Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38657159

RESUMO

OBJECTIVE: Hyperdense artery sign (HAS) on noncontrast brain computed tomography (CT) indicates an acute thrombus within the cerebral artery. It is a valuable imaging biomarker for diagnosing large-vessel occlusion; however, its identification may be challenging with the presence of vascular calcification. Dual-energy CT virtual noncalcium (VNCa) imaging using a 3-material decomposition algorithm is helpful for differentiating between calcification and hemorrhage. This study aimed to clarify the potential of VNCa imaging for differentiating HAS from vascular calcification. METHODS: Patients with acute ischemic stroke and large-vessel occlusion identified on MR angiography, who also underwent noncontrast dual-energy CT, were included. The 80 kV/Sn 140 kV mixed images, with a weighting factor of 0.4, were considered 120 kVp-equivalent images. Postprocessing using a 3-material decomposition algorithm to differentiate between calcium (Ca), cerebrospinal fluid, and hemorrhage was performed via a commercially available 3-dimensional workstation. A mixed image, VNCa image, color-coded Ca image, and color-coded Ca image with VNCa image overlay (color-coded Ca-overlay image) were obtained, and axial reconstruction with a 1-mm slice thickness was performed for each image type. Two experienced neuroradiologists conducted imaging evaluations in consensus. RESULTS: Thirty-four patients (mean age, 76.0 years; 21 male and 13 female patients) were included. The mixed and VNCa images revealed an HAS (indicating an acute clot) corresponding to the large-vessel occlusion site in 30 patients. Among them, the VNCa and color-coded Ca-overlay images enabled clear differentiation between the acute thrombus and adjacent vessel wall calcification in 5 patients. Among the other 4 patients, the VNCa, Ca-overlay, and Ca images identified calcified cerebral emboli in the M1 segment in 1 patient. For the other 3 patients, no high attenuation corresponding to magnetic resonance angiography findings was observed in any of the mixed, VNCa, Ca-overlay, or Ca images. CONCLUSIONS: VNCa and color-coded Ca-overlay images obtained via dual-energy brain CT enabled differentiation of acute thrombus from vessel wall calcification and calcified cerebral emboli in patients with acute ischemic stroke.

2.
BMC Womens Health ; 24(1): 330, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38849887

RESUMO

BACKGROUND: Premenstrual syndrome (PMS) is a severe problem in women, and a well-balanced diet helps improve PMS symptoms. Eating disturbances are a major health problem in young women. Limited research has explored the correlation between eating behaviors and PMS symptoms in Japan. This study aimed to compare eating disturbances and the severity of PMS symptoms in college students. METHODS: This study was conducted among female college students using an online questionnaire. The questionnaire included basic information (age, height, and weight), PMS symptoms, and eating behaviors assessed using the Eating Attitudes Test 26. RESULTS: The proportion of those with PMS symptoms who were disturbed by PMS symptoms was significantly higher in the group with eating disturbance. Those who were affected by the physical symptoms of PMS had significantly higher scores on the subscales related to diet, bulimia and food preoccupation. CONCLUSION: The results showed an association between PMS symptom severity and eating disturbance. The findings of this study indicate that individuals with eating disturbances may experience adverse effects on PMS symptoms, even in cases where weight is not at the extremes of excessive underweight or obesity.


Assuntos
Comportamento Alimentar , Transtornos da Alimentação e da Ingestão de Alimentos , Síndrome Pré-Menstrual , Estudantes , Humanos , Feminino , Síndrome Pré-Menstrual/psicologia , Estudos Transversais , Estudantes/estatística & dados numéricos , Estudantes/psicologia , Adulto Jovem , Transtornos da Alimentação e da Ingestão de Alimentos/psicologia , Transtornos da Alimentação e da Ingestão de Alimentos/complicações , Transtornos da Alimentação e da Ingestão de Alimentos/epidemiologia , Inquéritos e Questionários , Japão/epidemiologia , Universidades , Comportamento Alimentar/psicologia , Adulto , Adolescente , Índice de Gravidade de Doença
3.
J Infect Chemother ; 28(6): 840-843, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35277343

RESUMO

INTRODUCTION: Since respiratory sample collection is an uncomfortable experience, simultaneous detection of pathogens with a single swab is preferable. We prospectively evaluated the clinical performance of a newly developed antigen test QuickNavi-Flu+COVID19 Ag (Denka Co., Ltd., Tokyo, Japan) which can detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza viruses at the same time with a single testing device. METHODS: We included those who were suspected of contracting coronavirus disease 2019 (COVID-19) and were referred to a PCR center at Ibaraki prefecture in Japan, between August 2, 2021 to September 13, 2021, when the variant carrying L452R spike mutation of SARS-CoV-2 were prevalent. Additional nasopharyngeal samples and anterior nasal samples were obtained for the antigen test and were compared with a reference real-time reverse transcription PCR (RT-PCR) using nasopharyngeal samples. RESULTS: In total, 1510 nasopharyngeal samples and 862 anterior nasal samples were evaluated. During the study period, influenza viruses were not detected by QuickNavi-Flu+COVID19 Ag and reference real-time RT-PCR. For SARS-CoV-2 detection in nasopharyngeal samples, the sensitivity and specificity of the antigen test were 80.9% and 99.8%, respectively. The sensitivity and specificity using anterior nasal samples were 67.8% and 100%, respectively. In symptomatic cases, the sensitivities increased to 88.3% with nasopharyngeal samples and 73.7% with anterior nasal samples. There were three cases of discrepant results between the antigen test and the real-time RT-PCR. All of them were positive with the antigen test but negative with the real-time RT-PCR in SARS-CoV-2 detection. CONCLUSION: A combo kit, QuickNavi-Flu+COVID19 Ag, showed an acceptable sensitivity and sufficient specificity for SARS-CoV-2 detection, especially using nasopharyngeal sample collected from symptomatic patients.


Assuntos
COVID-19 , Antígenos Virais/análise , COVID-19/diagnóstico , Teste Sorológico para COVID-19 , Humanos , Nasofaringe , SARS-CoV-2/genética , Sensibilidade e Especificidade
4.
Retina ; 41(10): 2148-2156, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33734190

RESUMO

PURPOSE: To quantify the vessels of Haller's layer of normal subjects in en-face optical coherence tomographic images. METHODS: One hundred and seventy-two normal eyes were studied. En-face images of the top 25% slab of Haller's layer was analyzed. The vessel area, vessel length, and mean vessel diameter were calculated. The vessel running pattern was quantified for the degree of symmetry and designated as the "symmetry index." The coefficient of correlation between each choroidal parameter and the age, sex, axial length, and central choroidal thickness was determined. RESULTS: The vessel area was 23.4 ± 3.6 mm2, vessel length was 164.6 ± 24.1 mm, mean vessel diameter was 0.143 ± 0.019 mm, and the symmetry index was 58.6 ± 6.1%. Multiple regression analysis showed that the vessel area was significantly correlated with the age (R = -0.421, P < 0.001) and central choroidal thickness (R = 0.315, P < 0.001). The vessel length was significantly correlated with the age (R = -0.391, P = 0.024) and central choroidal thickness (R = -0.410, P < 0.001). The mean vessel diameter was significantly correlated with the age (R = -0.107, P = 0.024) and central choroidal thickness (R = 0.775, P < 0.001). The correlation between the symmetry index and any clinical findings was not significant. CONCLUSION: Quantification of en-face images of Haller's layer provide new biomarkers of the choroid.


Assuntos
Corioide/irrigação sanguínea , Corioide/diagnóstico por imagem , Tomografia de Coerência Óptica , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais , Adulto Jovem
5.
Graefes Arch Clin Exp Ophthalmol ; 257(9): 1879-1887, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31236669

RESUMO

PURPOSE: To evaluate the new method to quantitate the running pattern of the vessels in Haller's layer in en face optical coherence tomographic (OCT) images using the new algorithm. METHODS: A retrospective and cross-sectional study. The en face image of top 25% slab of Haller's layer was analyzed. The vascular area in these images was calculated after binarization. Then, the vessels were thinned, and the total length of the vessels and the mean vessel diameter were calculated. Based on the angle of vessel running, "natural oblique vessel" was defined. The ratio of the natural oblique vessel to the whole vessels was defined as the "symmetry index". To examine the reproducibility of the software, the images obtained on two different examination dates of the same subject (25 eyes of 25 healthy subjects) were analyzed. Also, to compare the symmetry index and subjective evaluations, 180 eyes and 180 healthy subjects were analyzed. The subjective evaluations classified the images into 3 groups, the Symmetrical, Semi-symmetrical, and Asymmetrical types. Symmetry index was compared in each group. RESULTS: The inter-measurement correlation coefficient (ICC) of the vessel area, vessel length, and vessel diameter were 0.955, 0.934, and 0.954, respectively. The ICC of the symmetry index was 0.926. The symmetry index of the Symmetrical type was 60.4 ± 7.2%, that of the Semi-symmetry type was 56.2 ± 4.6%, and that of the Asymmetry type was 52.6 ± 5.2%. CONCLUSIONS: The present algorithm can analyze vessels in Haller's layer of the en face images of choroid in an objective manner with good repeatability.


Assuntos
Algoritmos , Corioide/irrigação sanguínea , Imageamento Tridimensional , Aprendizado de Máquina , Vasos Retinianos/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Neuroradiology ; 60(4): 391-401, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29450601

RESUMO

PURPOSE: Imaging findings of pilocytic astrocytoma (PA) vary widely, sometimes resembling those of high-grade glioma (HGG). This study aimed to identify the imaging parameters that can be used to differentiate PA from HGG. METHODS: Altogether, 60 patients with PAs and 138 patients with HGGs were included in the study. Tumor properties and the presence of hydrocephalus, peritumoral edema, and dissemination were evaluated. We also measured the maximum relative cerebral blood flow (rCBFmax) and volume (rCBVmax) and determined the minimum apparent diffusion coefficient (ADCmin) in the tumor's solid components. The relative T1 (rT1), T2 (rT2), and contrast-enhanced T1 (rCE-T1) intensity values were evaluated. Parameters were compared between PAs and HGGs using the Mann-Whitney U test. Receiver operating characteristic (ROC) curve analysis was also used to evaluate these imaging parameters. A value of P < .05 was considered to indicate significance. RESULTS: Intratumoral hemorrhage and calcification were observed in 10.0% and 21.7% of PAs, respectively. The rCBFmax and rCBVmax values were significantly lower in PAs (0.50 ± 0.35, 1.82 ± 1.21) than those in HGGs (2.98 ± 1.80, 9.54 ± 6.88) (P < .0001, P = .0002, respectively). The ADCmin values were significantly higher in PAs (1.36 ± 0.56 × 10-3 mm2/s) than those in HGGs (0.86 ± 0.37 × 10-3 mm2/s) (P < .0001). ROC analysis showed that the best diagnostic performance was achieved with rCBFmax. CONCLUSION: The rCBFmax, rCBVmax, and ADCmin can differentiate PAs from HGGs.


Assuntos
Astrocitoma/diagnóstico por imagem , Astrocitoma/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Glioma/diagnóstico por imagem , Glioma/patologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Lactente , Japão , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estudos Retrospectivos
8.
Acta Radiol ; 59(11): 1372-1379, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29471670

RESUMO

Background Detecting recurrence of glioma on magnetic resonance imaging (MRI) is getting more and more important, especially after administration of new anti-tumor agent. However, it is still hard to identify. Purpose To examine the utility of intravoxel incoherent motion (IVIM) MRI and arterial spin labeling-cerebral blood flow (ASL-CBF) for recurrent glioma after initiation of bevacizumab (BEV) treatment. Material and Methods Thirteen patients (7 men, 6 women; age range = 41-82 years) with glioma (high grade, n = 11; low grade, n = 2) were enrolled in the study. IVIM parameters including apparent diffusion coefficient (ADC), true diffusion coefficient (D), and perfusion fraction (f) were obtained with 14 different b-values. We identified tumor progression during BEV therapy by MRI monitoring consisting of diffusion-weighted imaging (DWI), fluid-attenuated inversion recovery (FLAIR) imaging, and contrast-enhanced T1-weighted (CE-T1W) imaging by measuring tumor area. We also measured each parameter of IVIM and ASL-CBF, and calculated relative ADC (rADC), relative D (rD), relative f (rf), and relative CBF (rCBF) by obtaining the ratio between each area and the contralateral cerebral white matter. We calculated the rate of change (Δ) by subtracting values from those from the preceding MRI study, and obtained Spearman's rank correlation coefficient (rs). Results Tumor progression was identified in nine patients (high grade, n = 7; low grade, n = 2). Negative correlations were identified between ΔrD and ΔDWI area (rs = -0.583), and between ΔrD and ΔCE-T1W imaging area (rs = -0.605). Conclusion Tumor progression after BEV treatment can be identified by decreasing rD.


Assuntos
Antineoplásicos Imunológicos/uso terapêutico , Bevacizumab/uso terapêutico , Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/tratamento farmacológico , Meios de Contraste , Feminino , Glioma/tratamento farmacológico , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Marcadores de Spin
9.
Acta Radiol ; 59(5): 593-598, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28743197

RESUMO

Background Both neuromelanin-sensitive magnetic resonance imaging (NmMRI) and 123I-FP-CIT single photon emission computed tomography (SPECT) (DaTSCAN) assist the diagnosis of Parkinson's disease (PD). However, there have been few studies investigating a correlation between them. Purpose To correlate the utility of NmMRI and DaTSCAN and to evaluate the relationship between both imaging findings and the Unified PD rating scale part III (UPDRS III) score for the diagnosis and management of PD. Material and Methods Seventeen patients with PD who underwent both NmMRI and DaTSCAN were included. We measured the volume of the neuromelanin-positive substantia nigra pars compacta (SNc volume) on NmMRI and measured the specific binding ratio (SBR) on DaTSCAN. The asymmetry index (AI) of the SNc volume and SBR were also calculated. We evaluated the relationship between the UPDRS III score and the SNc volume and SBR, respectively. Results The SNc volume showed a significant correlation with the SBR. The AIs of them also showed a significant correlation. Both the mean of the bilateral SBR and the mean of the bilateral SNc volume showed significant negative correlations with the UPDRS III score. However, the correlation between the SBR and the UPDRS III score was stronger than that between the SNc volume and the UPDRS III score. Conclusion Both NmMRI and DaTSCAN are helpful for PD diagnosis. However, we conclude that DaTSCAN is more suitable for the evaluation of the clinical motor severity and would be more useful for the management of PD patients than NmMRI.


Assuntos
Imageamento por Ressonância Magnética/métodos , Doença de Parkinson/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Melaninas , Pessoa de Meia-Idade , Estudos Retrospectivos , Substância Negra/patologia , Tropanos
10.
Neuroradiology ; 59(3): 231-235, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28255903

RESUMO

PURPOSE: The aim of this study is to assess the value of adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR) for reduction of metal artifacts due to dental hardware in carotid CT angiography (CTA). METHODS: Thirty-seven patients with dental hardware who underwent carotid CTA were included. CTA was performed with a GE Discovery CT750 HD scanner and reconstructed with filtered back projection (FBP), ASIR, and MBIR. We measured the standard deviation at the cervical segment of the internal carotid artery that was affected most by dental metal artifacts (SD1) and the standard deviation at the common carotid artery that was not affected by the artifact (SD2). We calculated the artifact index (AI) as follows: AI = [(SD1)2 - (SD2)2]1/2 and compared each AI for FBP, ASIR, and MBIR. Visual assessment of the internal carotid artery was also performed by two neuroradiologists using a five-point scale for each axial and reconstructed sagittal image. The inter-observer agreement was analyzed using weighted kappa analysis. RESULTS: MBIR significantly improved AI compared with FBP and ASIR (p < 0.001, each). We found no significant difference in AI between FBP and ASIR (p = 0.502). The visual score of MBIR was significantly better than those of FBP and ASIR (p < 0.001, each), whereas the scores of ASIR were the same as those of FBP. Kappa values indicated good inter-observer agreements in all reconstructed images (0.747-0.778). CONCLUSIONS: MBIR resulted in a significant reduction in artifact from dental hardware in carotid CTA.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada , Prótese Dentária , Metais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iohexol , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
J Stroke Cerebrovasc Dis ; 26(7): 1457-1461, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28385516

RESUMO

BACKGROUND: The congestion of spin-labeled blood at large-vessel occlusion can present as hyperintense signals on perfusion magnetic resonance imaging with 3-dimensional pseudo-continuous arterial spin labeling (proximal bright vessel sign). The purpose of this study was to clarify the difference between proximal bright vessel sign and susceptibility vessel sign in acute cardioembolic cerebral infarction. METHODS: Forty-two patients with cardioembolic cerebral infarction in the anterior circulation territory underwent magnetic resonance imaging including diffusion-weighted imaging, 3-dimensional pseudo-continuous arterial spin labeling perfusion magnetic resonance imaging, T2*-weighted imaging, and 3-dimensional time-of-flight magnetic resonance angiography using a 3-T magnetic resonance scanner. Visual assessments of proximal bright vessel sign and the susceptibility vessel sign were performed by consensus of 2 experienced neuroradiologists. The relationship between these signs and the occlusion site of magnetic resonance angiography was also investigated. RESULTS: Among 42 patients with cardioembolic cerebral infarction, 24 patients showed proximal bright vessel sign (57.1%) and 25 showed susceptibility vessel sign (59.5%). There were 19 cases of proximal bright vessel sign and susceptibility vessel sign-clear, 12 cases of proximal bright vessel sign and susceptibility vessel sign-unclear, and 11 mismatched cases. Four out of 6 patients with proximal bright vessel sign-unclear and susceptibility vessel sign-clear showed distal middle cerebral artery occlusion, and 2 out of 5 patients with proximal bright vessel sign-clear and susceptibility vessel sign-unclear showed no occlusion on magnetic resonance angiography. CONCLUSIONS: Proximal bright vessel sign is almost compatible with susceptibility vessel sign in patients with cardioembolic cerebral infarction.


Assuntos
Infarto Cerebral/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Embolia/complicações , Cardiopatias/complicações , Embolia Intracraniana/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Marcadores de Spin , Idoso , Idoso de 80 Anos ou mais , Infarto Cerebral/etiologia , Embolia/diagnóstico , Feminino , Cardiopatias/diagnóstico , Humanos , Interpretação de Imagem Assistida por Computador , Embolia Intracraniana/etiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
J Stroke Cerebrovasc Dis ; 26(7): 1535-1540, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28411037

RESUMO

BACKGROUND: The present study compared the applicability of computed tomography carotid plaque imaging using effective Z maps with gemstone spectral imaging (GSI) to that of magnetic resonance plaque imaging using 3-dimensional time-of-flight magnetic resonance angiography. METHODS: Stenosis was assessed in 18 carotid arteries of 14 patients, and the effective Z values of noncalcified carotid plaques were compared with the signal intensities of magnetic resonance angiography. RESULTS: It was found that the effective Z value of noncalcified carotid plaques was significantly lower for a group with high signal intensity than for a group with low signal intensity on magnetic resonance angiography (P <.001). The area under the receiver operating characteristic curve of effective Z values was .975, and the presumed cutoff effective Z value required to discriminate low and high intensity plaques on magnetic resonance angiography was 7.83. CONCLUSIONS: The effective Z value generated by GSI is a useful parameter to detect vulnerable carotid plaque materials.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Ressonância Magnética , Placa Aterosclerótica , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Meios de Contraste/administração & dosagem , Feminino , Humanos , Iohexol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
Neuroradiology ; 58(4): 351-6, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26779912

RESUMO

INTRODUCTION: Neuromelanin-sensitive MR imaging (MRI) can visualize neuromelanin-containing neurons in the substantia nigra pars compacta (SNc), and its utility has been reported in the evaluation of parkinsonism. Conversely, dopamine transporter imaging by (123)I-N-v-fluoropropyl-2b-carbomethoxy-3b-(4-iodophenyl)nortropane (FP-CIT) SPECT (DaTSCAN) is now an established method for evaluating parkinsonism, detecting presynaptic dopamine neuronal dysfunction. Both methods can assist differentiating neurodegenerative and other forms of parkinsonism. However, to our knowledge, there have been no studies concerning a correlation between the two methods. The aim of this study was to assess the utility of neuromelanin-sensitive MRI for diagnosing parkinsonism by examining a correlation with DaTSCAN. METHODS: Twenty-three patients with parkinsonism who underwent both neuromelanin-sensitive MRI and DaTSCAN were included. We measured the neuromelanin-positive SNc region volume by manually contouring the high signal intensity region of the SNc on neuromelanin-sensitive MRI and measured the specific binding ratio (SBR) on DaTSCAN. The asymmetry index of neuromelanin-positive SNc volume and the asymmetry index of SBR were also calculated. RESULTS: The volume of the neuromelanin-positive SNc region showed significant correlation with specific binding ratio (SBR) (right P < .001, ρ = 0.78, left P < .001, ρ = 0.86). The asymmetry index of neuromelanin-positive SNc volume also showed significant correlations with the asymmetry index of SBR (P < .001, ρ = 0.73). CONCLUSIONS: Decrease of the high signal intensity region of the SNc on neuromelanin-sensitive MRI would indicate damage to the nigrostriatal dopaminergic function as well as loss of dopaminergic neurons. We conclude that neuromelanin-sensitive MRI is a useful diagnostic biomarker for parkinsonism.


Assuntos
Imageamento por Ressonância Magnética , Melaninas/metabolismo , Transtornos Parkinsonianos/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Tropanos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos Parkinsonianos/metabolismo , Estudos Retrospectivos
14.
Acta Radiol ; 57(6): 742-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26253930

RESUMO

BACKGROUND: Multiple system atrophy, cerebellar type (MSA-C) sometimes shows asymmetrical findings on magnetic resonance imaging (MRI) and single photon emission computed tomography (SPECT). PURPOSE: To assess the frequency and clinical significance of asymmetrical MRI and (99m)Tc-ethyl cysteinate dimer perfusion (ECD) SPECT findings of the cerebellum, middle cerebellar peduncle (MCP), and pons in MSA-C patients. MATERIAL AND METHODS: We retrospectively reviewed 28 patients with MSA-C who underwent MRI and (99m)Tc-ECD SPECT and evaluated laterality of atrophy and signal changes on MRI, and laterality of perfusion on (99m)Tc-ECD SPECT transversely and longitudinally. RESULTS: Laterality was identified for 64%, 61%, and 21% of atrophy in the cerebellum, MCP, and pons, respectively, on MRI and for 71% of atrophy in the cerebellum on perfusion SPECT. Concerning comparisons between the latest MRI and SPECT findings, laterality of cerebellar/MCP atrophy on MRI and decreased cerebellar perfusion on SPECT was matched in 57%, mismatched in 11%, and absent in 25% of patients. On past images, MRI and SPECT showed matched laterality in 33%, mismatched laterality in 27%, no laterality in 13%, and SPECT precedent laterality in 27% of patients. Including the latest and past images, asymmetrical changes were observed in 75% of patients. We could not identify any correlation between laterality of image findings and cerebellar symptoms in most patients. CONCLUSION: Asymmetrical changes on MRI and perfusion SPECT are common in MSA-C patients. Perfusion SPECT is useful for diagnosing MSA-C in the early stages from a functional perspective.


Assuntos
Imageamento por Ressonância Magnética/métodos , Atrofia de Múltiplos Sistemas/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Cisteína/análogos & derivados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Estudos Retrospectivos
15.
Hepatology ; 59(4): 1591-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24214142

RESUMO

UNLABELLED: Autophagy can degrade aggregate-prone proteins, but excessive autophagy can have adverse effects. It would be beneficial if autophagy could be enhanced in a cell type-specific manner, but this has been difficult because the basic mechanism of autophagy is common. In the present study we found that inhibition of Niemann-Pick-type C1-like 1 (NPC1L1) by ezetimibe activates autophagy only in hepatocytes and small intestinal epithelia, but not in other cells. Ezetimibe induced accumulation of free cholesterol in the late endosome/lysosome and increased partitioning of a Ragulator component, LAMTOR1, in rafts. The latter change led to down-regulation of mammalian target of rapamycin (mTOR)C1 activity by decreasing mTOR recruitment to the late endosome/lysosome and activated autophagy. A primary effect of ezetimibe was found to be a decrease of free cholesterol in the plasma membrane, because all the results caused by ezetimibe were suppressed by supplementation of cholesterol as a methyl-ß-cyclodextrin complex. By enhancing autophagy in human primary hepatocytes with ezetimibe, insoluble mutant α1-antitrypsin Z was reduced significantly. CONCLUSION: Inhibition of NPC1L1 by ezetimibe activates autophagy in human hepatocytes by modulating cholesterol homeostasis. Ezetimibe may be used to ameliorate liver degeneration in α1-antitrypsin deficiency.


Assuntos
Autofagia/efeitos dos fármacos , Azetidinas/farmacologia , Hepatócitos/metabolismo , Proteínas de Membrana/antagonistas & inibidores , Mutação/genética , alfa 1-Antitripsina/genética , alfa 1-Antitripsina/metabolismo , Anticolesterolemiantes/farmacologia , Proteínas de Transporte/metabolismo , Linhagem Celular Tumoral , Colesterol/metabolismo , Ezetimiba , Hepatócitos/efeitos dos fármacos , Hepatócitos/patologia , Homeostase/efeitos dos fármacos , Humanos , Peptídeos e Proteínas de Sinalização Intracelular , Lisossomos/metabolismo , Microdomínios da Membrana/metabolismo , Proteínas de Membrana/efeitos dos fármacos , Proteínas de Membrana Transportadoras , Serina-Treonina Quinases TOR/metabolismo
16.
Neuroradiology ; 57(9): 909-15, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26070299

RESUMO

INTRODUCTION: Acute intramural hematoma resulting from cerebral artery dissection is usually visualized as a region of intermediate signal intensity on T1-weighted images (WI). This often causes problems with distinguishing acute atheromatous lesions from surrounding parenchyma and dissection. The present study aimed to determine whether or not R2* maps generated by the iterative decomposition of water and fat with echo asymmetry and least-squares estimation quantitation sequence (IDEAL IQ) can distinguish cerebral artery dissection more effectively than three-dimensional variable refocusing flip angle TSE T1WI (T1-CUBE) and T2*WI. METHODS: We reviewed data from nine patients with arterial dissection who were assessed by MR images including R2* maps, T2*WI, T1-CUBE, and 3D time-of-flight (TOF)-MRA. We visually assessed intramural hematomas in each patient as positive (clearly visible susceptibility effect reflecting intramural hematoma as hyperintensity on R2* map and hypointensity on T2*WI), negative (absent intramural hematoma), equivocal (difficult to distinguish between intramural hematoma and other paramagnetic substances such as veins, vessel wall calcification, or hemorrhage) and not evaluable (difficult to determine intramural hematoma due to susceptibility artifacts arising from skull base). RESULTS: Eight of nine patients were assessed during the acute phase. Lesions in all eight patients were positive for intramural hematoma corresponding to dissection sites on R2* maps, while two lesions were positive on T2*WI and three lesions showed high-intensity on T1-CUBE reflected intramural hematoma during the acute phase. CONCLUSION: R2* maps generated using IDEAL IQ can detect acute intramural hematoma associated with cerebral artery dissection more effectively than T2*WI and earlier than T1-CUBE.


Assuntos
Doenças Cerebelares/diagnóstico , Hemorragia Cerebral/diagnóstico , Hematoma/diagnóstico , Angiografia por Ressonância Magnética/métodos , Dissecação da Artéria Vertebral/diagnóstico , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
17.
Neuroradiology ; 57(9): 889-95, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25981057

RESUMO

INTRODUCTION: The present study compares the applicability of CT carotid plaque imaging using effective Z maps using gemstone spectral imaging (GSI) with that of conventional extracorporeal carotid ultrasound (US) and virtual histology-intravascular ultrasound (VH-IVUS). METHODS: We assessed stenosis in 31 carotid arteries of 30 patients. All patients underwent carotid CTA using GSI (Discovery CT750 HD, GE Healthcare). US and IVUS were examined with 25 and 8 vessels, respectively. We compared the effective Z values at noncalcified carotid plaque with the plaque components identified by US. We defined the plaque with low or low to iso intensity on US as vulnerable plaque and the plaque with iso, iso to high, and high intensity on US as stable plaque. We also performed visual assessment of color-coded effective Z maps in comparison with VH-IVUS and compared effective Z values with plaque components generated by VH-IVUS. RESULTS: The effective Z values at noncalcified carotid plaque were significantly lower for a group with vulnerable plaque, than with stable plaque on US (p < 0.05). Receiver operating curve analysis showed that AUC of effective Z values was 0.882 concerning the differentiation of these two groups on US. The interpretation of color-coded effective Z maps was essentially compatible with that of VH-IVUS for carotid plaque in all vessels. Effective Z values at noncalcified plaque showed significant negative correlation with the areas of fibro-fatty components generated by VH-IVUS (ρ = -0.874, p < 0.05). CONCLUSION: Effective Z maps generated by GSI can detect vulnerable carotid plaque materials.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Iohexol , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
18.
Acta Radiol ; 56(3): 329-38, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24558166

RESUMO

BACKGROUND: Moyamoya disease is a relatively rare cerebrovascular occlusive disorder. Several studies have reported cerebral microbleeds (CMBs) in moyamoya disease patients using T2*-weighted imaging (T2*WI) and/or susceptibility-weighted imaging (SWI). PURPOSE: To investigate the incidence, distribution patterns, and influencing factors of asymptomatic CMBs in patients with moyamoya disease. MATERIAL AND METHODS: Phase-sensitive imaging (PSI) was used to investigate 27 consecutive moyamoya disease patients with a 3-T magnetic resonance imaging system, then a meta-analysis of 245 patients (asymptomatic moyamoya disease, n = 23; ischemic moyamoya disease, n = 161; hemorrhagic moyamoya disease, n = 61) from four previous individual studies and our PSI study was performed. The meta-analysis was performed in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. Based on the clinical and radiological data, we divided the studies into different model groups to calculate the incidence of CMBs and discuss the distribution patterns of CMBs. RESULTS: Thirty-five asymptomatic CMBs were demonstrated in 14 moyamoya disease patients (51.9%) in our PSI study. Of these, 45.7% were located in the periventricular white matter. In the meta-analysis, the pooled incidence of asymptomatic CMBs in moyamoya disease was 46% (95% confidence interval [CI], 28.2-63.8%) on SWI or PSI and 29.6% (95% CI, 17.4-41.7%) on T2*WI. Statistical analysis showed that PSI or SWI offered better detection of CMBs in moyamoya disease than T2*WI, and 3-T T2*WI offered better detection than 1.5-T T2*WI. Furthermore, hemorrhagic onset-type moyamoya disease correlated with a high incidence of asymptomatic CMBs. CONCLUSION: PSI or SWI can detect CMBs better than T2*WI, and 3-T T2*WI. Hemorrhagic onset-type moyamoya disease seems to correlate with a high incidence of asymptomatic CMBs. The meta-analysis indicates that asymptomatic CMBs may be an important factor for hemorrhagic stroke risk. Long-term evaluation of CMBs using PSI or SWI may contribute to the management of moyamoya disease.


Assuntos
Hemorragia Cerebral/epidemiologia , Hemorragia Cerebral/patologia , Imageamento por Ressonância Magnética/métodos , Doença de Moyamoya/epidemiologia , Doença de Moyamoya/patologia , Adolescente , Adulto , Idoso , Encéfalo/irrigação sanguínea , Encéfalo/patologia , Criança , Comorbidade , Feminino , Humanos , Incidência , Masculino , Microcirculação , Pessoa de Meia-Idade , Fatores de Risco , Adulto Jovem
19.
Neuroradiology ; 56(11): 947-53, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25117504

RESUMO

INTRODUCTION: Follow-up CT angiography (CTA) is routinely performed for post-procedure management after carotid artery stenting (CAS). However, the stent lumen tends to be underestimated because of stent artifacts on CTA reconstructed with the filtered back projection (FBP) technique. We assessed the utility of new iterative reconstruction techniques, such as adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR), for CTA after CAS in comparison with FBP. METHODS: In a phantom study, we evaluated the differences among the three reconstruction techniques with regard to the relationship between the stent luminal diameter and the degree of underestimation of stent luminal diameter. In a clinical study, 34 patients who underwent follow-up CTA after CAS were included. We compared the stent luminal diameters among FBP, ASIR, and MBIR, and performed visual assessment of low attenuation area (LAA) in the stent lumen using a three-point scale. RESULTS: In the phantom study, stent luminal diameter was increasingly underestimated as luminal diameter became smaller in all CTA images. Stent luminal diameter was larger with MBIR than with the other reconstruction techniques. Similarly, in the clinical study, stent luminal diameter was larger with MBIR than with the other reconstruction techniques. LAA detectability scores of MBIR were greater than or equal to those of FBP and ASIR in all cases. CONCLUSION: MBIR improved the accuracy of assessment of stent luminal diameter and LAA detectability in the stent lumen when compared with FBP and ASIR. We conclude that MBIR is a useful reconstruction technique for CTA after CAS.


Assuntos
Angiografia , Artefatos , Estenose das Carótidas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Stents , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Estenose das Carótidas/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Imagens de Fantasmas , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA