Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Head Neck ; 42(10): 2779-2781, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32621399

RESUMO

Respiratory particle generation and dispersal during nasoendoscopy and swab testing is studied with high-speed video and laser light illumination. Video analysis reveals droplet formation in three manoeuvres during nasoendoscopy - sneezing, vocalization, and nasal decongestion spray. A capillary bridge of mucus can be seen when a nasoendoscope exits wet nares. No droplet formation is seen during oral and nasopharyngeal swab testing. We outline the following recommendations: pull the face mask down partially and keep the mouth covered, only allowing nasal access during nasoendoscopy; avoid nasal sprays if possible; if nasal sprays are used, procedurists should be in full personal protective equipment prior to using the spray; withdrawal of swabs and scopes should be performed in a slow and controlled fashion to reduce potential dispersion of droplets when the capillary bridge of mucus breaks up.


Assuntos
Teste para COVID-19 , Endoscopia , Muco , Cavidade Nasal , Fonação/fisiologia , Espirro/fisiologia , Administração Intranasal , Humanos , Controle de Infecções , Transmissão de Doença Infecciosa do Paciente para o Profissional , Sprays Nasais , Equipamento de Proteção Individual
2.
Int J Pediatr Otorhinolaryngol ; 76(2): 300-2, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22204960

RESUMO

We report a case of a deafened child with advanced labyrinthitis ossificans resulting from meningo-encephalitis. She received a cochlear implant in the right ear, following a drill-out procedure. Post-implant hearing outcomes were satisfactory initially, but deteriorated over time as a result of partial electrode migration. The child subsequently received a left auditory brainstem implantation with improvement of hearing outcomes. Post-operatively, a sub-dural hematoma developed not on the side of the operation but on the opposite side. Simultaneous use of the cochlear implant on one side and the acoustic brainstem on the other, aggravated the non-auditory side effects of the ABI and compromised its potential for optimal hearing results.


Assuntos
Implante Auditivo de Tronco Encefálico/métodos , Implante Coclear/métodos , Surdez/etiologia , Surdez/cirurgia , Meningoencefalite/complicações , Audiometria , Limiar Auditivo , Pré-Escolar , Terapia Combinada , Surdez/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Labirintite/diagnóstico por imagem , Labirintite/etiologia , Labirintite/cirurgia , Meningoencefalite/diagnóstico , Meningoencefalite/terapia , Cuidados Pós-Operatórios/métodos , Medição de Risco , Percepção da Fala , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA