3.
Phys Med ; 118: 103212, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38219559

RESUMO

PURPOSE: In Uganda, two-dimensional (2D) radiotherapy treatments have been in use since the establishment of radiotherapy in 1995. Preliminary investigations of treatment records in November 2019 showed evidence of gaps requiring urgent attention. The purpose of this study was to improve the safety of the treatments. METHODS: Records of 1164 patients treated in 1387 courses (1412 sites) on Cobalt-60 units were reviewed todetermine the frequency and dosimetric implications of events that occurred at different stepsof the radiotherapy process. The results were presented and discussed with the differentprofessionals for learning purposes. RESULTS: Most common dosimetric eventswere omission of block tray, bolus and couch transmission factors in time calculations, incorrect field sizes and depths, wrong beam weighting, independent calculations and prescription doses contributing 28.6 %, 10.1 %, 6.0 %,11.9 %, 10.1 %, 5.4 %, 4.8 % and 8.9 % to the 168 observed errors. Comparison of the calculated treatment doses with the prescribed doses showed that 88 % of the 1412 sites were treated with radiation doses within an accuracy of ± 5 %. However, an analysis of the evolution along the years demonstrated an improvement from 82.8 % in 2018 to 86.1 % in 2019, and 93.2 % in 2020. Most common procedural events were incomplete setup instructions and missing patient data in the record and verify system of the Co-60 units for 57 % and 60.1 % of the 1164 patients. CONCLUSIONS: Opportunities for improvement of safety in the delivery of radiotherapy treatments were identified. Learning from these past errors should raise awareness in the team leading to a safer treatments.


Assuntos
Radioterapia (Especialidade) , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Uganda , Radiometria
4.
Adv Radiat Oncol ; 9(2): 101335, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38405318

RESUMO

Purpose: Our purpose was to assess physics quality assurance (QA) practices in less resourced radiation therapy (RT) centers to improve quality of care. Methods and Materials: A preliminary study was conducted in 2020 of 13 select RT centers in 6 countries, and in 2021, our team conducted onsite visits to all the RT centers in Ghana, one of the countries from the initial survey. The RT centers included 1 private and 2 public institutions (denoted as Public-1 and Public-2). Follow-up surveys were sent to 17 medical physicists from the site visit. Questions centered on the topics of equipment, institutional practice, physics quality assurance, management, and safety practices. Qualitative and descriptive methods were used for data analysis. Questions regarding operational challenges (machine downtime, patient-related issues, power outages, and staffing) were asked on a 5-point Likert scale. Results: The preliminary survey from 2020 had a 92% response rate. One key result showed that for RT centers in lower gross national income per capita countries there was a direct correlation between QA needs and the gross national income per capita of the country. The needs identified included film/array detectors, independent dose calculation software, calibration of ion chambers, diodes, thermoluminiscence diodes (TLDs), phantoms for verification, Treatment Planning System (TPS) test phantoms, imaging test phantoms and film dosimeters, education, and training. For the post survey after the site visit in 2021, we received a 100% response rate. The private and the Public-1 institutions each have computed tomography simulators located in their RT center. The average daily patient external beam workload for each clinic on a linear accelerator was: private = 25, Public-1 = 55, Public-2 = 40. The Co-60 workload was: Public-1 = 45, Public-2 = 25 (there was no Co-60 at the private hospital). Public-1 and -2 lacked the equipment necessary to conform to best practices in Task Group reports (TG) 142 and 198. Public-2 reported significant operational challenges. Notably, Public-1 and -2 have peer review chart rounds, which are attended by clinical oncologists, medical physicists, physicians, and physics trainees. All 17 physicists who responded to the post site visit survey indicated they had a system of documenting, tracking, and trending patient-related safety incidents, but only 1 physicist reported using International Atomic Energy Agency Safety in Radiation Oncology. Conclusions: The preliminary study showed a direct correlation between QA needs and the development index of a country, and the follow-up survey examines operational and physics QA practices in the RT clinics in Ghana, one of the initial countries surveyed. This will form the basis of a planned continent-wide survey in Africa intended to spotlight QA practices in low- and middle-income countries, the challenges faced, and lessons learned to help understand the gaps and needs to support local physics QA and management programs. Audits during the site visit show education and training remain the most important needs in operating successful QA programs.

5.
Ecancermedicalscience ; 17: 1625, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38414955

RESUMO

Although many patients who receive definitive radiotherapy (RT) for localised prostate cancer (CaP) experience long-term disease-free survival and better quality of life, some also have biochemical progression during follow-up. Oftentimes this implies additional treatment for patients with the accompanying challenges of cumulative treatment side effects, inconvenience and financial toxicity. This study retrospectively assessed the clinicopathological characteristics and biochemical outcomes of patients treated for localised CaP with external beam radiotherapy (EBRT) between 2015 and 2020 at a major cancer treatment centre in Accra, Ghana. Patients' socio-demographic and clinical data were collected from their hospital records and analysed with the Statistical Package for Social Sciences version 26. Biochemical failure (BCF) was defined as an increase in the level of serum prostate-specific antigen (PSA) >2 ng/mL above the nadir after curative therapy based on the Phoenix definition. The mean age was 67.6 years (SD ± 6.2). The majority of the study participants (n = 79, 64.8%) had initial PSA >20 ng/mL, with the highest recorded value of 705 ng/mL. All the patients had biopsy-proven adenocarcinoma of the prostate gland. Some patients received 3-dimensional conformal radiotherapy (3DCRT) on a cobalt-60 teletherapy machine whereas others were treated with either 3DCRT or intensity-modulated radiotherapy (IMRT) on a 6 MV Linac. In all, 13.1% of the patients experienced BCF after receiving EBRT after an average follow-up of 31.3 months. This study demonstrated a low rate of BCF among patients treated with EBRT for localised CaP in Ghana. Strong prognostic factors of biochemical outcome demonstrated in this study were the percentage of cores positive, grade group, and risk stratification. Diarrhaea and desquamation experienced by treated CaP patients were exclusively attributable to EBRT. RT produced a complete resolution of symptoms in some of the patients.