Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-36988303

RESUMO

This study aims to investigate the morphological characteristics of the temporomandibular joint (TMJ) in the patients with anterior disc displacement with reduction (ADDwR) and the alterations after occlusal splint treatment. Thirty ADDwR patients and ten asymptomatic subjects were recruited. Thirteen parameters were adopted, along with automatic computation and presentation of the joint space to characterize the TMJ morphologies. Statistical results showed that morphological discrepancies between the patients and the asymptomatic subjects were ubiquitous. The adjustment of condyle position through occlusal splint treatment can result in joint spaces widening and has positive effects on mitigating the conditions of ADDwR.


Assuntos
Luxações Articulares , Transtornos da Articulação Temporomandibular , Humanos , Disco da Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/terapia , Imageamento por Ressonância Magnética/métodos , Luxações Articulares/terapia , Articulação Temporomandibular
2.
iScience ; 27(6): 110164, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38974471

RESUMO

This study introduces a novel virtual cursor control system designed to empower individuals with neuromuscular disabilities in the digital world. By combining eye-tracking with motor imagery (MI) in a hybrid brain-computer interface (BCI), the system enhances cursor control accuracy and simplicity. Real-time classification accuracy reaches 87.92% (peak of 93.33%), with cursor stability in the gazing state at 96.1%. Integrated into common operating systems, it enables tasks like text entry, online chatting, email, web surfing, and picture dragging, with an average text input rate of 53.2 characters per minute (CPM). This technology facilitates fundamental computing tasks for patients, fostering their integration into the online community and paving the way for future developments in BCI systems.

3.
Exp Ther Med ; 26(6): 560, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37941590

RESUMO

Severe spinal cord injury (SCI) affects the ability of functional standing and walking. As the locomotor central pattern generator (CPG) in the lumbosacral spinal cord can generate a regulatory signal for movement, it is feasible to activate CPG neural network using intra-spinal micro-stimulation (ISMS) to induce alternating patterns. The present study identified two special sites with the ability to activate the CPG neural network that are symmetrical about the posterior median sulcus in the lumbosacral spinal cord by ISMS in adult rats. A reversal of flexion and extension can occur in an attempt to generate a stepping movement of the bilateral hindlimb by either reversing the pulse polarity of the stimulus or changing the special site. Therefore, locomotor-like activity can be restored with monopolar intraspinal electrical stimulation on either special site. To verify the motor function regeneration of the paralyzed hindlimbs, a four-week locomotor training with ISMS applied to the special site in the SCI + ISMS group (n=12) was performed. Evaluations of motor function recovery using behavior, kinematics and physiological analyses, were used to assess hindlimb function and the results showed the stimulation at one special site can promote significant functional recovery of the bilateral hindlimbs (P<0.05). The present study suggested that motor function of paralyzed bilateral hindlimbs can be restored with monopolar ISMS.

4.
Comput Methods Programs Biomed ; 230: 107336, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36638552

RESUMO

OBJECTIVE: This study aims to investigate the biomechanical behavior and reveal the force transmission patterns of the human masticatory system through advanced three-dimensional finite element (FE) models. METHODS: The FE model was constructed according to the medical images of a healthy male adult. It contains full skull structures, detailed temporomandibular joints (TMJs) with discs, complete dentitions, masticatory muscles, and related ligaments. Several static bite scenarios were simulated to demonstrate the effects of bite positions and muscle force recruitments on the force transmission patterns. RESULTS: Molar occlusal surfaces are the primary force transmission region for clenching. Sensitivity analysis demonstrated that the stiffness of the bite substance would not alter the force transmission patterns but could affect the maximum contact stresses on the discs and the occlusal surfaces. During the unilateral clenching tasks, the high-stress region on the discal surfaces shifted ipsilaterally. The presence or absence of the molar cushions would significantly affect the biomechanical response of the masticatory system. SIGNIFICANCE: FE analysis is an effective way of investigating biomechanical responses involving complicated interactions. Enriching the static analysis of the masticatory system with a detailed model can help understand better how the forces were transmitted and the significance of TMJs during the clenching process.


Assuntos
Contração Muscular , Articulação Temporomandibular , Adulto , Humanos , Masculino , Contração Muscular/fisiologia , Articulação Temporomandibular/fisiologia , Músculos da Mastigação/fisiologia , Dente Molar/fisiologia , Crânio , Fenômenos Biomecânicos
5.
J Nanosci Nanotechnol ; 12(4): 2955-63, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22849052

RESUMO

Purification or separation of single-walled carbon nanotubes (SWCNTs) is one of the most fundamental steps before they are used for research and technological applications. Based on the difference of their physical and chemical properties, separation of carbon nanotubes (CNTs) can be categorized into three groups: length separation, metallic and semiconducting tubes separation and chirality separation. In this review, we first briefly review the purification of CNTs and then focus on the different methods for the separation of CNTs.

6.
Comput Methods Programs Biomed ; 202: 105995, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33592326

RESUMO

OBJECTIVE: This study aims to analyse the influence of different lining material, thickness and coverage on residual stress of class II molar restoration by the multilayer technique through the three-dimensional (3D) finite element (FE) method. The objective is to reveal the correlations between the base layer configurations and the residual stress distributions of the tooth. METHODS: A 3D reconstructed model of an extracted first molar was built through micro-CT images and a class II mesio-occlusal-distal cavity was prepared using computer-aided engineering (CAE) software. A bilayer technique was then applied, and 3D FE analyses were performed under polymerization contraction loading. Glass ionomer composites (Vitrebond and Ionosit) and flowable composite resin (Luxa Flow and Z350 Flowable Restorative) were used as lining materials. Moreover, several sensitivity analyses with dozens of hypothetical lining materials were conducted to provide definitive results. The thickness of the base layers was set to be distinct (0.5 mm or 1 mm) so as to reveal its effect on the stress alleviation. Various lining strategies with the liner covering different areas of the cavity walls (Closed Sandwich, Open Sandwich and Special Open Sandwich) were adopted to determine the effects of the base layers. RESULTS: Adoption of an appropriate liner could effectively reduce the polymerization shrinkage stress. The mechanical properties of the base layer can affect the residual stresses, basically a lower Young's modulus and lower Poisson's ratio (of lining material) result in better stress mitigation, therefore reducing the stress transmitted to the dentin. Increase of the lining thickness within a certain range could lead to a decrease in the probability of stress concentration formation. Lining strategies had the strongest influence on the stress distributions. Different lining coverage could cause various stress responses, and covering all cavity walls with the lining material had the optimal performance among all the simulations in this study. SIGNIFICANCE: The multilayer technique is an effective way to prolong the service life of resin composites restorations. A thorough evaluation of the sandwich technique through the FE method can provide a better understanding of the stress distributions of the restoration, and reveal its internal mechanisms.


Assuntos
Resinas Compostas , Dente Molar , Módulo de Elasticidade , Análise de Elementos Finitos , Teste de Materiais , Dente Molar/diagnóstico por imagem , Microtomografia por Raio-X
7.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 39(2): 203-208, 2021 Apr 01.
Artigo em Zh | MEDLINE | ID: mdl-33834676

RESUMO

OBJECTIVES: To investigate the differences in the temporomandibular joints (TMJs) between patients with anterior disc displacement with reduction (ADDwR) and asymptomatic subjects by using 3D morphometric measurements. METHODS: A total of 15 patients with ADDwR and 10 asymptomatic subjects were enrolled. Then, 3D models of the maxilla and mandible were reconstructed using MIMICS 20.0. Nine morphologic parameters of TMJs on both sides were measured on the 3D solid model. The differences in the parameters were analyzed between the patients and the asymptomatic subjects and between the left and right sides of each group. RESULTS: The horizontal and coronal condylar angles on the ipsilateral side of the patients were significantly greater than those of the asymptomatic subjects (P<0.01). Meanwhile, the sagittal ramus angle (SRA), medial joint space, lateral joint space, superior joint space, anterior joint space, and posterior joint space in the patients were significantly lower than those in the asymptomatic subjects (P<0.01). CONCLUSIONS: ADDwR will increase the condylar angles to be significantly greater than the normal level and decrease SRA and articular spaces to be significantly smaller than the normal level. The condyles will be displaced upward, closer to the fossa.


Assuntos
Luxações Articulares , Transtornos da Articulação Temporomandibular , Dente , Humanos , Imageamento por Ressonância Magnética , Mandíbula , Côndilo Mandibular , Maxila , Articulação Temporomandibular
8.
Med Biol Eng Comput ; 58(5): 1091-1097, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32162244

RESUMO

This study aims to analyse the stress distributions and initial displacements of teeth during the space closing stage through a three-dimensional finite element method. Computed tomography images of a patient were used to reconstruct the detailed teeth and alveolar bone, and brackets with stainless steel archwire were modelled according to the orthodontic prescriptions. The second premolars and first molars were chosen as the anchorages in the model 6-force, with buccal tubes attached to the second molars in the model 6-force-7, and the second molars as additional anchorages in the model 7-force. The results indicated that a movement of lingual lateral inclination occurred on the incisors during the retraction, and the frictional force between the teeth and the archwire significantly reduced the stress on the teeth and periodontal structures. Graphical abstract Malocclusion is one of the most common issue in dentistry with high prevalence and orthodontic treatment need. The extraction of first premolar teeth was normally needed at the beginning of the treatment. And the straight wire appliance together with the sliding mechanics was used for space closure at the end of the treatment. However, side effects like root resorption also found after the surgery. Biomechanically, the stress distributions and initial displacements of teeth during space closing stage might be a crucial factor contributed to those undesirable side effects. And different selections of anchorages might alter the biomechanical environment during the treatment. Thus, the purpose of the current study was to analyse the stress distributions and initial displacements, with the different anchorage selections, of teeth during space closing stage through 3D finite element method.


Assuntos
Fenômenos Biomecânicos/fisiologia , Dente Molar/fisiologia , Procedimentos de Ancoragem Ortodôntica , Humanos , Modelos Dentários , Periodonto/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA