Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Nature ; 565(7739): 328-330, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30617314

RESUMO

The probability that a nucleus will absorb a neutron-the neutron capture cross-section-is important to many areas of nuclear science, including stellar nucleosynthesis, reactor performance, nuclear medicine and defence applications. Although neutron capture cross-sections have been measured for most stable nuclei, fewer results exist for radioactive isotopes, and statistical-model predictions typically have large uncertainties1. There are almost no nuclear data for neutron-induced reactions of the radioactive nucleus 88Zr, despite its importance as a diagnostic for nuclear security. Here, by exposing 88Zr to the intense neutron flux of a nuclear reactor, we determine that 88Zr has a thermal neutron capture cross-section of 861,000 ± 69,000 barns (1σ uncertainty), which is five orders of magnitude larger than the theoretically predicted value of 10 barns2. This is the second-largest thermal neutron capture cross-section ever measured and no other cross-section of comparable size has been discovered in the past 70 years. The only other nuclei known to have values greater than 105 barns3-6 are 135Xe (2.6 × 106 barns), a fission product that was first discovered as a poison in early reactors7,8, and 157Gd (2.5 × 105 barns), which is used as a detector material9,10, a burnable reactor poison11 and a potential medical neutron capture therapy agent12. In the case of 88Zr neutron capture, both the target and the product (89Zr) nuclei are radioactive and emit intense γ-rays upon decay, allowing sensitive detection of miniscule quantities of these radionuclides. This result suggests that as additional measurements with radioactive isotopes become feasible with the operation of new nuclear-science facilities, further surprises may be uncovered, with far-reaching implications for our understanding of neutron capture reactions.

2.
Phys Med Biol ; 55(17): 4977-92, 2010 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-20693612

RESUMO

The objective of this paper is threefold: (1) to establish sensitivity of XRQA and EBT radiochromic films to fast neutron exposure; (2) to develop a film response to radiation dose calibration curve and (3) to investigate a two-dimensional (2D) film dosimetry technique for use in establishing an experimental setup for a radiobiological irradiation of mice and to assess the dose to the mice in this setup. The films were exposed to a 10 MeV neutron beam via the (2)H(d,n)(3)He reaction. The XRQA film response was a factor of 1.39 greater than EBT film response to the 10 MeV neutron beam when exposed to a neutron dose of 165 cGy. A film response-to-soft tissue dose calibration function was established over a range of 0-10 Gy and had a goodness of fit of 0.9926 with the calibration data. The 2D film dosimetry technique estimated the neutron dose to the mice by measuring the dose using a mouse phantom and by placing a piece of film on the exterior of the experimental mouse setup. The film results were benchmarked using Monte Carlo and aluminum (Al) foil activation measurements. The radiochromic film, Monte Carlo and Al foil dose measurements were strongly correlated, and the film within the mouse phantom agreed to better than 7% of the externally mounted films. These results demonstrated the potential application of radiochromic films for passive 2D neutron dosimetry.


Assuntos
Nêutrons Rápidos/uso terapêutico , Estudos de Viabilidade , Dosimetria Fotográfica/instrumentação , Algoritmos , Alumínio/química , Animais , Calibragem , Dosimetria Fotográfica/métodos , Hélio/química , Hidrogênio/química , Camundongos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA