Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 22(6): 1475-91, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26524313

RESUMO

High-accuracy transmission XAFS determined using the hybrid technique has been used to refine the geometries of bis(N-n-propyl-salicylaldiminato) nickel(II) (n-pr Ni) and bis(N-i-propyl-salicylaldiminato) nickel(II) (i-pr Ni) complexes which have approximately square planar and tetrahedral metal coordination. Multiple-scattering formalisms embedded in FEFF were used for XAFS modelling of the complexes. Here it is shown that an IFEFFIT-like package using weighting from experimental uncertainty converges to a well defined XAFS model. Structural refinement of (i-pr Ni) was found to yield a distorted tetrahedral geometry providing an excellent fit, χr(2) = 2.94. The structure of (n-pr Ni) is best modelled with a distorted square planar geometry, χr(2) = 3.27. This study demonstrates the insight that can be obtained from the propagation of uncertainty in XAFS analysis and the consequent confidence which can be obtained in hypothesis testing and in analysis of alternate structures ab initio. It also demonstrates the limitations of this (or any other) data set by defining the point at which signal becomes embedded in noise or amplified uncertainty, and hence can justify the use of a particular k-range for one data set or a different range for another. It is demonstrated that, with careful attention to data collection, including the correction of systematic errors with statistical analysis of uncertainty (the hybrid method), it is possible to obtain reliable structural information from dilute solutions using transmission XAFS data.

2.
J Synchrotron Radiat ; 22(4): 1008-21, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26134805

RESUMO

A new approach is introduced for determining X-ray absorption spectroscopy (XAS) spectra on absolute and relative scales using multiple solutions with different concentrations by the characterization and correction of experimental systematics. This hybrid technique is a development of standard X-ray absorption fine structure (XAFS) along the lines of the high-accuracy X-ray extended range technique (XERT) but with applicability to solutions, dilute systems and cold cell environments. This methodology has been applied to determining absolute XAS of bis(N-n-propyl-salicylaldiminato) nickel(II) and bis(N-i-propyl-salicylaldiminato) nickel(II) complexes with square planar and tetrahedral structures in 15 mM and 1.5 mM dilute solutions. It is demonstrated that transmission XAS from dilute systems can provide excellent X-ray absorption near-edge structure (XANES) and XAFS spectra, and that transmission measurements can provide accurate measurement of subtle differences including coordination geometries. For the first time, (transmission) XAS of the isomers have been determined from low-concentration solutions on an absolute scale with a 1-5% accuracy, and with relative precision of 0.1% to 0.2% in the active XANES and XAFS regions after inclusion of systematic corrections.

3.
J Synchrotron Radiat ; 21(Pt 2): 413-23, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24562564

RESUMO

The X-ray mass attenuation coefficients of silver were measured in the energy range 5-20 keV with an accuracy of 0.01-0.2% on a relative scale down to 5.3 keV, and of 0.09-1.22% on an absolute scale to 5.0 keV. This analysis confirms that with careful choice of foil thickness and careful correction for systematics, especially including harmonic contents at lower energies, the X-ray attenuation of high-Z elements can be measured with high accuracy even at low X-ray energies (<6 keV). This is the first high-accuracy measurement of X-ray mass attenuation coefficients of silver in the low energy range, indicating the possibility of obtaining high-accuracy X-ray absorption fine structure down to the L1 edge (3.8 keV) of silver. Comparison of results reported here with an earlier data set optimized for higher energies confirms accuracy to within one standard error of each data set collected and analysed using the principles of the X-ray extended-range technique (XERT). Comparison with theory shows a slow divergence towards lower energies in this region away from absorption edges. The methodology developed can be used for the XAFS analysis of compounds and solutions to investigate structural features, bonding and coordination chemistry.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA