1.
J Neuroradiol ; 51(2): 210-213, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37499791

RESUMO

We propose a modified dynamic CT-myelography technique for patients with fast CSF leaks caused by ventral dural tears in order to reduce radiation exposure and complications. A fluoroscopy-guided lumbar puncture using an epidural anesthesia kit replaces a CT-guided lumbar puncture, and a smaller volume of less concentrated contrast media is used. This approach has advantages, including speeding up the procedure, reduced radiation exposure, and elimination of the risk of contrast injection into the epidural space.


Assuntos
Hipotensão Intracraniana , Humanos , Hipotensão Intracraniana/diagnóstico por imagem , Hipotensão Intracraniana/complicações , Vazamento de Líquido Cefalorraquidiano/complicações , Vazamento de Líquido Cefalorraquidiano/diagnóstico , Mielografia/efeitos adversos , Mielografia/métodos , Tomografia Computadorizada por Raios X/métodos , Fluoroscopia/efeitos adversos
2.
MAGMA ; 36(2): 295-308, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37072539

RESUMO

OBJECTIVE: Wall shear stress (WSS) and its derived spatiotemporal parameters have proven to play a major role on intracranial aneurysms (IAs) growth and rupture. This study aims to demonstrate how ultra-high field (UHF) 7 T phase contrast magnetic resonance imaging (PC-MRI) coupled with advanced image acceleration techniques allows a highly resolved visualization of near-wall hemodynamic parameters patterns in in vitro IAs, paving the way for more robust risk assessment of their growth and rupture. MATERIALS AND METHODS: We performed pulsatile flow measurements inside three in vitro models of patient-specific IAs using 7 T PC-MRI. To this end, we built an MRI-compatible test bench, which faithfully reproduced a typical physiological intracranial flow rate in the models. RESULTS: The ultra-high field 7 T images revealed WSS patterns with high spatiotemporal resolution. Interestingly, the high oscillatory shear index values were found in the core of low WSS vortical structures and in flow stream intersecting regions. In contrast, maxima of WSS occurred around the impinging jet sites. CONCLUSIONS: We showed that the elevated signal-to-noise ratio arising from 7 T PC-MRI enabled to resolve high and low WSS patterns with a high degree of detail.


Assuntos
Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Hemodinâmica , Estresse Mecânico
3.
J Med Virol ; 93(7): 4374-4381, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33782993

RESUMO

Severe acute respiratory coronavirus 2 (SARS-CoV-2) has been associated with neurological complications, including acute encephalopathy. To better understand the neuropathogenesis of this acute encephalopathy, we describe a series of patients with coronavirus disease 2019 (COVID-19) encephalopathy, highlighting its phenomenology and its neurobiological features. On May 10, 2020, 707 patients infected by SARS-CoV-2 were hospitalized at the Geneva University Hospitals; 31 (4.4%) consecutive patients with an acute encephalopathy (64.6 ± 12.1 years; 6.5% female) were included in this series, after exclusion of comorbid neurological conditions, such as stroke or meningitis. The severity of the COVID-19 encephalopathy was divided into severe and mild based on the Richmond Agitation Sedation Scale (RASS): severe cases (n = 14, 45.2%) were defined on a RASS < -3 at worst presentation. The severe form of this so-called COVID-19 encephalopathy presented more often a headache. The severity of the pneumonia was not associated with the severity of the COVID-19 encephalopathy: 28 of 31 (90%) patients did develop an acute respiratory distress syndrome, without any difference between groups (p = .665). Magnetic resonance imaging abnormalities were found in 92.0% (23 of 25 patients) with an intracranial vessel gadolinium enhancement in 85.0% (17 of 20 patients), while an increased cerebrospinal fluid/serum quotient of albumin suggestive of blood-brain barrier disruption was reported in 85.7% (6 of 7 patients). Reverse transcription-polymerase chain reaction for SARS-CoV-2 was negative for all patients in the cerebrospinal fluid. Although different pathophysiological mechanisms may contribute to this acute encephalopathy, our findings suggest the hypothesis of disturbed brain homeostasis and vascular dysfunction consistent with a SARS-CoV-2-induced endotheliitis.


Assuntos
Encefalopatias/patologia , Encefalopatias/virologia , Encéfalo/patologia , COVID-19/patologia , Idoso , Albuminas/líquido cefalorraquidiano , Eletroencefalografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , SARS-CoV-2 , Índice de Gravidade de Doença , Suíça
4.
Can J Neurol Sci ; 48(2): 218-225, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32799939

RESUMO

OBJECTIVES: Embolic ischemic strokes cause significant mortality and morbidity worldwide. It has been proposed that some of these strokes are due to unstable carotid plaques with intraplaque hemorrhage (IPH) but a low overall degree of stenosis. Our aim was to test a fat-saturated T1-weighted (T1WI) black-blood sequence on MRI for the detection of IPH in symptomatic individuals and to quantify the relation between IPH, severity of stenoses, and ischemic brain lesions. MATERIALS AND METHODS: Sixty-two patients were examined by 3T MRI. Sequences included brain diffusion-weighted imaging (DWI) as well as 3D turbo spin echo (TSE) fat-saturated black-blood T1 of the carotid bifurcations, to detect IPH as a focal intraplaque hyperintensity. Both carotid arteries were analyzed in each patient. The North American Symptomatic Carotid Endarterectomy Trial scale was used for quantification of stenosis degree. RESULTS: Thirty-six out of 62 patients (mean age, 74) showed brain ischemia on DWI. Fifteen of these 36 patients (42%) had associated ipsilateral IPH at the carotid bifurcation or the proximal internal carotid artery. Mean degree of stenosis in this group was 50%. In 21 patients with ischemia without IPH, the mean degree of stenosis was 44%. CONCLUSIONS: MRI with 3D TSE fat-saturated black-blood T1 technique is a safe, reliable, and noninvasive tool for the detection of IPH. A high percentage (42%) of ischemic events in patients with low- to moderate-degree stenosis were associated with IPH, an easily detectable imaging biomarker of plaque vulnerability. The ability to confirm IPH by MRI may help stratify patients into different risk and treatment groups in the future.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Placa Aterosclerótica , Acidente Vascular Cerebral , Idoso , Artérias Carótidas , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Hemorragia , Humanos , Imageamento por Ressonância Magnética , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico por imagem , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico por imagem
5.
BMC Geriatr ; 21(1): 52, 2021 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-33446113

RESUMO

BACKGROUND: Stroke in the course of coronavirus disease (COVID-19) has been shown to be associated with more severe respiratory symptoms and higher mortality, but little knowledge in this regard exists on older populations. We aimed to investigate the incidence, characteristics, and prognosis of acute stroke in geriatric patients hospitalized with COVID-19. METHODS: A monocentric cross-sectional retrospective study of 265 older patients hospitalized with COVID-19 on acute geriatric wards. 11/265 presented a stroke episode during hospitalization. Mortality rates and two-group comparisons (stroke vs non-stroke patients) were calculated and significant variables added in logistic regression models to investigate stroke risk factors. RESULTS: Combined ischemic and hemorrhagic stroke incidence was 4.15%. 72.7% of events occurred during acute care. Strokes presented with altered state of consciousness and/or delirium in 81.8%, followed by a focal neurological deficit in 45.5%. Ischemic stroke was more frequently unilateral (88.8%) and localized in the middle cerebral artery territory (55.5%). Smoking and a history of previous stroke increased by more than seven (OR 7.44; 95% CI 1.75-31.64; p = 0.007) and five times (OR 5.19; 95% CI 1.50-17.92; p = 0.009), respectively, the risk of stroke. Each additional point in body mass index (BMI) reduced the risk of stroke by 14% (OR 0.86; 95% CI 0.74-0.98; p = 0.03). In-hospital mortality (32.1% vs. 27.3%; p > 0.999) and institutionalization at discharge (36.4% vs. 21.1%; p = 0.258) were similar between patients with and without stroke. CONCLUSION: Incident stroke complicating COVID-19 in old patients was associated with active smoking, previous history of stroke, and low BMI. Acute stroke did not influence early mortality or institutionalization rate at discharge.


Assuntos
COVID-19 , Coronavirus , Acidente Vascular Cerebral , Idoso , Estudos Transversais , Humanos , Incidência , Estudos Retrospectivos , Fatores de Risco , SARS-CoV-2 , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia
6.
Acta Neurochir (Wien) ; 163(1): 67-71, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32901397

RESUMO

Intracranial meningiomas mostly affect patients in their fifth decade and beyond, raising pertinent questions regarding the risk of surgery, particularly in the elderly. Here, we describe the case of a septuagenarian patient with occipital meningioma causing severe visual field cuts that experienced full recovery of the visual function after a Simpson I resection of the lesion. This case illustrates the potential of recovery of the brain, even in the case of severely impaired function in elderly patients. To complete the picture, we review the literature on occipital meningiomas, advocating for systematic reports and increase data collection on post-operative neurological recovery in the elderly.


Assuntos
Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Lobo Occipital/cirurgia , Campos Visuais , Idoso , Humanos , Masculino , Procedimentos Neurocirúrgicos/métodos , Lobo Occipital/patologia
7.
Ideggyogy Sz ; 74(3-4): 126-128, 2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33938666

RESUMO

The subtypes of brain arteriovenous malformations, with direct, single-hole fistulas without co-existing nidus are not described as existing entities inside the brain parenchyma but on the pial surface. True parenchymal arteriovenous malformations present with nidal structure, even if they are small, whereas surface lesions may present a direct fistulous configuration. In this case of midbrain haemorrhage a direct arteriovenous fistula was detected at the level of the red nucleus between a paramedian midbrain perforator artery and a paramedian parenchymal vein, with pseudo-aneurysm formation at the fistulous connection, without signs of adjacent nidus structure. The hypothesis whether a pre-existing arteriovenous fistula ruptured or a spontaneous haemorrhage has caused the fistulous connection is discussed.


Assuntos
Fístula Arteriovenosa , Malformações Arteriovenosas Intracranianas , Fístula Arteriovenosa/complicações , Fístula Arteriovenosa/diagnóstico por imagem , Encéfalo , Humanos , Malformações Arteriovenosas Intracranianas/complicações , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Mesencéfalo
8.
Stroke ; 51(8): 2488-2494, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32684141

RESUMO

BACKGROUND AND PURPOSE: Mechanical thrombectomy (MTB) is a reference treatment for acute ischemic stroke, with several endovascular strategies currently available. However, no quantitative methods are available for the selection of the best endovascular strategy or to predict the difficulty of clot removal. We aimed to investigate the predictive value of an endovascular strategy based on radiomic features extracted from the clot on preinterventional, noncontrast computed tomography to identify patients with first-attempt recanalization with thromboaspiration and to predict the overall number of passages needed with an MTB device for successful recanalization. METHODS: We performed a study including 2 cohorts of patients admitted to our hospital: a retrospective training cohort (n=109) and a prospective validation cohort (n=47). Thrombi were segmented on noncontrast computed tomography, followed by the automatic computation of 1485 thrombus-related radiomic features. After selection of the relevant features, 2 machine learning models were developed on the training cohort to predict (1) first-attempt recanalization with thromboaspiration and (2) the overall number of passages with MTB devices for successful recanalization. The performance of the models was evaluated on the prospective validation cohort. RESULTS: A small subset of radiomic features (n=9) was predictive of first-attempt recanalization with thromboaspiration (receiver operating characteristic curve-area under the curve, 0.88). The same subset also predicted the overall number of passages required for successful recanalization (explained variance, 0.70; mean squared error, 0.76; Pearson correlation coefficient, 0.73; P<0.05). CONCLUSIONS: Clot-based radiomics have the ability to predict an MTB strategy for successful recanalization in acute ischemic stroke, thus allowing a potentially better selection of the MTB strategy, as well as patients who are most likely to benefit from the intervention.


Assuntos
Isquemia Encefálica/cirurgia , Revascularização Cerebral/métodos , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Trombose/cirurgia , Idoso , Isquemia Encefálica/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Trombose/diagnóstico por imagem , Resultado do Tratamento
9.
Eur Radiol ; 30(1): 308-319, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31264014

RESUMO

OBJECTIVES: The aim was to evaluate the image quality and sensitivity to artifacts of compressed sensing (CS) acceleration technique, applied to 3D or breath-hold sequences in different clinical applications from brain to knee. METHODS: CS with an acceleration from 30 to 60% and conventional MRI sequences were performed in 10 different applications in 107 patients, leading to 120 comparisons. Readers were blinded to the technique for quantitative (contrast-to-noise ratio or functional measurements for cardiac cine) and qualitative (image quality, artifacts, diagnostic findings, and preference) image analyses. RESULTS: No statistically significant difference in image quality or artifacts was found for each sequence except for the cardiac cine CS for one of both readers and for the wrist 3D proton density (PD)-weighted CS sequence which showed less motion artifacts due to the reduced acquisition time. The contrast-to-noise ratio was lower for the elbow CS sequence but not statistically different in all other applications. Diagnostic findings were similar between conventional and CS sequence for all the comparisons except for four cases where motion artifacts corrupted either the conventional or the CS sequence. CONCLUSIONS: The evaluated CS sequences are ready to be used in clinical daily practice except for the elbow application which requires a lower acceleration. The CS factor should be tuned for each organ and sequence to obtain good image quality. It leads to 30% to 60% acceleration in the applications evaluated in this study which has a significant impact on clinical workflow. KEY POINTS: • Clinical implementation of compressed sensing (CS) reduced scan times of at least 30% with only minor penalty in image quality and no change in diagnostic findings. • The CS acceleration factor has to be tuned separately for each organ and sequence to guarantee similar image quality than conventional acquisition. • At least 30% and up to 60% acceleration is feasible in specific sequences in clinical routine.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Abdome/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Encéfalo/diagnóstico por imagem , Feminino , Coração/diagnóstico por imagem , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Adulto Jovem
10.
Neuroradiology ; 62(6): 747-751, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32095870

RESUMO

In patients with parkinsonian syndromes, and particularly during the early stages of the clinical disease, differentiating between idiopathic Parkinson's disease and progressive supranuclear palsy is challenging. Imaging plays an important role in early diagnosis, and the magnetic resonance parkinsonism index was shown to reliably differentiate between the two entities. Calculation of the index is a time-consuming process. We developed an algorithm allowing its automatic calculation based on 3D T1-weighted images, producing additional color-coded images for verification.


Assuntos
Imageamento por Ressonância Magnética/métodos , Transtornos Parkinsonianos/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste , Diagnóstico Diferencial , Diagnóstico Precoce , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/diagnóstico por imagem , Paralisia Supranuclear Progressiva/diagnóstico por imagem
11.
Magn Reson Med ; 81(1): 560-572, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29893989

RESUMO

PURPOSE: The morphological and hemodynamic evaluations of neurovascular diseases treated with stents would benefit from noninvasive imaging techniques such as 3D time-of-flight MRI (3D-TOF) and 3D phase contrast MRI (3D-PCMRI). For this purpose, a comprehensive evaluation of the stent artifacts and their impact on the flow measurement is critical. METHODS: The artifacts of a representative sample of neurovascular stents were evaluated in vitro with 3D-TOF and 3D-PCMRI sequences. The dependency of the artifacts with respect to the orientation was analyzed for each stent design as well as the impact on the flow measurement accuracy. Furthermore, the 3D-PCMRI data of four patients carrying intracranial aneurysms treated with flow diverter stents were analyzed as illustrative examples. RESULTS: The stent artifacts were mainly confined to the stent lumen therefore indicating the leading role of shielding effect. The influence of the stent design and its orientation with respect to the transmitting MR coils were highlighted. The artifacts impacted the 3D-PCMRI velocities mainly in the low magnitude domains, which were discarded from the analysis ensuring reliable near-stent velocities. The feasibility of in-stent flow measurements was confirmed in vivo on two patients who showed strong correlation between flow and geometric features. In two other patients, the consistency of out-of-stent velocities was verified qualitatively through intra-aneurysmal streamlines except when susceptibility artifacts occurred. CONCLUSION: The present results motivate the conception of low inductance or nonconductive stent design. Furthermore, the feasibility of near-stent 3D-PCMRI measurements opens the door to clinical applications like the post-treatment follow-up of stenoses or intracranial aneurysms.


Assuntos
Aneurisma/diagnóstico por imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Neurônios/metabolismo , Stents , Algoritmos , Artefatos , Velocidade do Fluxo Sanguíneo , Vasos Sanguíneos/metabolismo , Circulação Cerebrovascular , Cromo/química , Cobalto/química , Hemodinâmica , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Teste de Materiais , Níquel/química , Reprodutibilidade dos Testes , Titânio/química , Procedimentos Cirúrgicos Vasculares/efeitos adversos
12.
Eur J Nucl Med Mol Imaging ; 46(9): 1806-1816, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31144060

RESUMO

PURPOSE: FDG PET is an established tool in presurgical epilepsy evaluation, but it is most often used selectively in patients with discordant MRI and EEG results. Interpretation is complicated by the presence of remote or multiple areas of hypometabolism, which leads to doubt as to the true location of the seizure onset zone (SOZ) and might have implications for predicting the surgical outcome. In the current study, we determined the sensitivity and specificity of PET localization prospectively in a consecutive unselected cohort of patients with focal epilepsy undergoing in-depth presurgical evaluation. METHODS: A total of 130 patients who underwent PET imaging between 2006 and 2015 matched our inclusion criteria, and of these, 86 were operated on (72% with a favourable surgical outcome, Engel class I). Areas of focal hypometabolism were identified using statistical parametric mapping and concordance with MRI, EEG and intracranial EEG was evaluated. In the surgically treated patients, postsurgical outcome was used as the gold standard for correctness of localization (minimum follow-up 12 months). RESULTS: PET sensitivity and specificity were both 95% in 86 patients with temporal lobe epilepsy (TLE) and 80% and 95%, respectively, in 44 patients with extratemporal epilepsy (ETLE). Significant extratemporal hypometabolism was observed in 17 TLE patients (20%). Temporal hypometabolism was observed in eight ETLE patients (18%). Among the 86 surgically treated patients, 26 (30%) had hypometabolism extending beyond the SOZ. The presence of unilobar hypometabolism, included in the resection, was predictive of complete seizure control (p = 0.007), with an odds ratio of 5.4. CONCLUSION: Additional hypometabolic areas were found in one of five of this group of nonselected patients with focal epilepsy, including patients with "simple" lesional epilepsy, and this finding should prompt further in-depth evaluation of the correlation between EEG findings, semiology and PET. Hypometabolism confined to the epileptogenic zone as defined by EEG and MRI is associated with a favourable postoperative outcome in both TLE and ETLE patients.


Assuntos
Epilepsias Parciais/metabolismo , Epilepsias Parciais/cirurgia , Valor Preditivo dos Testes , Adulto , Criança , Pré-Escolar , Estudos de Coortes , Eletroencefalografia , Epilepsias Parciais/diagnóstico por imagem , Feminino , Humanos , Lactente , Recém-Nascido , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
14.
J Neuroradiol ; 45(5): 305-309, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29410105

RESUMO

OBJECTIVE: Mechanical thrombectomy (MTB) is a treatment of reference for acute ischemic stroke due to large brain vessel occlusion but some concerns remain about its use in small distal branches. In the present study, we assessed the efficacy and the safety of distal MTB using the Catch Mini (CM) stent retriever. METHODS: We retrospectively reviewed a prospectively maintained database of all consecutive patients who underwent MTB for a distal intracranial occlusion with the Catch Mini device at our hospital. RESULTS: Forty-one patient underwent MTB for distal intracranial occlusions using the CM stent retriever. Good capillary reperfusion (TICT≥2b) was observed in 32 out of 41 patients (78%). Focal ischemia within the territory vascularized by the artery addressed by the CM was observed in 8 patients (19.5%). Post-procedural vasospasm was observed in 8 patients, all responding rapidly to vasodilatator administration. Two asymptomatic hemorrhages (4.9%) were noted on follow-up imaging (one patechial hemorrhage and one parenchymal hematoma) in patients with M2 occlusions. No vessel rupture were observed. Overall, good neurological outcome at three months (mRS≤2) was observed in 28 (out of 34 patients followed; 82.4%) of patients. CONCLUSIONS: Our single-center experience shows that the CM stent retriever is safe and effective for the recanalization of small diameter distal branches feeding eloquent brain areas.


Assuntos
Isquemia Encefálica/cirurgia , Remoção de Dispositivo/instrumentação , Stents , Acidente Vascular Cerebral/cirurgia , Trombectomia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Estudos Retrospectivos , Trombectomia/instrumentação , Resultado do Tratamento
15.
Eur Radiol ; 27(12): 5064-5072, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28639048

RESUMO

AIM: To evaluate brain atrophy in anorexic patients by automated cerebral segmentation with the magnetization-prepared 2 rapid acquisition gradient echo (MP2RAGE) MRI sequence. MATERIAL AND METHODS: Twenty patients (female; mean age, 27.9 years), presenting consecutively for brain MRI between August 2014-December 2016 with clinical suspicion of anorexia nervosa and BMI<18.5 kg/m2 were included. Controls were ten healthy females (mean age, 26.5 years). Automated brain morphometry was performed based on MP2RAGE. Means of morphometric results in the two groups were compared and correlation with BMI was analysed. RESULTS: Significantly lower volumes of total brain, grey matter (GM), white matter (WM), cerebellum and insula were found in anorexic patients. Anorexics had higher volumes of CSF, ventricles, lateral ventricles and third ventricle. When adjusted means for weight and height were compared, the volume of WM and cerebellum were not significantly different. However, volume of WM was significantly affected by weight and positively correlated with BMI. Significant positive correlations were found between BMI and volumes of total brain, GM, cortical GM and WM. BMI was negatively correlated with volumes of CSF and third ventricle. CONCLUSION: Brain atrophy was demonstrated in anorexic patients with MP2RAGE-based automated segmentation, which seems to reliably estimate brain volume. KEY POINTS: • Automated brain segmentation based on 3-D MRI seems to reliably estimate brain volume. • This technique detected brain atrophy in patients suffering from anorexia nervosa. • Brain changes in anorexia nervosa can be quantitatively and qualitatively followed-up by MRI.


Assuntos
Anorexia Nervosa/patologia , Encefalopatias/patologia , Encéfalo/patologia , Adolescente , Adulto , Atrofia/patologia , Índice de Massa Corporal , Peso Corporal/fisiologia , Estudos de Casos e Controles , Cerebelo/patologia , Córtex Cerebral/patologia , Ventrículos Cerebrais/patologia , Feminino , Substância Cinzenta/patologia , Humanos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Retrospectivos , Substância Branca/patologia , Adulto Jovem
17.
Virol J ; 13: 83, 2016 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-27216026

RESUMO

BACKGROUND: Herpes simplex virus (HSV) is the most common identified cause of focal encephalitis worldwide. However, postoperative HSV encephalitis (HSVE) is a rare complication of neurosurgical procedures and a significant clinical challenge METHOD: We describe 3 cases of postoperative HSVE and review all published reports. A total of 23 cases were identified. DISCUSSION: Clinical heterogeneity represents a diagnostic challenge in the postoperative setting. Cerebral magnetic resonance imaging showed typical findings in a minority of patients only, whereas HSV-specific polymerase chain reaction on the cerebrospinal fluid proved to be a valuable test. The postoperative viral pathophysiology remains a subject of debate. The rate of adverse outcome is high and early antiviral treatment seems to be a strong predictor of clinical outcome. CONCLUSION: We recommend early empirical treatment for any patient presenting with post-neurosurgical lymphocytic meningo-encephalitis, and prophylactic antiviral treatment for patients with a history of previous HSVE who will undergo a neurosurgical procedure.


Assuntos
Encefalite por Herpes Simples/diagnóstico , Encefalite por Herpes Simples/patologia , Procedimentos Neurocirúrgicos/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/patologia , Líquido Cefalorraquidiano/virologia , Criança , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Prognóstico , Resultado do Tratamento , Adulto Jovem
18.
Neuroradiology ; 58(6): 557-568, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26906112

RESUMO

INTRODUCTION: Syndrome of the trephined (ST) is a post-craniectomy complication. It is characterized by the appearance of new neurological symptoms following the craniectomy, which are relieved after cranioplasty. The purpose of our work was to identify radiological signs and imaging biomarkers of the ST. METHODS: CT images of 32 patients were retrospectively analyzed (ST = 13, controls = 19). While the shapes of craniectomy flap were qualitatively assessed, deviation of the midline structures, relative intracranial cerebrospinal fluid (CSF) volume, and the 3rd ventricle's volume were quantitatively measured. RESULTS: We did not find between-group differences in the mean age or number of post-craniectomy days. ST was diagnosed during the second post-craniectomy month. The occurrence of a sunken skin flap sign was similar in both groups (69.23 % in ST group, 57.89 % in control group). Occurrence of paradoxical herniation and deviation of the midline structures were not significantly different between groups. Mean relative intracranial CSF volume was significantly smaller in ST patients (ST = 5.59 %, controls = 8.12 %, p = 0.01). ST patients, compared to controls, had also significantly smaller mean 3rd ventricle volumes (ST = 1748 mm(3), controls = 2772.97 mm(3), p = 0.03). CONCLUSIONS: ST is an infrequent and delayed post-craniectomy complication. The most common radiological findings (paradoxical herniation, deviation of the midline structures, and sunken skin flap sign) might not be specific for ST. Significantly lower 3rd ventricle, and relative intracranial CSF volumes, suggest that altered biophysical CSF properties underlie ST pathophysiology. Therefore, volume measurements of 3rd ventricle could be useful for identification of patients who have higher probability of developing the ST.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Doenças do Sistema Nervoso/diagnóstico por imagem , Anormalidades da Pele/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Trepanação/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Craniectomia Descompressiva/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças do Sistema Nervoso/etiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Anormalidades da Pele/etiologia , Anormalidades da Pele/patologia , Síndrome
19.
MAGMA ; 29(3): 605-16, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26946508

RESUMO

OBJECTIVES: The aim of this study was to demonstrate that eloquent cortex and epileptic-related hemodynamic changes can be safely and reliably detected using simultaneous electroencephalography (EEG)-functional magnetic resonance imaging (fMRI) recordings at ultra-high field (UHF) for clinical evaluation of patients with epilepsy. MATERIALS AND METHODS: Simultaneous EEG-fMRI was acquired at 7 T using an optimized setup in nine patients with lesional epilepsy. According to the localization of the lesion, mapping of eloquent cortex (language and motor) was also performed in two patients. RESULTS: Despite strong artifacts, efficient correction of intra-MRI EEG could be achieved with optimized artifact removal algorithms, allowing robust identification of interictal epileptiform discharges. Noise-sensitive topography-related analyses and electrical source localization were also performed successfully. Localization of epilepsy-related hemodynamic changes compatible with the lesion were detected in three patients and concordant with findings obtained at 3 T. Local loss of signal in specific regions, essentially due to B 1 inhomogeneities were found to depend on the geometric arrangement of EEG leads over the cap. CONCLUSION: These results demonstrate that presurgical mapping of epileptic networks and eloquent cortex is both safe and feasible at UHF, with the benefits of greater spatial resolution and higher blood-oxygenation-level-dependent sensitivity compared with the more traditional field strength of 3 T.


Assuntos
Mapeamento Encefálico/métodos , Eletroencefalografia/métodos , Epilepsia/diagnóstico por imagem , Epilepsia/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Artefatos , Encéfalo/diagnóstico por imagem , Encéfalo/fisiopatologia , Eletrodos , Feminino , Hemodinâmica , Humanos , Processamento de Imagem Assistida por Computador , Idioma , Masculino , Modelos Estatísticos , Destreza Motora , Oxigênio/sangue , Segurança do Paciente , Reprodutibilidade dos Testes , Adulto Jovem
20.
Semin Musculoskelet Radiol ; 19(2): 137-48, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25764238

RESUMO

Pathologic conditions of the brachial plexus often result in serious and disabling complications. With the increasing availability and use of new and powerful MRI sequences and coils, understanding and assessment of the complex anatomy and pathology of the brachial plexus have been greatly facilitated. These new technical developments have led to an improved assessment of brachial plexus lesions, thereby improving patient care. In this article we describe various MRI techniques for the evaluation of the brachial plexus obtained at 1.5 T and 3 T, and we explain differences and similarities between sequences and protocols performed on MRI equipment from different vendors. The main characteristics of pathologic conditions affecting the brachial plexus are discussed and illustrated, as well as their differential diagnoses, with an emphasis on key imaging findings and relevance for patient management. Pitfalls related to suboptimal technique and image interpretation are also addressed.


Assuntos
Neuropatias do Plexo Braquial/diagnóstico , Plexo Braquial/patologia , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Neoplasias do Sistema Nervoso Periférico/diagnóstico , Plexo Braquial/anatomia & histologia , Plexo Braquial/lesões , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Espectroscopia de Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA