1.
N Engl J Med ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38767244

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

2.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38262674

RESUMO

AIMS: Non-invasive myocardial scar characterization with cardiac magnetic resonance (CMR) has been shown to accurately identify conduction channels and can be an important aid for ventricular tachycardia (VT) ablation. A new mapping method based on targeting deceleration zones (DZs) has become one of the most commonly used strategies for VT ablation procedures. The aim of the study was to analyse the capability of CMR to identify DZs and to find predictors of arrhythmogenicity in CMR channels. METHODS AND RESULTS: Forty-four consecutive patients with structural heart disease and VT undergoing ablation after CMR at a single centre (October 2018 to July 2021) were included (mean age, 64.8 ± 11.6 years; 95.5% male; 70.5% with ischaemic heart disease; a mean ejection fraction of 32.3 ± 7.8%). The characteristics of CMR channels were analysed, and correlations with DZs detected during isochronal late activation mapping in both baseline maps and remaps were determined. Overall, 109 automatically detected CMR channels were analysed (2.48 ± 1.15 per patient; length, 57.91 ± 63.07 mm; conducting channel mass, 2.06 ± 2.67 g; protectedness, 21.44 ± 25.39 mm). Overall, 76.1% of CMR channels were associated with a DZ. A univariate analysis showed that channels associated with DZs were longer [67.81 ± 68.45 vs. 26.31 ± 21.25 mm, odds ratio (OR) 1.03, P = 0.010], with a higher border zone (BZ) mass (2.41 ± 2.91 vs. 0.87 ± 0.86 g, OR 2.46, P = 0.011) and greater protectedness (24.97 ± 27.72 vs. 10.19 ± 9.52 mm, OR 1.08, P = 0.021). CONCLUSION: Non-invasive detection of targets for VT ablation is possible with CMR. Deceleration zones found during electroanatomical mapping accurately correlate with CMR channels, especially those with increased length, BZ mass, and protectedness.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Frequência Cardíaca/fisiologia , Arritmias Cardíacas , Cicatriz/patologia , Ablação por Cateter/métodos
3.
Medicina (Kaunas) ; 60(1)2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38256411

RESUMO

Background and Objectives: Left atrial (LA) remodelling and dilatation predicts atrial fibrillation (AF) recurrences after catheter ablation. However, whether right atrial (RA) remodelling and dilatation predicts AF recurrences after ablation has not been fully evaluated. Materials and Methods: This is an observational study of 85 consecutive patients (aged 57 ± 9 years; 70 [82%] men) who underwent cardiac magnetic resonance before first catheter ablation for AF (40 [47.1%] persistent AF). Four-chamber cine-sequence was selected to measure LA and RA area, and ventricular end-systolic image phase to obtain atrial 3D volumes. The effect of different variables on event-free survival was investigated using the Cox proportional hazards model. Results: In patients with persistent AF, combined LA and RA area indexed to body surface area (AILA + RA) predicted AF recurrences (HR = 1.08, 95% CI 1.00-1.17, p = 0.048). An AILA + RA cut-off value of 26.7 cm2/m2 had 72% sensitivity and 73% specificity for predicting recurrences in patients with persistent AF. In this group, 65% of patients with AILA + RA > 26.7 cm2/m2 experienced AF recurrence within 2 years of follow-up (median follow-up 11 months), compared to 25% of patients with AILA + RA ≤ 26.7 cm2/m2 (HR 4.28, 95% CI 1.50-12.22; p = 0.007). Indices of LA and RA dilatation did not predict AF recurrences in patients with paroxysmal AF. Atrial 3D volumes did not predict AF recurrences after ablation. Conclusions: In this pilot study, the simple measurement of AILA + RA may predict recurrences after ablation of persistent AF, and may outperform measurements of atrial volumes. In paroxysmal AF, atrial dilatation did not predict recurrences. Further studies on the role of RA and LA remodelling are needed.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Projetos Piloto , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração
4.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37751383

RESUMO

AIMS: Recurrence of arrhythmia after catheter ablation of atrial fibrillation (AF) in the form of atypical atrial flutter (AFL) is common among a significant number of patients and often requires redo ablation with limited success rates. Identifying patients at high risk of AFL after AF ablation could aid in patient selection and personalized ablation approach. The study aims to assess the relationship between pre-existing atrial cardiomyopathy and the occurrence of AFL following AF ablation. METHODS AND RESULTS: We analysed a cohort of 1007 consecutive AF patients who underwent catheter ablation and were included in a prospective registry. Patients who did not have baseline cardiac magnetic resonance imaging and late gadolinium enhancement (LGE-CMR) or did not experience any recurrences were excluded. A total of 166 patients were included gathering 56 patients who underwent re-ablation due to AFL recurrences and 110 patients who underwent re-ablation due to AF recurrences (P = 0.11). A multiparametric assessment of atrial cardiomyopathy was based on basal LGE-CMR, including left atrial (LA) volume, LA sphericity, and global and segmental LA fibrosis using semiautomated post-processing software. Out of the initial cohort of 1007 patients, AFL and AF occurred in 56 and 110 patients, respectively. An age higher than 65 [odds ratio (OR) = 5.6, 95% confidence interval (CI): 2.2-14.4], the number of previous ablations (OR = 3.0, 95% CI: 1.2-7.8), and the management of ablation lines in the index procedure (OR = 2.5, 95% CI: 1.0-6.3) were independently associated with AFL occurrence. Furthermore, several characteristics assessed by LGE-CMR were identified as independent predictors of AFL recurrence after the index ablation for AF, such as enhanced LA sphericity (OR = 1.3, 95% CI: 1.1-1.6), LA global fibrosis (OR = 1.03, 95% CI: 1.01-1.07), and increased fibrosis in the lateral wall (OR = 1.03, 95% CI: 1.01-1.04). CONCLUSION: Advanced atrial cardiomyopathy assessed by LGE-CMR, such as increased LA sphericity, global LA fibrosis, and fibrosis in the lateral wall, is independently associated with arrhythmia recurrence in the form of AFL following AF ablation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Cardiomiopatias , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Ablação por Cateter/efeitos adversos , Espectroscopia de Ressonância Magnética
5.
Europace ; 25(3): 989-999, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36607130

RESUMO

AIMS: Heterogeneous tissue channels (HTCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular arrhythmias, but there are few published data about their arrhythmogenic characteristics. METHODS AND RESULTS: We enrolled 34 consecutive patients with ischaemic and non-ischaemic cardiomyopathy who were referred for ventricular tachycardia (VT) ablation. LGE-CMR was performed prior to ablation, and the HTCs were analyzed. Arrhythmogenic HTCs linked to induced VT were identified during the VT ablation procedure. The characteristics of arrhythmogenic HTCs were compared with those of non-arrhythmogenic HTCs. Three patients were excluded due to low-quality LGE-CMR images. A total of 87 HTCs were identified on LGE-CMR in 31 patients (age:63.8 ± 12.3 years; 96.8% male; left ventricular ejection fraction: 36.1 ± 10.7%). Of the 87 HTCs, only 31 were considered arrhythmogenic because of their relation to a VT isthmus. The HTCs related to a VT isthmus were longer [64.6 ± 49.4 vs. 32.9 ± 26.6 mm; OR: 1.02; 95% CI: (1.01-1.04); P < 0.001] and had greater mass [2.5 ± 2.2 vs. 1.2 ± 1.2 grams; OR: 1.62; 95% CI: (1.18-2.21); P < 0.001], a higher degree of protectedness [26.19 ± 19.2 vs. 10.74 ± 8.4; OR 1.09; 95% CI: (1.04-1.14); P < 0.001], higher transmurality [number of wall layers with CCs: 3.8 ± 2.4 vs. 2.4 ± 2.0; OR: 1.31; 95% CI: (1.07-1.60); P = 0.008] and more ramifications [3.8 ± 2.0 vs. 2.7 ± 1.1; OR: 1.59; 95% CI: (1.15-2.19); P = 0.002] than non-arrhythmogenic HTCs. Multivariate logistic regression analysis revealed that protectedness was the strongest predictor of arrhythmogenicity. CONCLUSION: The protectedness of an HTC identified by LGE-CMR is strongly related to its arrhythmogenicity during VT ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Cicatriz/etiologia , Cicatriz/complicações , Meios de Contraste , Gadolínio , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Miocárdio/patologia , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/efeitos adversos
6.
Europace ; 25(2): 360-365, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36125227

RESUMO

AIMS: Electrical reconnection of pulmonary veins (PVs) is considered an important determinant of recurrent atrial fibrillation (AF) after pulmonary vein isolation (PVI). To date, AF recurrences almost automatically trigger invasive repeat procedures, required to assess PVI durability. With recent technical advances, it is becoming increasingly common to find all PVs isolated in those repeat procedures. Thus, as ablation of extra-PV targets has failed to show benefit in randomized trials, more and more often these highly invasive procedures are performed only to rule out PV reconnection. Here we aim to define the ability of late gadolinium enhancement (LGE)-magnetic resonance imaging (MRI) to rule out PV reconnection non-invasively. METHODS AND RESULTS: This study is based on a prospective registry in which all patients receive an LGE-MRI after AF ablation. Included were all patients that-after an initial PVI and post-ablation LGE-MRI-underwent an invasive repeat procedure, which served as a reference to determine the predictive value of non-invasive lesion assessment by LGE-MRI.: 152 patients and 304 PV pairs were analysed. LGE-MRI predicted electrical PV reconnection with high sensitivity (98.9%) but rather low specificity (55.6%). Of note, LGE lesions without discontinuation ruled out reconnection of the respective PV pair with a negative predictive value of 96.9%, and patients with complete LGE lesion sets encircling all PVs were highly unlikely to show any PV reconnection (negative predictive value: 94.4%). CONCLUSION: LGE-MRI has the potential to guide selection of appropriate candidates and planning of the ablation strategy for repeat procedures and may help to identify patients that will not benefit from a redo-procedure if no ablation of extra-PV targets is intended.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Meios de Contraste , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Gadolínio , Resultado do Tratamento , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Imageamento por Ressonância Magnética , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
7.
Europace ; 24(1): 165-172, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34455442

RESUMO

AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing cardiac pacing. METHODS AND RESULTS: Under the auspice of the Clinical Practice Guideline Quality Indicator Committee of the European Society of Cardiology (ESC), the Working Group for cardiac pacing QIs was formed. The Group comprised Task Force members of the 2021 ESC Clinical Practice Guidelines on Cardiac Pacing and Cardiac Resynchronization Therapy, members of the European Heart Rhythm Association, international cardiac device experts, and patient representatives. We followed the ESC methodology for QI development, which involved (i) the identification of the key domains of care by constructing a conceptual framework of the management of patients receiving cardiac pacing, (ii) the development of candidate QIs by conducting a systematic review of the literature, (iii) the selection of the final set of QIs using a modified-Delphi method, and (iv) the evaluation of the feasibility of the developed QIs. Four domains of care were identified: (i) structural framework, (ii) patient assessment, (iii) pacing strategy, and (iv) clinical outcomes. In total, seven main and four secondary QIs were selected across these domains and were embedded within the 2021 ESC Guidelines on Cardiac Pacing and Cardiac Resynchronization therapy. CONCLUSION: By way of a standardized process, 11 QIs for cardiac pacing were developed. These indicators may be used to quantify adherence to guideline-recommended clinical practice and have the potential to improve the care and outcomes of patients receiving cardiac pacemakers.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiologia , Marca-Passo Artificial , Adulto , Comitês Consultivos , Terapia de Ressincronização Cardíaca/efeitos adversos , Humanos , Indicadores de Qualidade em Assistência à Saúde
8.
Pacing Clin Electrophysiol ; 45(1): 72-82, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34820857

RESUMO

AIMS: Neither the long-term development of ablation lesions nor the capability of late gadolinium enhancement (LGE)-MRI to detect ablation-induced fibrosis at late stages of scar formation have been defined. We sought to assess the development of atrial ablation lesions over time using LGE-MRI and invasive electroanatomical mapping (EAM). METHODS AND RESULTS: Ablation lesions and total atrial fibrosis were assessed in serial LGE-MRI scans 3 months and >12 months post pulmonary vein (PV) isolation. High-density EAM performed in subsequent repeat ablation procedures served as a reference. Serial LGE-MRI of 22 patients were analyzed retrospectively. The PV encircling ablation lines displayed an average LGE, indicative of ablation-induced fibrosis, of 91.7% ± 7.0% of the circumference at 3 months, but only 62.8% ± 25.0% at a median of 28 months post ablation (p < 0.0001). EAM performed in 18 patients undergoing a subsequent repeat procedure revealed that the consistent decrease in LGE over time was owed to a reduced detectability of ablation-induced fibrosis by LGE-MRI at time-points > 12 months post ablation. Accordingly, the agreement with EAM regarding detection of ablation-induced fibrosis and functional gaps was good for the LGE-MRI at 3 months (κ .74; p < .0001), but only weak for the LGE-MRI at 28 months post-ablation (κ .29; p < .0001). CONCLUSION: While non-invasive lesion assessment with LGE-MRI 3 months post ablation provides accurate guidance for future redo-procedures, detectability of atrial ablation lesions appears to decrease over time. Thus, it should be considered to perform LGE-MRI 3 months post-ablation rather than at later time-points > 12 months post ablation, like for example, prior to a planned redo-ablation procedure.


Assuntos
Fibrilação Atrial/cirurgia , Cicatriz/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca , Cicatriz/etiologia , Meios de Contraste , Técnicas Eletrofisiológicas Cardíacas , Feminino , Fibrose/diagnóstico por imagem , Fibrose/etiologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Complicações Pós-Operatórias/etiologia , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Estudos Retrospectivos , Espanha
9.
Europace ; 23(9): 1437-1445, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-34142121

RESUMO

AIMS: Ventricular tachycardia (VT) substrate-based ablation has an increasing role in patients with structural heart disease-related VT. VT is linked to re-entry in relation to myocardial scarring with areas of conduction block (core scar) and areas of slow conduction [border zone (BZ)]. VT substrate can be analysed by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR). Our study aims to analyse the role of LGE-CMR in identifying predictors of VT recurrence after ablation. METHODS AND RESULTS: We analysed 110 consecutive patients who underwent VT ablation from 2013 to 2018. All patients underwent a preprocedural LGE-CMR, and in 94 patients (85.5%), the CMR was used to aid the ablation. All LGE-CMR images were semi-automatically processed using dedicated software to detect scarring and conducting channels. After a median follow-up of 2.7 ± 1.6 years, the overall VT recurrence was 41.8% with an implantable cardioverter-defibrillator shock reduction from 43.6% to 28.2% before and after ablation, respectively. The amount of BZ (26.6 ± 13.9 vs. 19.6 ± 9.7 g, P = 0.012), the total amount of scarring (37.1 ± 18.2 vs. 29 ± 16.3 g, P = 0,033), and left ventricular (LV) mass (168.3 ± 53.3 vs. 152.3 ± 46.4 g, P < 0.001) were associated with VT recurrence. LGE septal distribution [62.5% vs. 37.8%; hazard ratio (HR) 1.67 (1.02-3.93), P = 0.044], channels with transmural path [66.7% vs. 31.4%, HR 3.25 (1.70-6.23), P < 0.001], and midmural channels [54.3% vs. 27.6%, HR 2.49 (1.21-5.13), P = 0.013] were related with VT recurrence. Multivariate analysis showed that the presence of septal LGE [HR 3.67 (1.60-8.38), P = 0.002], transmural channels [HR 2.32 (1.15-4.72), P = 0.019], and LV mass [HR 1.01 (1.005-1.019), P = 0.002] were independent predictors of VT recurrence. CONCLUSION: Pre-procedural LGE-CMR is a helpful and feasible technique to identify patients with high risk of VT recurrence after ablation. LV mass, septal LGE distribution, and transmural channels were predictive factors of post-ablation VT recurrence.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Recidiva , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia
10.
Europace ; 23(3): 380-388, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33227129

RESUMO

AIMS: Myocardial fibrosis is a hallmark of atrial fibrillation (AF) and its characterization could be used to guide ablation procedures. Late gadolinium enhanced-magnetic resonance imaging (LGE-MRI) detects areas of atrial fibrosis. However, its accuracy remains controversial. We aimed to analyse the accuracy of LGE-MRI to identify left atrial (LA) arrhythmogenic substrate by analysing voltage and conduction velocity at the areas of LGE. METHODS AND RESULTS: Late gadolinium enhanced-magnetic resonance imaging was performed before ablation in 16 patients. Atrial wall intensity was normalized to blood pool and classified as healthy, interstitial fibrosis, and dense scar tissue depending of the resulting image intensity ratio. Bipolar voltage and local conduction velocity were measured in LA with high-density electroanatomic maps recorded in sinus rhythm and subsequently projected into the LGE-MRI. A semi-automatic, point-by-point correlation was made between LGE-MRI and electroanatomical mapping. Mean bipolar voltage and local velocity progressively decreased from healthy to interstitial fibrosis to scar. There was a significant negative correlation between LGE with voltage (r = -0.39, P < 0.001) and conduction velocity (r = -0.25, P < 0.001). In patients showing dilated atria (LA diameter ≥45 mm) the conduction velocity predictive capacity of LGE-MRI was weaker (r = -0.40 ± 0.09 vs. -0.20 ± 0.13, P = 0.02). CONCLUSIONS: Areas with higher LGE show lower voltage and slower conduction in sinus rhythm. The enhancement intensity correlates with bipolar voltage and conduction velocity in a point-by-point analysis. The performance of LGE-MRI in assessing local velocity might be reduced in patients with dilated atria (LA diameter ≥45).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Meios de Contraste , Fibrose , Gadolínio , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
11.
Europace ; 23(3): 456-463, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33595062

RESUMO

AIMS: During the COVID-19 pandemic, concern regarding its effect on the management of non-communicable diseases has been raised. However, there are no data on the impact on cardiac implantable electronic devices (CIED) implantation rates. We aimed to determine the impact of SARS-CoV2 on the monthly incidence rates and type of pacemaker (PM) and implantable cardiac defibrillator (ICD) implantations in Catalonia before and after the declaration of the state of alarm in Spain on 14 March 2020. METHODS AND RESULTS: Data on new CIED implantations for 2017-20 were prospectively collected by nine hospitals in Catalonia. A mixed model with random intercepts corrected for time was used to estimate the change in monthly CIED implantations. Compared to the pre-COVID-19 period, an absolute decrease of 56.5% was observed (54.7% in PM and 63.7% in ICD) in CIED implantation rates. Total CIED implantations for 2017-19 and January and February 2020 was 250/month (>195 PM and >55 ICD), decreasing to 207 (161 PM and 46 ICD) in March and 131 (108 PM and 23 ICD) in April 2020. In April 2020, there was a significant fall of 185.25 CIED implantations compared to 2018 [95% confidence interval (CI) 129.6-240.9; P < 0.001] and of 188 CIED compared to 2019 (95% CI 132.3-243.7; P < 0.001). No significant differences in the type of PM or ICD were observed, nor in the indication for primary or secondary prevention. CONCLUSIONS: During the first wave of the COVID-19 pandemic, a substantial decrease in CIED implantations was observed in Catalonia. Our findings call for measures to avoid long-term social impact.


Assuntos
COVID-19 , Desfibriladores Implantáveis/tendências , Marca-Passo Artificial/tendências , Padrões de Prática Médica/tendências , Implantação de Prótese/tendências , Humanos , Segurança do Paciente , Estudos Prospectivos , Implantação de Prótese/instrumentação , Espanha , Fatores de Tempo
12.
Pacing Clin Electrophysiol ; 44(3): 519-527, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33538337

RESUMO

BACKGROUND: Multipoint pacing (MPP) in cardiac resynchronization therapy (CRT) activates the left ventricle from two locations, thereby shortening the QRS duration and enabling better resynchronization; however, compared with conventional CRT, MPP reduces battery longevity. On the other hand, electrocardiogram-based optimization using the fusion-optimized intervals (FOI) method achieves more significant reverse remodeling than nominal CRT programming. Our study aimed to determine whether MPP could attain better resynchronization than single-point pacing (SPP) optimized by FOI. METHODS: This prospective study included 32 consecutive patients who successfully received CRT devices with MPP capabilities. After implantation, the QRS duration was measured during intrinsic rhythm and with three pacing configurations: MPP, SPP-FOI, and MPP-FOI. In 14 patients, biventricular activation times (by electrocardiographic imaging, ECGI) were obtained during intrinsic rhythm and for each pacing configuration to validate the findings. Device battery longevity was estimated at the 45-day follow-up. RESULTS: The SPP-FOI method achieved greater QRS shortening than MPP (-56 ± 16 vs. -42 ± 17 ms, p < .001). Adding MPP to the best FOI programming did not result in further shortening (MPP-FOI: -58 ± 14 ms, p = .69). Although biventricular activation times did not differ significantly among the three pacing configurations, only the two FOI configurations achieved significant shortening compared with intrinsic rhythm. The estimated battery longevity was longer with SPP than with MPP (8.1 ± 2.3 vs. 6.3 ± 2.0 years, p = .03). CONCLUSIONS: SPP optimized by FOI resulted in better resynchronization and longer battery duration than MPP.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Disfunção Ventricular Esquerda/terapia , Idoso , Ecocardiografia , Fontes de Energia Elétrica , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Disfunção Ventricular Esquerda/fisiopatologia
13.
J Cardiovasc Electrophysiol ; 31(3): 638-646, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31957087

RESUMO

INTRODUCTION: Ablation with second-generation cryoballoon technology evolves as an effective and safe alternative to radiofrequency for atrial fibrillation ablation procedures. Nevertheless, the optimal freezing strategy remains unknown. Our objective was to identify the procedural cryoablation parameters predicting successful peri-pulmonary vein (PV) lesions by directly analyzing Postablation gaps in late-gadolinium-enhanced cardiac magnetic resonance (LGE-CMR). METHODS AND RESULTS: Forty-nine consecutive patients (196 PVs) undergoing ablation with second-generation cryoballoon at our center were included. The number and duration of cryoballoon application to achieve PV isolation were left to operator discretion. Gap number and length were quantified in all patients with a LGE-CMR performed 3 months postablation. Application time (420 ± 217 seconds), number of applications (2.1 ± 1.2), application time after electrical isolation (311 ± 194 seconds) and minimum temperature (-45.8 ± 6.5°C) were similar in the 4 PVs. Gaps were observed in 148 PVs (76%), averaging 1.3 ± 1 gaps per vein. Gaps were longer and more frequent in the right PVs (91% vs 59% in left PVs, P < .001). Neither the number, total duration of applications, nor postisolation application time predicted relative length or number of gaps. CONCLUSIONS: After successful PV isolation was achieved in patients undergoing cryoablation, increasing the number of applications, the total application time or application time postisolation did not result in a reduction in the number or the relative length of gaps.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia , Imageamento por Ressonância Magnética , Veias Pulmonares/cirurgia , Potenciais de Ação , Adulto , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Meios de Contraste/administração & dosagem , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
14.
Europace ; 22(12): 1805-1811, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-33063124

RESUMO

AIMS: Our aim was to analyse whether using delayed enhancement cardiac magnetic resonance imaging (DE-CMR) to localize veno-atrial gaps in atrial fibrillation (AF) redo ablation procedures improves outcomes during follow-up. METHODS AND RESULTS: We conducted a case-control study with 35 consecutive patients undergoing a DE-CMR-guided Repeat-pulmonary vein isolation (Re-PVI) procedure. Those with more extensive ablations (e.g. roof lines, box) were excluded. Patients were matched for age, sex, AF pattern, and left atrial dimension with 35 patients who had undergone a conventional Re-PVI procedure guided with a three dimensional (3D)-navigation system. Procedural characteristics were recorded, and patients were followed for 24 months in a specialized outpatient clinic. The primary endpoint was freedom from recurrent AF, atrial tachycardia, or flutter. The duration of CMR-guided procedures was shorter compared to the conventional group (161 ± 52 vs. 195 ± 72 min, respectively, P = 0.049), with no significant differences in fluoroscopy or total radiofrequency time. At the 2-year follow-up, more patients in the DE-CMR-guided group remained free from recurrences compared with the conventional group (70% vs. 39%, respectively, P = 0.007). In univariate Cox-regression analyses, AF pattern [persistent AF, hazard ratio (HR) 2.66 (1.27-5.46), P = 0.006] and the use of DE-CMR [HR 0.36 (0.17-0.79), P = 0.009] predicted recurrences during follow-up; both factors remained independent predictors in multivariate analyses. CONCLUSION: The substrate characterization provided by DE-CMR facilitates the identification of anatomical veno-atrial gaps and associates with shorter procedures and better clinical outcomes in repeated AF ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Humanos , Espectroscopia de Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
15.
Europace ; 22(3): 382-387, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31821484

RESUMO

AIMS: Cryoballoon (CB) ablation has emerged as a reliable modality to isolate pulmonary veins (PVs) in atrial fibrillation. Ablation lesions and the long-term effects of energy delivery can be assessed by delayed-enhancement cardiac magnetic resonance (DE-CMR). The aim of the study was to compare the number, extension, and localization of gaps in CB and radiofrequency (RF) techniques in pulmonary vein isolation (PVI). METHODS AND RESULTS: Consecutive patients submitted to PVI with CB in whom DE-CMR images were available (n = 30) were matched (1:1) to patients who underwent PVI with RF (n = 30), considering age, sex, hypertension, and diabetes. Delayed-enhancement cardiac magnetic resonance was obtained at 3 months post-procedure, and images were processed to assess the mean number of gaps around PV ostia, their localization, and the normalized gap length (NGL), calculated as the difference between total gap length and total PV perimeter. Patients were followed up for 12 months. The CB and RF procedures did not differ in the mean number of gaps per patient (4.40 vs. 5.13 gaps, respectively; P = 0.21) nor NGL (0.35 vs. 0.32, P = 0.59). For both techniques, a higher mean number of gaps were detected in right vs. left PVs (3.18 vs. 1.58, respectively; P = 0.01). The incidence of recurrences did not differ between techniques (odds ratio 1.87, 95% confidence interval 0.66-4.97; P = 0.29). CONCLUSION: Location and extension of ablation gaps in PVI did not differ between CB and RF groups in DE-CMR image analysis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Espectroscopia de Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
16.
Europace ; 21(9): 1286-1296, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31038177

RESUMO

Cardiac resynchronization therapy (CRT) is a cornerstone of therapy for patients with heart failure, reduced left ventricular (LV) ejection fraction, and a wide QRS complex. However, not all patients respond to CRT: 30% of CRT implanted patients are currently considered clinical non-responders and up to 40% do not achieve LV reverse remodelling. In order to achieve the best CRT response, appropriate patient selection, device implantation, and programming are important factors. Optimization of CRT pacing intervals may improve results, increasing the number of responders, and the magnitude of the response. Echocardiography is considered the reference method for atrioventricular and interventricular (VV) intervals optimization but it is time-consuming, complex and it has a large interobserver and intraobserver variability. Previous studies have linked QRS shortening to clinical response, echocardiographic improvement and favourable prognosis. In this review, we describe the electrocardiographic optimization methods available: 12-lead electrocardiogram; fusion-optimized intervals (FOI); intracardiac electrogram-based algorithms; and electrocardiographic imaging. Fusion-optimized intervals is an electrocardiographic method of optimizing CRT based on QRS duration that combines fusion with intrinsic conduction. The FOI method is feasible and fast, further reduces QRS duration, can be performed during implant, improves acute haemodynamic response, and achieves greater LV remodelling compared with nominal programming of CRT.


Assuntos
Algoritmos , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Insuficiência Cardíaca/terapia , Remodelação Ventricular , Ecocardiografia , Técnicas Eletrofisiológicas Cardíacas , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Volume Sistólico , Falha de Tratamento , Resultado do Tratamento
17.
Curr Cardiol Rep ; 21(10): 127, 2019 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-31520271

RESUMO

PURPOSE OF REVIEW: The goal of this paper is to review present knowledge regarding preventive and antitachycardia pacing algorithms, aimed to reduce atrial fibrillation (AF) burden in patients when pacing is indicated. RECENT FINDINGS: Reactive antitachycardia pacing (ATP), the new generation of ATP, is significantly associated with a reduced risk of AF. In patients with indication for pacing and history of AF, pacemakers endowed with atrial preventive pacing and atrial ATP combined with managed ventricular pacing proved superior to standard dual-chamber pacing. Managed ventricular pacing is an algorithm that minimizes unnecessary right ventricular pacing. Progression to persistent AF is prevented by ventricular pacing minimization in patients with normal PR interval. The synergistic effect of pacemakers that combine atrial preventive pacing with reactive ATP and with algorithms that minimize ventricular pacing can reduce AF incidence and decrease the combined endpoint of permanent AF, hospital admissions, and mortality.


Assuntos
Fibrilação Atrial/terapia , Bradicardia/terapia , Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial , Terapia Assistida por Computador/métodos , Algoritmos , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Bradicardia/complicações , Bradicardia/mortalidade , Estimulação Cardíaca Artificial/efeitos adversos , Átrios do Coração , Humanos , Resultado do Tratamento
18.
Indian Pacing Electrophysiol J ; 19(4): 140-144, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30794927

RESUMO

AIMS: Riata® implantable cardioverter-defibrillator (ICD) leads from St. Jude Medical are prone to malfunction. This study aimed to describe the rate of this lead's malfunction in a very long-term follow-up. METHODS: This single-centre observational study included 50 patients who received a Riata 7Fr dual-coil lead between 2003 and 2008. Follow-up was conducted both in person and remotely, and analysed at 8-month intervals. We evaluated the rates of cable externalization (CE), electrical failure (EF), and the interaction of these two complications. Structural lead failure was defined as radiographic CE. Oversensing of non-cardiac signal or sudden changes in impedance, sensing, or pacing thresholds constituted EF. RESULTS: During a mean follow-up of 10.2 ±â€¯2.9 years, 16 patients (32%) died. We observed lead malfunction in 13 patients (26%): three (23%) due to CE, six (46%) to EF and four (31%) to both complications. Of the malfunctioning leads, 77% failed after seven years of follow-up. The incidence rate (IR) of overall malfunction per 100 patients per year was 0.9 during the first seven years post-implantation, increased to 7.0 after the 7th year and more than doubled (to 16.7) after 10 years. Beyond seven years post-implantation, IR per 100 patient-years increased in both EF and CE (from 0.6 to 5.6 vs. 0.3 to 4.2, respectively). Presence of CE was associated with a 4-fold increase in the proportion of EF. CONCLUSION: The incidence of Riata ICD lead malfunction, both for EF and CE, increased dramatically after seven years and then more than doubled after 10 years post-implantation.

19.
Europace ; 20(12): 1959-1965, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29860416

RESUMO

Aims: Left atrial (LA) fibrosis can be identified by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) in patients with atrial fibrillation (AF). However, there is limited information about anatomical fibrosis distribution in the left atrium. The aim is to determine whether there is a preferential spatial distribution of fibrosis in the left atrium in patients with AF. Methods and results: A 3-Tesla LGE-CMR was performed in 113 consecutive patients referred for AF ablation. Images were post-processed and analysed using ADAS-AF software (Galgo Medical), which allows fibrosis identification in 3D colour-coded shells. A regional semiautomatic LA parcellation software was used to divide the atrial wall into 12 segments: 1-4, posterior wall; 5-6, floor; 7, septal wall; 8-11, anterior wall; 12, lateral wall. The presence and amount of fibrosis in each segment was obtained for analysis. After exclusions for artefacts and insufficient image quality, 76 LGE-MRI images (68%) were suitable for fibrosis analysis. Segments 3 and 5, closest to the left inferior pulmonary vein, had significantly higher fibrosis (40.42% ± 23.96 and 25.82% ± 21.24, respectively; P < 0.001), compared with other segments. Segments 8 and 10 in the anterior wall contained the lowest fibrosis (2.54% ± 5.78 and 3.82% ± 11.59, respectively; P < 0.001). Age >60 years was significantly associated with increased LA fibrosis [95% confidence interval (CI) 0.19-8.39, P = 0.04] and persistent AF approached significance (95% CI -0.19% to 7.83%, P = 0.08). Conclusion: In patients with AF, the fibrotic area is preferentially located at the posterior wall and floor around the antrum of the left inferior pulmonary vein. Age >60 years was associated with increased fibrosis.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Função do Átrio Esquerdo , Remodelamento Atrial , Meios de Contraste/administração & dosagem , Átrios do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Compostos Organometálicos/administração & dosagem , Veias Pulmonares/diagnóstico por imagem , Fatores Etários , Idoso , Fibrilação Atrial/patologia , Fibrilação Atrial/fisiopatologia , Feminino , Fibrose , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/patologia , Veias Pulmonares/fisiopatologia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS