Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 89(18): 9654-9663, 2017 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-28816040

RESUMO

In this work, all three electrodes in an electrochemical cell were fabricated based on carbon nanotube (CNT) thread. CNT thread partially insulated with a thin polystyrene coating to define the microelectrode area was used as the working electrode; bare CNT thread was used as the auxiliary electrode; and a micro quasi-reference electrode was fabricated by electroplating CNT thread with Ag and then anodizing it in chloride solution to form a layer of AgCl. The Ag|AgCl coated CNT thread electrode provided a stable potential comparable to the conventional liquid-junction type Ag|AgCl reference electrode. The CNT thread auxiliary electrode provided a stable current, which is comparable to a Pt wire auxiliary electrode. This all-CNT thread three electrode cell has been evaluated as a microsensor for the simultaneous determination of trace levels of heavy metal ions by anodic stripping voltammetry (ASV). Hg2+, Cu2+, and Pb2+ were used as a representative system for this study. The calculated detection limits (based on the 3σ method) with a 120 s deposition time are 1.05, 0.53, and 0.57 nM for Hg2+, Cu2+, and Pb2+, respectively. These electrodes significantly reduce the dimensions of the conventional three electrode electrochemical cell to the microscale.


Assuntos
Cobre/análise , Técnicas Eletroquímicas , Chumbo/análise , Mercúrio/análise , Nanotubos de Carbono/química , Eletrodos , Tamanho da Partícula , Propriedades de Superfície
2.
Anal Chem ; 87(19): 9687-95, 2015 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-26291731

RESUMO

Carbon nanotube (CNT) film was evaluated as an optically transparent electrode (OTE) for thin layer spectroelectrochemistry. Chemically inert CNT arrays were synthesized by chemical vapor deposition (CVD) using thin films of Fe and Co as catalysts. Vertically aligned CNT arrays were drawn onto a quartz slide to form CNT films that constituted the OTE. Adequate conductivity and transparency make this material a good OTE for spectroelectrochemistry. These properties could be varied by the number of layers of CNTs used to form the OTE. Detection in the UV/near UV region down to 200 nm can be achieved using these transparent CNT films on quartz. The OTE was characterized by transmission electron microscopy, scanning electron microscopy, Raman spectroscopy, UV-visible spectroscopy, cyclic voltammetry, electrochemical impedance spectroscopy, and thin layer spectroelectrochemistry. Ferricyanide, tris(2,2'-bipyridine) ruthenium(II) chloride, and cytochrome c were used as representative redox probes for thin layer spectroelectrochemistry using the CNT film OTE, and the results correlated well with their known properties. Direct electron transfer of cytochrome c was achieved on the CNT film electrode.


Assuntos
Técnicas Eletroquímicas , Nanotubos de Carbono/química , Eletrodos , Fenômenos Ópticos
3.
Langmuir ; 31(27): 7616-22, 2015 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-26083044

RESUMO

Free-standing thin carbon nanotube (CNT) sheets are challenging to handle and control for device fabrication. In this paper, we report on the inverse-ordered fabrication method from thick CNT sheets to thin free-standing CNT sheets. As proof of the concept, thin CNT sheets for a supercapacitor were fabricated from 200 thick layers. The results show that the thin CNT sheet was electrochemically stable and had enhanced capacitive performance. The smaller the number of layers is, the larger the specific capacitances we have (from 10.10 F g(-1) to 51.37 F g(-1)). Energy and power density were increased from 0.50 to 2.57 Wh kg(-1) and from 0.33 to 2.31 kW kg(-1), respectively. This simple and scalable inverse-ordered method is capable to fabricate CNT sheets in various forms, allowing fast trials on various applications.

4.
J Nanosci Nanotechnol ; 7(7): 2293-300, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17663243

RESUMO

A carbon nanotube needle biosensor was developed to provide fast, cost effective and highly sensitive electrochemical detection of biomolecules. The sensor was fabricated based on an array of aligned multi-wall carbon nanotubes synthesized by chemical vapor deposition. A bundle of nanotubes in the array was welded onto the tip of a tungsten needle under a microscope. The needle was then encased in glass and a polymer coating leaving only the tip of the needle exposed. Cyclic voltammetry was performed to examine the redox behavior of the nanotube needle. The cyclic voltammetry results showed a steady-state response attributable to radial diffusion with a high steady-state current density. An amperometric sensor was then developed for glucose detection by physically attaching glucose oxidase on the nanotube needle. The amperometric response of these nanotube needles showed a high sensitivity with a low detection limit. It is expected that the nanotube needle can be sharpened to increase the sensitivity to the point where the current is almost too small to measure. The simple manufacturing method should allow commodity level production of highly sensitive electronic biosensors.


Assuntos
Técnicas Biossensoriais/instrumentação , Eletroquímica/instrumentação , Glucose Oxidase/química , Glucose/análise , Microeletrodos , Nanotubos de Carbono/química , Nanotubos de Carbono/ultraestrutura , Técnicas Biossensoriais/métodos , Cristalização/métodos , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Nanotecnologia/instrumentação , Nanotecnologia/métodos , Agulhas , Tamanho da Partícula , Sensibilidade e Especificidade , Propriedades de Superfície
5.
Sci Rep ; 7(1): 1173, 2017 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-28446750

RESUMO

A bioresorbable metallic helical stent was explored as a new device opportunity (magnesium scaffold), which can be absorbed by the body without leaving a trace and simultaneously allowing restoration of vasoreactivity with the potential for vessel remodeling. In this study, developed Mg-based helical stent was inserted and expanded in vessels with subsequent degradation in various environments including static, dynamic, and porcine ex vivo models. By assessing stent degradation in three different environments, we observed: (1) stress- and flow-induced degradation; (2) a high degradation rate in the dynamic reactor; (3) production of intermediate products (MgO/Mg(OH)2 and Ca/P) during degradation; and (4) intermediate micro-gas pocket formation in the neighboring tissue ex vivo model. Overall, the expandable Mg-based helical stent employed as a scaffold performed well, with expansion rate (>100%) in porcine ex vivo model.


Assuntos
Implantes Absorvíveis , Magnésio , Stents , Procedimentos Cirúrgicos Vasculares/instrumentação , Animais , Suínos
6.
Micromachines (Basel) ; 7(4)2016 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-30407444

RESUMO

Here, we report on carbon nanotube paper-based electroanalytical devices. A highly aligned-carbon nanotube (HA-CNT) array, grown using chemical vapor deposition (CVD), was processed to form bi-layered paper with an integrated cellulose-based Origami-chip as the electroanalytical device. We used an inverse-ordered fabrication method from a thick carbon nanotube (CNT) sheet to a thin CNT sheet. A 200-layered HA-CNT sheet and a 100-layered HA-CNT sheet are explored as a working electrode. The device was fabricated using the following methods: (1) cellulose-based paper was patterned using a wax printer, (2) electrical connection was made using a silver ink-based circuit printer, and (3) three electrodes were stacked on a 2D Origami cell. Electrochemical behavior was evaluated using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). We believe that this platform could attract a great deal of interest for use in various chemical and biomedical applications.

7.
Acta Biomater ; 36: 361-8, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27045693

RESUMO

UNLABELLED: Monitoring the biodegradation process of magnesium and its alloys in vivo is challenging. Currently, this process is monitored by micro-CT and X-ray imaging in vivo, which require large and costly instrumentation. Here we report a simple and effective methodology to monitor the biodegradation process in vivo by sensing H2 transdermally above a magnesium sample implanted subcutaneously in a mouse. An electrochemical H2 microsensor was used to measure the biodegradation product H2 at the surface of the skin for two magnesium alloys (ZK40 and AZ31) and one high purity magnesium single crystal (Mg8H). The sensor was able to easily detect low levels of H2 (30-400µM) permeating through the skin with a response time of about 30s. H2 levels were correlated with the biodegradation rate as determined from weight loss measurements of the implants. This new method is noninvasive, fast and requires no major equipment. STATEMENT OF SIGNIFICANCE: Biomedical devices such as plates and screws used for broken bone repair are being developed out of biodegradable magnesium alloys that gradually dissolve when no longer needed. This avoids subsequent removal by surgery, which may be necessary if complications arise. A rapid, non-invasive means for monitoring the biodegradation process in vivo is needed for animal testing and point of care (POC) evaluation of patients. Here we report a novel, simple, fast, and noninvasive method to monitor the biodegradation of magnesium in vivo by measuring the biodegradation product H2 with an electrochemical H2 sensor. Since H2 rapidly permeates through biological tissue, measurements are made by simply pressing the sensor tip against the skin above the implant; the response is within 30s.


Assuntos
Implantes Absorvíveis , Ligas , Técnicas Eletroquímicas/métodos , Hidrogênio/análise , Magnésio , Pele/metabolismo , Ligas/química , Ligas/farmacologia , Animais , Técnicas Eletroquímicas/instrumentação , Feminino , Hidrogênio/metabolismo , Magnésio/química , Magnésio/farmacologia , Camundongos , Camundongos Nus
8.
J Colloid Interface Sci ; 448: 148-55, 2015 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-25725399

RESUMO

We report on the development of a new photoactive material via titania (TiO2) nanoparticle deposition on free-standing aligned carbon nanotube (CNT) sheets. Controlling homogeneous dispersion of negatively charged TiO2 nanoparticles, achieved by adjusting pH higher than the point of zero charge (PZC), influenced electrochemical deposition of TiO2 on CNT sheets substrate. Varying deposition time with constant voltage, 5 V allowed different thickness of TiO2 to be deposited layer on the CNT sheets. The thickness and morphology of CNT-TiO2 sheets was verified by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (XRD). Electrochemical experiments show that diffusion coefficient of Fe(CN)6(3-) was 5.56×10(-6) cm(2) s(-1) at pristine CNT sheets and 2.19×10(-6) cm(2) s(-1) at the CNT-TiO2 sheets. Photocatalytic activity for CNT-TiO2 sheets exhibits high photocurrent density (when deposition time=30 min, 4.3 µA cm(-2) in N2, 13.4 µA cm(-2) in CO2). This paper proved a possibility to use CNT-TiO2 sheets based on highly-aligned CNT sheets substrate as new photoactive material.

9.
Nanotechnology ; 18(46): 465505, 2007 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-21730479

RESUMO

Highly aligned multi-wall carbon nanotubes were synthesized in the shape of towers and embedded into fluidic channels as electrodes for impedance measurement of LNCaP human prostate cancer cells. Tower electrodes up to 8 mm high were grown and easily peeled off a silicon substrate. The nanotube electrodes were then successfully soldered onto patterned printed circuit boards and cast into epoxy under pressure. After polishing the top of the tower electrodes, RF plasma was used to enhance the electrocatalytic effect by removing excess epoxy and activating the open end of the nanotubes. Electrodeposition of Au particles on the plasma-treated tower electrodes was done at a controlled density. Finally, the nanotube electrodes were embedded into a polydimethylsiloxane (PDMS) channel and electrochemical impedance spectroscopy was carried out with different conditions. Preliminary electrochemical impedance spectroscopy results using deionized water, buffer solution, and LNCaP prostate cancer cells showed that nanotube electrodes can distinguish the different solutions and could be used in future cell-based biosensor development.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA