Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Methods Enzymol ; 698: 343-359, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38886038

RESUMO

Peptide drugs are a promising alternative to classical small molecule therapeutics with diverse applications, ranging from antibiotic resistant infection to prostate cancer. Oxytocin (OT) is a highly evolutionarily conserved peptide neurohormone and has been of interest for pharmaceutical use since 1909. Despite their increased safety profile relative to most small molecule drugs, peptides are poor candidates based on the pharmacokinetic (PK) properties from their peptide nature. Broad application of OT as a drug has been limited by these same PK issues. Several strategies have been proposed to overcome these limitations, among them glycosylation, which was used in combination with other sequence modifications to produce robust antinociception in mouse models, increased selectivity and potency at the OT receptor, and improved stability in rats.


Assuntos
Desenho de Fármacos , Glicosídeos , Ocitocina , Dor , Ocitocina/uso terapêutico , Ocitocina/farmacocinética , Animais , Ratos , Camundongos , Dor/tratamento farmacológico , Glicosídeos/química , Glicosídeos/farmacologia , Glicosídeos/uso terapêutico , Transtornos Relacionados ao Uso de Substâncias/tratamento farmacológico , Humanos , Analgésicos/farmacologia , Analgésicos/uso terapêutico , Glicosilação , Receptores de Ocitocina/metabolismo
2.
Diabetes Care ; 41(7): 1471-1477, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29752345

RESUMO

OBJECTIVE: Automated insulin delivery is the new standard for type 1 diabetes, but exercise-related hypoglycemia remains a challenge. Our aim was to determine whether a dual-hormone closed-loop system using wearable sensors to detect exercise and adjust dosing to reduce exercise-related hypoglycemia would outperform other forms of closed-loop and open-loop therapy. RESEARCH DESIGN AND METHODS: Participants underwent four arms in randomized order: dual-hormone, single-hormone, predictive low glucose suspend, and continuation of current care over 4 outpatient days. Each arm included three moderate-intensity aerobic exercise sessions. The two primary outcomes were percentage of time in hypoglycemia (<70 mg/dL) and in a target range (70-180 mg/dL) assessed across the entire study and from the start of the in-clinic exercise until the next meal. RESULTS: The analysis included 20 adults with type 1 diabetes who completed all arms. The mean time (SD) in hypoglycemia was the lowest with dual-hormone during the exercise period: 3.4% (4.5) vs. 8.3% (12.6) single-hormone (P = 0.009) vs. 7.6% (8.0) predictive low glucose suspend (P < 0.001) vs. 4.3% (6.8) current care where pre-exercise insulin adjustments were allowed (P = 0.49). Time in hypoglycemia was also the lowest with dual-hormone during the entire 4-day study: 1.3% (1.0) vs. 2.8% (1.7) single-hormone (P < 0.001) vs. 2.0% (1.5) predictive low glucose suspend (P = 0.04) vs. 3.1% (3.2) current care (P = 0.007). Time in range during the entire study was the highest with single-hormone: 74.3% (8.0) vs. 72.0% (10.8) dual-hormone (P = 0.44). CONCLUSIONS: The addition of glucagon delivery to a closed-loop system with automated exercise detection reduces hypoglycemia in physically active adults with type 1 diabetes.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Exercício Físico/fisiologia , Glucagon/administração & dosagem , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Dispositivos Eletrônicos Vestíveis , Adulto , Glicemia/análise , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Sistemas de Infusão de Insulina/normas , Masculino , Refeições , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Pâncreas Artificial , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA