Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Wilderness Environ Med ; 34(2): 135-142, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36804375

RESUMO

INTRODUCTION: Point-of-care ultrasound (POCUS) is utilized in austere environments because it is lightweight, durable, battery powered, and portable. In austere settings, weight and space constraints are limitations to carrying dedicated ultrasound gel. Few studies have assessed commonly carried liquids as gel alternatives. The study objective was to assess the suitability of common food and personal care products as ultrasound coupling agents compared with that of commercial gel. METHODS: A noninferiority study compared 9 products to commercial gel. Each substance was independently tested on 2 subjects by 2 sonographers covering 8 standardized ultrasound windows. Clips were recorded, blinded, and independently graded by 2 ultrasound fellowship-trained physicians on the ability to make clinical decisions and technical details, including contrast, resolution, and artifact. A 20% noninferiority margin was set, which correlates to levels considered to be of reliably sufficient quality by American College of Emergency Physicians' guidelines. The substances included water, soap, shampoo, olive oil, energy gel, maple syrup, hand sanitizer, sunscreen, and lotion. RESULTS: A total of 300 of 318 (94%) clips met the primary endpoint of adequacy to make a clinical decision. All media, except sunscreen, were noninferior to commercial gel in the ability to make a clinical decision (α=0.05). In terms of secondary outcomes, resolution, artifact, and contrast, all substances were noninferior to commercial gel (α=0.05). The sonographers concluded that all gel alternatives' usability performed similarly to commercial gel, with the exception of energy gel. CONCLUSIONS: Of the 9 substances tested, 8 were noninferior to commercial gels for clinical decisions. Our study indicates that several POCUS gel substitutes are serviceable to produce clinically adequate images.


Assuntos
Médicos , Protetores Solares , Humanos , Ultrassonografia/métodos , Géis , Sistemas Automatizados de Assistência Junto ao Leito
2.
J Ultrasound Med ; 34(8): 1473-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26206834

RESUMO

Over the past decade, point-of-care ultrasound has become a common tool used for both procedures and diagnosis. Developing high-fidelity phantoms is critical for training in new and novel point-of-care ultrasound applications. Detecting skull fractures on ultrasound imaging in the younger-than-2-year-old patient is an emerging area of point-of-care ultrasound research. Identifying a skull fracture on ultrasound imaging in this age group requires knowledge of the appearance and location of sutures to distinguish them from fractures. There are currently no commercially available pediatric skull fracture models. We outline a novel approach to building a cost-effective, simple, high-fidelity pediatric skull fracture phantom to meet a unique training requirement.


Assuntos
Pediatria/instrumentação , Imagens de Fantasmas , Fraturas Cranianas/diagnóstico por imagem , Crânio/diagnóstico por imagem , Ultrassonografia/instrumentação , Análise Custo-Benefício , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Lactente , Recém-Nascido , Masculino , Pediatria/economia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/economia , Ultrassonografia/métodos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA