Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Ultrasound Med ; 40(3): 529-540, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32770709

RESUMO

OBJECTIVES: A remote quality assurance and improvement protocol for point-of-care obstetric ultrasound in low-resource areas was validated against the standard of care for obstetric ultrasound in the United States. METHODS: Compressed movie clip ultrasound images (obstetric sweep protocol) obtained by minimally trained personnel were read and interpreted by physicians with training in obstetric ultrasound. Observed findings were compared among readers and between each reader and the gold standard ultrasound scan report. Descriptive statistics were used for the analysis. RESULTS: The agreements among readers and between readers and the gold standard, for the anterior and posterior variables of the placental location were excellent, with Cohen κ values of 0.81 to 0.88 and 0.77 to 0.9, respectively. Cohen κ values were slight or slight/fair for other placental locations (left, right, fundal, and low), and the sensitivity and specificity ranged widely. The agreement among readers and between readers and the gold standard for fetal number comparisons was also excellent, with Cohen κ values ranging from 0.82 to 1, sensitivity from 0.83 to 1, and specificity from 0.99 to 1. The agreement among readers for fetal presentation comparisons, according to the Cohen κ, ranged from 0.79 to 0.85 and between readers and the gold standard had values of 0.43 to 0.49. For biometric parameters and estimated gestational age calculations based on these parameters, inter-reader reliability ranged from 0.79 to 0.85 for all parameters except femur length. Greater than 94% of obstetric sweep protocol ultrasound ages were within 7 days of the corresponding gold standard age. CONCLUSIONS: Movie clip ultrasound images provided adequate information for remote readers to reliably determine the placental location, fetal number, fetal presentation, and pregnancy dating.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Telemedicina , Biometria , Feminino , Humanos , Gravidez , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal
2.
J Trauma Acute Care Surg ; 74(3): 813-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23425740

RESUMO

BACKGROUND: Trauma patients imaged at community hospitals often receive duplicate computed tomographic (CT) imaging after transfer to regional trauma centers (RTCs). CT scanning is expensive, is resource intensive, and has acknowledged radiation risk to the patient. The objective of this study was to review and evaluate the frequency, indications, impact on patient management, as well as associated radiation and charges for duplicate CT imaging of trauma patients transferred to our RTC from outside hospitals (OSH). METHODS: Patients transferred to our RTC between September 2009 and August 2010 were evaluated prospectively. The OSH patients' charts and provider interviews were used to determine the reasons for repeated scans. The primary outcome was frequency of duplicate CT scan, defined as a repeated CT image of the same body part within 24 hours. The reason for duplicate imaging and impact on patient management was categorized. Radiation exposure and charges for duplicate scans were also determined. RESULTS: Of the 185 patients transferred to our facility, 177 were eligible. CT examinations at the OSH were performed on 137 patients (77%). A duplicate CT examination occurred in 38 patients (28%). The most common reason for duplicate CT scanning was lack of thin-section multiplanar data, on images sent via CD-ROM (37%). There was a change in management in 16 patients (42%). The patients with duplicate scanning received a median of 10.2 mSv (interquartile range, 6.6-15.7 mSv) of additional radiation, with a median charge of $409 (interquartile range, $307-$734). CONCLUSION: More than one third of duplicated scans performed on transferred trauma patients were potentially avoidable, primary owing to inadequate transfer of data from the OSH CT scan. The capacity of a single CD-ROM is insufficient to contain full imaging data from a trauma scan, and establishing direct links to imaging data from OSHs would decrease the number of repeated CT scans performed on transferred trauma patients. LEVEL OF EVIDENCE: Care management study, level III.


Assuntos
Transferência de Pacientes , Lesões por Radiação/prevenção & controle , Respiração , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Centros de Traumatologia/estatística & dados numéricos , Procedimentos Desnecessários , Ferimentos e Lesões/diagnóstico por imagem , Adulto , Feminino , Controle de Formulários e Registros , Hospitais Comunitários/estatística & dados numéricos , Humanos , Incidência , Escala de Gravidade do Ferimento , Masculino , Estudos Prospectivos , Doses de Radiação , Lesões por Radiação/epidemiologia , Lesões por Radiação/fisiopatologia , Estados Unidos/epidemiologia , Ferimentos e Lesões/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA