Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Surgery ; 110(4): 645-54; discussion 654-5, 1991 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-1833846

RESUMO

Previous studies have shown the effectiveness of partially resorbable arterial prostheses in the rabbit. This study compares these same compound prostheses with commercial graft materials in the dog. Conduits 4 mm inner diameter X 50 mm in length were woven from composite yarns containing 69% polyglactin 910 (PG910)/31% polypropylene or containing 70% polydioxanone/30% polypropylene. Nonresorbable controls were woven Dacron and expanded polytetrafluoroethylene (ePTFE). Baseline platelet aggregometry to 10(-5) mol/L adenosine diphosphate was performed. Seventy prostheses were implanted into the aorto-ilac positions, and the prosthesis/tissue complexes were harvested serially from 2 weeks to 1 year. Explanted specimens were photographed and fixed for light microscopy and for scanning and transmission electron microscopy. Results showed no aneurysms or perigraft hematomas. Overall patency for the PG910/polypropylene grafts was 18 of 20 (90%) and for polydioxanone/polypropylene was 19 of 22 (86%). For Dacron and ePTFE, 13 of 19 (68%) and 6 of 11 (54%) remained patent at time of explantation. The partially resorbable grafts, as a group, had significantly greater patency than the control grafts (p less than 0.03). Platelet aggregometry was not predictive of graft patency. Histologic analysis of the partially bioresorbable groups showed inner capsules (IC) composed of myofibroblasts and collagen beneath confluent endothelialized surfaces by 1 month. Kinetics of IC formation paralleled the rates of resorption of the resorbable components. IC cellularity and thickness were greater than those within Dacron or ePTFE. This study suggests an enhanced transinterstitial endothelial cell and myofibroblast ingrowth into the ICs of partially resorbable grafts and shows the effectiveness of these prostheses in the dog.


Assuntos
Prótese Vascular , Absorção , Animais , Vasos Sanguíneos/patologia , Vasos Sanguíneos/ultraestrutura , Cães , Polidioxanona/farmacocinética , Polietilenotereftalatos , Poliglactina 910/farmacocinética , Polipropilenos/farmacocinética , Politetrafluoretileno , Complicações Pós-Operatórias , Período Pós-Operatório , Fatores de Tempo , Grau de Desobstrução Vascular
2.
J Cardiovasc Surg (Torino) ; 31(6): 712-8, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2262494

RESUMO

Several laboratories have found canine platelet aggregometry predictive of thrombotic potential in vascular grafts. Adenosine diphosphate (ADP) is a frequently used agonist, often at unspecified or differing concentrations. This study was designed to evaluate the predictive value of ADP-induced platelet aggregometry and the validity of the methodology. Platelet aggregometry in response to 2 x 10(-5) M ADP was assayed in 70 dogs. Twenty-six percent were aggregators, 51% were non-aggregators, and 20% were indeterminant. All dogs were then treated with aspirin and dipyridamole. Vascular prostheses were implanted bilaterally (aorto-iliac) and anti-platelet therapy continued for two weeks. Dose-response to ADP was studied at three concentrations in 20 dogs. At 2 x 10(-5) 1/20 aggregated, at 4 x 10(-5) 3/19 aggregated and at 2 x 10(-4) 15/20 aggregated. Time between samples and study was evaluated in 11 dogs, with 2/11 changing from non-aggregator to aggregator at two or three hours. Daily reproducibility was studied in 70 dogs, 14 of which changed aggregation status between days. Patency was 58/68 (85%) for non-aggregators, 23/34 (68%) for aggregators (p = 0.038). Platelet aggregometry has significant predictive value for graft patency but methodology must be specified and standardized.


Assuntos
Oclusão de Enxerto Vascular/epidemiologia , Agregação Plaquetária/fisiologia , Difosfato de Adenosina/administração & dosagem , Difosfato de Adenosina/fisiologia , Difosfato de Adenosina/uso terapêutico , Animais , Aspirina/administração & dosagem , Aspirina/uso terapêutico , Prótese Vascular/classificação , Dipiridamol/administração & dosagem , Dipiridamol/uso terapêutico , Cães , Relação Dose-Resposta a Droga , Estudos de Avaliação como Assunto , Oclusão de Enxerto Vascular/sangue , Oclusão de Enxerto Vascular/tratamento farmacológico , Agregação Plaquetária/efeitos dos fármacos , Contagem de Plaquetas , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes
3.
J Cardiovasc Surg (Torino) ; 33(4): 407-14, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1388174

RESUMO

This study aimed to determine the kinetics of albumin resorption from and the healing of two types of albumin impregnated Vasculour II (Bard Cardiovascular) Dacron grafts (ACG-A and ACG-B) using whole blood preclotted Vasculour II Dacron grafts (without albumin) as controls (PCC). Prostheses measuring 4 mm ID x 50 mm length were implanted in the aortoiliac position in 24 dogs (ACG-A n = 12, ACG-B n = 24, PCC n = 12) and explanted after 1, 2 4, and 6 months. Platelet count, platelet aggregometry to 10(-5) M ADP, prothrombin time (PT), and partial thromboplastin time (PTT) were determined preoperatively and at explantation. Sections of the explanted grafts were assayed for human albumin by immunohistochemical techniques utilizing a rabbit polyclonal mono-specific antibody for human albumin followed by the addition of a biotinylated goat anti-rabbit IgG. Immunoperoxidase staining was then performed using Avidin D horse-radish peroxidase. Histology of the grafts (light microscopy, scanning electron microscopy, and transmission electron microscopy) as well as percent thrombus free surface area (TFSA) by computerized planimetry were also determined. Seven of 48 grafts were occluded (85.4% patency) with no difference among the three groups. Platelet aggregometry was not predictive of graft patency. No change in PT or PTT occurred nor was there any difference among the three groups. Retained albumin was detected in every one-month explant but not beyond that time, with the sensitivity for detecting human albumin in this assay being 20 mg albumin per gram of Dacron. All ACG explants at one month revealed inner capsular fibrin coagula not present in PCC specimens.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Albuminas/farmacocinética , Prótese Vascular , Albuminas/efeitos adversos , Animais , Aorta Abdominal/cirurgia , Cães , Estudos de Avaliação como Assunto , Artéria Ilíaca/cirurgia , Imuno-Histoquímica , Microscopia Eletrônica , Microscopia Eletrônica de Varredura , Polietilenotereftalatos , Desenho de Prótese , Fatores de Tempo , Cicatrização
4.
J Biomed Mater Res ; 26(10): 1383-94, 1992 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-1429752

RESUMO

Polypropylene's physical properties (e.g., high tensile strength) and relatively inert behavior suggest that fabrication into an arterial substitute may result in an efficacious prosthesis. Grafts were woven from polypropylene yarn into conduits 4 mm I.D. x 50 mm in length. Control grafts were Dacron and ePTFE. Baseline platelet aggregometry on all dogs was performed with 10(-5) M ADP. Aspirin and dipyridamole were given for three days preoperatively and maintained for 2 weeks after surgery. Fifty-four grafts were placed into the aortoiliac position, two different graft materials per dog. The grafts were explanted at intervals of 2 weeks through 16 months; photographed for thrombus-free surface area determinations; and preserved for light, scanning, and transmission electron microscopy. Late (4-16 month) patency was 81% (13/16) for polypropylene, 69% (9/13) for Dacron, and 20% (1/5) for ePTFE. These data include one year patencies of 11/12 (92%) for polypropylene and 7/10 (70%) for Dacron. Late patency for polypropylene grafts was better than for PTFE (p less than 0.05). Platelet aggregation status did not predict graft patency. Light microscopy of 2-week polypropylene explants showed inner capsules composed of myofibroblasts and macrophages, with patchy areas of endothelial cells lining the lumen. By 1 month, a confluent endothelialized surface was seen in all polypropylene explants. Progressive thickening of inner capsules with myofibroblasts and collagen continued through 4 months, reaching a mean thickness of 142 +/- 50 microns (compared to 150 +/- 30 microns for Dacron). These findings suggest potential clinical efficacy for polypropylene as an arterial substitute.


Assuntos
Prótese Vascular , Polipropilenos , Difosfato de Adenosina/farmacologia , Animais , Aspirina/uso terapêutico , Dipiridamol/uso terapêutico , Cães , Reação a Corpo Estranho , Microscopia Eletrônica , Microscopia Eletrônica de Varredura , Agregação Plaquetária/efeitos dos fármacos , Polietilenotereftalatos , Politetrafluoretileno , Grau de Desobstrução Vascular
5.
J Biomed Mater Res ; 27(7): 955-61, 1993 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8360222

RESUMO

Bioresorbable vascular grafts constructed for polyglactin 910 (PG910) and polydioxanone (PDS) and nonresorbable Dacron were interposed into the infrarenal abdominal aortas of New Zealand White rabbits. The prosthesis/tissue complexes were harvested after 2, 3, 4, 12, and 52 weeks. Seventeen, 9, and 1 h prior to sacrifice, animals received tritiated thymidine (0.5 mCi/kg/dose). All specimens were studied grossly and by light and transmission electron microscopy. Mitotic indices (MI's) were determined by autoradiography for inner capsule myofibroblasts at the proximal, mid, and distal segments of each prosthesis. There were no aortic-related deaths. All grafts were patent with no aneurysmal dilatation. At 4 weeks, PG910 resorption was evidenced by macrophage phagocytosis, less so in PDS while Dacron remained intact. At 12 weeks, the PG910 was completely resorbed while PDS resorption continued. The latter was completely resorbed by 52 weeks. There was no significant difference in MI's between proximal, mid, and distal regions for each graft type. The mitotic index paralleled the rate of prosthetic resorption in both PG910 and PDS groups, as high as 28.34 +/- 23.21 in the former 3 weeks after implantation and significantly higher at 4 weeks (7.58 +/- 2.02 and 7.50 +/- 2.66, respectively) than at 52 weeks (0.72 +/- 0.98 and 1.00 +/- 0.22, respectively) in both groups. The mitotic index in the Dacron group never surpassed 1.22 +/- 0.90. We conclude that higher levels of early cell proliferation in bioresorbable grafts closely parallel the kinetics of prosthetic resorption.


Assuntos
Prótese Vascular , Endotélio Vascular/patologia , Polidioxanona , Polietilenotereftalatos , Poliglactina 910 , Animais , Divisão Celular , Endotélio Vascular/ultraestrutura , Feminino , Microscopia Eletrônica , Índice Mitótico , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA