Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Am J Surg ; 211(5): 854-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27016313

RESUMO

BACKGROUND: The combination of pentoxifylline (Trental) and vitamin E has been reported to reverse significant consequences of radiation after mastectomy with immediate reconstruction, such as severe capsular contracture or loss of implants. We questioned whether prophylactic use could prevent these consequences. METHODS: Thirty women with implants or tissue expanders after mastectomy that underwent adjuvant radiation were treated with Trental and vitamin E for 180 days. All subjects then entered a 12-month observational phase. RESULTS: Of the 26 evaluable subjects, 3 subjects required implant revisions. One due to malposition of the nonradiated breast and 2 were due to contracture (7.7%). There were no implant losses. CONCLUSIONS: The combination of Trental and vitamin E can prevent severe contracture and implant losses allowing for immediate reconstruction with implant or tissue expander even if radiation is planned after mastectomy.


Assuntos
Implante Mamário/efeitos adversos , Neoplasias da Mama/radioterapia , Contratura Capsular em Implantes/prevenção & controle , Mastectomia/métodos , Pentoxifilina/administração & dosagem , Vitamina E/administração & dosagem , Adulto , Implante Mamário/métodos , Implantes de Mama/efeitos adversos , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Estudos de Coortes , Quimioterapia Combinada , Feminino , Humanos , Pessoa de Meia-Idade , Período Pós-Operatório , Prognóstico , Estudos Prospectivos , Radioterapia Adjuvante , Medição de Risco , Resultado do Tratamento
2.
Am J Surg ; 207(5): 698-701; discussion 701, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24791629

RESUMO

BACKGROUND: Both MRI and breast-specific gamma imaging are tools for surgical planning in newly diagnosed breast cancer. Breast-specific gamma imaging (BSGI) is used less frequently although it is of similar utility and lower cost. We compared the diagnostic and cost efficacy of BSGI with MRI. METHODS: Retrospective review of 1,480 BSGIs was performed in a community breast health center, 539 had a new diagnosis of cancer, 75 patients having both MRI and BSGI performed within 2 months of each other. Institutional charges for BSGI ($850) and MRI ($3,381) were noted. RESULTS: BSGI had a sensitivity of 92%, specificity of 73%, positive predictive value of 78%, and negative predictive value of 90%. This compared favorably with MRI that had sensitivity of 89%, specificity 54%, positive predictive value 67%, and negative predictive value 83%. The accuracy of BSGI was higher at 82% vs MRI at 72%. Total cost of MRI imaging was $253,575 vs BSGI at $63,750. CONCLUSIONS: BSGI is a cost-effective and accurate imaging study for further evaluation of dense breast tissue and new diagnosis of cancer.


Assuntos
Neoplasias da Mama/diagnóstico , Raios gama , Preços Hospitalares/estatística & dados numéricos , Imageamento por Ressonância Magnética/economia , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Neoplasias da Mama/economia , Análise Custo-Benefício , Feminino , Humanos , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos/economia , Estudos Retrospectivos , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi/economia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA