Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Radiologe ; 49(1): 73-84; quiz 85, 2009 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-18815765

RESUMO

Forensic radiology includes both clinical and postmortem forensic radiology. Clinical forensic radiology deals with imaging of healthy people from a legal point of view, such as for determining age or to prove and document injuries in victims of crime. Postmortem forensic radiology deals with the application of modern radiological methods in order to optimise post-mortem diagnosis. X-ray examination has for decades been routinely used in postmortem diagnosis. Newer developments include the application of postmortem computer tomography and magnetic resonance imaging; these are the methods with the greatest information potential but also with the greatest deviations from diagnostics in living persons. Application of radiological methods for securing evidence in criminal procedures is still in its infancy. Radiologists' technical understanding and forensic doctors' knowledge of postmortem changes in a corpse must be synergised.


Assuntos
Angiografia , Autopsia/legislação & jurisprudência , Autopsia/métodos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Adulto , Determinação da Idade pelo Esqueleto , Criança , Maus-Tratos Infantis/diagnóstico , Maus-Tratos Infantis/legislação & jurisprudência , Prova Pericial/legislação & jurisprudência , Alemanha , Humanos , Mudanças Depois da Morte , Sensibilidade e Especificidade , Ferimentos e Lesões/patologia
2.
J Clin Invest ; 101(12): 2862-8, 1998 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-9637720

RESUMO

Idiopathic ventricular tachycardia is a generic term that describes the various forms of ventricular arrhythmias that occur in patients without structural heart disease and in the absence of the long QT syndrome. Many of these tachycardias are focal in origin, localize to the right ventricular outflow tract (RVOT), terminate in response to beta blockers, verapamil, vagal maneuvers, and adenosine, and are thought to result from cAMP-mediated triggered activity. DNA was prepared from biopsy samples obtained from myocardial tissue from a patient with adenosine-insensitive idiopathic ventricular tachycardia arising from the RVOT. Genomic sequences of the inhibitory G protein Galphai2 were determined after amplification by PCR and subcloning. A point mutation (F200L) in the GTP binding domain of the inhibitory G protein Galphai2 was identified in a biopsy sample from the arrhythmogenic focus. This mutation was shown to increase intracellular cAMP concentration and inhibit suppression of cAMP by adenosine. No mutations were detected in Galphai2 sequences from myocardial tissue sampled from regions remote from the origin of tachycardia, or from peripheral lymphocytes. These findings suggest that somatic cell mutations in the cAMP-dependent signal transduction pathway occurring during myocardial development may be responsible for some forms of idiopathic ventricular tachycardia.


Assuntos
Proteínas de Ligação ao GTP/genética , Mutação , Taquicardia Ventricular/genética , Sequência de Aminoácidos , AMP Cíclico/fisiologia , Eletrofisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Dados de Sequência Molecular , Transdução de Sinais/genética , Taquicardia Ventricular/fisiopatologia
3.
Circulation ; 101(7): 777-83, 2000 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-10683352

RESUMO

BACKGROUND: Neurally mediated syncope has been associated with increased left ventricular (LV) fractional shortening (FS) during tilt testing, which is consistent with the hypothesis that the stimulation of LV mechanoreceptors leads to reflex hypotension and/or bradycardia. However, FS does not represent true LV contractility because of its dependence on afterload and preload. METHODS AND RESULTS: To elucidate the role of increased contractility in the mediation of neurally mediated syncope, we compared echocardiographic measures of LV performance corrected for end-systolic stress (ESS) in 21 patients (13 women and 8 men) with unexplained syncope who had either positive (n=10) or negative (n=11) responses to a tilt-table test. Two-dimensional echocardiographic LV imaging was performed at baseline and during the initial 5 minutes of upright tilt. In the supine position, both groups had similar LV end-diastolic volume indexes, stroke volumes, FS, circumferential ESS, and afterload-independent measures of LV performance (stress-corrected midwall and FS). However, after 5 minutes of upright tilt, patients who subsequently had a positive test had a lower stroke volume, lower stress-corrected midwall shortening, and endocardial FS. The tilt-positive group also had a greater fall in ESS and FS early during upright tilt. CONCLUSIONS: Reduced ESS, LV volume, and chamber function during initial upright tilt are associated with a subsequent positive tilt response in patients with unexplained syncope. These data suggest that if paradoxic activation of LV mechanoreceptors has a role in mediating neurally mediated syncope, it is not triggered by LV hypercontractility or increased systolic wall stress during the initial period of upright tilt.


Assuntos
Ecocardiografia , Sistema Nervoso/fisiopatologia , Síncope/diagnóstico por imagem , Síncope/fisiopatologia , Função Ventricular Esquerda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Teste da Mesa Inclinada
4.
Circulation ; 101(11): 1282-7, 2000 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-10725288

RESUMO

BACKGROUND: Clinical studies have shown that biphasic shocks are more effective than monophasic shocks for ventricular defibrillation. The purpose of this study was to compare the efficacy of a rectilinear biphasic waveform with a standard damped sine wave monophasic waveform for the transthoracic cardioversion of atrial fibrillation. METHODS AND RESULTS: In this prospective, randomized, multicenter trial, patients undergoing transthoracic cardioversion of atrial fibrillation were randomized to receive either damped sine wave monophasic or rectilinear biphasic shocks. Patients randomized to the monophasic protocol (n=77) received sequential shocks of 100, 200, 300, and 360 J. Patients randomized to the biphasic protocol (n=88) received sequential shocks of 70, 120, 150, and 170 J. First-shock efficacy with the 70-J biphasic waveform (60 of 88 patients, 68%) was significantly greater than that with the 100-J monophasic waveform (16 of 77 patients, 21%, P<0.0001), and it was achieved with 50% less delivered current (11+/-1 versus 22+/-4 A, P<0.0001). Similarly, the cumulative efficacy with the biphasic waveform (83 of 88 patients, 94%) was significantly greater than that with the monophasic waveform (61 of 77 patients, 79%; P=0.005). The following 3 variables were independently associated with successful cardioversion: use of a biphasic waveform (relative risk, 4.2; 95% confidence intervals, 1.3 to 13.9; P=0.02), transthoracic impedance (relative risk, 0.64 per 10-Omega increase in impedance; 95% confidence intervals, 0.46 to 0.90; P=0.005), and duration of atrial fibrillation (relative risk, 0.97 per 30 days of atrial fibrillation; 95% confidence intervals, 0.96 to 0.99; P=0.02). CONCLUSIONS: For transthoracic cardioversion of atrial fibrillation, rectilinear biphasic shocks have greater efficacy (and require less energy) than damped sine wave monophasic shocks.


Assuntos
Fibrilação Atrial/terapia , Cardioversão Elétrica/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tórax , Resultado do Tratamento
5.
J Am Coll Cardiol ; 27(5): 1098-105, 1996 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8609327

RESUMO

OBJECTIVES: This study sought to present evidence that fast atrioventricular (AV) node pathways with posterior exit sites may participate in typical AV node reentry. BACKGROUND: Catheter ablation of the slow AV node pathway in the posteroseptal right atrium is the preferred therapeutic approach in patients with AV node reentrant tachycardia. Despite the success achieved with this approach, electrophysiologic changes consistent with fast pathway ablation are occasionally observed. One potential explanation is the presence of an aberrant posterior fast pathway. METHODS: The location of fast and slow AV node pathways was determined by atrial activation mapping along the tricuspid valve annulus during tachycardia and was further confirmed by the effect of radiofrequency catheter ablation. RESULTS: Seven patients with AV node reentrant tachycardia had evidence of a posterior fast pathway near the coronary sinus os. Abolition of anterograde and retrograde fast pathway conduction followed radiofrequency ablation in the posteroseptal region in six patients. Consistent with fast pathway ablation, the AH interval increased from 70 +/- 24 to 195 +/- 35 ms (mean +/- SD), and tachycardia was no longer inducible. Selective slow pathway ablation was performed in one other patient with a posterior fast pathway. CONCLUSIONS: Functionally fast AV node pathways may be located in the posteroseptal right atrium, where slow pathway modification is performed. These data delineate the limitation of an anatomically guided slow pathway ablative approach and emphasize the importance of detailed mapping and localization of the retrograde fast pathway exit site before ablation. Failure to recognize the presence of posterior fast AV node pathways may account for sporadic examples of AV block, complicating posteroseptal ablation in patients with AV node reentry.


Assuntos
Ablação por Cateter/métodos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adulto , Idoso , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia
6.
J Am Coll Cardiol ; 30(1): 226-32, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9207646

RESUMO

OBJECTIVES: Our objective was to test fractal dimension (D), a measure of clustering of ventricular premature complexes (VPCs), on entry Holter recording as a predictor of future arrhythmic death and other-cause mortality in postinfarction patients in the Cardiac Arrhythmic Suppression Trial (CAST). BACKGROUND: Nonlinear dynamic methods of signal processing are being applied in medicine to provide new insights into apparently "chaotic" biologic events, including cardiac arrhythmias. One such application is the derivation of a fractal D to describe the clustering of VPCs in time. METHODS: Baseline Holter recordings were analyzed in blinded manner for 484 patients: 237 died or had a resuscitated cardiac arrest during follow-up, and 247 matched patients had no events. Fractal D, measured in four ways, was assessed as a predictor using Cox regression. RESULTS: One measure of D (high resolution D) was a significant univariate (relative hazard ratio 0.79 per SD change, p = 0.011) and multivariate (hazard ratio 0.75, p = 0.046) predictor of arrhythmic death but not other death (univariate p = 0.95, relative hazard 0.95, p = 0.66). Fractal D was greater (VPCs less clustered) in those patients free of arrhythmic events. On subgroup analysis, the predictive value of D resided in the randomized patient group (i.e., those who showed VPC suppression during initial antiarrhythmic drug titration and were randomized to blinded therapy with active drug or placebo) (multivariate hazard ratio 0.57, p = 0.001). CONCLUSIONS: A high resolution fractal D was predictive of arrhythmic (but not nonarrhythmic) death in a large postinfarction cohort. Further study of this new signal processing approach to ambulatory electrocardiographic recording will be of interest.


Assuntos
Arritmias Cardíacas/etiologia , Fractais , Infarto do Miocárdio/complicações , Complexos Ventriculares Prematuros/complicações , Idoso , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Fatores de Confusão Epidemiológicos , Morte Súbita Cardíaca/etiologia , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Razão de Chances , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Risco , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/fisiopatologia
7.
J Am Coll Cardiol ; 34(4): 1082-9, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10520794

RESUMO

OBJECTIVES: We evaluated the long-term outcome of patients with coronary artery disease and unexplained syncope who were treated with an electrophysiologic (EP)-guided approach. BACKGROUND: Electrophysiologic studies are frequently performed to evaluate unexplained syncope in patients with coronary artery disease. Patients with this profile who have inducible ventricular tachycardia are considered at high risk for sudden death and increased overall mortality, and therefore are often treated with an implantable cardioverter-defibrillator (ICD). The impact of this EP-guided strategy is unknown because there are no data comparing the long-term outcome of ICD recipients with that of noninducible patients. METHODS: We evaluated 67 consecutive patients with coronary artery disease and unexplained syncope. All patients were treated with an EP-guided approach that included ICD implantation in patients with inducible ventricular tachycardia. RESULTS: Electrophysiologic testing suggested a plausible diagnosis in 32 (48%) of these patients. Inducible monomorphic ventricular tachycardia was the most common abnormality. Despite frequent appropriate therapy with ICDs, the total mortality for patients with inducible monomorphic ventricular tachycardia was significantly higher than for noninducible patients. The respective one- and two-year survival rates were 94% and 84% in noninducible patients and 77% and 45% in inducible patients (p = 0.02). CONCLUSIONS: Electrophysiologic testing suggests an etiology for unexplained syncope in approximately 50% of patients and risk stratifies these patients with regard to long-term outcome. Patients who receive an ICD for the management of inducible ventricular tachycardia have a high incidence of spontaneous ventricular arrhythmias requiring ICD therapy. However, despite ICD implantation and frequent appropriate delivery of ICD therapies, patients with inducible ventricular tachycardia have a significantly worse prognosis than do those who are noninducible.


Assuntos
Doença das Coronárias/diagnóstico , Desfibriladores Implantáveis , Síncope/etiologia , Taquicardia Ventricular/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial , Doença das Coronárias/fisiopatologia , Doença das Coronárias/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Taxa de Sobrevida , Síncope/fisiopatologia , Síncope/prevenção & controle , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Resultado do Tratamento
8.
J Am Coll Cardiol ; 38(2): 371-6, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11499726

RESUMO

OBJECTIVES: This study was designed to determine the incidence and prognostic significance of inducible ventricular fibrillation (VF) in patients with coronary artery disease (CAD) and unexplained syncope. BACKGROUND: Current American College of Cardiology/American Heart Association practice guidelines recommend implantation of internal cardioverter-defibrillators (ICDs) in patients with unexplained syncope in whom either ventricular tachycardia (VT) or VF is inducible during electrophysiologic (EP) testing. Although the prognostic significance of inducible monomorphic VT is known, the significance of inducible VF remains undefined. METHODS: We evaluated 118 consecutive patients with CAD and unexplained syncope who underwent EP testing. Sustained monomorphic VT was inducible in 53 (45%) patients; in 20 (17%) patients, VF was the only inducible arrhythmia; and no sustained ventricular arrhythmia was inducible in the remaining 45 (38%) patients. The latter two groups of 65 (55%) patients make up the study population. RESULTS: There were 16 deaths among the study population during a follow-up period of 25.3 +/- 19.6 months. The overall one- and two-year survival in these patients was 89% and 81%, respectively. No significant difference in survival was observed between patients with and without inducible VF (80% power to detect a fourfold survival difference). CONCLUSIONS: In 17% of patients with CAD and unexplained syncope, VF is the only inducible ventricular arrhythmia. Within the limits of this pilot study, long-term follow-up of patients with and without inducible VF demonstrates no difference in survival between the two groups. Therefore, the practice of ICD implantation in patients with CAD, unexplained syncope and inducible VF, especially with triple ventricular extrastimuli, may merit reconsideration.


Assuntos
Doença das Coronárias/complicações , Síncope/complicações , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/mortalidade , Idoso , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Projetos Piloto , Prognóstico , Taxa de Sobrevida , Fibrilação Ventricular/complicações
9.
J Am Coll Cardiol ; 34(5): 1595-601, 1999 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-10551711

RESUMO

OBJECTIVES: We compared the efficacy of a novel rectilinear biphasic waveform, consisting of a constant current first phase, with a damped sine wave monophasic waveform during transthoracic defibrillation. BACKGROUND: Multiple studies have shown that for endocardial defibrillation, biphasic waveforms have a greater efficacy than monophasic waveforms. More recently, a 130-J truncated exponential biphasic waveform was shown to have equivalent efficacy to a 200-J damped sine wave monophasic waveform for transthoracic ventricular defibrillation. However, the optimal type of biphasic waveform is unknown. METHODS: In this prospective, randomized, multicenter trial, 184 patients who underwent ventricular defibrillation were randomized to receive a 200-J damped sine wave monophasic or 120-J rectilinear biphasic shock. RESULTS: First-shock efficacy of the biphasic waveform was significantly greater than that of the monophasic waveform (99% vs. 93%, p = 0.05) and was achieved with nearly 60% less delivered current (14 +/- 1 vs. 33 +/- 7 A, p < 0.0001). Although the efficacy of the biphasic and monophasic waveforms was comparable in patients with an impedance < 70 ohms (100% [biphasic] vs. 95% [monophasic], p = NS), the biphasic waveform was significantly more effective in patients with an impedance > or = 70 ohms (99% [biphasic] vs. 86% [monophasic], p = 0.02). CONCLUSIONS: This study demonstrates a superior efficacy of rectilinear biphasic shocks as compared with monophasic shocks for transthoracic ventricular defibrillation, particularly in patients with a high transthoracic impedance. More important, biphasic shocks defibrillated with nearly 60% less current. The combination of increased efficacy and decreased current requirements suggests that biphasic shocks as compared with monophasic shocks are advantageous for transthoracic ventricular defibrillation.


Assuntos
Arritmias Cardíacas/terapia , Cardioversão Elétrica/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
10.
Am J Cardiol ; 75(8): 591-5, 1995 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-7887384

RESUMO

The most frequently proposed mechanism for vasodepressor syncope is based on cardiac mechanoreceptor activation by augmented sympathetic tone. Because of the central role of the autonomic nervous system in this response, we hypothesized that the responses of the sympathetic and parasympathetic nervous systems (as assessed by analysis of heart rate variability) to orthostatic stress would differentiate patients with a positive from those with a negative tilt-table response. We therefore evaluated 28 patients undergoing tilt-table testing for presumed vasodepressor syncope. Based on 5-minute electrocardiographic samples obtained during the supine and upright phases (without isoproterenol infusion), we computed the mean RR interval, reflecting integrated cardiac sympathetic and parasympathetic tone, as well as the root-mean-square of successive differences of the RR intervals (RMSSD), a measure of high-frequency heart rate variability that is correlated with parasympathetic tone. Eleven patients had a negative and 17 a positive tilt response. There were no differences between the groups at baseline. In response to upright tilt, the mean RR decreased by a similar magnitude in both groups. In contrast, RMSSD decreased by 36% (p = 0.05) in response to upright tilt in patients with a negative response, but did not change significantly in patients with a positive tilt response. Absence of a decrease in RMSSD in response to orthostatic stress had 100% specificity and 41% sensitivity for predicting a positive test result. Thus, failure of withdrawal of parasympathetic tone (as assessed by RMSSD) during upright tilt predicts a positive tilt response.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Frequência Cardíaca/fisiologia , Sistema Nervoso Parassimpático/fisiopatologia , Síncope/fisiopatologia , Teste da Mesa Inclinada , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Síncope/diagnóstico
11.
Am J Cardiol ; 73(11): 774-9, 1994 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-8160615

RESUMO

Adenosine has been shown to reliably confirm the success of accessory pathway catheter ablation by producing transient atrioventricular (AV) block during atrial and ventricular pacing. This is due to the insensitivity of accessory pathway conduction to adenosine (with the rare exception of accessory pathways with decremental conduction properties). However, 4 of 204 consecutive patients who underwent successful accessory pathway ablation (as shown by adenosine-induced transient AV block) had recurrent AV reciprocating tachycardia involving a second, previously nonmanifest accessory pathway. In each case, the second accessory pathway was localized to a site disparate from the original pathway. No pathway showed decremental anterograde or retrograde conduction properties. In 2 patients, adenosine initially did not show the presence of the second concealed accessory pathway, because the refractory period of the accessory pathway was longer than the pacing cycle length used to assess ventriculoatrial conduction. Only when the refractory period of this second accessory pathway was shortened by infusion of isoproterenol did adenosine reveal the presence of the pathway during follow-up electrophysiologic study. In another patient, a non-decremental accessory pathway was shown to be sensitive to adenosine. In the remaining patient, the second accessory pathway may have been transiently injured during the initial study, thereby simulating adenosine sensitivity.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Adenosina , Nó Atrioventricular/cirurgia , Ablação por Cateter , Taquicardia/cirurgia , Adenosina/farmacologia , Adulto , Nó Atrioventricular/anormalidades , Nó Atrioventricular/efeitos dos fármacos , Eletrocardiografia , Feminino , Bloqueio Cardíaco/induzido quimicamente , Humanos , Isoproterenol/farmacologia , Masculino , Taquicardia/fisiopatologia , Resultado do Tratamento
12.
Am J Cardiol ; 78(9): 1055-7, 1996 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-8916491

RESUMO

Interobserver reproducibility is high for time domain and power spectral measures of heart rate variability, with greater reproducibility for low-frequency measures, and especially for the standard deviation of the 5-minute RR intervals over 24 hours, than for high-frequency measures. Overall interobserver variability of < 8% for these measures is largely (50% to 75%) explained by interobserver differences in annotation of supraventricular ectopy and sinus arrhythmia.


Assuntos
Complexos Atriais Prematuros , Frequência Cardíaca , Complexos Ventriculares Prematuros , Adulto , Idoso , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes
13.
Am J Cardiol ; 74(9): 906-11, 1994 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-7526677

RESUMO

Although reduced heart rate (HR) variability during sinus rhythm is associated with an adverse prognosis in a variety of clinical settings, the significance of measures of variability of the ventricular response in atrial fibrillation (AF) requires clarification. AF is common among patients with chronic severe mitral regurgitation (MR) and potentially limits the application of HR variability techniques in this population. Therefore, this study examined the physiologic correlates and prognostic significance of measures of HR variability in 21 patients with nonischemic causes of chronic severe MR who had chronic AF and underwent 24-hour ambulatory electrocardiography as part of a prospective study of the natural history of regurgitant valvular heart disease. Patients were followed for up to 9.1 years and end points of mortality and progression to mitral valve surgery were tabulated. Time- and frequency-domain measurements of high-, low-, and ultra-low-frequency HR variability were computed and compared with resting ventricular function by radionuclide cineangiography and outcome. All measures of HR variability were covariate (pair-wise r values between 0.48 and 0.99, all p values < 0.03), and none of the variables was significantly related to age, ventricular premature complex (VPC) density, or right or left ventricular ejection fraction. Reductions in time-domain measurements of ultra-low- and high-frequency HR variability were significant predictors of the combined risk of mortality or requirement for mitral valve surgery (p = 0.02 and p = 0.05, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Fibrilação Atrial/fisiopatologia , Frequência Cardíaca/fisiologia , Insuficiência da Valva Mitral/fisiopatologia , Função Ventricular/fisiologia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Complexos Cardíacos Prematuros/epidemiologia , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/epidemiologia , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo
14.
Am J Cardiol ; 79(11): 1482-7, 1997 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-9185637

RESUMO

We examined the relation of the standard deviation of the 5-minute mean RR intervals over 24 hours (SDANN), a measure of ultra-low frequency heart rate variability (HRV) (<0.0033 Hz), and other measures of HRV to clinical outcome events in 50 asymptomatic or minimally symptomatic patients with chronic severe aortic regurgitation (AR) who underwent ambulatory electrocardiography as part of a prospective study of the natural history of regurgitant valvular diseases. At entry, all patients were in sinus rhythm and had New York Heart Association functional class I or minimal II congestive heart failure, with left ventricular (LV) ejection fraction > or = 45% and LV end-diastolic dimension > or = 5.5 cm in women and > or = 5.9 cm in men. End points were defined as progression to aortic valve replacement (n = 19) or sudden cardiac death (n = 1) during the mean follow-up period of 8.1 +/- 3.8 years. With the median SDANN of 145 ms as a partition value, the average annual risk of end-point events in patients with low SDANN was significantly greater than the event rate in patients with high SDANN (11%/year vs 2%/year, p <0.0003). In multivariate analysis, reduced SDANN was associated with end-point events independent of LV function, LV end-systolic dimension, and symptom status (p = 0.001). We conclude that reduced ultra-low frequency HRV measured as SDANN is strongly related to progression to valve surgery in asymptomatic and minimally symptomatic patients with chronic AR.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Frequência Cardíaca , Adulto , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Doença Crônica , Cineangiografia , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Cintilografia , Volume Sistólico , Análise de Sobrevida
15.
Cardiol Clin ; 18(2): 265-91, vii, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10849873

RESUMO

Idiopathic ventricular tachycardia (VT) is characterized by two predominant forms. The most common form originates from the right ventricular outflow tract and presents as repetitive monomorphic VT or exercise-induced VT. The tachycardia is adenosine sensitive and is thought to be because of cAMP-mediated triggered activity. The other major form of idiopathic VT is owing to verapamil-sensitive intrafascicular re-entrant tachycardia, which most often originates in the region of the left posterior fascicle. Both forms of idiopathic VT can be readily treated with radiofrequency catheter ablation.


Assuntos
Coração/fisiologia , Taquicardia Ventricular , Ablação por Cateter , AMP Cíclico/metabolismo , Eletrocardiografia , Teste de Esforço , Sistema de Condução Cardíaco/metabolismo , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
16.
J Cardiovasc Pharmacol Ther ; 6(3): 237-45, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11584330

RESUMO

BACKGROUND: CVT-510, N-(3(R)-tetrahydrofuranyl)-6-aminopurine riboside, is a selective A(1)-adenosine receptor agonist with potential potent antiarrhythmic effects in tachycardias involving the atrioventricular (AV) node. This study, the first in humans, was designed to determine the effects of CVT-510 on AV nodal conduction and hemodynamics. METHODS AND RESULTS: Patients in sinus rhythm with normal AV nodal function at electrophysiologic study (n = 32) received a single intravenous bolus of CVT-510. AH and HV intervals were measured during sinus rhythm and during atrial pacing at 1, 5, 10, 15, 20, 30, 45, and 60 minutes after the bolus. Increasing doses of CVT-510 (0.3 to 10 microg/kg) caused a dose-dependent increase in the AH interval. At 1 minute, a dose of 10 microg/kg increased the AH interval during sinus rhythm from 93 +/- 23 msec to 114 +/- 37 msec, p = 0.01 and from 114 +/- 31 msec to 146 +/- 44 msec during atrial pacing at 600 msec, p = 0.003). The AH interval returned to baseline by 20 minutes. CVT-510 at doses of 0.3 to 10 microg/kg had no effect on sinus rate, HV interval, or systemic blood pressure, and was not associated with serious adverse effects. At doses of 15 and 30 microg/kg, CVT-510 produced transient second/third degree AV heart block in all four patients treated. One of these patients also had a prolonged sedative effect that was reversed with aminophylline. CONCLUSIONS: CVT-510 promptly prolongs AV nodal conduction and does not affect sinus rate or blood pressure. Selective stimulation of the A(1)-adenosine receptor by CVT-510 may be useful for immediate control of heart rate in atrial fibrillation/flutter and to convert paroxysmal supraventricular tachycardia to sinus rhythm, while avoiding vasodilatation mediated by the A(2)-adenosine receptor, as well as the vasodepressor and negative inotropic effects associated with beta-adrenergic receptor blockade and/or calcium channel blockers.


Assuntos
Adenosina/análogos & derivados , Adenosina/farmacologia , Nó Atrioventricular/efeitos dos fármacos , Furanos/farmacologia , Agonistas do Receptor Purinérgico P1 , Adenosina/efeitos adversos , Adenosina/sangue , Adulto , Idoso , Nó Atrioventricular/fisiologia , Pressão Sanguínea/efeitos dos fármacos , Pressão Sanguínea/fisiologia , Relação Dose-Resposta a Droga , Eletrocardiografia/efeitos dos fármacos , Feminino , Furanos/efeitos adversos , Furanos/sangue , Frequência Cardíaca/efeitos dos fármacos , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Ramos Subendocárdicos/efeitos dos fármacos , Ramos Subendocárdicos/fisiologia , Receptores Purinérgicos P1/fisiologia
17.
Ophthalmologe ; 97(12): 874-7, 2000 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-11227162

RESUMO

PURPOSE: Installation of airbags has reduced the rate of fatal injuries in severe automobile accidents. We report, however, severe ocular injuries in a minor accident as the result of an airbag. CASE REPORT: A front passenger suffered a blunt ocular trauma of her right eye during a collision. The approaching speed was about 31 km/h. The maximum change of velocity in direction of the impact was 19 km/h. Color traces were found on the upper rim of the airbag, apparently from the patient's eye shadow. RESULTS: In the emergency room, visual acuity was reduced to light perception. There was endothelial contusion, traumatic mydriasis, and lens subluxation. A sclopetarian retinopathy developed with a chorioretinal scar. Eight months after the accident visual acuity remained at light projection only. CONCLUSIONS: The eye injuries had very probably been caused by the deploying airbag. Improvements are a better geometry of deployment (e.g., tethered airbags), release at higher impacts only, and "intelligent systems" with additional sensors to avoid potentially hazardous airbag inflation in minor accidents.


Assuntos
Acidentes de Trânsito , Air Bags/efeitos adversos , Cegueira/etiologia , Traumatismos Oculares/etiologia , Ferimentos não Penetrantes/etiologia , Adulto , Traumatismos Oculares/complicações , Feminino , Humanos , Ferimentos não Penetrantes/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA