Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Neuromodulation ; 20(8): 745-752, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29076214

RESUMO

OBJECTIVES: Neural stimulation is well-accepted as an effective therapy for a wide range of neurological disorders. While the scale of clinical devices is relatively large, translational, and pilot clinical applications are underway for microelectrode-based systems. Microelectrodes have the advantage of stimulating a relatively small tissue volume which may improve selectivity of therapeutic stimuli. Current microelectrode technology is associated with chronic tissue response which limits utility of these devices for neural recording and stimulation. One approach for addressing the tissue response problem may be to reduce physical dimensions of the device. "Thinking small" is a trend for the electronics industry, and for implantable neural interfaces, the result may be a device that can evade the foreign body response. MATERIALS AND METHODS: This review paper surveys our current understanding pertaining to the relationship between implant size and tissue response and the state-of-the-art in ultrasmall microelectrodes. A comprehensive literature search was performed using PubMed, Web of Science (Clarivate Analytics), and Google Scholar. RESULTS: The literature review shows recent efforts to create microelectrodes that are extremely thin appear to reduce or even eliminate the chronic tissue response. With high charge capacity coatings, ultramicroelectrodes fabricated from emerging polymers, and amorphous silicon carbide appear promising for neurostimulation applications. CONCLUSION: We envision the emergence of robust and manufacturable ultramicroelectrodes that leverage advanced materials where the small cross-sectional geometry enables compliance within tissue. Nevertheless, future testing under in vivo conditions is particularly important for assessing the stability of thin film devices under chronic stimulation.


Assuntos
Eletrodos Implantados/tendências , Desenho de Equipamento/tendências , Microeletrodos/tendências , Neurônios/fisiologia , Animais , Eletrodos Implantados/normas , Desenho de Equipamento/normas , Humanos , Microeletrodos/normas
2.
Acta Biomater ; 111: 54-64, 2020 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-32428679

RESUMO

Intracortical microelectrode arrays (MEAs) are currently limited in their chronic functionality due partially to the foreign body response (FBR) that develops in regions immediately surrounding the implant (typically within 50-100 µm). Mechanically flexible, polymer-based substrates have recently been explored for MEAs as a way of minimizing the FBR caused by the chronic implantation. Nonetheless, the FBR degrades the ability of the device to record neural activity. We are motivated to develop approaches to deploy multiple recording sites away from the initial site of implantation into regions of tissue outside the FBR zone. Liquid Crystal Elastomers (LCEs) are responsive materials capable of programmable and reversible shape change. These hydrophobic materials are also non-cytotoxic and compatible with photolithography. As such, these responsive materials may be well suited to serve as substrates for smart, implantable electronics. This study explores the feasibility of LCE-based deployable intracortical MEAs. LCE intracortical probes are fabricated on a planar substrate and adopt a 3D shape after being released from the substrate. The LCE probes are then fixed in a planar configuration using polyethylene glycol (PEG). The PEG layer dissolves in physiological conditions, allowing the LCE probe to deploy post-implantation. Critically, we show that LCE intracortical probes will deploy within a brain-like agarose tissue phantom. We also show that deployment distance increases with MEA width. A finite element model was then developed to predict the deformed shape of the deployed probe when embedded in an elastic medium. Finally, LCE-based deployable intracortical MEAs were capable of maintaining electrochemical stability, recording extracellular signals from cortical neurons in vivo, and deploying recording sites greater than 100 µm from the insertion site in vivo. Taken together, these results suggest the feasibility of using LCEs to develop deployable intracortical MEAs. STATEMENT OF SIGNIFICANCE: Deployable MEAs are a recently developed class of neural interfaces that aim to shift the recording sites away from the region of insertion to minimize the negative effects of FBR on the recording performance of MEAs. In this study, we explore LCEs as a potential substrate for deployable MEAs. The novelty of this study lies in the systematic and programmable deployment offered by LCE-based intracortical MEAs. These results illustrate the feasibility and potential application of LCEs as a substrate for deployable intracortical MEAs.


Assuntos
Elastômeros , Cristais Líquidos , Eletrodos Implantados , Microeletrodos , Polímeros
3.
Micromachines (Basel) ; 11(6)2020 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-32630553

RESUMO

While intracortical microelectrode arrays (MEAs) may be useful in a variety of basic and clinical scenarios, their implementation is hindered by a variety of factors, many of which are related to the stiff material composition of the device. MEAs are often fabricated from high modulus materials such as silicon, leaving devices vulnerable to brittle fracture and thus complicating device fabrication and handling. For this reason, polymer-based devices are being heavily investigated; however, their implementation is often difficult due to mechanical instability that requires insertion aids during implantation. In this study, we design and fabricate intracortical MEAs from a shape memory polymer (SMP) substrate that remains stiff at room temperature but softens to 20 MPa after implantation, therefore allowing the device to be implanted without aids. We demonstrate chronic recordings and electrochemical measurements for 16 weeks in rat cortex and show that the devices are robust to physical deformation, therefore making them advantageous for surgical implementation.

4.
J Neural Eng ; 16(6): 064001, 2019 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-31480034

RESUMO

OBJECTIVE: Neural interfaces designed to stimulate or record electrical activity from peripheral nerves have applications ranging from the electrical modulation of nerve activity as a therapeutic option (e.g. epilepsy and depression) to the design of prosthetics. Currently, most peripheral nerve interfaces are either cuff-style devices that wrap around the target nerve or intraneural devices that are implanted within the nerve. While the latter option offers higher specificity and signal-to-noise ratio, penetrating devices can cause significant damage to the nerve due to the high degree of mechanical mismatch. Because of this, there is interest in developing penetrating devices fabricated from soft or softening materials (materials having a low elastic modulus). However, there is currently a lack of understanding regarding implantation forces required for successful insertion, which is a constraint for soft device design. Softer devices require robust designs to achieve a critical buckling force that is larger than forces experienced during device insertion. APPROACH: This study comprehensively assesses insertion force under different implantation conditions, with three variations for implantation speed, angle, and device tip angle, during insertion of silicon shanks in rat sciatic nerve. Additionally, we report compression moduli for rat sciatic nerve at different compression rates to inform computational modeling. MAIN RESULTS: We found that insertion speed and angle had significant effects on peak insertion force. We observed lower insertion forces (10-60 mN) when the device was implanted at higher angles relative to perpendicular insertion (80-125 mN). We also demonstrate the use of a nerve-stabilizing device to keep the nerve immobile during implantation. Additionally, we found that compression moduli were significantly different in small and large strain regions of the stress-strain curve with values between 1500-4500 Pa depending on compression rate. SIGNIFICANCE: This study provides information imperative to the design and successful implementation of soft penetrating peripheral nerve interfaces.


Assuntos
Módulo de Elasticidade/fisiologia , Desenho de Equipamento/métodos , Neuroestimuladores Implantáveis , Nervos Periféricos/fisiologia , Silício , Animais , Desenho de Equipamento/instrumentação , Masculino , Nervos Periféricos/cirurgia , Ratos , Ratos Long-Evans
5.
Polymers (Basel) ; 11(5)2019 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-31108911

RESUMO

Thiol-ene/acrylate-based shape memory polymers (SMPs) with tunable mechanical and thermomechanical properties are promising substrate materials for flexible electronics applications. These UV-curable polymer compositions can easily be polymerized onto pre-fabricated electronic components and can be molded into desired geometries to provide a shape-changing behavior or a tunable softness. Alternatively, SMPs may be prepared as a flat substrate, and electronic circuitry may be built directly on top by thin film processing technologies. Whichever way the final structure is produced, the operation of electronic circuits will be influenced by the electrical and mechanical properties of the underlying (and sometimes also encapsulating) SMP substrate. Here, we present electronic properties, such as permittivity and resistivity of a typical SMP composition that has a low glass transition temperature (between 40 and 60 °C dependent on the curing process) in different thermomechanical states of polymer. We fabricated parallel plate capacitors from a previously reported SMP composition (fully softening (FS)-SMP) using two different curing processes, and then we determined the electrical properties of relative permittivity and resistivity below and above the glass transition temperature. Our data shows that the curing process influenced the electrical permittivity, but not the electrical resistivity. Corona-Kelvin metrology evaluated the quality of the surface of FS-SMP spun on the wafer. Overall, FS-SMP demonstrates resistivity appropriate for use as an insulating material.

6.
Micromachines (Basel) ; 9(9)2018 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-30424376

RESUMO

Neural implants offer solutions for a variety of clinical issues. While commercially available devices can record neural signals for short time periods, they fail to do so chronically, partially due to the sustained tissue response around the device. Our objective was to assess the correlation between device stiffness, a function of both material modulus and cross-sectional area, and the severity of immune response. Meta-analysis data were derived from nine previously published studies which reported device material and geometric properties, as well as histological outcomes. Device bending stiffness was calculated by treating the device shank as a cantilevered beam. Immune response was quantified through analysis of immunohistological images from each study, specifically looking at fluorescent markers for neuronal nuclei and astrocytes, to assess neuronal dieback and gliosis. Results demonstrate that the severity of the immune response, within the first 50 µm of the device, is highly correlated with device stiffness, as opposed to device modulus or cross-sectional area independently. In general, commercially available devices are around two to three orders of magnitude higher in stiffness than devices which induced a minimal tissue response. These results have implications for future device designs aiming to decrease chronic tissue response and achieve increased long-term functionality.

7.
Micromachines (Basel) ; 9(10)2018 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-30424433

RESUMO

Current intracortical probe technology is limited in clinical implementation due to the short functional lifetime of implanted devices. Devices often fail several months to years post-implantation, likely due to the chronic immune response characterized by glial scarring and neuronal dieback. It has been demonstrated that this neuroinflammatory response is influenced by the mechanical mismatch between stiff devices and the soft brain tissue, spurring interest in the use of softer polymer materials for probe encapsulation. Here, we demonstrate stable recordings and electrochemical properties obtained from fully encapsulated shape memory polymer (SMP) intracortical electrodes implanted in the rat motor cortex for 13 weeks. SMPs are a class of material that exhibit modulus changes when exposed to specific conditions. The formulation used in these devices softens by an order of magnitude after implantation compared to its dry, room-temperature modulus of ~2 GPa.

8.
Sci Rep ; 8(1): 122, 2018 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-29317748

RESUMO

Mosquitos are among the deadliest insects on the planet due to their ability to transmit diseases like malaria through their bite. In order to bite, a mosquito must insert a set of micro-sized needles through the skin to reach vascular structures. The mosquito uses a combination of mechanisms including an insertion guide to enable it to bite and feed off of larger animals. Here, we report on a biomimetic strategy inspired by the mosquito insertion guide to enable the implantation of intracortical microelectrodes into the brain. Next generation microelectrode designs leveraging ultra-small dimensions and/or flexible materials offer the promise of increased performance, but present difficulties in reliable implantation. With the biomimetic guide in place, the rate of successful microprobe insertion increased from 37.5% to 100% due to the rise in the critical buckling force of the microprobes by 3.8-fold. The prototype guides presented here provide a reproducible method to augment the insertion of small, flexible devices into the brain. In the future, similar approaches may be considered and applied to the insertion of other difficult to implant medical devices.


Assuntos
Biomimética/métodos , Encéfalo , Culicidae , Eletrodos Implantados , Mordeduras e Picadas de Insetos , Microeletrodos , Algoritmos , Animais , Biomimética/instrumentação , Culicidae/fisiologia , Desenho de Equipamento , Fenômenos Mecânicos , Modelos Teóricos , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA