Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 45(10): 823-833, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38289867

RESUMO

BACKGROUND AND AIMS: An electrical storm (ES) is a clinical emergency with a paucity of established treatment options. Despite initial encouraging reports about the safety and effectiveness of percutaneous stellate ganglion block (PSGB), many questions remained unsettled and evidence from a prospective multicentre study was still lacking. For these purposes, the STAR study was designed. METHODS: This is a multicentre observational study enrolling patients suffering from an ES refractory to standard treatment from 1 July 2017 to 30 June 2023. The primary outcome was the reduction of treated arrhythmic events by at least 50% comparing the 12 h following PSGB with the 12 h before the procedure. STAR operators were specifically trained to both the anterior anatomical and the lateral ultrasound-guided approach. RESULTS: A total of 131 patients from 19 centres were enrolled and underwent 184 PSGBs. Patients were mainly male (83.2%) with a median age of 68 (63.8-69.2) years and a depressed left ventricular ejection fraction (25.0 ± 12.3%). The primary outcome was reached in 92% of patients, and the median reduction of arrhythmic episodes between 12 h before and after PSGB was 100% (interquartile range -100% to -92.3%). Arrhythmic episodes requiring treatment were significantly reduced comparing 12 h before the first PSGB with 12 h after the last procedure [six (3-15.8) vs. 0 (0-1), P < .0001] and comparing 1 h before with 1 h after each procedure [2 (0-6) vs. 0 (0-0), P < .001]. One major complication occurred (0.5%). CONCLUSIONS: The findings of this large, prospective, multicentre study provide evidence in favour of the effectiveness and safety of PSGB for the treatment of refractory ES.


Assuntos
Taquicardia Ventricular , Idoso , Feminino , Humanos , Masculino , Estudos Prospectivos , Gânglio Estrelado , Volume Sistólico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiologia , Resultado do Tratamento , Fibrilação Ventricular/etiologia , Função Ventricular Esquerda , Pessoa de Meia-Idade
2.
Artigo em Inglês | MEDLINE | ID: mdl-38818537

RESUMO

INTRODUCTION: During the SARS-CoV-2 COVID-19 pandemic, the global health system needed to review important processes involved in daily routines such as outpatient activities within the hospital, including follow-up visits of implantable cardiac electronic devices (CIEDs) carried out in office. The aim of this study is to describe our 3.5 years of real-world experience of a full remote CIED follow-up, evaluate the success rate of remote transmissions, and verify the adopted organizational model. METHODS: From April 2020 to November 2023, all patients with an activated and well-functioning remote monitoring (RM) system and automatic algorithms, like autocapture and autosensing, underwent exclusive RM follow-up. Unscheduled in-office visits were only prompted by remote yellow or red alerts. Patients were divided into two groups, based on available technology: Manual Transmission System (MTS) and Automatic Transmission System (ATS). The ATS group, in addition to ensuring a daily transmission of any yellow or red alerts, was checked at least every 15 days to ensure a valid connection. An automatic transmission was scheduled once a year, irrespective of alerts occurred. The MTS group provided a manual transmission every 6 months. RESULTS: One thousand nine hundred thirty-seven consecutive patients were included in the study. By the end of November 2023, a total of 1409 patients (1192 in the ATS and 217 in the MTS group) were still actively followed by our remote clinic (384 expired, 137 dismissed, 7 transferred). The overall success rate of transmissions with the adopted organizational model was 96.6% in the ATS group (connection index) and 87% in the MTS group. Conventional in-hospital follow-up visits decreased by 44%. Total clinic working time, resulting from the sum of the time spent during in-hospital and remote follow-up, after an initial increase, was progressively reduced to the actual -25%. Mortality rate for any cause was 7.5% per year in remote follow-up patients and 8.3% (p=NS) in in-office patients. In the ATS group, no device malfunctions were notified to our remote clinic, before we had already realized it through appropriate alerts. CONCLUSIONS: The available technology makes moving to a 100% remote clinic possible, without overwhelming clinic workflow, safely. Adopting an appropriate organizational model, it is possible to maintain high transmission success rates. The automatic transmissions allow a more frequent control of patients with CIED.

3.
BMC Cardiovasc Disord ; 22(1): 169, 2022 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-35421939

RESUMO

BACKGROUND: Radiofrequency ablation has been shown to be a safe and effective treatment for scar-related ventricular arrhythmias (VA). Recent preliminary studies have shown that real time integration of late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) images with electroanatomical map (EAM) data may lead to increased procedure efficacy, efficiency, and safety. METHODS: VOYAGE is a prospective, randomized, multicenter controlled open label study designed to compare in terms of efficacy, efficiency, and safety a CMR aided/guided workflow to standard EAM-guided ventricular tachycardia (VT) ablation. Patients with an ICD or with ICD implantation expected within 1 month, with scar related VT, suitable for CMR and multidetector computed tomography (MDCT) will be randomized to a CMR-guided or CMR-aided approach, whereas subjects unsuitable for imaging or with image quality deemed not sufficient for postprocessing will be allocated to standard of care ablation. Primary endpoint is defined as VT recurrences (sustained or requiring appropriate ICD intervention) during 12 months follow-up, excluding the first month of blanking period. Secondary endpoints will include procedural efficiency, safety, impact on quality of life and comparison between CMR-guided and CMR-aided approaches. Patients will be evaluated at 1, 6 and 12 months. DISCUSSION: The clinical impact of real time CMR-guided/aided ablation approaches has not been thoroughly assessed yet. This study aims at defining whether such workflow results in more effective, efficient, and safer procedures. If proven to be of benefit, results from this study could be applied in large scale interventional practice. Trial registrationClinicalTrials.gov, NCT04694079, registered on January 1, 2021.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Ablação por Cateter/efeitos adversos , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Cicatriz/patologia , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estudos Prospectivos , Qualidade de Vida , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia
4.
Pacing Clin Electrophysiol ; 44(7): 1267-1276, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33786840

RESUMO

Ventricular tachycardia and premature ventricular complexes (PVCs) arising from right ventricular outflow tract (RVOT) are the most common type of ventricular arrhythmias (VAs) in patients without structural heart disease. Radiofrequency ablation is now the gold standard of treatment in this setting due to high efficacy rates and optimal safety profile. During the last few years, the pulmonary valve (PV) and the pulmonary artery (PA) have attracted much attention as reliable sites of origin of RVOT-type arrhythmias. In the mean while intracardiac echocardiogram (ICE) has undoubtedly improved our understanding of the cardiac anatomy. Aim of this paper is to provide an illustrated step-by-step guide on how to use ICE with the CARTOSOUND module to visualize and reconstruct 3D shell of the RV, the PV, as well of other contiguous anatomical structures (i.e., the aortic valve and coronary arteries) to perform aware and safe ablation in this region.


Assuntos
Ecocardiografia , Imageamento Tridimensional , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Cirurgia Assistida por Computador , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos
5.
Europace ; 22(2): 274-280, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31942618

RESUMO

AIMS: Frequent premature ventricular complexes (PVCs) can induce or worsen left ventricular systolic dysfunction. We aimed to investigate the influence of the baseline QRS in the response after PVC ablation in patients with depressed left ventricular ejection fraction (LVEF). METHODS AND RESULTS: Two hundred and fifteen [59 ± 13 years old, 152 (71%) men] consecutive patients with left ventricular (LV) systolic dysfunction and frequent PVCs referred for ablation were included and followed-up for 12 months. Echocardiographic response was defined as an improvement of at least five absolute points in LVEF. Clinical, electrocardiogram, and electrophysiological characteristics were analysed. Mean baseline QRS duration was 110 ms [97-140]. Premature ventricular complex burden significantly decreased after ablation from 23% [16-33] at baseline to 1% [0-8] at 12 months, P < 0.001. Mean PVC burden reduction was 18 [8-30] points. There was a significant improvement of LVEF from 35% [29-40] at baseline to 44% [35-55] at 12 months, P < 0.001. One hundred and thirty (61%) patients were considered as echocardiographic responders. Baseline QRS duration (ms) [odds ratio (OR) 0.98 (0.97-0.99), P = 0.01] was an independent predictor of echocardiographic response. Mean LVEF improvement was 16 [10-21] points when the baseline QRS duration was <90 ms; 12 [4-20] when it was 90-110 ms; 5 [0-15] when it was 110 ± 130 ms; and 0 [0-6] points when it was >130 ms. CONCLUSIONS: In patients with LV systolic dysfunction, intrinsic QRS duration is inversely related to the probability and the degree of echocardiographic response after frequent PVC ablation. Patients with a QRS duration >130 ms at baseline have the poorer response after ablation.


Assuntos
Ablação por Cateter , Disfunção Ventricular Esquerda , Complexos Ventriculares Prematuros , Idoso , Eletrocardiografia , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/cirurgia , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
8.
Medicina (Kaunas) ; 55(8)2019 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-31434315

RESUMO

Stroke is a rare but possible complication after atrial fibrillation (AF) ablation. However, its etiopathogenesis is far from being completely characterized. Here we report a case of stroke, with recurrent peripheral embolism after AF ablation procedure. In our patient, an in situ femoral vein thrombosis and iatrogenic atrial septal defect were simultaneously detected. A comprehensive review of multiple pathophysiological mechanisms of stroke in this context is provided. The case underlines the importance of a global evaluation of patients undergoing AF ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Embolia/etiologia , Trombose/etiologia , Idoso , Humanos , Masculino , Complicações Pós-Operatórias
10.
J Heart Valve Dis ; 26(6): 700-707, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-30207121

RESUMO

BACKGROUND: The involvement of atrial embryonic remnants in infective endocarditis (IE) has seldom been reported. The study aim was to evaluate the prevalence of vegetations on right atrial embryonic remnants (RAER) in patients with a definitive diagnosis of IE. METHODS: Since 1998, all consecutive patients with suspected IE were referred to the authors' institution to undergo transesophageal echocardiography (TEE). Patients with a high probability of IE but with a negative result underwent a further TEE examination within 10 days. The involvement of RAER was investigated systematically. RESULTS: Among a total of 585 patients evaluated, definitive criteria for IE were present in 210 (35.9%). Right-sided IE was detected in 33 patients (15%); these included 21 infections on the tricuspid valve (65%), 10 cases of intracardiac electronic device infection (29%), one infection on the Thebesian valve (3%), and one on the pulmonary valve (3%). The incidence of right-sided IE was 0.84 per 100,000 population per year. RAER involvement was detected in five patients (15% of right-sided endocarditis), representing 2.5% of the complete IE series. The incidence of RAER endocarditis was 0.13 new cases per 100,000 population per year. The Eustachian and Thebesian valves were involved in four cases. Two patients presented with pulmonary embolism and died in hospital. Transthoracic echocardiography (TTE) allowed the detection of RAER vegetations in two cases. CONCLUSIONS: Although the prevalence of embryonic remnants involvement in IE is underestimated, it may carry an important embolic risk if undetected. As TTE demonstrated only a low sensitivity in the diagnosis of embryonic remnant involvement, TEE should be performed systematically and RAER involvement carefully sought. TEE is recommended in all patients with a high clinical suspicion of right-sided IE. Video 1: Mid-esophageal TEE view. Multiple vegetations attached onto the pacemaker leads (broken arrow) and on the Eustachian valve (solid arrow). Video 2: Mid-esophageal TEE view. A vegetation attached onto the tricuspid valve (broken arrow) and on the Eustachian valve (solid arrow).


Assuntos
Ecocardiografia Transesofagiana , Endocardite/diagnóstico por imagem , Átrios do Coração/anormalidades , Átrios do Coração/diagnóstico por imagem , Adulto , Idoso , Endocardite/microbiologia , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/microbiologia
11.
Alzheimers Dement ; 13(9): 1013-1023, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28263741

RESUMO

INTRODUCTION: Hippocampal volume is a core biomarker of Alzheimer's disease (AD). However, its contribution over the standard diagnostic workup is unclear. METHODS: Three hundred fifty-six patients, under clinical evaluation for cognitive impairment, with suspected AD and Mini-Mental State Examination ≥20, were recruited across 17 European memory clinics. After the traditional diagnostic workup, diagnostic confidence of AD pathology (DCAD) was estimated by the physicians in charge. The latter were provided with the results of automated hippocampal volumetry in standardized format and DCAD was reassessed. RESULTS: An increment of one interquartile range in hippocampal volume was associated with a mean change of DCAD of -8.0% (95% credible interval: [-11.5, -5.0]). Automated hippocampal volumetry showed a statistically significant impact on DCAD beyond the contributions of neuropsychology, 18F-fluorodeoxyglucose positron emission tomography/single-photon emission computed tomography, and cerebrospinal fluid markers (-8.5, CrI: [-11.5, -5.6]; -14.1, CrI: [-19.3, -8.8]; -10.6, CrI: [-14.6, -6.1], respectively). DISCUSSION: There is a measurable effect of hippocampal volume on DCAD even when used on top of the traditional diagnostic workup.


Assuntos
Doença de Alzheimer/diagnóstico , Doença de Alzheimer/patologia , Transtornos Cognitivos/etiologia , Diagnóstico por Computador , Hipocampo/patologia , Doença de Alzheimer/líquido cefalorraquidiano , Doença de Alzheimer/complicações , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Transtornos Cognitivos/diagnóstico por imagem , Diagnóstico Diferencial , Progressão da Doença , Europa (Continente) , Feminino , Fluordesoxiglucose F18/metabolismo , Humanos , Masculino , Testes Neuropsicológicos , Fragmentos de Peptídeos/líquido cefalorraquidiano , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada de Emissão de Fóton Único , Proteínas tau/líquido cefalorraquidiano
12.
Neuroimage ; 125: 834-847, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26515904

RESUMO

BACKGROUND: Structural MRI measures for monitoring Alzheimer's Disease (AD) progression are becoming instrumental in the clinical practice, and more so in the context of longitudinal studies. This investigation addresses the impact of four image analysis approaches on the longitudinal performance of the hippocampal volume. METHODS: We present a hippocampal segmentation algorithm and validate it on a gold-standard manual tracing database. We segmented 460 subjects from ADNI, each subject having been scanned twice at baseline, 12-month and 24month follow-up scan (1.5T, T1 MRI). We used the bilateral hippocampal volume v and its variation, measured as the annualized volume change Λ=δv/year(mm(3)/y). Four processing approaches with different complexity are compared to maximize the longitudinal information, and they are tested for cohort discrimination ability. Reference cohorts are Controls vs. Alzheimer's Disease (CTRL/AD) and CTRL vs. Mild Cognitive Impairment who subsequently progressed to AD dementia (CTRL/MCI-co). We discuss the conditions on v and the added value of Λ in discriminating subjects. RESULTS: The age-corrected bilateral annualized atrophy rate (%/year) were: -1.6 (0.6) for CTRL, -2.2 (1.0) for MCI-nc, -3.2 (1.2) for MCI-co and -4.0 (1.5) for AD. Combined (v, Λ) discrimination ability gave an Area under the ROC curve (auc)=0.93 for CTRL vs AD and auc=0.88 for CTRL vs MCI-co. CONCLUSIONS: Longitudinal volume measurements can provide meaningful clinical insight and added value with respect to the baseline provided the analysis procedure embeds the longitudinal information.


Assuntos
Doença de Alzheimer/diagnóstico , Hipocampo/patologia , Interpretação de Imagem Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Diagnóstico Precoce , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
14.
Europace ; 18(3): 450-6, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26017468

RESUMO

AIMS: Prevalence of left appendage thrombosis ranges from 6 to 18% in persistent atrial fibrillation (AF). Few and low sample size studies have assessed left and right atrial thrombosis in persistent atrial flutter (AFL) and a wide variety of frequencies, from 1 to 21%, has been reported. The aim of this study was to evaluate the prevalence of atrial appendage thrombosis in a large population of patients undergoing transoesophageal echocardiography (TEE)-guided cardioversion (CV) for recent AFL onset and compare it with AF. METHODS AND RESULTS: From 1999 to September 2014, we collected data of 1081 patients to CV: 877 affected by AF (81.1%) and 204 by AFL (18.9%). The presence of auricular thrombosis was evaluated by TEE in AF or AFL persisting for more than 48 h. The presence of appendage thrombosis, Doppler emptying velocities, and severe spontaneous echo contrast (SEC) was studied. The overall prevalence of atrial thrombosis was 9.62% (104/1081). Frequency of atrial thrombosis in AFL patients was 6.4% (13/204) vs. 10.5% among AF (92/877), P = 0.074. Comparing the two appendages, frequency of left atrial appendage thrombosis was in AFL 5.9% (12/204) vs. 9.9% (87/877) in the AF group, P = 0.07. Right atrial appendage thrombosis was present in 0.5% (1/204) in the AFL group vs. 0.8% (7/877) in the AF group, P = 0.64. Moderate to severe SEC (3+/4+) was present in 28% of AFL patients (57/204) vs. 35% of AF patients (307/877), P = 0.05. CONCLUSION: Auricular thrombosis is not an infrequent finding in AFL before CV. Our study suggests the use of TEE screening in AFL, as well as in AF, when patients arrive to clinical attention after more than 48 h from arrhythmia onset.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Flutter Atrial/diagnóstico por imagem , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Cardioversão Elétrica , Trombose/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/epidemiologia , Flutter Atrial/epidemiologia , Flutter Atrial/terapia , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Índice de Gravidade de Doença , Trombose/epidemiologia , Fatores de Tempo
15.
Pacing Clin Electrophysiol ; 39(8): 830-6, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27119309

RESUMO

BACKGROUND: Based upon the results of a previous small pilot study, we present the results of a prospective single-center randomized study comparing the performance of the implantable loop recorder (ILR) at two implanting sites. METHODS: A group of patients whose ILRs were implanted via a left axillary approach were compared with a group who received an ILR in the traditional left site of the chest. Follow-up (FU) was scheduled every 6 months or when symptoms occurred. All patients enrolled in the study had a complete FU from implantation to explantation. R- and P-wave amplitudes were measured at implantation and during FU. Explantation of the device was programmed at the end of service life or when ILR analysis resulted in a complete and exhaustive diagnosis. RESULTS: Sixty-three patients were enrolled (70 ± 12 years, range: 21-92, 59% male): 31 standard and 32 with axillary access. The R-wave amplitude obtained with the new technique was comparable with that obtained with the standard procedure. The diagnostic accuracy of the ILR was comparable in the two groups. The axillary implantation procedure was slightly longer but no complications were observed. CONCLUSION: This long-term randomized study confirmed that axillary access for ILR implantation is feasible, safe, well tolerated, and reliable in terms of device performance. Moreover, it is aesthetically superior to the standard approach and carries the potential of minimizing permanent scarring after ILR extraction.


Assuntos
Fibrilação Atrial/diagnóstico , Axila/cirurgia , Eletrocardiografia Ambulatorial/instrumentação , Próteses e Implantes , Implantação de Prótese/métodos , Procedimentos Cirúrgicos Torácicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Armazenamento e Recuperação da Informação/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Adulto Jovem
16.
Neuroimage ; 111: 562-79, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-25652394

RESUMO

Algorithms for computer-aided diagnosis of dementia based on structural MRI have demonstrated high performance in the literature, but are difficult to compare as different data sets and methodology were used for evaluation. In addition, it is unclear how the algorithms would perform on previously unseen data, and thus, how they would perform in clinical practice when there is no real opportunity to adapt the algorithm to the data at hand. To address these comparability, generalizability and clinical applicability issues, we organized a grand challenge that aimed to objectively compare algorithms based on a clinically representative multi-center data set. Using clinical practice as the starting point, the goal was to reproduce the clinical diagnosis. Therefore, we evaluated algorithms for multi-class classification of three diagnostic groups: patients with probable Alzheimer's disease, patients with mild cognitive impairment and healthy controls. The diagnosis based on clinical criteria was used as reference standard, as it was the best available reference despite its known limitations. For evaluation, a previously unseen test set was used consisting of 354 T1-weighted MRI scans with the diagnoses blinded. Fifteen research teams participated with a total of 29 algorithms. The algorithms were trained on a small training set (n=30) and optionally on data from other sources (e.g., the Alzheimer's Disease Neuroimaging Initiative, the Australian Imaging Biomarkers and Lifestyle flagship study of aging). The best performing algorithm yielded an accuracy of 63.0% and an area under the receiver-operating-characteristic curve (AUC) of 78.8%. In general, the best performances were achieved using feature extraction based on voxel-based morphometry or a combination of features that included volume, cortical thickness, shape and intensity. The challenge is open for new submissions via the web-based framework: http://caddementia.grand-challenge.org.


Assuntos
Algoritmos , Doença de Alzheimer/diagnóstico , Disfunção Cognitiva/diagnóstico , Diagnóstico por Computador/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/classificação , Disfunção Cognitiva/classificação , Diagnóstico por Computador/normas , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/normas , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
18.
Pacing Clin Electrophysiol ; 38(8): 909-13, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25974662

RESUMO

Pocket hematoma is a common complication of cardiac implantable electronic device procedures and a potential risk factor for device infections, especially in patients on oral anticoagulation or antiplatelet treatment. There is a wide variability in the incidence of pocket hematoma and bleeding complications in the literature and the major cause for this seems to be the variability of the used definitions for hematomas. The lack of generally accepted definition for pocket hematoma renders the comparisons across the studies difficult. In this article, we briefly review the current literature on this issue and propose a uniform definition for pocket hematoma and criteria for grading the severity of hematoma in clinical practice and research.


Assuntos
Hematoma/etiologia , Marca-Passo Artificial/efeitos adversos , Terminologia como Assunto , Humanos
19.
Indian Pacing Electrophysiol J ; 14(6): 301-5, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25609898

RESUMO

A 62-year-old man admitted for presyncope presented two symptomatic sustained ventricular tachycardia with right bundle branch morphology and inferior axis suggesting a pathology of the left ventricular lateral wall, the site where Cardiac Magnetic Resonance demonstrated a thinned, hypokinetic segment with fibro-fatty subepicardial infiltration. A very localized Left Dominant Arrhythmogenic Cardiomyopathy was diagnosed and an ICD implanted.

20.
Anatol J Cardiol ; 28(1): 44-54, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38167795

RESUMO

BACKGROUND: Large-scale multicentric studies reported that, despite advances in diagnosis, antibiotics, and surgical treatment, infective endocarditis (IE) in-hospital mortality remains high. Most data have been obtained from patients treated in infective disease wards, internal medicine, cardiology, or cardiac surgery departments and are therefore heterogeneous. The few studies focused on complicated IE patients leading to intensive care unit (ICU) admission have reported different methodologies and results. The aim of our study was to describe the epidemiological, clinical, and microbial features of critically ill patients admitted to the ICU with a definite IE diagnosis. METHODS: We conducted a prospective case-series population study from January 1, 1998, to December 31, 2020. Patients were divided into 2 groups: 'Ward' (group 1) and 'ICU' patients (group 2), and a 1-year follow-up was performed. RESULTS: After performing a univariate and multivariate logistic regression analysis, we found that the independent predictors of ICU admission were vegetation diameter >10 mm, abnormal PaO2/FiO2 ratio, and acute heart failure. Five independent mortality risk factors were identified: SOFA score >14, not performing surgery, age >70 years, acute heart failure, and embolic complications. CONCLUSIONS: Infective endocarditis in-hospital mortality remains high. ICU admission and mortality can be predicted by independent risk factors.


Assuntos
Endocardite Bacteriana , Endocardite , Insuficiência Cardíaca , Humanos , Idoso , Estudos Retrospectivos , Endocardite Bacteriana/diagnóstico , Endocardite/diagnóstico , Unidades de Terapia Intensiva , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA