Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Med Biol ; 69(5)2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38241716

RESUMO

Integrated-mode proton radiography leading to water equivalent thickness (WET) maps is an avenue of interest for motion management, patient positioning, andin vivorange verification. Radiographs can be obtained using a pencil beam scanning setup with a large 3D monolithic scintillator coupled with optical cameras. Established reconstruction methods either (1) involve a camera at the distal end of the scintillator, or (2) use a lateral view camera as a range telescope. Both approaches lead to limited image quality. The purpose of this work is to propose a third, novel reconstruction framework that exploits the 2D information provided by two lateral view cameras, to improve image quality achievable using lateral views. The three methods are first compared in a simulated Geant4 Monte Carlo framework using an extended cardiac torso (XCAT) phantom and a slanted edge. The proposed method with 2D lateral views is also compared with the range telescope approach using experimental data acquired with a plastic volumetric scintillator. Scanned phantoms include a Las Vegas (contrast), 9 tissue-substitute inserts (WET accuracy), and a paediatric head phantom. Resolution increases from 0.24 (distal) to 0.33 lp mm-1(proposed method) on the simulated slanted edge phantom, and the mean absolute error on WET maps of the XCAT phantom is reduced from 3.4 to 2.7 mm with the same methods. Experimental data from the proposed 2D lateral views indicate a 36% increase in contrast relative to the range telescope method. High WET accuracy is obtained, with a mean absolute error of 0.4 mm over 9 inserts. Results are presented for various pencil beam spacing ranging from 2 to 6 mm. This work illustrates that high quality proton radiographs can be obtained with clinical beam settings and the proposed reconstruction framework with 2D lateral views, with potential applications in adaptive proton therapy.


Assuntos
Terapia com Prótons , Prótons , Humanos , Criança , Algoritmos , Radiografia , Terapia com Prótons/métodos , Imagens de Fantasmas , Método de Monte Carlo
2.
Artigo em Inglês | MEDLINE | ID: mdl-38705488

RESUMO

PURPOSE: There is interest in using dual-energy computed tomography (DECT) to evaluate organ function before and after radiation therapy (RT). The purpose of this study (trial identifier: NCT04863027) is to assess longitudinal changes in lung perfusion using iodine maps derived from DECT in patients with lung cancer treated with conventional or stereotactic RT. METHODS AND MATERIALS: For 48 prospectively enrolled patients with lung cancer, a contrast-enhanced DECT using a dual-source CT simulator was acquired pretreatment and at 6 and 12 months posttreatment. Pulmonary functions tests (PFT) were obtained at baseline and at 6 and 12 months posttreatment. Iodine maps were extracted from the DECT images using a previously described 2-material decomposition framework. Longitudinal iodine maps were normalized using a reference region defined as all voxels with perfusion in the top 10% outside of the 5 Gy isodose volume. Normalized functional responses (NFR) were calculated for 3 dose ranges: <5, 5 to 20, and >20 Gy. Mixed model analysis was used to assess the correlation between dose metrics and NFR. Pearson correlation was used to assess if NFRs were correlated with PFT changes. RESULTS: Out of the 48 patients, 21 (44%) were treated with stereotactic body RT and 27 (56%) were treated with conventionally fractionated intensity-modulated RT. Thirty-one out of these 48 patients were ultimately included in data analysis. It was found that NFR is linearly correlated with dose (P < .001) for both groups. The number of months elapsed post-RT was also found to correlate with NFR (P = .029), although this correlation was not observed for the stereotactic body RT subgroup. The NFR was not found to correlate with PFT changes. CONCLUSIONS: DECT-derived iodine maps are a promising method for detailed anatomic evaluation of radiation effect on lung function, including potentially subclinical changes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA