Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Europace ; 25(1): 112-120, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36036679

RESUMO

AIMS: The safety and efficacy of leadless intracardiac-permanent pacemaker (L-PM) have been demonstrated in multiple clinical trials, but data on comparisons with conventional transvenous-permanent pacemaker (T-PM) collected in a consecutive, prospective fashion are limited. The aim of this analysis was to compare the rate and the nature of device-related complications between patients undergoing L-PM vs. T-PM implantation. METHODS AND RESULTS: Prospective, multicentre, observational project enrolling consecutive patients who underwent L-PM or T-PM implantation. The rate and nature of device-related complications were analysed and compared between the two groups. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 2669 (n = 665 L-PM) patients were included and followed for a median of 39 months, L-PM patients were on average older and had more co-morbidities. The risk of device-related complications at 12 months was significantly lower in the L-PM group (0.5% vs. 1.9%, P = 0.009). Propensity matching yielded 442 matched pairs. In the matched cohort, L-PM patients trended toward having a lower risk of overall device-related complications (P = 0.129), had a similar risk of early complications (≤30 days) (P = 1.000), and had a significantly lower risk of late complications (>30 days) (P = 0.031). All complications observed in L-PM group were early. Most (75.0%) of complications observed in T-PM group were lead- or pocket-related. CONCLUSION: In this analysis, the risk of device-related complications associated with L-PM implantation tended to be lower than that of T-PM. Specifically, the risk of early complications was similar in two types of PMs, while the risk of late complications was significantly lower for L-PM than T-PM.


Assuntos
Arritmias Cardíacas , Marca-Passo Artificial , Humanos , Resultado do Tratamento , Desenho de Equipamento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Marca-Passo Artificial/efeitos adversos , Fatores de Tempo
2.
Pacing Clin Electrophysiol ; 45(8): 968-974, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35417055

RESUMO

BACKGROUND: It has been observed that the fourth-generation cryoballoon (CB4) ablation catheter increased the rate of acute real-time recordings of pulmonary vein isolation (PVI) during the ablation for the treatment of atrial fibrillation (AF). The aim of this analysis was to compare the long-term outcome results between patients treated with the CB4 and second-generation cryoballoon (CB2). METHODS: In total, 492 patients suffering from AF, underwent PVI ablation with either the CB2 or CB4 catheter within this examination of the 1STOP real-world Italian project and were included in the analysis. Specifically, 246 consecutive patients treated by CB4 were compared to 246 propensity-matched control patients who underwent PVI using CB2. RESULTS: When comparing the patient cohorts treated with CB2 versus CB4, acute success rate (99.6 ± 4.7% vs. 99.7 ± 3.6%, p = .949) and peri-procedural complications (3.7% vs.1.2%, p = .080) were similar in both groups, respectively. However, procedure time (100 vs.75 min, p < .001) and fluoroscopy duration (21 vs.17 min, p < .001) were all significantly lower in the CB4 treated patient cohort. At the 12-month follow-up, the freedom from AF recurrence after a 90-day blanking period was significant higher in the CB4 as compared with the CB2 group (93.3% vs.81.3%, p < .001). CONCLUSIONS: In summary, usage of the CB4 ablation catheter increased the rate of acute PVI recording capability and resulted in a higher rate of long-term PVI success, as demonstrated by the reduced rate of AF recurrence in comparison to the CB2 cohort at the 12-month follow-up period.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Ablação por Cateter/métodos , Catéteres , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 44(2): 306-317, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33372267

RESUMO

BACKGROUND: Pulmonary veins isolation (PVI) by cryoballoon (CB) ablation is marginally represented in clinical studies in obese patients. The aim of this analysis was to evaluate the safety and efficacy of CB-PVI in a large cohort of overweight and obese patients from the 1STOP project. METHODS: From 2012 to 2018, 2048 patients with atrial fibrillation (AF) (70% male, 59 ± 11 years; 75% paroxysmal AF) underwent index CB-PVI. The patient data were separated into three cohorts for statistical evaluation, including: normal weight (body mass index [BMI] < 25 kg/m2 ), overweight (BMI = 25-30 kg/m2 ), and obese patients (BMI > 30 kg/m2 ). RESULTS: Out of 2048 patients, 693 (34%) patients had a BMI < 25 and were deemed as normal. There were 944 (46%) patients categorized as overweight (BMI = 25-30) and 411 (20%) as obese (BMI > 30). Overweight or obese patients were more often in persistent AF, had more frequently hypertension and diabetes, had higher CHA2 DS2 -VASc score, and had a number of failed antiarrhythmic drug (AAD). Periprocedural complication rates were similar among the three cohorts. The 12-month freedom from AF recurrence was 76.4% in the normal BMI group as compared to 79.2% in the overweight and 73.5% in the obese group (p = .35). However, 48% of overweight patients were on AAD treatment during the follow-up. By multivariate analysis, BMI was not a predictor for AF recurrence following the index CB-PVI. CONCLUSION: CB-PVI in obese patients is a safe procedure. Increased BMI (either moderate or severe) does not seem to be associated with a worse outcome or to a different rate of AAD discontinuation at 12 months.


Assuntos
Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Criocirurgia , Obesidade/complicações , Veias Pulmonares/cirurgia , Idoso , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 31(1): 80-88, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31701569

RESUMO

INTRODUCTION: Four generations of the cryoballoon (CB) catheter were retrospectively evaluated in a real-world examination of patients with atrial fibrillation (AF). METHODS AND RESULTS: Four hundred eighty patients (27% female and 60 ± 10 years) suffering from AF, underwent pulmonary vein (PV) ablation with one-of-four generations of the CB catheter. The total cohort was divided into four groups of patients: 120 with first-generation (CB-1); 120 with second-generation (CB-2); 120 with third-generation (CB-3); and 120 with fourth-generation (CB-4). Equal group sizes were achieved by examining the last 120 patients treated in each cohort, attempting to minimize the effect of a learning curve between the generations of CB catheter. Baseline clinical and patient characteristics were similar between the four cohorts, excepting age and the number of tested antiarrhythmic drugs. Procedure, fluoroscopy, and left atrial dwell times were significantly lower in the CB-4 cohort compared to previous generations of the CB catheters, while the acute procedural success rate was comparable across all catheter groups (>99%). Total acute procedural complications were low (2.5%), and acute complications were comparable within the CB-2, CB-3, and CB-4 groups (0.8% reported in each cohort). The rate of time-to-isolation (TTI) visualization increased with later generations of the CB catheters. CONCLUSIONS: The novel CB-4 achieved significantly faster procedural ablation times in comparison to the previous generations, while still maintaining a low rate of acute complications. Also, the rate of TTI visualization was observed to be higher with the CB-4 catheter. Further long-term evaluation is necessary, including an assessment of AF recurrence and PV reconnection(s).


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Veias Pulmonares/fisiopatologia , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Europace ; 22(12): 1798-1804, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-33006599

RESUMO

AIMS: The aims of this study were to determine the rate and the predictors of early recurrences of atrial fibrillation (ERAF) after cryoballoon (CB) ablation and to evaluate whether ERAF correlate with the long-term outcome. METHODS AND RESULTS: Three thousand, six hundred, and eighty-one consecutive patients (59.9 ± 10.5 years, female 26.5%, and 74.3% paroxysmal AF) were included in the analysis. Atrial fibrillation recurrence, lasting at least 30 s, was collected during and after the 3-month blanking period. Three-hundred and sixteen patients (8.6%) (Group A) had ERAF during the blanking period, and 3365 patients (Group B) had no ERAF. Persistent AF and number of tested anti-arrhythmic drugs ≥2 resulted as significant predictors of ERAF. After a mean follow-up of 16.8 ± 16.4 months, 923/3681 (25%) patients had at least one AF recurrence. The observed freedom from AF recurrence, at 24-month follow-up from procedure, was 25.7% and 64.8% in Groups A and B, respectively (P < 0.001). ERAF, persistent AF, and number of tested anti-arrhythmic drugs ≥2 resulted as significant predictors of AF. In a propensity score matching, the logistic model showed that ERAF 1 month after ablation are the best predictor of long-term AF recurrence (P = 0.042). CONCLUSION: In patients undergoing CB ablation for AF, ERAF are rare and are a strong predictor of AF recurrence in the follow-up, above all when occur >30 days after the ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
6.
Pacing Clin Electrophysiol ; 43(7): 687-697, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32510595

RESUMO

BACKGROUND: Which technique is better for repeat ablation in patients with atrial fibrillation (AF) remains unclear. The aim of the study was to compare long-term efficacy of repeat ablation using the alternative technique for the first redo ablation procedure: (a) cryoballoon (CB) re-ablation after a failed index pulmonary vein isolation (PVI) with radiofrequency (RF) ablation, RF-then-CB group or (b) RF repeat ablation following a failed CB ablation, CB-then-RF group. METHODS: Within the 1STOP Italian Project, consecutive patients undergoing repeat ablation with a different technique from the index procedure were included. RESULTS: We studied 474 patients, 349 in RF-then-CB and 125 in CB-then-RF group. Less women (21% vs 30%; P = .041), more persistent AF (33% vs 22%; P = .015), longer duration of AF (60 vs 31 months; P < .001), and more hypertension (50% vs 36%; P = .007) were observed in the RF-then-CB cohort as compared with the CB-then-RF group. The number of reconnected PVs was 3.7 ± 0.7 and 1.4 + 1.3 in RF-then-CB and CB-then-RF group, respectively (P < .001). During the follow-up, significantly less AF recurrence occurred in the CB-then-RF group (22% vs 8%, HR = 0.46; 95% CI: 0.24-0.92; P = .025). Cohort designation was the only independent predictor of AF recurrence. CONCLUSION: Alternation of energy source for repeat ablation was safe and effective, regardless the energy used first. However, patients initially treated with CB PVI undergoing repeat ablation with RF current had less AF recurrence at long-term follow-up as compared with those originally treated by RF ablation receiving a CB repeat ablation.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Ablação por Radiofrequência/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Reoperação
7.
Heart Lung Circ ; 29(7): 1078-1086, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31594723

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is the most widely adopted strategy for paroxysmal atrial fibrillation (PAF) ablation. Limited evidence on acute results and late outcomes of cryoballoon (CB)-PVI in patients with structural heart disease (SHD) exist. The aim of this analysis was to compare acute procedural results and the 1-year recurrence rate of a single CB-PVI procedure in a PAF population with and without SHD. METHOD: From April 2012 to May 2017, a total of 2,031 patients with AF underwent CB-PVI and were followed prospectively in the framework of the One Shot TO Pulmonary vein isolation (1STOP) ClinicalService project, involving 36 Italian cardiology centres. We identified patients with SHD according to criteria proposed by current ESC guidelines: left ventricular (LV) systolic or diastolic dysfunction, long-standing hypertension with LV hypertrophy, and/or other structural heart disease. Data on procedural outcomes and long-term freedom from AF recurrence were evaluated. RESULTS: Our population consisted of 1,452 patients, of whom 282 (19.4%) were classified as having SHD. Compared to non-SHD patients, the SHD cohort was older (mean ± standard deviation, 62.9 ± 9.0 vs 58.2 ± 11.4 years; p < 0.001), was more frequently male (79.1% vs 69.8%; p < 0.002), had a higher thrombo-embolic risk (CHA2DS2VASc ≥2: 63.4% vs 40.2%; p < 0.001), had a higher body mass index (27.7 ± 3.9 vs 26.4 ± 3.9 kg/m2; p < 0.001), had a larger atrial diameter (43.8 ± 7.0 vs 40.2 ± 5.8 mm; p < 0.001), and had a lower LV ejection fraction (57.2 ± 7.7% vs 60.7 ± 6.0%; p < 0.001). At the time of ablation, 73% of patients were on class Ic or III anti-arrhythmic drugs. Procedure time (106.9 ± 41.5 vs 112.1 ± 46.8 min; p = 0.248), fluoroscopic time (28.7 ± 14.7 vs 28.6 ± 15.2 min; p = 0.819), and complication rate (3.9% vs 4.8%; p = 0.525) were not different between the SHD and non-SHD cohorts. However, the acute success rate (98.9% vs 97.7%; p = 0.016) was higher in patients with SHD. After a follow-up of 13.4 ± 12.8 months, freedom from symptomatic recurrence was 78.0% for SHD and 78.4% for non-SHD (p = 0.895). Recurrence rate was not related to either left atrial size or LVEF. In the SHD cohort, Class Ic or III anti-arrhythmic drugs treatment decreased from 70.7% of patients before ablation to 28.7% of patients after CB-PVI (p = 0.001). CONCLUSIONS: CB-PVI was extensively applied to treat patients with PAF. Unlike previous PVI experiences, the acute success and recurrence rate after a single procedure was not related to the presence of SHD or to the degree of cardiac remodelling. Further studies are required to define whether CB-PVI has a useful role in patients with a significantly reduced ejection fraction as those patients were under-represented in the current population.


Assuntos
Técnicas de Ablação/métodos , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia Paroxística/cirurgia , Função Ventricular Esquerda/fisiologia , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Taquicardia Paroxística/fisiopatologia , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 40(1): 46-56, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27862043

RESUMO

BACKGROUND: Catheter ablation (CA) is recommended for patients with drug refractory symptomatic atrial fibrillation (AF). "One Shot" catheters have been introduced to simplify CA and cryoballoon ablation (CBA) is spreading rapidly. Few real-world data are available on standard clinical practice, mainly from single-center experience. We aimed to evaluate clinical settings, demographics, and acute procedural outcomes in a large cohort of patients treated with CBA. METHODS: A total of 903 patients (73% male, mean age 59 ± 11) underwent pulmonary vein CBA. Correlations between the patient's inclusion time and clinical characteristics, procedure duration, acute success rate, and intraprocedural complications were evaluated. RESULTS: Seventy-seven percent of patients were affected by paroxysmal AF and 23% by persistent AF. Overall, acute success rate was 97.9% and periprocedural complications were observed in 35 (3.9%) patients, 13 (1.4%) of which were classified as major complications. With respect to the patient's inclusion time analysis, an increase in treatment of persistent AF was observed, a significant decrease in CBA times (procedure, ablation, and fluoroscopy: 136.0 ± 46.5 minutes, 28.8 ± 19.6 minutes, and 34.3 ± 15.4 minutes, respectively) was observed, with comparable acute success rate and intraprocedural complications over time. The rate of major complications was extremely low (1.4%); no death, atrioesophageal fistula, stroke, or other major periinterventional or late complications occurred. CONCLUSION: This series represents the largest experience of CBA in the treatment of AF that also describes the adoption curve of this relatively recent technology. CBA showed an excellent safety profile when performed in a large real-world clinical setting, with satisfactory acute success rate and, on average, short procedural times. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov (NCT01007474).


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/estatística & dados numéricos , Crioterapia/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Veias Pulmonares/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Causalidade , Estudos de Coortes , Comorbidade , Estudos de Viabilidade , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Prevalência , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/estatística & dados numéricos , Adulto Jovem
10.
J Cardiovasc Electrophysiol ; 25(5): 500-506, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24494797

RESUMO

INTRODUCTION: The left ventricular (LV) pacing site and the magnitude of the electrical delay within the LV, as expressed by prolonged QRS duration, are major determinants of cardiac resynchronization therapy (CRT) efficacy. We investigated the incremental value of positioning the LV lead in areas of late activation in order to enhance the response to CRT in patients with different degrees of QRS complex lengthening. METHODS AND RESULTS: This analysis was performed on 301 heart failure patients who received a CRT defibrillator. On implantation, the right ventricular (RV)-to-LV interval was measured as the delay between local activations recorded through the RV and LV leads in the final position. After 1 year, 171 (57%) patients displayed reverse LV remodeling, as measured by a ≥15% reduction in the LV end-systolic volume. Both the RV-to-LV interval and its percentage value corrected for the QRS duration were significantly associated with a positive response to CRT. An RV-to-LV interval >80 milliseconds and an RV-to-LV interval/QRS >58% yielded the best prediction of reverse remodeling. Although the response to CRT decreased with shorter QRS duration in the overall population, patients with an RV-to-LV interval >80 milliseconds showed a response rate >65% in all QRS subgroups. CONCLUSION: A longer RV-to-LV interval is associated with reverse LV remodeling after CRT. On implantation attempts could be made to maximize it when selecting the LV lead position, especially in patients with shorter QRS duration, and thus less likely to respond positively to CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Função Ventricular Esquerda , Função Ventricular Direita , Potenciais de Ação , Idoso , Eletrocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Remodelação Ventricular
11.
Pacing Clin Electrophysiol ; 37(12): 1602-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25131984

RESUMO

BACKGROUND: Cardiac perforation of the right ventricle (RV) is a rare but potentially life-threatening complication of both pacemaker (PM) and implantable cardioverter defibrillator (ICD) implant. Appropriate management is still uncertain. We assessed the incidence of subacute (24 hours-1 month) or delayed (>1 month) cardiac perforation by RV lead and the results of percutaneous lead extraction. METHOD: The study population included all patients diagnosed with subacute or delayed RV-lead perforation during the period 2007-2013. The incidence of perforation according to device type and fixation mechanism was calculated. The outcome of the percutaneous approach, consisting of lead extraction by simple traction, was assessed. RESULTS: Cardiac perforation was diagnosed in 14 (eight females, mean age 71 [range 47-83] years) patients out of 3,815 who received an RV-lead implant (0.4%). The overall incidence of RV-lead perforation was similar between ICD (0.3%) and PM (0.4%) implants (P = 1.0) and between active (0.5%) and passive (0.3%) fixation leads (P = 0.3). All perforating leads were originally placed at the RV apex. Five patients were asymptomatic, but all presented altered lead electrical parameters. Surgical removal of the lead was performed in one patient while in the remaining the leads were successfully extracted by direct manual traction in the absence of any complications. In all patients, new active fixation leads were positioned in the RV septum and the follow-up (42 ± 27 months) was uneventful. CONCLUSIONS: RV perforation is a rare complication of both PM and ICD implants, regardless of the lead fixation mechanism. In most patients, percutaneous lead extraction is a safe and effective management approach.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Traumatismos Cardíacos/epidemiologia , Traumatismos Cardíacos/terapia , Ventrículos do Coração/lesões , Marca-Passo Artificial/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Feminino , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/prevenção & controle , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
12.
J Interv Card Electrophysiol ; 67(3): 609-616, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37697222

RESUMO

BACKGROUND: The aims of this analysis were: to evaluate the impact of timing of ablation on the rate of atrial arrhythmias recurrence, verify if the timing of ablation impact differently in patients with paroxysmal and persistent AF. METHODS: Three thousand two hundred and five patients (60.5 ± 10 years, female 28.4%%, 78.8%% paroxysmal AF) were included in the analysis. All patients underwent only cryoballoon (CB) pulmonary vein (PV) isolation during the index procedure. RESULTS: The mean procedure time was 102.8 ± 50 min, with a mean fluoroscopy time of 26.3 ± 49 min. Acute PV isolation was achieved in 11760/11793 (99.7%) PVs. A total of 91 (2.8%) patients experienced a procedure-related complication. During the observation period 913/3205 (28.5%) patients had at least one atrial arrhythmias episode: 28% of patients with paroxysmal AF vs 33% of patients with persistent AF. In multivariate analysis, persistent AF together with time from symptomatic AF diagnosis to ablation, female sex, and ablation time showed to be significant predictors for AF recurrence. In particular, months from first symptomatic AF episode > 18 months was a significant predictor of AF recurrence (HR = 1.23, 95% CI = 1.03-1.46, p = 0.020). In patients with paroxysmal AF, the multivariate analysis confirmed that months from first symptomatic AF episode > 18 month was an independent predictor of AF recurrence together with age > 62 years and female sex. In patients with persistent AF, the time from persistent AF showed to be significant predictor for AF recurrence. CONCLUSIONS: In this multicenter analysis, time from first symptomatic AF episode > 18 months was a significant predictor of AF recurrence after CB PV isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Resultado do Tratamento , Veias Pulmonares/cirurgia , Criocirurgia/métodos , Fatores de Tempo , Ablação por Cateter/métodos , Recidiva
13.
J Interv Card Electrophysiol ; 67(1): 61-69, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37178189

RESUMO

BACKGROUND: Pulmonary vein isolation by cryoablation (PVI-C) is a standard therapy for the treatment of patients with symptomatic atrial fibrillation (AF). AF symptoms are highly subjective; however, they are important outcomes for the patient. The aim is to describe the use and impact of a web-based App to collect AF-related symptoms in a population of patients who underwent PVI-C in seven Italian centers. METHODS: A patient App to collect AF-related symptoms and general health status was proposed to all patients who underwent an index PVI-C. Patients were divided into two groups according to the utilization of the App or the non-usage. RESULTS: Out of 865 patients, 353 (41%) subjects composed the App group, and 512 (59%) composed the No-App group. Baseline characteristics were comparable between the two cohorts except for age, sex, type of AF, and body mass index. During a mean follow-up of 7.9±13.8 months, AF recurrence was found in 57/865 (7%) subjects with an annual rate of 7.36% (95% CI:5.67-9.55%) in the No-App versus 10.99% (95% CI:9.67-12.48%) in the App group, p=0.007. In total, 14,458 diaries were sent by the 353 subjects in the App group and 77.1% reported a good health status and no symptoms. In only 518 diaries (3.6%), the patients reported a bad health status, and bad health status was an independent parameter of AF recurrence during follow-up. CONCLUSIONS: The use of a web App to record AF-related symptoms was feasible and effective. Additionally, a bad health status reporting in the App was associated with AF recurrence during follow-up.


Assuntos
Fibrilação Atrial , COVID-19 , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Resultado do Tratamento , Criocirurgia/efeitos adversos , Veias Pulmonares/cirurgia , Recidiva , Ablação por Cateter/efeitos adversos
14.
J Cardiovasc Electrophysiol ; 24(2): 173-81, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23130781

RESUMO

INTRODUCTION: The characteristics and outcomes of patients who undergo cardiac resynchronization therapy (CRT) device implantation in current clinical practice may differ from those of reference trial populations. Study objectives were to assess 2-year outcomes in a population implanted with a CRT plus defibrillator device in accordance with the standard of care and to evaluate any independent association between clinical variables and outcome. METHODS AND RESULTS: A total of 406 patients enrolled at 35 centers in Italy were followed up prospectively for 2 years. All patient management decisions were left to the treating physician's discretion, in accordance with clinical practice. ACTION-HF patients had a better baseline clinical status than patients enrolled in the COMPANION study: shorter HF history (1 vs 3.5 years, P < 0.01), less advanced NYHA functional class (III-IV: 73% vs 100%, P < 0.01), higher LVEF (26% vs 21%, P < 0.01), higher SBP (122 vs 112 mmHg, P < 0.01), and less diabetes (27% vs 41%, P < 0.01). This status was reflected in lower mortality (11.5% vs 26%) and a lower incidence of appropriate ICD shocks (12.1% vs 19.3%). AF history was an independent predictor of the combination of all-cause mortality and cardiac-cause hospitalization (HR: 3.31; P < 0.001). Recurrent or new atrial arrhythmias were independently associated with the development of ventricular arrhythmias (HR: 3.4; P < 0.001). CONCLUSIONS: This population appears clinically less compromised and had a lower incidence of adverse clinical outcomes than those of reference trials. However, we recorded a substantial burden of atrial arrhythmias, which was independently associated with a higher incidence of ventricular arrhythmias.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Terapia de Ressincronização Cardíaca/mortalidade , Hospitalização/estatística & dados numéricos , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/prevenção & controle , Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
15.
Clin Cardiol ; 46(2): 142-150, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36448243

RESUMO

BACKGROUND: Atrial fibrillation (AF) is an uncommon arrhythmia in young adults without structural heart disease, and cryoballoon pulmonary vein isolation (CB-PVI) is an important therapeutic strategy for rhythm control in patients with drug-refractory AF. The aim of this analysis was to evaluate efficacy and safety of CB-PVI in a large cohort of young patients in comparison with middle-aged adults in a real-world setting. METHODS: From 2012 to 2020, a total of 3033 patients with AF underwent CB-PVI and were followed prospectively in the framework of the 1STOP Clinical Service project, involving 34 Italian centers. Out of 3033 total 1STOP project subjects, a subgroup of 1318 patients were defined which included a YOUNG group (age ≤ 45 years; n = 368) and a MIDDLE-AGED group (age 60-65 years; n = 950). RESULTS: The acute success rate of PVI did not differ between the two cohorts (99.9 ± 1.3% vs. 99.8 ± 3.2%, p = 0.415). There was no difference in procedural characteristics, and periprocedural complication rates were similar among the two cohort (1.9% vs. 2.3%, p = 0.646). The 12-month freedom from AF recurrence was 88.9% (95% confidence interval [CI]: 84.7-92.0) in the YOUNG cohort and 85.6% (95% CI: 82.9-88.0) in the MIDDLE-AGED group. At 36-month follow-up, freedom from AF recurrence was 72.4% (65.5%-78.2%) and 71.8% (67.7%-75.6%), respectively with no significant difference among groups (p = 0.550). CONCLUSION: CB-PVI had similar efficacy and safety in YOUNG and MIDDLE-AGED patients. Younger age did not affect acute procedural results, complication rate, or AF recurrence after a single procedure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Cardiopatias , Veias Pulmonares , Pessoa de Meia-Idade , Adulto Jovem , Humanos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Recidiva , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
16.
J Interv Card Electrophysiol ; 66(5): 1193-1200, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36417124

RESUMO

BACKGROUND: Pulmonary vein isolation by cryoablation (PVI-C) is a standard therapy for the treatment of atrial fibrillation (AF). The CHA2DS2-VASc score is a well-established predictor of AF-related stroke. Whether the CHA2DS2-VASc score can also be useful in predicting the long-term clinical outcomes following PVI-C is still unsettled. The aim of this analysis was to evaluate the role of the CHA2DS2-VASc score in predicting AF recurrence after PVI-C. METHODS: Patients with symptomatic AF underwent an index PVI-C. Data were collected prospectively in the framework of the 1STOP ClinicalService project. Patients were categorized into two groups: low risk (LR) and high risk (HR) based on CHA2DS2-VASc score (0-1 and ≥ 2, respectively). RESULTS: Out of 3313 patients, 1910 (57.6%) had a CHA2DS2-VASc score between 0 and 1, while 1403 (42.3%) had CHA2DS2-VASc > = 2. Patient characteristics were significantly different between the two cohorts, including age, sex, BMI, paroxysmal AF, history of stroke, diabetes, and ischemic cardiomyopathy. On the contrary, procedural times and acute complications were comparable. The 36-month freedom from AF after a single procedure was 72.5% (95% CI: 69.8-75.0) in the LR group and 65.9% (95% CI: 62.3-69.2) in the HR score group (HR: 1.26, 95% CI: 1.08-1.47, p = 0.001). After multivariate analysis, higher CHA2DS2-VASc score was still a significant predictor of the risk of AF recurrence (HR: 1.33; 1.10-1.60, p = 0.003). CONCLUSIONS: PVI-C is highly effective in the treatment of AF over the long term. A CHA2DS2-VASc score ≥ 2 is an independent predictor of AF recurrence during the follow-up and should be considered during the clinical management after the index procedure.


Assuntos
Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Veias Pulmonares/cirurgia , Fatores de Risco , Criocirurgia/métodos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Medição de Risco/métodos , Recidiva
17.
J Interv Card Electrophysiol ; 66(7): 1749-1757, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36869990

RESUMO

BACKGROUND: A novel ablation catheter has been released to map and ablate the cavo-tricuspid isthmus (CTI) in patients with atrial flutter (AFL), improving ablation efficiency. METHODS: We evaluated the acute and long-term outcome of CTI ablation aiming at bidirectional conduction block (BDB) in a prospective, multicenter cohort study enrolling 500 patients indicated for typical AFL ablation. Patients were grouped on the basis of the AFL ablation method (linear anatomical approach, Conv group n = 425, or maximum voltage guided, MVG group, n = 75) and ablation catheter (mini-electrodes technology, MiFi group, n = 254, or a standard 8-mm ablation catheter, BLZ group, n = 246). RESULTS: Complete BDB according to both validation criteria (sequential detailed activation mapping or mapping only the ablation site) was achieved in 443 patients (88.6%). The number of RF applications needed to achieve BDB was lower in the MiFi MVG group vs both the MiFi Conv group and the BLZ Conv group (3.2 ± 2 vs 5.2 ± 4 vs 9.3 ± 5, p < 0.0001 for all comparisons). Fluoroscopy time was similar among groups, whereas we observed a reduction in the procedure duration from the BLZ Conv group (61.9 ± 26min) to the MiFi MVG group (50.6 ± 17min, p = 0.048). During a mean follow-up of 548 ± 304 days, 32 (6.2%) patients suffered an AFL recurrence. No differences were found according to BDB achieved by both validation criteria. CONCLUSIONS: Ablation was highly effective in achieving acute CTI BDB and long-term arrhythmia freedom irrespective of the ablation strategy or the validation criteria for CTI chosen by the operator. The use of an ablation catheter equipped with mini-electrodes technology seems to improve ablation efficiency. CLINICAL TRIAL REGISTRATION: Atrial Flutter Ablation in a Real World Population. (LEONARDO). CLINICALTRIALS: gov Identifier: NCT02591875.


Assuntos
Flutter Atrial , Ablação por Cateter , Humanos , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Estudos de Coortes , Estudos Multicêntricos como Assunto , Estudos Prospectivos , Resultado do Tratamento , Estudos Clínicos como Assunto
18.
J Cardiovasc Dev Dis ; 9(5)2022 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-35621837

RESUMO

The aim of this research was to evaluate if patients with chronic kidney disease (CKD) and mild or mild to moderate depression of renal function have an increased risk of atrial fibrillation (AF) recurrences after cryoballoon (CB) ablation. We performed a retrospective analysis of AF patients undergoing pulmonary vein isolation (PVI) by CB. The cohort was divided according to the KDIGO CKD-EPI classification into a (1) normal, (2) mildly decreased, or (3) mild to moderate reduction in estimated glomerular filtration rate (eGFR). Freedom from AF recurrences was the primary endpoint. A total of 1971 patients were included (60 ± 10 years, 29.0% females, 73.6% paroxysmal AF) in the study. Acute success and complication rates were 99.2% and 3.7%, respectively, with no significant differences among the three groups. After a follow-up of 24 months, AF recurrences were higher in the mildly and mild to moderate CKD groups compared to the normal kidney function group (23.4% vs. 28.3% vs. 33.5%, p < 0.05). Mild to moderate CKD was an independent predictor of AF recurrences after the blanking period (hazard ratio:1.38, 95% CI 1.02−1.86, p = 0.037). In conclusion, a multicenter analysis of AF patients treated with cryoablation revealed mild to moderate reductions in renal functions were associated with a higher risk of AF recurrences. Conversely, the procedural success and complication rates were similar in patients with normal, mildly reduced, or mild to moderate reduction in eGFR.

19.
Cardiol Res Pract ; 2021: 9996047, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34992884

RESUMO

BACKGROUND: The real-world efficacy and safety of atrial fibrillation (AF) ablation in particularly young and elderly patients are still under debate. The aim of the analysis was to investigate the effect of age on the efficacy and safety of cryoballoon ablation (CBA). METHODS: 2,534 patients underwent pulmonary vein isolation (PVI) by way of CBA for paroxysmal or persistent drug-resistant and symptomatic AF. The population was divided into age quartiles for evaluation, including (1) <53 years, (2) ≥53 and <61 years, (3) ≥61 and <67 years, and (4) ≥67 years. Furthermore, outcomes were analyzed in patients <41 years, ≥41 and ≤74, and >74 years old. Procedural data and complications were collected, and atrial fibrillation recurrences were evaluated during follow-up. RESULTS: Procedural-related complications (4.1%) were similar in the four subgroups according to age. At the 12-month follow-up, freedom from AF recurrence was 79.2%, 77.4%, 76.8%, and 75.2% (p=0.21), respectively (with increasing age). At 24-month follow-up, similar incidences of AF recurrence were observed in the four subgroups. When the sample was arbitrarily divided into the three age groups, a higher rate of recurrence was observed in older patients with regard to long-term follow-up (freedom from AF recurrence was 71.8% and 40.9%, respectively, at 12 and 24-month follow-up). In the univariate and multivariate analysis, age did not result in a significant predictor of AF recurrence during follow-up; however, a trend toward higher AF recurrences rates in patients ≥67 years was observed. CONCLUSION: The data demonstrated a high degree of safety during CBA across all patient ages. Procedural performance and complications were similar between different ages; AF recurrences seem to be more frequent in patients over 74 years.

20.
J Cardiovasc Med (Hagerstown) ; 22(8): 618-623, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34009837

RESUMO

AIMS: Pulmonary vein isolation (PVI) using cryoballoon ablation (CBA) is mainly reserved for patients with drug-refractory or drug-intolerant symptomatic atrial fibrillation. We evaluated a large cohort of patients treated in a real-world setting and examined the safety and efficacy profile of CBA when applied as a first-line treatment for atrial fibrillation. METHODS: In total, 249 patients (23% women; 56 ±â€Š13 years; mean left atrial diameter 41 ±â€Š7 mm; 73.5% paroxysmal atrial fibrillation; and 26.5% persistent atrial fibrillation) underwent an index PVI by CBA. Data were collected prospectively in the framework of the 1STOP ClinicalService project, involving 26 Italian cardiology centers. RESULTS: Median procedure and fluoroscopy times were 90.0 and 21.0 min, respectively. Acute procedural success was 99.8%. Acute/periprocedural complications were observed in seven patients (2.8%), including: four transient diaphragmatic paralyses, one pericardial effusion (not requiring any intervention), one transient ischemic attack, and one minor vascular complication. The Kaplan--Meier freedom from atrial fibrillation recurrence was 86.3% at 12 months and 76% at 24 months. Seventeen patients (6.8%) had a repeat catheter ablation procedure during the follow-up period. At last follow-up, 10% of patients were on an anticoagulation therapy, whereas 6.8% were on an antiarrhythmic drug. CONCLUSION: In our multicenter real-world experience, PVI by CBA in a first-line atrial fibrillation patient population was well tolerated, effective, and promising. CBA with a PVI strategy can be used to treat patients with paroxysmal and persistent atrial fibrillation with good acute procedural success, short procedure times, and acceptable safety. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov (NCT01007474).


Assuntos
Fibrilação Atrial , Criocirurgia , Complicações Pós-Operatórias , Prevenção Secundária/estatística & dados numéricos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Segurança do Paciente , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Saúde Radiológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA