Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 213
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Lancet ; 403(10445): 2695-2708, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38795719

RESUMO

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Blood ; 141(12): 1457-1468, 2023 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-36564031

RESUMO

von Willebrand factor (VWF) is a multimeric protein, the size of which is regulated via ADAMTS13-mediated proteolysis within the A2 domain. We aimed to isolate nanobodies distinguishing between proteolyzed and non-proteolyzed VWF, leading to the identification of a nanobody (designated KB-VWF-D3.1) targeting the A3 domain, the epitope of which overlaps the collagen-binding site. Although KB-VWF-D3.1 binds with similar efficiency to dimeric and multimeric derivatives of VWF, binding to VWF was lost upon proteolysis by ADAMTS13, suggesting that proteolysis in the A2 domain modulates exposure of its epitope in the A3 domain. We therefore used KB-VWF-D3.1 to monitor VWF degradation in plasma samples. Spiking experiments showed that a loss of 10% intact VWF could be detected using this nanobody. By comparing plasma from volunteers to that from congenital von Willebrand disease (VWD) patients, intact-VWF levels were significantly reduced for all VWD types, and most severely in VWD type 2A-group 2, in which mutations promote ADAMTS13-mediated proteolysis. Unexpectedly, we also observed increased proteolysis in some patients with VWD type 1 and VWD type 2M. A significant correlation (r = 0.51, P < .0001) between the relative amount of high-molecular weight multimers and levels of intact VWF was observed. Reduced levels of intact VWF were further found in plasmas from patients with severe aortic stenosis and patients receiving mechanical circulatory support. KB-VWF-D3.1 is thus a nanobody that detects changes in the exposure of its epitope within the collagen-binding site of the A3 domain. In view of its unique characteristics, it has the potential to be used as a diagnostic tool to investigate whether a loss of larger multimers is due to ADAMTS13-mediated proteolysis.


Assuntos
Doença de von Willebrand Tipo 2 , Doenças de von Willebrand , Humanos , Fator de von Willebrand/metabolismo , Doenças de von Willebrand/genética , Proteólise , Doença de von Willebrand Tipo 2/diagnóstico , Colágeno , Epitopos/metabolismo , Proteína ADAMTS13/metabolismo
3.
Circ Res ; 133(10): 826-841, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37883587

RESUMO

BACKGROUND: Thrombocytopenia has been consistently described in patients with extracorporeal membrane oxygenation (ECMO) and associated with poor outcome. However, the prevalence and underlying mechanisms remain largely unknown, and a device-related role of ECMO in thrombocytopenia has been hypothesized. This study aims to investigate the mechanisms underlying thrombocytopenia in ECMO patients. METHODS: In a prospective cohort of 107 ECMO patients, we investigated platelet count, functions, and glycoprotein shedding. In an ex vivo mock circulatory ECMO loop, we assessed platelet responses and VWF (von Willebrand factor)-GP Ibα (glycoprotein Ibα) interactions at low- and high-flow rates, in the presence or absence of red blood cells. The clearance of human platelets subjected or not to ex vivo perfusion was studied using an in vivo transfusion model in NOD/SCID (nonobese diabetic/severe combined Immunodeficient) mice. RESULTS: In ECMO patients, we observed a time-dependent decrease in platelet count starting 1 hour after device onset, with a mean drop of 7%, 35%, and 41% at 1, 24, and 48 hours post-ECMO initiation (P=0.00013, P<0.0001, and P<0.0001, respectively), regardless of the type of ECMO. This drop in platelet count was associated with a decrease in platelet GP Ibα expression (before: 47.8±9.1 versus 24 hours post-ECMO: 42.3±8.9 mean fluorescence intensity; P=0.002) and an increase in soluble GP Ibα plasma levels (before: 5.6±3.3 versus 24 hours post-ECMO: 10.8±4.1 µg/mL; P<0.0001). GP Ibα shedding was also observed ex vivo and was unaffected by (1) red blood cells, (2) the coagulation potential, (3) an antibody blocking VWF-GP Ibα interaction, (4) an antibody limiting VWF degradation, and (5) supraphysiological VWF plasma concentrations. In contrast, GP Ibα shedding was dependent on rheological conditions, with a 2.8-fold increase at high- versus low-flow rates. Platelets perfused at high-flow rates before being transfused to immunodeficient mice were eliminated faster in vivo with an accelerated clearance of GP Ibα-negative versus GP Ibα-positive platelets. CONCLUSIONS: ECMO-associated shear forces induce GP Ibα shedding and thrombocytopenia due to faster clearance of GP Ibα-negative platelets. Inhibiting GP Ibα shedding could represent an approach to reduce thrombocytopenia during ECMO.


Assuntos
Trombocitopenia , Fator de von Willebrand , Humanos , Animais , Camundongos , Fator de von Willebrand/metabolismo , Estudos Prospectivos , Camundongos Endogâmicos NOD , Camundongos SCID , Plaquetas/metabolismo , Trombocitopenia/terapia , Trombocitopenia/metabolismo
4.
Am Heart J ; 270: 86-94, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38309610

RESUMO

BACKGROUND: Patients with severe aortic stenosis (AS) frequently present with concomitant obstructive coronary artery disease (CAD). In those, current guidelines recommend combined coronary artery bypass grafting (CABG) and surgical aortic valve replacement (SAVR) as the preferred treatment option, although this surgical approach is associated with a high rate of clinical events. Combined transcatheter aortic valve implantation (TAVI) and percutaneous coronary intervention (PCI) with or without FFR have evolved as a valid alternative for cardiac surgery in patients with AS and multivessel or advanced CAD. To date, no dedicated trial has prospectively evaluated the outcomes of a percutaneous versus surgical treatment for patients with both severe AS and CAD. AIMS: To investigate whether fractional-flow reserve (FFR)-guided PCI and TAVI is noninferior to combined CABG and SAVR for the treatment of severe AS and multivessel or advanced CAD. METHODS: The Transcatheter Valve and Vessels (TCW) trial (clinicaltrial.gov: NCT03424941) is a prospective, randomized, controlled, open label, international trial. Patients ≥ 70 years with severe AS and multivessel (≥ 2 vessels) or advanced CAD, deemed feasible by the heart team for both; a full percutaneous or surgical treatment, will be randomised in a 1:1 fashion to either FFR-guided PCI followed by TAVI (intervention arm) vs. CABG and SAVR (control arm). The primary endpoint is a patient-oriented composite of all-cause mortality, myocardial infarction, disabling stroke, unscheduled clinically-driven target vessel revascularization, valve reintervention, and life threatening or disabling bleeding at 1 year. The TCW trial is powered for noninferiority, and if met, superiority will be tested. Assuming a primary endpoint rate of 30% in the CABG-SAVR arm, with a significance level α of 5%, a noninferiority limit delta of 15% and a loss to follow-up of 2%, a total of 328 patients are needed to obtain a power of 90%. The primary endpoint analysis is performed on an intention-to-treat basis. SUMMARY: The TCW Trial is the first prospective randomized trial that will study if a less invasive percutaneous treatment for severe AS and concomitant advanced CAD (i.e., FFR-guided PCI-TAVI) is noninferior to the guidelines recommended approach (CABG-SAVR).


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Valva Aórtica/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Ponte de Artéria Coronária , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
5.
Eur J Clin Invest ; : e14241, 2024 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-38767226

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being used in younger patients and those with lower peri-procedural risk, meaning more patients will live long enough to experience structural valve deterioration (SVD) of the bioprosthesis, indicating repeated TAVI. Experience of repeated TAVI-transcatheter heart valve (THV) implantation into an index THV is limited. This registry aims to assess the peri-procedural and short-term safety, efficacy and durability of repeated TAVI. METHODS: The ReTAVI Prospective observational registry is an investigator-initiated, multicentre, international, prospective registry of patients undergoing repeated TAVI using balloon-expandable SAPIEN prosthesis to evaluate procedural and short-term safety, efficacy and durability as well as anatomical and procedural factors associated with optimal results. The registry will enrol at least 150 patients across 60 high-volume centres. Patients must be ≥18 years old, have had procedural success with their first TAVI, have index THV device failure, intend to undergo repeated TAVI and be considered suitable candidates by their local Heart Team. All patients will undergo a 30-day and 12-month follow-up. The estimated study completion is 2025. CONCLUSIONS: The registry will collect pre-, peri-, postoperative and 12-months data on patients undergoing repeated TAVI procedures with THVs for failure of the index THV and determine VARC-3-defined efficacy and safety at 30 days and functional outcome at 12 months. The registry will expand existing data sets and identify patient characteristics/indicators related to complications and clinical benefits for patients with symptomatic severe calcific degenerative aortic stenosis.

6.
Circulation ; 146(5): 383-397, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35722876

RESUMO

BACKGROUND: Cerebral microbleeds (CMBs) have been observed in healthy elderly people undergoing systematic brain magnetic resonance imaging. The potential role of acute triggers on the appearance of CMBs remains unknown. We aimed to describe the incidence of new CMBs after transcatheter aortic valve replacement (TAVR) and to identify clinical and procedural factors associated with new CMBs including hemostatic measures and anticoagulation management. METHODS: We evaluated a prospective cohort of patients with symptomatic aortic stenosis referred for TAVR for CMBs (METHYSTROKE [Identification of Epigenetic Risk Factors for Ischemic Complication During the TAVR Procedure in the Elderly]). Standardized neurologic assessment, brain magnetic resonance imaging, and analysis of hemostatic measures including von Willebrand factor were performed before and after TAVR. Numbers and location of microbleeds on preprocedural magnetic resonance imaging and of new microbleeds on postprocedural magnetic resonance imaging were reported by 2 independent neuroradiologists blinded to clinical data. Measures associated with new microbleeds and postprocedural outcome including neurologic functional outcome at 6 months were also examined. RESULTS: A total of 84 patients (47% men, 80.9±5.7 years of age) were included. On preprocedural magnetic resonance imaging, 22 patients (26% [95% CI, 17%-37%]) had at least 1 microbleed. After TAVR, new microbleeds were observed in 19 (23% [95% CI, 14%-33%]) patients. The occurrence of new microbleeds was independent of the presence of microbleeds at baseline and of diffusion-weighted imaging hypersignals. In univariable analysis, a previous history of bleeding (P=0.01), a higher total dose of heparin (P=0.02), a prolonged procedure (P=0.03), absence of protamine reversion (P=0.04), higher final activated partial thromboplastin time (P=0.05), lower final von Willebrand factor high-molecular-weight:multimer ratio (P=0.007), and lower final closure time with adenosine-diphosphate (P=0.02) were associated with the occurrence of new postprocedural microbleeds. In multivariable analysis, a prolonged procedure (odds ratio, 1.22 [95% CI, 1.03-1.73] for every 5 minutes of fluoroscopy time; P=0.02) and postprocedural acquired von Willebrand factor defect (odds ratio, 1.42 [95% CI, 1.08-1.89] for every lower 0.1 unit of high-molecular-weight:multimer ratio; P=0.004) were independently associated with the occurrence of new postprocedural microbleeds. New CMBs were not associated with changes in neurologic functional outcome or quality of life at 6 months. CONCLUSIONS: One out of 4 patients undergoing TAVR has CMBs before the procedure and 1 out of 4 patients develops new CMBs. Procedural or antithrombotic management and persistence of acquired von Willebrand factor defect were associated with the occurrence of new CMBs. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02972008.


Assuntos
Hemorragia Cerebral , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/epidemiologia , Hemorragia Cerebral/etiologia , Feminino , Fluoroscopia , Hemostáticos , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Qualidade de Vida , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Fator de von Willebrand
7.
Am Heart J ; 260: 1-8, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36796573

RESUMO

BACKGROUND: Physiological assessment of intermediate coronary lesions to guide coronary revascularization is currently recommended by international guidelines. Vessel fractional flow reserve (vFFR) has emerged as a new approach to derive fractional flow reserve (FFR) from 3D-quantitative coronary angiography (3D-QCA) without the need for hyperemic agents or pressure wires. STUDY DESIGN AND OBJECTIVES: The FAST III is an investigator-initiated, open label, multicenter randomized trial comparing vFFR guided versus FFR guided coronary revascularization in approximately 2228 patients with intermediate coronary lesions (defined as 30%-80% stenosis by visual assessment or QCA). Intermediate lesions are physiologically assessed using on-line vFFR or FFR and treated if vFFR or FFR ≤0.80. The primary end point is a composite of all-cause death, any myocardial infarction, or any revascularization at 1-year post-randomization. Secondary end points include the individual components of the primary end point and cost-effectiveness will be investigated. CONCLUSIONS: FAST III is the first randomized trial to explore whether a vFFR guided revascularization strategy is non-inferior to an FFR guided strategy in terms of clinical outcomes at 1-year follow-up in patients with intermediate coronary artery lesions.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Angiografia Coronária , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Estudos Prospectivos , Seguimentos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia
8.
Am Heart J ; 256: 139-147, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36410441

RESUMO

BACKGROUND: Surgical aortic valve bioprostheses may degenerate over time and require redo intervention. Transcatheter aortic valve replacement (TAVR) is a less invasive alternative to redo surgery. The BAlloon Expandable vs. SElf Expanding Transcatheter VaLve for Degenerated BioprosthesIs (BASELINE) trial was designed to compare the performance of the balloon-expandable SAPIEN-3 Ultra and the self-expanding EVOLUT PRO+ valve systems in symptomatic patients with a failing surgical bioprosthesis. METHODS: The BASELINE trial is an investigator-initiated, non-funded, prospective, randomized, open-label, superiority trial enrolling a total of 440 patients in up to 50 sites in 12 countries in Europe and North-America. The primary endpoint is device success at 30-days defined by the Valve Academic Research Consortium-3 Criteria as the composite of technical success, freedom from mortality, freedom for surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication with an intended performance of the valve (mean gradient <20 mmHg and less than moderate aortic regurgitation). The co-primary endpoint at 1 year is defined as the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems. Independent Core Laboratories will conduct uniform analyses of echocardiography (pre-, post-, 1-year post-procedure), multi-sliced computed tomography (pre-, and if available post-procedure) and cine-fluoroscopy studies. CONCLUSIONS: The BASELINE trial is a head-to-head comparative trial investigating the 2 most used contemporary transcatheter heart valves for the treatment of a failing surgical aortic bioprosthesis. (ClinicalTrials.gov number NCT04843072).


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos
9.
Eur Heart J ; 43(29): 2783-2797, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35583186

RESUMO

AIMS: The respective roles of oral anticoagulation or antiplatelet therapy following transcatheter aortic valve implantation (TAVI) remain debated. ATLANTIS is an international, randomized, open-label, superiority trial comparing apixaban to the standard of care. METHODS AND RESULTS: After successful TAVI, 1500 patients were randomized (1:1) to receive apixaban 5 mg (2.5 mg if impaired renal function or concomitant antiplatelet therapy) (n = 749) twice daily, or standard of care (n = 751). Randomization was stratified by the need for chronic anticoagulation therapy. Standard-of-care patients received a vitamin K antagonist (VKA) (Stratum 1) or antiplatelet therapy (Stratum 2) if there was an indication for anticoagulation or not, respectively. The primary endpoint was the composite of death, myocardial infarction, stroke or transient ischaemic attack, systemic embolism, intracardiac or bioprosthesis thrombosis, deep vein thrombosis or pulmonary embolism, and life-threatening, disabling, or major bleeding over 1-year follow-up. The primary safety endpoint was major, disabling, or life-threatening bleeding. The primary outcome occurred in 138 (18.4%) and 151 (20.1%) patients receiving apixaban or standard of care, respectively [hazard ratio (HR) 0.92; 95% confidence interval (CI) 0.73-1.16] and there was no evidence of interaction between treatment and stratum (Pinteraction = 0.57). The primary safety endpoint was similar in both groups (HR 1.02; 95% CI 0.72-1.44). In Stratum 1 (n = 451), an exploratory analysis showed no difference for all endpoints between apixaban and VKA. In Stratum 2 (n = 1049), the primary outcome and primary safety endpoint did not differ, but obstructive valve thrombosis was reduced with apixaban vs. antiplatelet therapy (HR 0.19; 95% CI 0.08-0.46), while a signal of higher non-cardiovascular mortality was observed with apixaban. CONCLUSION: After TAVI, apixaban was not superior to the standard of care, irrespective of an indication for oral anticoagulation.


Assuntos
Trombose , Substituição da Valva Aórtica Transcateter , Anticoagulantes/uso terapêutico , Valva Aórtica/cirurgia , Fibrinolíticos , Hemorragia/induzido quimicamente , Humanos , Inibidores da Agregação Plaquetária/uso terapêutico , Padrão de Cuidado , Trombose/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Circulation ; 143(10): 1043-1061, 2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33683945

RESUMO

After 15 years of successive randomized, controlled trials, indications for transcatheter aortic valve replacement (TAVR) are rapidly expanding. In the coming years, this procedure could become the first line treatment for patients with a symptomatic severe aortic stenosis and a tricuspid aortic valve anatomy. However, randomized, controlled trials have excluded bicuspid aortic valve (BAV), which is the most frequent congenital heart disease occurring in 1% to 2% of the total population and representing at least 25% of patients 80 years of age or older referred for aortic valve replacement. The use of a less invasive transcatheter therapy in this elderly population became rapidly attractive, and approximately 10% of patients currently undergoing TAVR have a BAV. The U.S. Food and Drug Administration and the "European Conformity" have approved TAVR for low-risk patients regardless of the aortic valve anatomy whereas international guidelines recommend surgical replacement in BAV populations. Given this progressive expansion of TAVR toward younger and lower-risk patients, heart teams are encountering BAV patients more frequently, while the ability of this therapy to treat such a challenging anatomy remains uncertain. This review will address the singularity of BAV anatomy and associated technical challenges for the TAVR procedure. We will examine and summarize available clinical evidence and highlight critical knowledge gaps regarding TAVR utilization in BAV patients. We will provide a comprehensive overview of the role of computed tomography scans in the diagnosis, and classification of BAV and TAVR procedure planning. Overall, we will offer an integrated framework for understanding the current role of TAVR in the treatment of bicuspid aortic stenosis and for guiding physicians in clinical decision-making.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
11.
Catheter Cardiovasc Interv ; 99(7): 2117-2124, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35395142

RESUMO

Rescue transcatheter aortic valve replacement (TAVR) in patients with cardiogenic shock is challenging, and there is limited literature on these critical patients. The aim of this study was to determine the characteristics and outcomes of patients undergoing TAVR, feasibility and safety of the procedure, and 1-year mortality factors. Thirty-eight patients with severe aortic disease and cardiogenic shock admitted to two French hospitals from 2015 to 2019 were included. The patients were critical, 78.9% of them had a left ventricular ejection fraction of <30%, and all of them received inotropic support. "Valve-in-valve" procedures were performed in 15.8% and 13.2% underwent balloon aortic valvuloplasty before TAVR. Edwards Sapien3® and Medtronic CoreValve EvolutR® were used. The survival probability remained reasonable for patients with cardiogenic shock who underwent rescue TAVR. The 30-day mortality rate was 7.9% and 21.1% at 1 year. No patient died during the intervention. The procedure was safe, with few complications except for acute kidney failure, the development of a left bundle branch block, and the need for pacemaker implantation. Both functional and echocardiographic results were good at 1 year, although 29% of the patients underwent rehospitalization within 1 year. The development of a left bundle branch block was found to be a mortality risk factor. This procedure is a safe and effective therapy with acceptable survivorship in critically ill patients. The benefits to their quality of life should be evaluated in future studies, and the need for providing early cardiac resynchronization therapy must be emphasized.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Arritmias Cardíacas , Bloqueio de Ramo/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Qualidade de Vida , Estudos Retrospectivos , Fatores de Risco , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
12.
Arterioscler Thromb Vasc Biol ; 41(1): 415-429, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33147990

RESUMO

OBJECTIVE: The study's aim was to analyze the capacity of human valve interstitial cells (VICs) to participate in aortic valve angiogenesis. Approach and Results: VICs were isolated from human aortic valves obtained after surgery for calcific aortic valve disease and from normal aortic valves unsuitable for grafting (control VICs). We examined VIC in vitro and in vivo potential to differentiate in endothelial and perivascular lineages. VIC paracrine effect was also examined on human endothelial colony-forming cells. A pathological VIC (VICp) mesenchymal-like phenotype was confirmed by CD90+/CD73+/CD44+ expression and multipotent-like differentiation ability. When VICp were cocultured with endothelial colony-forming cells, they formed microvessels by differentiating into perivascular cells both in vivo and in vitro. VICp and control VIC conditioned media were compared using serial ELISA regarding quantification of endothelial and angiogenic factors. Higher expression of VEGF (vascular endothelial growth factor)-A was observed at the protein level in VICp-conditioned media and confirmed at the mRNA level in VICp compared with control VIC. Conditioned media from VICp induced in vitro a significant increase in endothelial colony-forming cell proliferation, migration, and sprouting compared with conditioned media from control VIC. These effects were inhibited by blocking VEGF-A with blocking antibody or siRNA approach, confirming VICp involvement in angiogenesis by a VEGF-A dependent mechanism. CONCLUSIONS: We provide here the first proof of an angiogenic potential of human VICs isolated from patients with calcific aortic valve disease. These results point to a novel function of VICp in valve vascularization during calcific aortic valve disease, with a perivascular differentiation ability and a VEGF-A paracrine effect. Targeting perivascular differentiation and VEGF-A to slow calcific aortic valve disease progression warrants further investigation.


Assuntos
Estenose da Valva Aórtica/metabolismo , Valva Aórtica/metabolismo , Valva Aórtica/patologia , Calcinose/metabolismo , Diferenciação Celular , Linhagem da Célula , Células Progenitoras Endoteliais/metabolismo , Neovascularização Patológica , Fator A de Crescimento do Endotélio Vascular/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Estenose da Valva Aórtica/patologia , Calcinose/patologia , Estudos de Casos e Controles , Células Cultivadas , Técnicas de Cocultura , Células Progenitoras Endoteliais/patologia , Células Progenitoras Endoteliais/transplante , Feminino , Humanos , Masculino , Camundongos Nus , Pessoa de Meia-Idade , Osteogênese , Comunicação Parácrina , Fenótipo , Transdução de Sinais , Fator A de Crescimento do Endotélio Vascular/genética
13.
Eur Heart J ; 42(23): 2265-2269, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-33822924

RESUMO

Transcatheter aortic valve implantation (TAVI) is effective in older patients with symptomatic severe aortic stenosis, while the indication has recently broadened to younger patients at lower risk. Although thromboembolic and bleeding complications after TAVI have decreased over time, such adverse events are still common. The recommendations of the latest 2017 ESC/EACTS Guidelines for the management of valvular heart disease on antithrombotic therapy in patients undergoing TAVI are mostly based on expert opinion. Based on recent studies and randomized controlled trials, this viewpoint document provides updated therapeutic insights in antithrombotic treatment during and after TAVI.


Assuntos
Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Trombose , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/tratamento farmacológico , Estenose da Valva Aórtica/cirurgia , Consenso , Fibrinolíticos/uso terapêutico , Humanos , Trombose/tratamento farmacológico , Trombose/etiologia , Trombose/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Int J Mol Sci ; 23(10)2022 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-35628113

RESUMO

Transcatheter aortic valve replacement (TAVR), as an alternative to open heart surgery, has revolutionized the treatment of severe aortic valve stenosis (AVS), the most common valvular disorder in the elderly. AVS is now considered a form of atherosclerosis and, like the latter, partly of inflammatory origin. Patients with high-grade AVS have a highly disturbed blood flow associated with high levels of shear stress. The immediate reopening of the valve during TAVR leads to a sudden restoration of a normal blood flow hemodynamic. Despite its good prognosis for patients, TAVR remains associated with bleeding or thrombotic postprocedural complications, involving mechanisms that are still poorly understood. Many studies report the close link between blood coagulation and inflammation, termed thromboinflammation, including monocytes as a major actor. The TAVR procedure represents a unique opportunity to study the influence of shear stress on human monocytes, key mediators of inflammation and hemostasis processes. The purpose of this study was to conduct a review of the literature to provide a comprehensive overview of the impact of TAVR on monocyte phenotype and subset repartition and the association of these parameters with the clinical outcomes of patients with severe AVS who underwent TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Idoso , Estenose da Valva Aórtica/etiologia , Humanos , Inflamação/etiologia , Monócitos , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
15.
Circulation ; 142(25): 2431-2442, 2020 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-33054367

RESUMO

BACKGROUND: Few randomized trials have compared bioprostheses for transcatheter aortic valve replacement, and no trials have compared bioprostheses with supra-annular design. The SCOPE 2 trial (Safety and Efficacy Comparison of Two TAVI Systems in a Prospective Randomized Evaluation 2) was designed to compare the clinical outcomes of the ACURATE neo and CoreValve Evolut bioprostheses for transcatheter aortic valve replacement. METHODS: SCOPE 2 was a randomized trial performed at 23 centers in 6 countries between April 2017 and April 2019. Patients ≥75 years old with an indication for transfemoral transcatheter aortic valve replacement as agreed by the heart team were randomly assigned to receive treatment with either the ACURATE neo (n=398) or the CoreValve Evolut bioprostheses (n=398). The primary end point, powered for noninferiority of the ACURATE neo bioprosthesis, was all-cause death or stroke at 1 year. The key secondary end point, powered for superiority of the ACURATE neo bioprosthesis, was new permanent pacemaker implantation at 30 days. RESULTS: Among 796 randomized patients (mean age, 83.2±4.3 years; mean Society of Thoracic Surgeons Predicted Risk of Mortality score, 4.6±2.9%), clinical follow-up information was available for 778 (98%) patients. Within 1 year, the primary end point occurred in 15.8% of patients in the ACURATE neo group and in 13.9% of patients in the CoreValve Evolut group (absolute risk difference, 1.8%, upper 1-sided 95% confidence limit, 6.1%; P=0.0549 for noninferiority). The 30-day rates of new permanent pacemaker implantation were 10.5% in the ACURATE neo group and 18.0% in the CoreValve Evolut group (absolute risk difference, -7.5% [95% CI, -12.4 to -2.60]; P=0.0027). No significant differences were observed in the components of the primary end point. Cardiac death at 30 days (2.8% versus 0.8%; P=0.03) and 1 year (8.4% versus 3.9%; P=0.01), and moderate or severe aortic regurgitation at 30 days (10% versus 3%; P=0.002) were significantly increased in the ACURATE neo group. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement with the self-expanding ACURATE neo did not meet noninferiority compared with the self-expanding CoreValve Evolut in terms of all-cause death or stroke at 1 year, and it was associated with a lower incidence of new permanent pacemaker implantation. In secondary analyses, the ACURATE neo was associated with more moderate or severe aortic regurgitation at 30 days and cardiac death at 30 days and 1 year. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03192813.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Europa (Continente) , Feminino , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
16.
Circulation ; 141(4): 243-259, 2020 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-31736356

RESUMO

BACKGROUND: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. METHODS: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. RESULTS: In propensity-matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46-1.91]; P<0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63-2.22]; P<0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07-1.66]; P=0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06-1.29]; P=0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. CONCLUSION: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov. Unique identifier: NCT01777828.


Assuntos
Próteses Valvulares Cardíacas , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Intervalo Livre de Doença , Feminino , Seguimentos , França/epidemiologia , Humanos , Masculino , Taxa de Sobrevida
17.
Catheter Cardiovasc Interv ; 97(5): 959-961, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33001555

RESUMO

High-risk transcatheter procedures requiring hemodynamic support are growing and require multiple vascular access that may be challenging in cases of peripheral artery disease or lack of radial access and exposure to a higher risk of vascular complications. We report the novel utilization of a Y-shaped arterial extracorporeal membrane oxygenation (ECMO) cannula used as a single femoral access to perform percutaneous coronary intervention (PCI) and aortography during high-risk transcatheter aortic valve replacement (TAVR). The utilization of this 2-in-1 ECMO cannula may simplify vascular access and reduce vascular and bleeding complications during high-risk ECMO-supported transcatheter procedures.


Assuntos
Estenose da Valva Aórtica , Oxigenação por Membrana Extracorpórea , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/cirurgia , Cânula , Oxigenação por Membrana Extracorpórea/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
19.
N Engl J Med ; 376(19): 1824-1834, 2017 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-28317458

RESUMO

BACKGROUND: Coronary revascularization guided by fractional flow reserve (FFR) is associated with better patient outcomes after the procedure than revascularization guided by angiography alone. It is unknown whether the instantaneous wave-free ratio (iFR), an alternative measure that does not require the administration of adenosine, will offer benefits similar to those of FFR. METHODS: We randomly assigned 2492 patients with coronary artery disease, in a 1:1 ratio, to undergo either iFR-guided or FFR-guided coronary revascularization. The primary end point was the 1-year risk of major adverse cardiac events, which were a composite of death from any cause, nonfatal myocardial infarction, or unplanned revascularization. The trial was designed to show the noninferiority of iFR to FFR, with a margin of 3.4 percentage points for the difference in risk. RESULTS: At 1 year, the primary end point had occurred in 78 of 1148 patients (6.8%) in the iFR group and in 83 of 1182 patients (7.0%) in the FFR group (difference in risk, -0.2 percentage points; 95% confidence interval [CI], -2.3 to 1.8; P<0.001 for noninferiority; hazard ratio, 0.95; 95% CI, 0.68 to 1.33; P=0.78). The risk of each component of the primary end point and of death from cardiovascular or noncardiovascular causes did not differ significantly between the groups. The number of patients who had adverse procedural symptoms and clinical signs was significantly lower in the iFR group than in the FFR group (39 patients [3.1%] vs. 385 patients [30.8%], P<0.001), and the median procedural time was significantly shorter (40.5 minutes vs. 45.0 minutes, P=0.001). CONCLUSIONS: Coronary revascularization guided by iFR was noninferior to revascularization guided by FFR with respect to the risk of major adverse cardiac events at 1 year. The rate of adverse procedural signs and symptoms was lower and the procedural time was shorter with iFR than with FFR. (Funded by Philips Volcano; DEFINE-FLAIR ClinicalTrials.gov number, NCT02053038 .).


Assuntos
Síndrome Coronariana Aguda/fisiopatologia , Estenose Coronária/fisiopatologia , Estenose Coronária/terapia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea/métodos , Síndrome Coronariana Aguda/diagnóstico por imagem , Idoso , Angina Pectoris/diagnóstico por imagem , Angina Pectoris/fisiopatologia , Doenças Cardiovasculares/mortalidade , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Retratamento , Índice de Gravidade de Doença
20.
Catheter Cardiovasc Interv ; 96(4): 930-939, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31794159

RESUMO

BACKGROUND: The SAPIEN 3 (S3) addresses several limitations of the SAPIEN XT (SXT) for the performance of transfemoral (TF-) balloon expandable transcatheter aortic valve implantation (TAVI). OBJECTIVES: We aimed to determine whether their altered features translate into improved outcomes in a real-world TF-TAVI patient population. METHODS: Data for 3,314 patients were extracted from the European registries SOURCE-XT and SOURCE-3. Patients were propensity-score (PS) matched (n = 1,169/group). RESULTS: In the PS matched comparison, device success was higher in the S3 (99.2%) compared to the SXT group (98.2%; p = .04). S3 patients experienced a lower rate of procedural death (0.7 vs. 2.6%; p = .0004), moderate/severe paravalvular leakage (PVL; 1.4 vs. 5.5%; p < .0001), and procedure-related stroke (1.2 vs. 2.4%; p = .04) while higher rates of mean aortic valve gradients ≥20 mmHg, and new permanent pacemaker implantations were seen. At 30 days a lower rate of all-cause mortality was seen (2.1% vs. 4.3%; p = .003), which was preserved after 1 year (10.7% vs. 14.9%; p = .002). A Cox regression predicting 1-year mortality resulted in a hazard ratio of 0.684 in favor of S3 (p = .0026). The same was true of stroke (2.8% vs. 5.7%; p = .0007), and moderate/severe PVL (2.7 vs. 7.3%; p = .0002) at 1 year. The rate of new pacemaker implantations (13.6% vs. 9.5%; p = .001) and NYHA III/IV (12.8 vs. 8.6%; p = .004) was higher with the S3. CONCLUSIONS: The improved features of the S3 appear to translate into improved survival and reduced rates of adverse complications, with the exception of a higher rate of new pacemaker implantations.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Europa (Continente) , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA