Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Bioanalysis ; 16(11): 545-555, 2024 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-39088035

RESUMO

Aim: The purpose of this work was to determine the feasibility of supporting a clinical microdose study for PF-06882961 (danuglipron), an oral small molecule agonist of the GLP-1 receptor, by LC-MS/MS. Methodology: Statistical instrument parameter optimization using response surface methodology was employed to develop a LC-MS/MS method for the analyte, PF-06882961. Results: An LC-MS/MS method was developed and validated to support a proof of concept microdose pharmacokinetics preclinical study in monkeys, administered PF-06882961 (0.005 mg total, average dose = 0.0007 mg/kg) via intravenous bolus injection. Conclusion: The present study demonstrated the feasibility of analyzing human microdose plasma samples for PF-06882961 by LC-MS/MS, instead of accelerator mass spectrometry, thereby reducing cost and eliminating synthesis and exposure to 14C labeled material.


[Box: see text].


Assuntos
Receptor do Peptídeo Semelhante ao Glucagon 1 , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Humanos , Receptor do Peptídeo Semelhante ao Glucagon 1/agonistas , Receptor do Peptídeo Semelhante ao Glucagon 1/metabolismo , Cromatografia Líquida/métodos , Administração Oral , Animais , Relação Dose-Resposta a Droga , Espectrometria de Massa com Cromatografia Líquida
2.
AAPS J ; 26(5): 88, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39085624

RESUMO

Duplicate analysis has been a conventional practice in the industry for ligand-binding assays (LBA), particularly for plate-based platforms like Enzyme-linked immunosorbent assay (ELISA) and Meso Scale Discovery (MSD) assays. Recent whitepapers and guidance have opened a door to exploring the implementation of single-well (singlicate) analysis approach for LBAs. Although the bioanalytical industry has actively investigated the suitability of singlicate analysis, applications in supporting regulated LBA bioanalysis are limited. The primary reason for this limitation is the absence of appropriate strategy to facilitate the transition from duplicate to singlicate analysis. In this paper we present the first case study with our data-driven approach to implement singlicate analysis in a clinical pharmacokinetics (PK) plate based LBA assay with ISR data. The central aspect of this strategy is a head-to-head comparison with Precision and Accuracy assessment in both duplicate and singlicate formats as the initial stage of assay validation. Subsequently, statistical analysis is conducted to evaluate method variability in both precision and accuracy. The results of our study indicated that there was no impactful difference between duplicate vs singlicate, affirming the suitability of singlicate analysis for the remaining steps of PK assay validation. The validation results obtained through singlicate analysis demonstrated acceptable assay performance characteristics across all validation parameters, aligning with regulatory guidance. The validated PK assay in singlicate has been employed to support a Phase I study. The appropriateness of singlicate analyses is further supported by initial Incurred Sample Reanalysis (ISR) data in which 90.1% of ISR samples fall within the acceptable criteria.


Assuntos
Ensaio de Imunoadsorção Enzimática , Ligantes , Humanos , Reprodutibilidade dos Testes , Ensaio de Imunoadsorção Enzimática/métodos , Farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA