1.
J Sleep Res ; 29(1): e12889, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31257666

RESUMO

The high prevalence of obstructive sleep apnea has led to increasing interest in ambulatory diagnosis. The SleepMinder™ (SM) is a novel non-contact device that employs radiofrequency wave technology to assess the breathing pattern, and thereby estimate obstructive sleep apnea severity. We assessed the performance of SleepMinder™ in the home diagnosis of obstructive sleep apnea. One-hundred and twenty-two subjects were prospectively recruited in two protocols, one from an unselected sleep clinic cohort (n = 67, mean age 51 years) and a second from a hypertension clinic cohort (n = 55, mean age 58 years). All underwent 7 consecutive nights of home monitoring (SMHOME ) with the SleepMinder™ as well as inpatient-attended polysomnography in the sleep clinic cohort or cardiorespiratory polygraphy in the hypertension clinic cohort with simultaneous SleepMinder™ recordings (SMLAB ). In the sleep clinic cohort, median SMHOME apnea-hypopnea index correlated significantly with polysomnography apnea-hypopnea index (r = .68; p < .001), and in the hypertension clinic cohort with polygraphy apnea-hypopnea index (r = .7; p < .001). The median SMHOME performance against polysomnography in the sleep clinic cohort showed a sensitivity and specificity of 72% and 94% for apnea-hypopnea index ≥ 15. Device performance was inferior in females. In the hypertension clinic cohort, SMHOME showed a 50% sensitivity and 72% specificity for apnea-hypopnea index ≥ 15. SleepMinder™ classified 92% of cases correctly or within one severity class of the polygraphy classification. Night-to-night variability in home testing was relatively high, especially at lower apnea-hypopnea index levels. We conclude that the SleepMinder™ device provides a useful ambulatory screening tool, especially in a population suspected of obstructive sleep apnea, and is most accurate in moderate-severe obstructive sleep apnea.


Assuntos
Monitorização Fisiológica/instrumentação , Polissonografia/métodos , Síndromes da Apneia do Sono/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia/instrumentação , Estudos Prospectivos
2.
J Food Sci Technol ; 55(12): 4859-4866, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30482981

RESUMO

This research was performed to evaluate the impact of a novel ion-exchange treatment on the organoleptic, pH, color (hue and intensity), and oxidation-reduction potential (ORP) properties of commercial red wines. The ion-exchange treatment used in this study is a commercially available device containing a double cation-anion exchange resin. The device is applied, directly by the consumer, to finished bottled wines with the purpose of mitigating the effects of potentially noxious compounds such as biogenic amines and sulfites. Sensory evaluation tests included discriminative, affective, and Quantitative Descriptive Analysis sensory tests were employed to evaluate the impact on the perceived taste of treated wines. The pH, ORP and color parameters (hue and intensity) of wines were measured to assess any physicochemical alterations that may help to explain the results of the sensory evaluation. While no significant changes in color hue or intensity were found, the results showed a reduction in pH (0.07-0.12) and an increase in ORP (2.667-6.666 mV). However, the changes in pH and ORP did not result in a detectable change in wine taste for the sensory panelists. These findings have important implications for the wine industry, where many consumers select wines for their characteristic taste qualities. Thus, any treatment to potentially remove noxious compounds should not impact the characteristic organoleptic properties of a chosen wine.

3.
Ann Am Thorac Soc ; 21(3): 464-473, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38096106

RESUMO

Rationale: Obstructive sleep apnea (OSA) is an independent risk factor for cardiovascular (CV) morbidity and mortality, but the benefit of continuous positive airway pressure (CPAP) is uncertain. However, most randomized controlled trials have focused on the role of CPAP in secondary prevention, although there is growing evidence of a potential benefit on early CV disease. Weight loss in combination with CPAP may be superior but is difficult to achieve and maintain with conventional measures alone. Objectives: The aim of this study was to gain insights into the effect of CPAP on early atherosclerotic processes and to compare it with a glucagon-like peptide (GLP)-1-mediated weight loss regimen in patients with OSA. Methods: We performed a randomized proof-of-concept study comparing CPAP, a GLP1-mediated weight-loss regimen (liraglutide [Lir]), and both in combination for 24 weeks in 30 consecutive patients with OSA (apnea-hypopnea index >15 events/h; body mass index 30-40 kg/m2; and no history of diabetes, heart failure, or unstable CV disease). In addition to extensive evaluation for CV risk factors and endothelial function at baseline and end of study, subjects underwent 18F-fluoro-2-deoxy-D-glucose positron emission tomography-computed tomography (18F-FDG PET-CT) for the measurement of aortic wall inflammation (target-to-background ratio) and coronary computed tomography angiography for semiautomated coronary plaque analysis. Results: Baseline characteristics were similar between groups. CPAP alone and in combination resulted in greater reduction in apnea-hypopnea index than Lir alone (mean difference, -45 and -43 events/h, respectively, vs. -12 events/h; P < 0.05). Both Lir and combination treatment led to significant weight loss, but only CPAP alone resulted in significant decrease in vascular inflammation (aortic wall target-to-background ratio from 2.03 ± 0.34 to 1.84 ± 0.43; P = 0.010), associated with an improvement in endothelial function and a decrease in C-reactive protein. Low-attenuation coronary artery plaque volume as a marker of unstable plaque also decreased with CPAP (from 571 ± 490 to 334 ± 185 mm3) and with combination therapy (from 401 ± 145 to 278 ± 126 mm3) but not with Lir. Conclusions: These data suggest that CPAP therapy, but not GLP1-mediated weight loss, improves vascular inflammation and reduces unstable plaque volume in patients with OSA. Further large randomized controlled studies are warranted to assess the benefit of CPAP therapy in modifying early CV disease. Clinical trial registered with www.clinicaltrials.gov (NCT04186494).


Assuntos
Doenças Cardiovasculares , Apneia Obstrutiva do Sono , Humanos , Doenças Cardiovasculares/prevenção & controle , Pressão Positiva Contínua nas Vias Aéreas/métodos , Inflamação/complicações , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/terapia
4.
J Food Sci ; 88(11): 4677-4692, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37751062

RESUMO

Stevia is an emerging natural high-intensity sweetener. There are negative perceptions of zero-calorie sweeteners, but studies that provide knowledge of these sweeteners improve their perception. This study evaluated consumer acceptability of a zero-sugar bakery product under blind and informed conditions (n = 96) along with physicochemical analysis of the products. Rebaudioside A (Reb A) and the new types of stevia (Rebs D and M) with sugar as a control were used to formulate pound cakes. Panelists evaluated the overall hedonic impressions (aroma, texture, flavor, and aftertaste) and intensity (sweetness and bitterness) of the cakes under blind and informed conditions with an enforced 2-week break between evaluations. During the informed session, a document was provided prior to evaluating samples that included stevia's health benefits and the nutritional facts panels for the cakes. The cakes underwent volatile profile (electronic nose [e-nose]) and water activity (aw ) analysis. Overall, stevia cakes showed an increase in flavor and texture liking during the informed session when compared to the blind session, but only Reb A showed a significant difference (p < 0.05). The increase in liking scores indicated that information positively affected the consumer's perception of the stevia-sweetened cakes attributes. The e-nose confirmed differences in aroma. There was a significant difference in aw of the samples Rebs A, D, M versus sucrose (p < 0.05). No significant differences were observed among the Rebs (p > 0.05). This study illustrates that stevia, despite non-browning or fermenting, can be used in a practical baking application, and product-related information impacts consumer acceptability. PRACTICAL APPLICATION: This study demonstrates that product-related information may have an impact on the consumer acceptability of the product. Through potential labeling improvements, overall consumer perception and acceptability of zero-sugar added or low-sugar products could be improved. This study also illustrates that stevia, despite being a non-browning or fermenting sugar alternative, can be used in a practical baking application.


Assuntos
Stevia , Açúcares , Edulcorantes/análise , Aditivos Alimentares/análise , Sacarose/análise , Paladar , Comportamento do Consumidor
SELEÇÃO DE REFERÊNCIAS