and sinus rhythm groups, respectively. CONCLUSION: The analysis of our initial experience shows that imaging in patients with atrial fibrillation is possible using 320-MDCT, with images of most segments obtained being of diagnostic quality. Segment 15 was the most difficult to see on 320-MDCT because of the small caliber of the vessel; poor visualization of that segment mostly occurred in the setting of a dominant right coronary arterial system.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Angiografia Coronária/métodos , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
18.
Int J Cardiovasc Imaging ; 35(11): 2103-2112, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31273632

RESUMO

Computed tomography derived fractional flow reserve (FFRCT) and computed tomography stress myocardial perfusion imaging (CTP) are techniques to assess haemodynamic significance of coronary stenosis. To compare the diagnostic performance of FFRCT and static rest/stress CTP in detecting fractional flow reserve (FFR) defined haemodynamically-significant stenosis (FFR ≤ 0.8). Fifty-one patients (96 vessels) with suspected coronary artery disease from a single institution planned for elective invasive-angiography prospectively underwent research indicated 320-detector-CT-coronary-angiography (CTA) and adenosine-stress CTP and invasive FFR. Analyses were performed in separate core-laboratories for FFRCT and CTP blinded to FFR results. Myocardial perfusion was assessed visually and semi-quantitatively by transmural perfusion ratio (TPR). Invasive FFR ≤ 0.8 was present in 33% of vessels and 49% of patients. FFRCT, visual CTP and TPR analysis was feasible in 96%, 92% and 92% of patients respectively. Overall per-vessel sensitivity, specificity and diagnostic accuracy for FFRCT were 81%, 85%, 84%, for visual CTP were 50%, 89%, 75% and for TPR were 69%, 48%, 56% respectively. Receiver-operating-characteristics curve analysis demonstrated larger per vessel area-under-curve (AUC) for FFRCT (0.89) compared with visual CTP (0.70; p < 0.001), TPR (0.58; p < 0.001) and CTA (0.70; p = 0.0007); AUC for CTA + FFRCT (0.91) was higher than CTA + visual CTP (0.77, p = 0.008) and CTA + TPR (0.74, p < 0.001). Per-patient AUC for FFRCT (0.90) was higher than visual CTP (0.69; p = 0.0016), TPR (0.56; p < 0.0001) and CTA (0.68; p = 0.001). Based on this selected cohort of patients FFRCT is superior to visually and semi-quantitatively assessed static rest/stress CTP in detecting haemodynamically-significant coronary stenosis as determined on invasive FFR.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Hemodinâmica , Tomografia Computadorizada Multidetectores , Imagem de Perfusão do Miocárdio/métodos , Adenosina/administração & dosagem , Idoso , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Vasodilatadores/administração & dosagem
19.
Radiology ; 249(1): 301-6, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18710960

RESUMO

The purpose of this study was to assess the blooming artifacts in ex vivo coronary arteries at multidetector computed tomography (CT) and flat-panel-volume CT by comparing measured areas of calcified plaque with respect to the reference standard of histopathologic findings. Three ex vivo hearts were scanned with multidetector CT and flat-panel-volume CT after institutional review board approval. The area of calcified plaque was measured at histopathologic examination, multidetector CT, and flat-panel-volume CT. The plaque area was overestimated at multidetector CT by 400% (4.61/1.15) on average, and the predicted difference between the measurements was significant (3.46 mm(2), P = .018). The average overestimation of plaque area at flat-panel-volume CT was twofold (214% [2.18/1.02]), and the predicted difference was smaller (1.16 mm(2), P = .08). The extent of the blooming artifact in visualizing calcified coronary plaque is reduced by using flat-panel-volume CT.


Assuntos
Calcinose/patologia , Vasos Coronários/patologia , Tomografia Computadorizada por Raios X/métodos , Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Coração/diagnóstico por imagem , Humanos , Sensibilidade e Especificidade
20.
Eur Heart J Cardiovasc Imaging ; 19(2): 127-135, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29045612

RESUMO

The aim of this paper is to provide a guide to the clinical application of the functional computed tomography (CT) techniques fractional flow reserve (CT FFR) and myocardial perfusion (CTP) in patients presenting for the evaluation of coronary artery disease (CAD). Both techniques have recently been introduced to complement coronary CT angiography (CTA) with physiological information. Evidence supporting their diagnostic accuracy accumulates at a fast pace, and both techniques are moving from research tools to clinical applications for specific subgroups of patients. As a consequence, the question that now emerges is how to optimally implement these techniques in the daily clinical workflow to maximize the benefit to patients. Given the inherent differences between both techniques in their underlying physical principles and methodology, as well as the types of pathophysiological information they provide, these techniques are not interchangeable. Rather, within the broad spectrum of patients presenting for CAD evaluation, both CT FFR and CTP may have their own optimized application where the highest benefit at the lowest risk and cost may be achieved. Therefore, we will review the physical principles and available clinical evidence of each technique, and propose how this information can be applied to the individual patient. Moreover, as techniques continue to mature, the combination of coronary CTA with CT FFR and/or CTP likely will become a powerful and accessible diagnostic tool for the detailed characterization of atherosclerotic disease providing a potentially more precise and personalized approach to patients with suspected CAD.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Interpretação de Imagem Assistida por Computador , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada por Raios X/métodos , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA