Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 149(19): e1134-e1142, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38545775

RESUMO

Wearable biosensors (wearables) enable continual, noninvasive physiologic and behavioral monitoring at home for those with pediatric or congenital heart disease. Wearables allow patients to access their personal data and monitor their health. Despite substantial technologic advances in recent years, issues with hardware design, data analysis, and integration into the clinical workflow prevent wearables from reaching their potential in high-risk congenital heart disease populations. This science advisory reviews the use of wearables in patients with congenital heart disease, how to improve these technologies for clinicians and patients, and ethical and regulatory considerations. Challenges related to the use of wearables are common to every clinical setting, but specific topics for consideration in congenital heart disease are highlighted.


Assuntos
American Heart Association , Técnicas Biossensoriais , Cardiopatias Congênitas , Dispositivos Eletrônicos Vestíveis , Humanos , Cardiopatias Congênitas/diagnóstico , Técnicas Biossensoriais/instrumentação , Estados Unidos
2.
J Cardiovasc Magn Reson ; 24(1): 46, 2022 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-35922806

RESUMO

BACKGROUND: Maladaptive remodelling mechanisms occur in patients with repaired tetralogy of Fallot (rToF) resulting in a cycle of metabolic and structural changes. Biventricular shape analysis may indicate mechanisms associated with adverse events independent of pulmonary regurgitant volume index (PRVI). We aimed to determine novel remodelling patterns associated with adverse events in patients with rToF using shape and function analysis. METHODS: Biventricular shape and function were studied in 192 patients with rToF (median time from TOF repair to baseline evaluation 13.5 years). Linear discriminant analysis (LDA) and principal component analysis (PCA) were used to identify shape differences between patients with and without adverse events. Adverse events included death, arrhythmias, and cardiac arrest with median follow-up of 10 years. RESULTS: LDA and PCA showed that shape characteristics pertaining to adverse events included a more circular left ventricle (LV) (decreased eccentricity), dilated (increased sphericity) LV base, increased right ventricular (RV) apical sphericity, and decreased RV basal sphericity. Multivariate LDA showed that the optimal discriminative model included only RV apical ejection fraction and one PCA mode associated with a more circular and dilated LV base (AUC = 0.77). PRVI did not add value, and shape changes associated with increased PRVI were not predictive of adverse outcomes. CONCLUSION: Pathological remodelling patterns in patients with rToF are significantly associated with adverse events, independent of PRVI. Mechanisms related to incident events include LV basal dilation with a reduced RV apical ejection fraction.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Valor Preditivo dos Testes , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Tetralogia de Fallot/complicações , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Função Ventricular Direita
3.
J Pediatr ; 238: 26-32.e1, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34339728

RESUMO

OBJECTIVES: To characterize the clinical course and outcomes of children 12-18 years of age who developed probable myopericarditis after vaccination with the Pfizer-BioNTech (BNT162b2) coronavirus disease 2019 (COVID-19) messenger RNA (mRNA) vaccine. STUDY DESIGN: A cross-sectional study of 25 children, aged 12-18 years, diagnosed with probable myopericarditis after COVID-19 mRNA vaccination as per the Centers for Disease Control and Prevention criteria for myopericarditis at 8 US centers between May 10, 2021, and June 20, 2021. We retrospectively collected the following data: demographics, severe acute respiratory syndrome coronavirus 2 virus detection or serologic testing, clinical manifestations, laboratory test results, imaging study results, treatment, and time to resolutions of symptoms. RESULTS: Most (88%) cases followed the second dose of vaccine, and chest pain (100%) was the most common presenting symptom. Patients came to medical attention a median of 2 days (range, <1-20 days) after receipt of Pfizer mRNA COVID-19 vaccination. All adolescents had an elevated plasma troponin concentration. Echocardiographic abnormalities were infrequent, and 92% showed normal cardiac function at presentation. However, cardiac magnetic resonance imaging, obtained in 16 patients (64%), revealed that 15 (94%) had late gadolinium enhancement consistent with myopericarditis. Most were treated with ibuprofen or an equivalent nonsteroidal anti-inflammatory drug for symptomatic relief. One patient was given a corticosteroid orally after the initial administration of ibuprofen or an nonsteroidal anti-inflammatory drug; 2 patients also received intravenous immune globulin. Symptom resolution was observed within 7 days in all patients. CONCLUSIONS: Our data suggest that symptoms owing to myopericarditis after the mRNA COVID-19 vaccination tend to be mild and transient. Approximately two-thirds of patients underwent cardiac magnetic resonance imaging, which revealed evidence of myocardial inflammation despite a lack of echocardiographic abnormalities.


Assuntos
Vacinas contra COVID-19/genética , COVID-19/prevenção & controle , Imagem Cinética por Ressonância Magnética/métodos , Miocardite/etiologia , SARS-CoV-2/imunologia , Vacinação/efeitos adversos , Vacinas Sintéticas/efeitos adversos , Adolescente , COVID-19/epidemiologia , COVID-19/genética , Vacinas contra COVID-19/efeitos adversos , Criança , Estudos Transversais , Feminino , Humanos , Incidência , Masculino , Miocardite/diagnóstico , Miocardite/epidemiologia , Pandemias , Estudos Retrospectivos , Estados Unidos/epidemiologia , Vacinas de mRNA
4.
Pediatr Cardiol ; 42(6): 1275-1283, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33900430

RESUMO

Patients after surgical repair of Tetralogy of Fallot (rTOF) may suffer a decrease in left ventricular (LV) function. The aim of our study is to evaluate a novel method of assessing LV torsion in patients with rTOF, as an early indicator of systolic LV dysfunction. Motion tracking based on image registration regularized by the equilibrium gap principle, known as equilibrated warping, was employed to assess LV torsion. Seventy-six cases of rTOF and ten normal controls were included. The group of controls was assessed for reproducibility using both equilibrated warping and standard clinical tissue tracking software (CVI42, version 5.10.1, Calgary, Canada). Patients were dichotomized into two groups: normal vs. loss of torsion. Torsion by equilibrated warping was successfully obtained in 68 of 76 (89%) patients and 9 of 10 (90%) controls. For equilibrated warping, the intra- and interobserver coefficients of variation were 0.095 and 0.117, respectively, compared to 0.260 and 0.831 for tissue tracking by standard clinical software. The intra- and inter-observer intraclass correlation coefficients for equilibrated warping were 0.862 and 0.831, respectively, compared to 0.992 and 0.648 for tissue tracking. Loss of torsion was noted in 32 of the 68 (47%) patients with rTOF. There was no difference in LV or RV volumes or ejection fraction between these groups. The assessment of LV torsion by equilibrated warping is feasible and shows good reliability. Loss of torsion is common in patients with rTOF and its robust assessment might contribute into uncovering heart failure in an earlier stage.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Pré-Escolar , Humanos , Lactente , Complicações Pós-Operatórias/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
5.
Pediatr Cardiol ; 42(3): 578-589, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33394116

RESUMO

Ventricular contouring of cardiac magnetic resonance imaging is the gold standard for volumetric analysis for repaired tetralogy of Fallot (rTOF), but can be time-consuming and subject to variability. A convolutional neural network (CNN) ventricular contouring algorithm was developed to generate contours for mostly structural normal hearts. We aimed to improve this algorithm for use in rTOF and propose a more comprehensive method of evaluating algorithm performance. We evaluated the performance of a ventricular contouring CNN, that was trained on mostly structurally normal hearts, on rTOF patients. We then created an updated CNN by adding rTOF training cases and evaluated the new algorithm's performance generating contours for both the left and right ventricles (LV and RV) on new testing data. Algorithm performance was evaluated with spatial metrics (Dice Similarity Coefficient (DSC), Hausdorff distance, and average Hausdorff distance) and volumetric comparisons (e.g., differences in RV volumes). The original Mostly Structurally Normal (MSN) algorithm was better at contouring the LV than the RV in patients with rTOF. After retraining the algorithm, the new MSN + rTOF algorithm showed improvements for LV epicardial and RV endocardial contours on testing data to which it was naïve (N = 30; e.g., DSC 0.883 vs. 0.905 for LV epicardium at end diastole, p < 0.0001) and improvements in RV end-diastolic volumetrics (median %error 8.1 vs 11.4, p = 0.0022). Even with a small number of cases, CNN-based contouring for rTOF can be improved. This work should be extended to other forms of congenital heart disease with more extreme structural abnormalities. Aspects of this work have already been implemented in clinical practice, representing rapid clinical translation. The combined use of both spatial and volumetric comparisons yielded insights into algorithm errors.


Assuntos
Algoritmos , Ventrículos do Coração/diagnóstico por imagem , Redes Neurais de Computação , Tetralogia de Fallot/diagnóstico por imagem , Adulto , Estudos de Casos e Controles , Feminino , Ventrículos do Coração/anatomia & histologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino
6.
Cardiol Young ; 30(5): 656-662, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32290877

RESUMO

Novel commercially available software has enabled registration of both CT and MRI images to rapidly fuse with X-ray fluoroscopic imaging. We describe our initial experience performing cardiac catheterisations with the guidance of 3D imaging overlay using the VesselNavigator system (Philips Healthcare, Best, NL). A total of 33 patients with CHD were included in our study. Demographic, advanced imaging, and catheterisation data were collected between 1 December, 2016 and 31 January, 2019. We report successful use of this technology in both diagnostic and interventional cases such as placing stents and percutaneous valves, performing angioplasties, occlusion of collaterals, and guidance for lymphatic interventions. In addition, radiation exposure was markedly decreased when comparing our 10-15-year-old coarctation of the aorta stent angioplasty cohort to cases without the use of overlay technology and the most recently published national radiation dose benchmarks. No complications were encountered due to the application of overlay technology. 3D CT or MRI overlay for CHD intervention with rapid registration is feasible and aids decisions regarding access and planned angiographic angles. Operators found intraprocedural overlay fusion registration using placed vessel guidewires to be more accurate than attempts using bony structures.


Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Lactente , Recém-Nascido , Masculino , Imagem Multimodal , Estudos Retrospectivos , Software , Adulto Jovem
7.
J Cardiovasc Magn Reson ; 21(1): 67, 2019 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-31672164

RESUMO

BACKGROUND: Injury to vital structures posterior to the sternum is a complication associated with redo sternotomy in congenital cardiac surgery. The goal of our study was a novel evaluation of real-time cine cardiovascular magnetic resonance (CMR) to predict the presence of significant retrosternal adhesions of cardiac and vascular structures prior to redo sternotomy in patients with congenital heart disease. METHODS: Twenty-three patients who had prior congenital heart surgery via median sternotomy had comprehensive CMR studies prior to redo sternotomy. The real time cine (RTC) sequence that was used is an ungated balanced steady-state free precession (bSSFP) sequence using SENSitivity Encoding for acceleration with real-time reconstruction. Spontaneously breathing patients were instructed to take deep breaths during the acquisition whilst increased tidal volumes were delivered to mechanically ventilated patients. All patients underwent redo cardiac surgery subsequently and the presence and severity of retrosternal adhesions were noted at the time of the redo sternotomies. RESULTS: Median age at the time of CMR and operation were 5.5 years (range, 0.2-18.4y) and 6.1 years (range, 0.3-18.8y) respectively. There were 15 males and 8 females in the study group. Preoperative retrosternal adhesions were identified on RTC in 13 patients and confirmed in 11 (85%) at the time of surgery. In only 2 patients, no adhesions were identified on CMR but were found to have significant retrosternal adhesions at surgery; false positive rate 15% (CI 0.4-29.6%), false negative rate 20% (CI 3.7-36.4%). The total classification error of the real time cine sequence was 17% (CI 1.7-32.4%) with an overall accuracy of 83% (CI 67.7-98.4%). Standard breath-hold cine images correlated poorly with surgical findings and did not increase the diagnostic yield. CONCLUSIONS: RTC imaging can predict the presence of significant retrosternal adhesions and thus help in risk assessment prior to redo sternotomy. These findings complement the surgical planning and potentially reduce surgical complications .


Assuntos
Cardiopatias Congênitas/cirurgia , Imagem Cinética por Ressonância Magnética , Esternotomia/efeitos adversos , Doenças Torácicas/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Lactente , Masculino , Valor Preditivo dos Testes , Reoperação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Doenças Torácicas/etiologia , Aderências Teciduais
8.
J Cardiovasc Magn Reson ; 20(1): 76, 2018 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-30474554

RESUMO

BACKGROUND: Volumetric black-blood cardiovascular magnetic resonance (CMR) has been hampered by long scan times and flow sensitivity. The purpose of this study was to assess the feasibility of black-blood, electrocardiogram (ECG)-triggered and respiratory-navigated 3D fast spin echo (3D FSE) for the visualization of the whole heart and great vessels. METHODS: The implemented 3D FSE technique used slice-selective excitation and non-selective refocusing pulses with variable flip angles to achieve constant echo signal for tissue with T1 (880 ms) and T2 (40 ms) similar to the vessel wall. Ten healthy subjects and 21 patients with congenital heart disease (CHD) underwent 3D FSE and conventional 3D balanced steady-state free precession (bSSFP). The sequences were compared in terms of ability to perform segmental assessment, local signal-to-noise ratio (SNRl) and local contrast-to-noise ratio (CNRl). RESULTS: In both healthy subjects and patients with CHD, 3D FSE showed superior pulmonary vein but inferior coronary artery origin visualisation compared to 3D bSFFP. However, in patients with CHD the combination of 3D bSSFP and 3D FSE whole-heart imaging improves the success rate of cardiac morphological diagnosis to 100% compared to either technique in isolation (3D FSE, 23.8% success rate, 3D bSSFP, 5% success rate). In the healthy subjects SNRl for 3D bSSFP was greater than for 3D FSE (30.1 ± 7.3 vs 20.9 ± 5.3; P = 0.002) whereas the CNRl was comparable (17.3 ± 5.6 vs 17.4 ± 4.9; P = 0.91) between the two scans. CONCLUSIONS: The feasibility of 3D FSE for whole-heart black-blood CMR imaging has been demonstrated. Due to their high success rate for segmental assessment, the combination of 3D bSSFP and 3D FSE may be an attractive alternative to gadolinium contrast enhanced morphological CMR in patients with CHD.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Cardiopatias Congênitas/diagnóstico por imagem , Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Eletrocardiografia , Estudos de Viabilidade , Feminino , Coração/fisiopatologia , Cardiopatias Congênitas/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Circulação Pulmonar , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Adulto Jovem
9.
BMC Med Imaging ; 18(1): 36, 2018 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-30326847

RESUMO

BACKGROUND: Dual-phase 3-dimensional whole-heart acquisition allows simultaneous imaging during systole and diastole. Respiratory navigator gating and tracking of the diaphragm is used with limited accuracy. Prolonged scan time is common, and navigation often fails in patients with erratic breathing. Image-navigation (iNAV) tracks movement of the heart itself and is feasible in single phase whole heart imaging. To evaluate its diagnostic ability in congenital heart disease, we sought to apply iNAV to dual-phase sequencing. METHODS: Healthy volunteers and patients with congenital heart disease underwent dual-phase imaging using the conventional diaphragmatic-navigation (dNAV) and iNAV. Acquisition time was recorded and image quality assessed. Sharpness and length of the right coronary (RCA), left anterior descending (LAD), and circumflex (LCx) arteries were measured in both cardiac phases for both approaches. Qualitative and quantitative analyses were performed in a blinded and randomized fashion. RESULTS: In volunteers, there was no significant difference in vessel sharpness between approaches (p > 0.05). In patients, analysis showed equal vessel sharpness for LAD and RCA (p > 0.05). LCx sharpness was greater with dNAV (p < 0.05). Visualized length with iNAV was 0.5 ± 0.4 cm greater than that with dNAV for LCx in diastole (p < 0.05), 1.0 ± 0.3 cm greater than dNAV for LAD in diastole (p < 0.05), and 0.8 ± 0.7 cm greater than dNAV for RCA in systole (p < 0.05). Qualitative scores were similar between modalities (p = 0.71). Mean iNAV scan time was 5:18 ± 2:12 min shorter than mean dNAV scan time in volunteers (p = 0.0001) and 3:16 ± 1:12 min shorter in patients (p = 0.0001). CONCLUSIONS: Image quality of iNAV and dNAV was similar with better distal vessel visualization with iNAV. iNAV acquisition time was significantly shorter. Complete cardiac diagnosis was achieved. Shortened acquisition time will improve clinical applicability and patient comfort.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Distribuição Aleatória
10.
Cardiol Young ; 28(5): 719-724, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29506588

RESUMO

Previous studies have shown that cardiac MRI can be used to evaluate the suitability for infants to undergo the Glenn operation after having undergone the Norwood procedure. We sought to analyse our institutional data retrospectively to identify whether such a policy would be advisable in the current era. We reviewed patients who underwent the Norwood procedure between 1 January, 2006 and 1 January, 2016. All patients undergoing evaluation for the Glenn procedure received clinical evaluation, echocardiography, and cardiac catheterisation. A total of 179 patients were identified; 154 patients (86%) survived to undergo cardiac catheterisation as part of evaluation for the Glenn, and all who were evaluated did not eventually receive the Glenn. Using said algorithm, if cardiac MRI or CT were to be used to rationalise the use of catheterisation, 26 of 154 patients would have required catheterisation after cross-sectional imaging identified vascular obstruction; 83 of 154 patients would have received cross-sectional imaging only; and 45 of 154 would have had catheterisation only. All cases that required intervention, excluding aortopulmonary collaterals, and all cases that were not suitable to progress would have been correctly identified using clinical and echocardiographic criteria in addition to cardiac cross-sectional imaging to rationalise the use of catheterisation. Thus, in cases with acceptable clinical, echocardiographic, and angiographic findings, the additional haemodynamic information from catheterisation is rarely of use for decision-making, and interventions can largely be predicted by angiographic imaging modalities.


Assuntos
Cateterismo Cardíaco/métodos , Tomada de Decisões , Cardiopatias Congênitas/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Procedimentos de Norwood , Cuidados Pré-Operatórios/métodos , Ecocardiografia , Feminino , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Masculino , Estudos Retrospectivos
12.
J Cardiovasc Magn Reson ; 18(1): 74, 2016 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-27802802

RESUMO

BACKGROUND: Improved delineation of vascular structures is a common indication for cardiovascular magnetic resonance (CMR) in children and requires high spatial resolution. Currently, pre-contrast 3D, respiratory navigated, T2-prepared, fat saturated imaging with a bSSFP readout (3D bSSFP) is commonly used; however, these images can be limited by blood pool inhomogeneity and exaggeration of metal artifact. We compared image quality of pediatric vasculature obtained using standard 3D bSSFP to 3D, respiratory navigated, inversion recovery prepared imaging with a gradient echo readout (3D IR GRE) performed after administration of gadofosveset trisodium (GT), a blood pool contrast agent. METHODS: For both sequences, VCG triggering was used with acquisition during a quiescent period of the cardiac cycle. 3D bSSFP imaging was performed pre-contrast, and 3D IR GRE imaging was performed 5 min after GT administration. We devised a vascular imaging quality score (VIQS) with subscores for coronary arteries, pulmonary arteries and veins, blood pool homogeneity, and metal artifact. Scoring was performed on axial reconstructions of isotropic datasets by two independent readers and differences were adjudicated. Signal- and contrast-to-noise (SNR and CNR) calculations were performed on each dataset. RESULTS: Thirty-five patients had both 3D bSSFP and 3D IR GRE imaging performed. 3D IR GRE imaging showed improved overall vascular imaging compared to 3D bSSFP when comparing all-patient VIQS scores (n = 35, median 14 (IQR 11-15), vs 6 (4-10), p < 0.0001), and when analyzing the subset of patients with intrathoracic metal (n = 17, 16 (14-17) vs. 5 (2-9), p < 0.0001). 3D IR GRE showed significantly improved VIQS subscores for imaging the RCA, pulmonary arteries, pulmonary veins, and blood pool homogeneity. In addition, 3D IR GRE imaging showed reduced variability in both all-patient and metal VIQS scores compared to 3D bSSFP (p < 0.05). SNR and CNR were higher with 3D IR GRE in the left ventricle and left atrium, but not the pulmonary arteries. CONCLUSIONS: Respiratory navigated 3D IR GRE imaging after GT administration provides improved vascular CMR in pediatric patients compared to pre-contrast 3D bSSFP imaging, as well as improved imaging in patients with intrathoracic metal. It is an excellent alternative in this challenging patient population when high spatial resolution vascular imaging is needed.


Assuntos
Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Gadolínio/administração & dosagem , Cardiopatias Congênitas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Compostos Organometálicos/administração & dosagem , Artéria Pulmonar/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Mecânica Respiratória , Adolescente , Fatores Etários , Artefatos , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
13.
J Cardiovasc Magn Reson ; 18(1): 66, 2016 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-27716273

RESUMO

BACKGROUND: The use of gadolinium contrast agents in cardiovascular magnetic resonance is well-established and serves to improve both vascular imaging as well as enable late gadolinium enhancement (LGE) imaging for tissue characterization. Currently, gadofosveset trisodium, an intravascular contrast agent, combined with a three-dimensional inversion recovery balanced steady state free precession (3D IR bSSFP) sequence, is commonly used in pediatric cardiac imaging and yields excellent vascular imaging, but cannot be used for late gadolinium enhancement. Gadofosveset use remains limited in clinical practice, and manufacture was recently halted, thus an alternative is needed to allow 3D IR bSSFP and LGE in the same study. METHODS: Here we propose a protocol to give a bolus of 0.1 mL/kg = 0.1 mmol/kg gadobutrol (GADAVIST/GADOVIST) for time-resolved magnetic resonance angiography (MRA). Subsequently, 0.1 mmol/kg is diluted up to 5 or 7.5 mL with saline and then loaded into intravenous tubing connected to the patient. A 0.5 mL short bolus is infused, then a slow infusion is given at 0.02 or 0.03 mL/s. Image navigated (iNAV) 3D IR bSSFP imaging is initiated 45-60 s after the initiation of the infusion, with a total image acquisition time of ~5 min. If necessary, LGE imaging using phase sensitive inversion recovery reconstruction (PSIR) is performed at 10 min after the infusion is initiated. RESULTS: We have successfully performed the above protocol with good image quality on 10 patients with both time-resolved MRA and 3D IR bSSFP iNAV imaging. Our initial attempts to use pencil beam respiratory navigation failed due to signal labeling in the liver by the navigator. We have also performed 2D PSIR LGE successfully, with both LGE positive and LGE negative results. CONCLUSION: A bolus of gadobutrol, followed later by a slow infusion, allows time-resolved MRA, 3D IR bSSFP using the iNAV navigation technique, and LGE imaging, all in a single study with a single contrast agent.


Assuntos
Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Coração/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Compostos Organometálicos/administração & dosagem , Coração/fisiopatologia , Cardiopatias Congênitas/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Infusões Intravenosas , Injeções Intravenosas , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Tempo
15.
Cardiol Young ; 25(2): 355-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24472441

RESUMO

We present the case of a 29-year-old man with mutation-positive Duchenne muscular dystrophy and mutation-positive hypertrophic cardiomyopathy. His cardiac phenotype has characteristics of both disorders; he manifests sub-epicardial left ventricular free wall late gadolinium enhancement that is consistent with Duchenne cardiomyopathy, as well as asymmetric ventricular septal hypertrophy, hyperdynamic left ventricular systolic function, and septal mid-myocardial late gadolinium enhancement, which are characteristic of hypertrophic cardiomyopathy.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Imageamento por Ressonância Magnética , Distrofia Muscular de Duchenne/diagnóstico , Adulto , Cardiomiopatia Hipertrófica/complicações , Humanos , Masculino , Distrofia Muscular de Duchenne/complicações , Fenótipo
16.
Res Sq ; 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38260274

RESUMO

Cine Cardiac Magnetic Resonance (CMR) is the gold standard for cardiac function evaluation, incorporating ejection fraction (EF) and strain as vital indicators of abnormal deformation. Rare pathologies like Duchenne muscular dystrophies (DMD) are monitored with repeated late gadolinium-enhanced (LGE) CMR for identification of myocardial fibrosis. However, it is judicious to reduce repeated gadolinium exposure and rather employ strain analysis from cine CMR. This solution is limited so far since full strain curves are not comparable between individual cardiac cycles and current practice mainly neglects diastolic deformation patterns. Our novel Deep Learning-based approach derives strain values aligned by key frames throughout the cardiac cycle. In a reproducibility scenario (57+82 patients), our results reveal five times more significant differences (22 vs. 4) between patients with scar and without, enhancing scar detection by +30%, improving detection of patients with preserved EF by +61%, with an overall sensitivity/specificity of 82/81%.

17.
JACC Adv ; 2(2)2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37152621

RESUMO

Traditional measures of clinical status and physiology have generally been based in health care settings, episodic, short in duration, and performed at rest. Wearable biosensors provide an opportunity to obtain continuous non-invasive physiologic data from patients with congenital heart disease (CHD) in the real-world setting, over longer durations, and across varying levels of activity. However, there are significant technical limitations to the use of wearable biosensors in CHD. Here, we review current applications of wearable biosensors in CHD; how clinical and research uses of wearable biosensors must consider various CHD physiologies; the technical challenges in developing wearable biosensors for CHD; and special considerations for digital biomarkers in CHD.

18.
Ann Pediatr Cardiol ; 15(4): 351-357, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36935839

RESUMO

Introduction: Preserved congenital heart specimens are an important component of training professionals working with children and adults with congenital heart disease. They are curated in few institutions worldwide and not freely accessible. This was a proof-of-concept project to explore the use of advanced cardiac imaging modalities (computed tomography [CT] and magnetic resonance imaging [MRI]) and virtual reality (VR) simulation to assess the feasibility and identify the best method of imaging curated cardiac pathology specimens. Methods: Seven specimens in glass jars with formalin, with varied anatomic lesions, from a curated collection were imaged using MRI and high-dose CT to compare the fidelity of models created via each modality. Three-dimensional (3D) models were created and loaded into a VR headset and viewed in virtual space. Two independent physicians performed a "virtual dissection" and scored the resultant models. Results: The highest fidelity and tissue characterization of more delicate structures was achieved with T2 spoiled gradient-echo sequences on MRI (median score of 4 out of 5). CT (median score of 3), while excellent for external anatomy, lost some fidelity with delicate internal anatomy, even at high-radiation doses. No specimens were damaged. Conclusions: We believe that in vitro heart specimens can be easily scanned with high fidelity at a relatively low cost, without causing damage, using high-dose CT and MRI. The ability to "walk through" different chambers of the heart makes the understanding of anatomy easy and intuitive. VR and 3D printing are technologies that could be easily adapted to digitize preserved heart specimens, making it globally accessible for teaching and training purposes.

19.
Children (Basel) ; 9(4)2022 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-35455541

RESUMO

Transcatheter device intervention is now offered as first line therapy for many congenital heart defects (CHD) which were traditionally treated with cardiac surgery. While off-label use of devices is common and appropriate, a growing number of devices are now specifically designed and approved for use in CHD. Advanced imaging is now an integral part of interventional procedures including pre-procedure planning, intra-procedural guidance, and post-procedure monitoring. There is robust societal and industrial support for research and development of CHD-specific devices, and the regulatory framework at the national and international level is patient friendly. It is against this backdrop that we review transcatheter implantable devices for CHD, the role and integration of advanced imaging, and explore the current regulatory framework for device approval.

20.
JRSM Cardiovasc Dis ; 11: 20480040221087556, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35342625

RESUMO

A high temporal resolution, 4-chamber (4CH) cine is the standard method for determining cardiac rest periods during whole heart coronary magnetic resonance angiography (CMRA). We evaluated the image quality and reproducibility between the 4CH cine method and a novel approach using a velocity encoded mitral valve inflow cine (MVI). The goal of this study was to compare the quality of CMRAs utilizing MVI versus 4CH methods. Sharpness and vessel length for the LCA and RCA using each method were determined using Soap Bubble and two blinded observers independently assessed coronary image quality. Offline analysis on a separate, retrospective cohort (n = 25) was used to compare MVI and 4CH reproducibility. In the prospectively evaluated cohort there was no difference in overall vessel sharpness (4CH vs MVI mean ± SD) (31.0 ± 5.5% vs 30.5 ± 5.7%, p = .63), LCA vessel sharpness (30.0 ± 5.4% vs 31.1 ± 8.2%, p = .44), LCA length (4.7 ± 1.4 cm vs 4.6 ± 1.6 cm, p = .66), RCA vessel sharpness (32.1 ± 6.9% vs 31.1 ± 7.7%, p = .55), RCA length (5.51 ± 2.6 cm vs 5.95 ± 2.4 cm, p = .38), or image quality rating (2.66 vs 2.62, p = .80) between methods. In the retrospective cohort, the MVI method had 5.4% lower inter-observer variability (95% CI 3.7,7.2%, p < .0001) and 3.9% lower intra-observer variability (95% CI 2.4,5.4%, p < .0001) than the 4CH method. MVI is a technically feasible and more reproducible method to determine cardiac rest periods compared to 4CH while preserving vessel sharpness, vessel length & image quality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA