Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Epilepsy Behav ; 150: 109572, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38070406

RESUMO

RATIONALE: Seizure induction techniques are used in the epilepsy monitoring unit (EMU) to increase diagnostic yield and reduce length of stay. There are insufficient data on the efficacy of alcohol as an induction technique. METHODS: We performed a retrospective cohort study using six years of EMU data at our institution. We compared cases who received alcohol for seizure induction to matched controls who did not. The groups were matched on the following variables: age, reason for admission, length of stay, number of antiseizure medications (ASM) at admission, whether ASMs were tapered during admission, and presence of interictal epileptiform discharges. We used both propensity score and exact matching strategies. We compared the likelihood of epileptic seizures and nonepileptic events in cases versus controls using Kaplan-Meier time-to-event analysis, as well as odds ratios for these outcomes occurring at any time during the admission. RESULTS: We analyzed 256 cases who received alcohol (median dose 2.5 standard drinks) and 256 propensity score-matched controls. Cases who received alcohol were no more likely than controls to have an epileptic seizure (X2(1) = 0.01, p = 0.93) or nonepileptic event (X2(1) = 2.1, p = 0.14) in the first 48 h after alcohol administration. For the admission overall, cases were no more likely to have an epileptic seizure (OR 0.89, 95 % CI 0.61-1.28, p = 0.58), nonepileptic event (OR 0.97, CI 0.62-1.53, p = 1.00), nor require rescue benzodiazepine (OR 0.63, CI 0.35-1.12, p = 0.15). Stratified analyses revealed no increased risk of epileptic seizure in any subgroups. Sensitivity analysis using exact matching showed that results were robust to matching strategy. CONCLUSIONS: Alcohol was not an effective induction technique in the EMU. This finding has implications for counseling patients with epilepsy about the risks of drinking alcohol in moderation in their daily lives.


Assuntos
Eletroencefalografia , Epilepsia , Humanos , Estudos Retrospectivos , Eletroencefalografia/métodos , Convulsões/psicologia , Epilepsia/complicações , Epilepsia/diagnóstico , Epilepsia/epidemiologia , Monitorização Fisiológica , Etanol/uso terapêutico
2.
Epilepsy Behav ; 158: 109928, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38959747

RESUMO

Temporal encephaloceles (TE) are an under-identified, potentially intervenable cause of epilepsy. This systematic review consolidates the current data to identify the major clinical, neuroimaging, and EEG features and surgical outcomes of epilepsy associated with TE. Literature searches were carried out using MEDLINE, Embase, PsycINFO, Scopus, and Cochrane Library databases from inception to December 7, 2023. Studies were included if they described clinical, neuroimaging, EEG, or surgical data in ≥5 patients with TE and epilepsy. Of 562 studies identified in the search, 24 met the eligibility criteria, reporting 423 unique patients with both epilepsy and TE. Compared to epilepsy patients without TE, those with TE had a higher mean age of seizure onset and were less likely to have a history of febrile seizures. Seizure semiologies were variable, but primarily mirrored temporal lobe onset patterns. Epilepsy patients with TE had a higher likelihood of having clinical or radiographic features of idiopathic intracranial hypertension (IIH) than those without. Brain MRI may show ipsilateral mesial temporal sclerosis (16 %). CT scans of the skull base usually revealed bony defects near the TE (90 %). Brain PET scans primarily showed ipsilateral temporal lobe hypometabolism (80 %), mostly in the anterior temporal lobe (67 %). Scalp EEG mostly lateralized ipsilateral to the implicated TE (92 % seizure onset) and localized to the temporal lobe (96 %). Intracranial EEG revealed seizure onset near the TE (11 of 12 cases including TE-adjacent electrodes) with variable timing of spread to the ipsilateral hippocampus. After surgical treatment of the TE, the rate of Engel I or ILAE 1 outcomes at one year was 75 % for lesionectomy, 85 % for anterior temporal lobectomy (ATL), and 80 % for ATL with amygdalohippocampectomy. Further studies are needed to better elucidate the relationship between IIH, TE, and epilepsy, improve the identification of TE, and optimize surgical interventions.

3.
Epilepsia ; 64(7): 1910-1924, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37150937

RESUMO

OBJECTIVE: Effective surgical treatment of drug-resistant epilepsy depends on accurate localization of the epileptogenic zone (EZ). High-frequency oscillations (HFOs) are potential biomarkers of the EZ. Previous research has shown that HFOs often occur within submillimeter areas of brain tissue and that the coarse spatial sampling of clinical intracranial electrode arrays may limit the accurate capture of HFO activity. In this study, we sought to characterize microscale HFO activity captured on thin, flexible microelectrocorticographic (µECoG) arrays, which provide high spatial resolution over large cortical surface areas. METHODS: We used novel liquid crystal polymer thin-film µECoG arrays (.76-1.72-mm intercontact spacing) to capture HFOs in eight intraoperative recordings from seven patients with epilepsy. We identified ripple (80-250 Hz) and fast ripple (250-600 Hz) HFOs using a common energy thresholding detection algorithm along with two stages of artifact rejection. We visualized microscale subregions of HFO activity using spatial maps of HFO rate, signal-to-noise ratio, and mean peak frequency. We quantified the spatial extent of HFO events by measuring covariance between detected HFOs and surrounding activity. We also compared HFO detection rates on microcontacts to simulated macrocontacts by spatially averaging data. RESULTS: We found visually delineable subregions of elevated HFO activity within each µECoG recording. Forty-seven percent of HFOs occurred on single 200-µm-diameter recording contacts, with minimal high-frequency activity on surrounding contacts. Other HFO events occurred across multiple contacts simultaneously, with covarying activity most often limited to a .95-mm radius. Through spatial averaging, we estimated that macrocontacts with 2-3-mm diameter would only capture 44% of the HFOs detected in our µECoG recordings. SIGNIFICANCE: These results demonstrate that thin-film microcontact surface arrays with both highresolution and large coverage accurately capture microscale HFO activity and may improve the utility of HFOs to localize the EZ for treatment of drug-resistant epilepsy.


Assuntos
Ondas Encefálicas , Epilepsia Resistente a Medicamentos , Epilepsia , Humanos , Eletroencefalografia/métodos , Epilepsia/cirurgia , Epilepsia/diagnóstico , Encéfalo , Epilepsia Resistente a Medicamentos/diagnóstico , Epilepsia Resistente a Medicamentos/cirurgia
4.
Epilepsy Behav ; 127: 108529, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35016055

RESUMO

OBJECTIVE: To determine patient acceptability of benefit-risk trade-offs in selecting treatment options for drug-resistant mesial temporal lobe epilepsy, including open brain surgery, laser ablation (laser interstitial thermal therapy [LITT]), and continued medications. METHODS: A discrete-choice experiment survey was developed, consisting of 20 versions that were randomly assigned to respondents. Each version had 8 sets of constructed treatment alternatives, representing open brain surgery, LITT, or continued medical management. For each set, respondents indicated the treatment alternative they would choose first. Treatment alternatives were characterized by varying levels of chance of seizure freedom for at least 2 years (20-70%), risk of 30-day mortality (0-10%), and risk of neurological deficits (0-40%). Respondents' choices were analyzed using random-parameters logit models to quantify acceptable benefit-risk trade-offs. Preference heterogeneity was evaluated using latent-class analysis. RESULTS: The survey was administered to 2 cohorts of adult patients with drug-resistant epilepsy: a Duke cohort identified using diagnostic codes (n = 106) and a web-recruited panel with a self-reported physician diagnosis of drug-resistant epilepsy (n = 300). Based on mean preference weights, respondents who indicated a willingness to consider surgical intervention would accept a reduction in chance of seizure freedom from 70% to a minimum-acceptable benefit (MAB) of 23% if they could undergo LITT rather than open brain surgery. For a reduction in 30-day mortality from 1% to 0%, MAB was 52%. For a reduction in risk of long-term deficits from 10% to 0%, MAB was 39%. Latent-class analysis revealed additional choice patterns identifying respondent groups that more strongly favored continuing medications or undergoing surgery. CONCLUSION: Patients who are receptive to surgery would accept significantly lower treatment effectiveness to undergo a minimally invasive procedure relative to open brain surgery. They also were willing to accept lower treatment benefit to reduce risks of mortality or neurological deficits.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia do Lobo Temporal , Terapia a Laser , Adulto , Epilepsia Resistente a Medicamentos/cirurgia , Epilepsia do Lobo Temporal/cirurgia , Humanos , Terapia a Laser/métodos , Imageamento por Ressonância Magnética/métodos , Preferência do Paciente , Lobo Temporal/cirurgia , Resultado do Tratamento
5.
Epilepsia ; 61(11): 2415-2425, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33140403

RESUMO

OBJECTIVE: Midazolam nasal spray (MDZ-NS) is indicated for acute treatment of intermittent, stereotypic episodes of frequent seizure activity (ie, seizure clusters, acute repetitive seizures) that are distinct from a patient's usual seizure pattern, in patients 12 years of age and older with epilepsy. This trial evaluated safety and efficacy of MDZ-NS in patients with epilepsy who were admitted to the epilepsy monitoring unit for seizure characterization/presurgical evaluation. METHODS: In this randomized, double-blind, placebo-controlled phase 3 trial (P261-301; NCT01999777), eligible patients with ≥2 seizures in the 6-hour window preceding trial medication administration for whom treatment was appropriate based on investigator's judgment were randomized (1:1) to MDZ-NS 5 mg or placebo. Efficacy outcomes were proportion of patients seizure-free for 6 hours after treatment and time to first seizure within 6 hours. Safety and tolerability outcomes included treatment-emergent adverse events (TEAEs). RESULTS: Sixty-two patients were randomized (MDZ-NS n = 31; placebo n = 31), received trial medication, and completed the trial. A higher proportion of patients on MDZ-NS than placebo were seizure-free for 6 hours following treatment (54.8% vs 38.7%); however, the 16.1% difference was not statistically significant (P = .1972). The Kaplan-Meier curve of time to first seizure showed separation of both groups in favor of MDZ-NS from ~1.5 hours post-dose and throughout the 6-hour Treatment phase. Median time to first seizure was not estimable for MDZ-NS (>50% of patients had no seizure) and 3.9 hours for placebo (P = .1388). TEAEs with MDZ-NS were generally comparable to those with placebo. There were no deaths, serious TEAEs, or discontinuations due to TEAEs. SIGNIFICANCE: Although the observed treatment difference may be clinically meaningful, statistical significance was not demonstrated. Results suggest that MDZ-NS 5 mg may provide improvement over placebo, with efficacy maintained for ≥6 hours post-dose. MDZ-NS was well tolerated in this population.


Assuntos
Epilepsia/tratamento farmacológico , Midazolam/administração & dosagem , Monitorização Fisiológica/métodos , Sprays Nasais , Convulsões/tratamento farmacológico , Administração Intranasal , Adolescente , Adulto , Anticonvulsivantes/administração & dosagem , Anticonvulsivantes/efeitos adversos , Criança , Método Duplo-Cego , Epilepsia/diagnóstico , Epilepsia/fisiopatologia , Feminino , Moduladores GABAérgicos/administração & dosagem , Moduladores GABAérgicos/efeitos adversos , Cefaleia/induzido quimicamente , Humanos , Masculino , Midazolam/efeitos adversos , Pessoa de Meia-Idade , Convulsões/diagnóstico , Convulsões/fisiopatologia , Resultado do Tratamento , Adulto Jovem
6.
Ann Intern Med ; 171(2): 117-126, 2019 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-31261386

RESUMO

Background: Although self-management is recommended for persons with epilepsy, its optimal strategies and effects are uncertain. Purpose: To evaluate the components and efficacy of self-management interventions in the treatment of epilepsy in community-dwelling persons. Data Sources: English-language searches of MEDLINE, Cochrane Central Register of Controlled Trials, PsycINFO, and CINAHL in April 2018; the MEDLINE search was updated in March 2019. Study Selection: Randomized and nonrandomized comparative studies of self-management interventions for adults with epilepsy. Data Extraction: An investigator assessed study characteristics; intervention details, including 6 components of self-management; and outcomes, which were verified by a second reviewer. Risk of bias (ROB) was assessed independently by 2 investigators. Data Synthesis: 13 randomized and 2 nonrandomized studies (2514 patients) evaluated self-management interventions. Interventions were delivered primarily in group settings, used a median of 4 components, and followed 2 general strategies: 1 based on education and the other on psychosocial therapy. Education-based approaches improved self-management behaviors (standardized mean difference, 0.52 [95% CI, 0.0 to 1.04]), and psychosocial therapy-based approaches improved quality of life (mean difference, 6.64 [CI, 2.51 to 10.77]). Overall, self-management interventions did not reduce seizure rates, but 1 educational intervention decreased a composite of seizures, emergency department visits, and hospitalizations. Limitation: High ROB in most studies, incomplete intervention descriptions, and studies limited to English-language publications. Conclusion: There is limited evidence that self-management strategies modestly improve some patient outcomes that are important to persons with epilepsy. Overall, self-management research in epilepsy is limited by the range of interventions tested, the small number of studies using self-monitoring technology, and uncertainty about components and strategies associated with benefit. Primary Funding Source: U.S. Department of Veterans Affairs. (PROSPERO: CRD42018098604).


Assuntos
Epilepsia/terapia , Autogestão , Humanos
7.
Ann Neurol ; 83(6): 1174-1185, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29733464

RESUMO

OBJECTIVE: The optimal treatment of nonconvulsive seizures in critically ill patients is uncertain. We evaluated the comparative effectiveness of the antiseizure drugs lacosamide (LCM) and fosphenytoin (fPHT) in this population. METHODS: The TRENdS (Treatment of Recurrent Electrographic Nonconvulsive Seizures) study was a noninferiority, prospective, multicenter, randomized treatment trial of patients diagnosed with nonconvulsive seizures (NCSs) by continuous electroencephalography (cEEG). Treatment was randomized to intravenous (IV) LCM 400mg or IV fPHT 20mg phenytoin equivalents/kg. The primary endpoint was absence of electrographic seizures for 24 hours as determined by 1 blinded EEG reviewer. The frequency with which NCS control was achieved in each arm was compared, and the 90% confidence interval (CI) was determined. Noninferiority of LCM to fPHT was to be concluded if the lower bound of the CI for relative risk was >0.8. RESULTS: Seventy-four subjects were enrolled (37 LCM, 37 fPHT) between August 21, 2012 and December 20, 2013. The mean age was 63.6 years; 38 were women. Seizures were controlled in 19 of 30 (63.3%) subjects in the LCM arm and 16 of 32 (50%) subjects in the fPHT arm. LCM was noninferior to fPHT (p = 0.02), with a risk ratio of 1.27 (90% CI = 0.88-1.83). Treatment emergent adverse events (TEAEs) were similar in both arms, occurring in 9 of 35 (25.7%) LCM and 9 of 37 (24.3%) fPHT subjects (p = 1.0). INTERPRETATION: LCM was noninferior to fPHT in controlling NCS, and TEAEs were comparable. LCM can be considered an alternative to fPHT in the treatment of NCSs detected on cEEG. Ann Neurol 2018;83:1174-1185.


Assuntos
Anticonvulsivantes/uso terapêutico , Epilepsia Generalizada/tratamento farmacológico , Lacosamida/uso terapêutico , Fenitoína/análogos & derivados , Adulto , Idoso , Idoso de 80 Anos ou mais , Ondas Encefálicas/efeitos dos fármacos , Estudos Cross-Over , Eletroencefalografia , Epilepsia Generalizada/fisiopatologia , Feminino , Escala de Coma de Glasgow , Humanos , Masculino , Pessoa de Meia-Idade , Fenitoína/uso terapêutico , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento
8.
Neurocrit Care ; 31(2): 312-320, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30788707

RESUMO

BACKGROUND: Non-convulsive seizures (NCS) are a common occurrence in the neurologic intensive care unit (Neuro-ICU) and are associated with worse outcomes. Continuous electroencephalogram (cEEG) monitoring is necessary for the detection of NCS; however, delays in interpretation are a barrier to early treatment. Quantitative EEG (qEEG) calculates a time-compressed simplified visual display from raw EEG data. This study aims to evaluate the performance of Neuro-ICU nurses utilizing bedside, real-time qEEG interpretation for detecting recurrent NCS. METHODS: This is a prospective, single-institution study of patients admitted to the Duke Neuro-ICU between 2016 and 2018 who had NCS identified on traditional cEEG review. The accuracy of recurrent seizure detection on hourly qEEG review by bedside Neuro-ICU nurses was compared to the gold standard of cEEG interpretation by two board-certified neurophysiologists. The nurses first received brief qEEG training, individualized for their specific patient. The bedside qEEG display consisted of rhythmicity spectrogram (left and right hemispheres) and amplitude-integrated EEG (left and right hemispheres) in 1-h epochs. RESULTS: Twenty patients were included and 174 1-h qEEG blocks were analyzed. Forty-seven blocks contained seizures (27%). The sensitivity was 85.1% (95% CI 71.1-93.1%), and the specificity was 89.8% (82.8-94.2%) for the detection of seizures for each 1-h block when compared to interpretation of conventional cEEG by two neurophysiologists. The false positive rate was 0.1/h. Hemispheric seizures (> 4 unilateral EEG electrodes) were more likely to be correctly identified by nurses on qEEG than focal seizures (≤ 4 unilateral electrodes) (p = 0.03). CONCLUSIONS: After tailored training sessions, Neuro-ICU nurses demonstrated a good sensitivity for the interpretation of bedside real-time qEEG for the detection of recurrent NCS with a low false positive rate. qEEG is a promising tool that may be used by non-neurophysiologists and may lead to earlier detection of NCS.


Assuntos
Competência Clínica , Eletroencefalografia , Monitorização Fisiológica , Enfermeiras e Enfermeiros , Convulsões/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Enfermagem de Cuidados Críticos/educação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neurofisiologia , Enfermagem em Neurociência/educação , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
9.
Epilepsy Behav ; 66: 4-9, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27974275

RESUMO

OBJECTIVE: Drug-resistant epilepsy is a devastating disorder associated with diminished quality of life (QOL). Surgical resection leads to seizure freedom and improved QOL in many epilepsy patients, but not all individuals are candidates for resection. In these cases, neuromodulation-based therapies such as vagus nerve stimulation (VNS) are often used, but most VNS studies focus exclusively on reduction of seizure frequency. QOL changes and predictors with VNS remain poorly understood. METHOD: Using the VNS Therapy Patient Outcome Registry, we examined 7 metrics related to QOL after VNS for epilepsy in over 5000 patients (including over 3000 with ≥12months follow-up), as subjectively assessed by treating physicians. Trends and predictors of QOL changes were examined and related to post-operative seizure outcome and likelihood of VNS generator replacement. RESULTS: After VNS therapy, physicians reported patient improvement in alertness (58-63%, range over follow-up period), post-ictal state (55-62%), cluster seizures (48-56%), mood change (43-49%), verbal communication (38-45%), school/professional achievements (29-39%), and memory (29-38%). Predictors of net QOL improvement included shorter time to implant (odds ratio [OR], 1.3; 95% confidence interval [CI], 1.1-1.6), generalized seizure type (OR, 1.2; 95% CI, 1.0-1.4), female gender (OR, 1.2; 95% CI, 1.0-1.4), and Caucasian ethnicity (OR, 1.3; 95% CI, 1.0-1.5). No significant trends were observed over time. Patients with net QOL improvement were more likely to have favorable seizure outcomes (chi square [χ2]=148.1, p<0.001) and more likely to undergo VNS generator replacement (χ2=68.9, p<0.001) than those with worsened/unchanged QOL. SIGNIFICANCE: VNS for drug-resistant epilepsy is associated with improvement on various QOL metrics subjectively rated by physicians. QOL improvement is associated with favorable seizure outcome and a higher likelihood of generator replacement, suggesting satisfaction with therapy. It is important to consider QOL metrics in neuromodulation for epilepsy, given the deleterious effects of seizures on patient QOL.


Assuntos
Epilepsia Resistente a Medicamentos/terapia , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Qualidade de Vida , Sistema de Registros/estatística & dados numéricos , Estimulação do Nervo Vago/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Epilepsia Resistente a Medicamentos/cirurgia , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Adulto Jovem
10.
Epilepsia ; 57(3): 376-85, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26799155

RESUMO

OBJECTIVE: Hippocampal sclerosis is the most common neuropathologic finding in cases of medically intractable mesial temporal lobe epilepsy. In this study, we analyzed the gene expression profiles of dentate granule cells of patients with mesial temporal lobe epilepsy with and without hippocampal sclerosis to show that next-generation sequencing methods can produce interpretable genomic data from RNA collected from small homogenous cell populations, and to shed light on the transcriptional changes associated with hippocampal sclerosis. METHODS: RNA was extracted, and complementary DNA (cDNA) was prepared and amplified from dentate granule cells that had been harvested by laser capture microdissection from surgically resected hippocampi from patients with mesial temporal lobe epilepsy with and without hippocampal sclerosis. Sequencing libraries were sequenced, and the resulting sequencing reads were aligned to the reference genome. Differential expression analysis was used to ascertain expression differences between patients with and without hippocampal sclerosis. RESULTS: Greater than 90% of the RNA-Seq reads aligned to the reference. There was high concordance between transcriptional profiles obtained for duplicate samples. Principal component analysis revealed that the presence or absence of hippocampal sclerosis was the main determinant of the variance within the data. Among the genes up-regulated in the hippocampal sclerosis samples, there was significant enrichment for genes involved in oxidative phosphorylation. SIGNIFICANCE: By analyzing the gene expression profiles of dentate granule cells from surgically resected hippocampal specimens from patients with mesial temporal lobe epilepsy with and without hippocampal sclerosis, we have demonstrated the utility of next-generation sequencing methods for producing biologically relevant results from small populations of homogeneous cells, and have provided insight on the transcriptional changes associated with this pathology.


Assuntos
Giro Denteado/metabolismo , Giro Denteado/patologia , Epilepsia do Lobo Temporal/diagnóstico , Epilepsia do Lobo Temporal/metabolismo , Análise de Componente Principal/métodos , Adulto , Giro Denteado/cirurgia , Eletroencefalografia/métodos , Epilepsia do Lobo Temporal/cirurgia , Feminino , Regulação da Expressão Gênica , Hipocampo/metabolismo , Hipocampo/patologia , Hipocampo/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose , Adulto Jovem
11.
Neuromodulation ; 19(2): 188-95, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26663671

RESUMO

OBJECTIVES: The Automatic Stimulation Mode (AutoStim) feature of the Model 106 Vagus Nerve Stimulation (VNS) Therapy System stimulates the left vagus nerve on detecting tachycardia. This study evaluates performance, safety of the AutoStim feature during a 3-5-day Epilepsy Monitoring Unit (EMU) stay and long- term clinical outcomes of the device stimulating in all modes. MATERIALS AND METHODS: The E-37 protocol (NCT01846741) was a prospective, unblinded, U.S. multisite study of the AspireSR(®) in subjects with drug-resistant partial onset seizures and history of ictal tachycardia. VNS Normal and Magnet Modes stimulation were present at all times except during the EMU stay. Outpatient visits at 3, 6, and 12 months tracked seizure frequency, severity, quality of life, and adverse events. RESULTS: Twenty implanted subjects (ages 21-69) experienced 89 seizures in the EMU. 28/38 (73.7%) of complex partial and secondarily generalized seizures exhibited ≥20% increase in heart rate change. 31/89 (34.8%) of seizures were treated by Automatic Stimulation on detection; 19/31 (61.3%) seizures ended during the stimulation with a median time from stimulation onset to seizure end of 35 sec. Mean duty cycle at six-months increased from 11% to 16%. At 12 months, quality of life and seizure severity scores improved, and responder rate was 50%. Common adverse events were dysphonia (n = 7), convulsion (n = 6), and oropharyngeal pain (n = 3). CONCLUSIONS: The Model 106 performed as intended in the study population, was well tolerated and associated with clinical improvement from baseline. The study design did not allow determination of which factors were responsible for improvements.


Assuntos
Epilepsia Resistente a Medicamentos/complicações , Epilepsias Parciais/complicações , Taquicardia/etiologia , Taquicardia/terapia , Estimulação do Nervo Vago/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Estimulação do Nervo Vago/instrumentação , Adulto Jovem
12.
Am J Hum Genet ; 91(2): 293-302, 2012 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-22863189

RESUMO

Idiopathic generalized epilepsy (IGE) is a complex disease with high heritability, but little is known about its genetic architecture. Rare copy-number variants have been found to explain nearly 3% of individuals with IGE; however, it remains unclear whether variants with moderate effect size and frequencies below what are reliably detected with genome-wide association studies contribute significantly to disease risk. In this study, we compare the exome sequences of 118 individuals with IGE and 242 controls of European ancestry by using next-generation sequencing. The exome-sequenced epilepsy cases include study subjects with two forms of IGE, including juvenile myoclonic epilepsy (n = 93) and absence epilepsy (n = 25). However, our discovery strategy did not assume common genetic control between the subtypes of IGE considered. In the sequence data, as expected, no variants were significantly associated with the IGE phenotype or more specific IGE diagnoses. We then selected 3,897 candidate epilepsy-susceptibility variants from the sequence data and genotyped them in a larger set of 878 individuals with IGE and 1,830 controls. Again, no variant achieved statistical significance. However, 1,935 variants were observed exclusively in cases either as heterozygous or homozygous genotypes. It is likely that this set of variants includes real risk factors. The lack of significant association evidence of single variants with disease in this two-stage approach emphasizes the high genetic heterogeneity of epilepsy disorders, suggests that the impact of any individual single-nucleotide variant in this disease is small, and indicates that gene-based approaches might be more successful for future sequencing studies of epilepsy predisposition.


Assuntos
Epilepsia Generalizada/genética , Exoma/genética , Predisposição Genética para Doença/genética , Sequência de Bases , Estudo de Associação Genômica Ampla , Genótipo , Humanos , Dados de Sequência Molecular , Alinhamento de Sequência , Análise de Sequência de DNA , População Branca/genética
14.
Epilepsy Behav ; 26(2): 203-6, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23305782

RESUMO

In order to identify the current practices of antiepileptic drug (AED) withdrawal after epilepsy surgery, a survey was administered to 204 adult and pediatric epileptologists. The responses from 58 epileptologists revealed wide variations regarding the time course and extent of AED withdrawal after successful epilepsy surgery. For most of the epileptologists, the likelihood of the surgery being successful is an important factor in determining whether or not AEDs are tapered. Most of the respondents started to taper AEDs more rapidly than suggested by previous reports. The majority of the epileptologists were able to stop all AEDs completely in a substantial number of patients. The most important factors considered when deciding to taper AEDs were the presence of ongoing auras and the occurrence of postoperative seizures prior to seizure remission. In the absence of data from well-designed prospective trials, such survey results can inform practice and, hopefully, aid in the design of future trials.


Assuntos
Anticonvulsivantes/uso terapêutico , Epilepsia/cirurgia , Padrões de Prática Médica , Suspensão de Tratamento , Epilepsia/tratamento farmacológico , Pesquisas sobre Atenção à Saúde , Humanos , Neurologia , Recidiva
15.
J Clin Neurophysiol ; 40(4): 339-349, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34482315

RESUMO

PURPOSE: Electrical stimulation through depth electrodes is used to map function and seizure onset during stereoelectroencephalography in patients undergoing evaluation for epilepsy surgery. Factors such as electrode design, location, and orientation are expected to impact effects of electrical stimulation. METHODS: We developed a steady-state finite element model of brain tissue including five layers (skull through white matter) and an implanted electrode to explore the impact of electrode design and placement on the activation of brain tissue by electrical stimulation. We calculated electric potentials, current densities, and volume of tissue activated ( Volact ) in response to constant current bipolar stimulation. We modeled two depth electrode designs (3.5- and 4.43-mm intercontact spacing) and varied electrode location and orientation. RESULTS: The electrode with greater intercontact spacing produced 8% to 23% larger Volact (1% to 16% considering only gray matter). Vertical displacement of the electrodes by half intercontact space increased Volact for upward displacement (6% to 83% for all brain tissue or -5% to 96% gray matter only) and decreased Volact (1% to 16% or 24% to 49% gray matter only) for downward displacement. Rotating the electrode in the tissue by 30° to 60° with respect to the vertical axis increased Volact by 30% to 90% (20%-48% gray matter only). CONCLUSIONS: Location and orientation of depth electrodes with respect to surrounding brain tissue have a large impact on the amount of tissue activated during electrical stimulation mapping in stereoelectroencephalography. Electrode design has an impact, although modest for commonly used designs. Individualization of stimulation intensity at each location remains critical, especially for avoiding false-negative results.


Assuntos
Mapeamento Encefálico , Encéfalo , Humanos , Estimulação Elétrica/métodos , Mapeamento Encefálico/métodos , Eletrodos , Eletrodos Implantados , Eletroencefalografia/métodos
16.
J Neural Eng ; 20(4)2023 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-37531949

RESUMO

Objective.Epilepsy is a neurological disorder characterized by recurrent seizures which vary widely in severity, from clinically silent to prolonged convulsions. Measuring severity is crucial for guiding therapy, particularly when complete control is not possible. Seizure diaries, the current standard for guiding therapy, are insensitive to the duration of events or the propagation of seizure activity across the brain. We present a quantitative seizure severity score that incorporates electroencephalography (EEG) and clinical data and demonstrate how it can guide epilepsy therapies.Approach.We collected intracranial EEG and clinical semiology data from 54 epilepsy patients who had 256 seizures during invasive, in-hospital presurgical evaluation. We applied an absolute slope algorithm to EEG recordings to identify seizing channels. From this data, we developed a seizure severity score that combines seizure duration, spread, and semiology using non-negative matrix factorization. For validation, we assessed its correlation with independent measures of epilepsy burden: seizure types, epilepsy duration, a pharmacokinetic model of medication load, and response to epilepsy surgery. We investigated the association between the seizure severity score and preictal network features.Main results.The seizure severity score augmented clinical classification by objectively delineating seizure duration and spread from recordings in available electrodes. Lower preictal medication loads were associated with higher seizure severity scores (p= 0.018, 97.5% confidence interval = [-1.242, -0.116]) and lower pre-surgical severity was associated with better surgical outcome (p= 0.042). In 85% of patients with multiple seizure types, greater preictal change from baseline was associated with higher severity.Significance.We present a quantitative measure of seizure severity that includes EEG and clinical features, validated on gold standard in-patient recordings. We provide a framework for extending our tool's utility to ambulatory EEG devices, for linking it to seizure semiology measured by wearable sensors, and as a tool to advance data-driven epilepsy care.


Assuntos
Epilepsia , Convulsões , Humanos , Convulsões/diagnóstico , Convulsões/terapia , Eletroencefalografia/métodos , Encéfalo/cirurgia , Eletrocorticografia
17.
Nat Commun ; 14(1): 6938, 2023 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-37932250

RESUMO

Patients suffering from debilitating neurodegenerative diseases often lose the ability to communicate, detrimentally affecting their quality of life. One solution to restore communication is to decode signals directly from the brain to enable neural speech prostheses. However, decoding has been limited by coarse neural recordings which inadequately capture the rich spatio-temporal structure of human brain signals. To resolve this limitation, we performed high-resolution, micro-electrocorticographic (µECoG) neural recordings during intra-operative speech production. We obtained neural signals with 57× higher spatial resolution and 48% higher signal-to-noise ratio compared to macro-ECoG and SEEG. This increased signal quality improved decoding by 35% compared to standard intracranial signals. Accurate decoding was dependent on the high-spatial resolution of the neural interface. Non-linear decoding models designed to utilize enhanced spatio-temporal neural information produced better results than linear techniques. We show that high-density µECoG can enable high-quality speech decoding for future neural speech prostheses.


Assuntos
Interfaces Cérebro-Computador , Fala , Humanos , Qualidade de Vida , Eletrocorticografia/métodos , Comunicação , Encéfalo
18.
J Neurosurg Case Lessons ; 3(23): CASE2295, 2022 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-35733825

RESUMO

BACKGROUND: Musicogenic epilepsy (ME) is a rare reflex epilepsy in which seizures are triggered by musical stimuli. Prior descriptions of ME have suggested localization to the nondominant temporal lobe, primarily in neocortex. Although resection has been described as a treatment for ME, other surgical modalities, such as laser ablation, may effectively disrupt seizure networks in ME while incurring comparatively lower risks of morbidity. The authors described the use of laser ablation to treat ME arising from the dominant mesial temporal structures. OBSERVATIONS: A 37-year-old woman with a 15-year history of drug-resistant ME was referred for surgical evaluation. Her seizures were triggered by specific musical content and involved behavioral arrest, repetitive swallowing motions, and word incomprehension. Diagnostic studies, including magnetic resonance imaging, single-photon emission computed tomography, magnetoencephalography, Wada testing, and stereoelectroencephalography, indicated seizure onset in the left (dominant) mesial temporal lobe. Laser interstitial thermal therapy was used to ablate the left mesial seizure onset zone. The patient was discharged on postoperative day two. At 18-month follow-up, she was seizure-free with no posttreatment neurological deficits. LESSONS: Laser ablation can be an effective treatment option for well-localized forms of ME, particularly when seizures originate from the dominant mesial temporal lobe.

19.
Physiol Meas ; 43(7)2022 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-35724654

RESUMO

Introduction. Epileptic seizures are common neurological disorders in the world, impacting 65 million people globally. Around 30% of patients with seizures suffer from refractory epilepsy, where seizures are not controlled by medications. The unpredictability of seizures makes it essential to have a continuous seizure monitoring system outside clinical settings for the purpose of minimizing patients' injuries and providing additional pathways for evaluation and treatment follow-up. Autonomic changes related to seizure events have been extensively studied and attempts made to apply them for seizure detection and prediction tasks. This scoping review aims to depict current research activities associated with the implementation of portable, wearable devices for seizure detection or prediction and inform future direction in continuous seizure tracking in ambulatory settings.Methods. Overall methodology framework includes 5 essential stages: research questions identification, relevant studies identification, selection of studies, data charting and summarizing the findings. A systematic searching strategy guided by systematic reviews and meta-analysis (PRISMA) was implemented to identify relevant records on two databases (PubMed, IEEE).Results. A total of 30 articles were included in our final analysis. Most of the studies were conducted off-line and employed consumer-graded wearable device. ACM is the dominant modality to be used in seizure detection, and widely deployed algorithms entail Support Vector Machine, Random Forest and threshold-based approach. The sensitivity ranged from 33.2% to 100% for single modality with a false alarm rate (FAR) ranging from 0.096 to 14.8 d-1. Multimodality has a sensitivity ranging from 51% to 100% with FAR ranging from 0.12 to 17.7 d-1.Conclusion. The overall performance in seizure detection system based on non-cerebral physiological signals is promising, especially for the detection of motor seizures and seizures accompanied with intense ictal autonomic changes.


Assuntos
Epilepsia , Dispositivos Eletrônicos Vestíveis , Algoritmos , Eletroencefalografia/métodos , Epilepsia/diagnóstico , Humanos , Convulsões/diagnóstico
20.
J Clin Neurophysiol ; 39(6): 474-480, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33181594

RESUMO

PURPOSE: Stereotactic EEG (SEEG) is being increasingly used in the intracranial evaluation of refractory epilepsy in the United States. In this study, the authors describe current practice of SEEG among National Association of Epilepsy Centers tertiary referral (level IV) centers. METHODS: Using the Survey Monkey platform, a survey was sent to all National Association of Epilepsy Centers level IV center directors. RESULTS: Of 192 centers polled, 104 directors completed the survey (54% response rate). Ninety-two percent currently perform SEEG. Of these, 55% of institutions reported that greater than 75% of their invasive electrode cases used SEEG. Stereotactic EEG was commonly used over subdural electrodes in cases of suspected mesial temporal lobe epilepsy (87%), nonlesional frontal lobe epilepsy (79%), insular epilepsy (100%), and individuals with prior epilepsy surgery (74%). Most centers (72%) used single-lead electrocardiogram monitoring concurrently with SEEG, but less than half used continuous pulse oximetry (47%) and only a few used respiratory belts (3%). Other significant intercenter technical variabilities included electrode nomenclature and choice of reference electrode. Patient care protocols varied among centers in patient-to-nurse ratio and allowed patient activity. Half of all centers had personnel who had prior experience in SEEG (50.5%); 20% of centers had adopted SEEG without any formal training. CONCLUSIONS: Stereotactic EEG has become the principal method for intracranial EEG monitoring in the majority of epilepsy surgery centers in the United States. Most report similar indications for use of SEEG, though significant variability exists in the utilization of concurrent cardiopulmonary monitoring as well as several technical and patient care practices. There is significant variability in level of background training in SEEG among practitioners. The study highlights the need for consensus statements and guidelines to benchmark SEEG practice and develop uniform standards in the United States.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia , Epilepsia Resistente a Medicamentos/cirurgia , Eletrodos Implantados , Eletroencefalografia/métodos , Epilepsia/diagnóstico , Epilepsia/cirurgia , Humanos , Encaminhamento e Consulta , Técnicas Estereotáxicas , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA