1.
Sensors (Basel) ; 24(6)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38544105

RESUMO

This paper presents the description of the wavelength modulation spectroscopy (WMS) experiment, the parameters of which were established by use of the Artificial Intelligence (AI) algorithm. As a result, a significant improvement in the signal power to noise power ratio (SNR) was achieved, ranging from 1.6 to 6.5 times, depending on the harmonic. Typically, optimizing the operation conditions of WMS-based gas sensors is based on long-term simulations, complex mathematical model analysis, and iterative experimental trials. An innovative approach based on a biological-inspired genetic algorithm (GA) and custom-made electronics for laser control is proposed. The experimental setup was equipped with a 31.23 m Heriott multipass cell, software lock-in, and algorithms to control the modulation process of the quantum cascade laser (QCL) operating in the long-wavelength-infrared (LWIR) spectral range. The research results show that the applied evolutionary approach can efficiently and precisely explore a wide range of WMS parameter combinations, enabling researchers to dramatically reduce the time needed to identify optimal settings. It took only 300 s to test approximately 1.39 × 1032 combinations of parameters for key system components. Moreover, because the system is able to check all possible component settings, it is possible to unquestionably determine the operating conditions of WMS-based gas sensors for which the limit of detection (LOD) is the most favorable.

2.
Rev Sci Instrum ; 88(11): 115006, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29195373

RESUMO

The paper presents a portable breath sampling unit (BSU) for human breath analyzers. The developed unit can be used to probe air from the upper airway and alveolar for clinical and science studies. The BSU is able to operate as a patient interface device for most types of breath analyzers. Its main task is to separate and to collect the selected phases of the exhaled air. To monitor the so-called I, II, or III phase and to identify the airflow from the upper and lower parts of the human respiratory system, the unit performs measurements of the exhaled CO2 (ECO2) in the concentration range of 0%-20% (0-150 mm Hg). It can work in both on-line and off-line modes according to American Thoracic Society/European Respiratory Society standards. A Tedlar bag with a volume of 5 dm3 is mounted as a BSU sample container. This volume allows us to collect ca. 1-25 selected breath phases. At the user panel, each step of the unit operation is visualized by LED indicators. This helps us to regulate the natural breathing cycle of the patient. There is also an operator's panel to ensure monitoring and configuration setup of the unit parameters. The operation of the breath sampling unit was preliminarily verified using the gas chromatography/mass spectrometry (GC/MS) laboratory setup. At this setup, volatile organic compounds were extracted by solid phase microextraction. The tests were performed by the comparison of GC/MS signals from both exhaled nitric oxide and isoprene analyses for three breath phases. The functionality of the unit was proven because there was an observed increase in the signal level in the case of the III phase (approximately 40%). The described work made it possible to construct a prototype of a very efficient breath sampling unit dedicated to breath sample analyzers.


Assuntos
Testes Respiratórios/instrumentação , Cromatografia Gasosa-Espectrometria de Massas , Microextração em Fase Sólida , Butadienos/análise , Hemiterpenos/análise , Humanos , Óxido Nítrico/análise , Pentanos/análise , Compostos Orgânicos Voláteis/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA