Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 129(18): 183601, 2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36374702

RESUMO

We experimentally study entangled two-photon absorption in rhodamine 6G as a function of the spatial properties of a high flux of broadband entangled photon pairs. We first demonstrate a key signature dependence of the entangled two-photon absorption rate on the type of entangled pair flux attenuation: linear, when the laser pump power is attenuated, and quadratic, when the pair flux itself experiences linear loss. We then perform a fluorescence-based Z-scan measurement to study the influence of beam waist size on the entangled two-photon absorption process and compare this to classical single- and two-photon absorption processes. We demonstrate that the entangled two-photon absorption shares a beam waist dependence similar to that of classical two-photon absorption. This result presents an additional argument for the wide range of contrasting values of quoted entangled two-photon absorption cross sections of dyes in literature.

2.
J Biol Regul Homeost Agents ; 35(3 Suppl. 1): 127-137, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34289672

RESUMO

The aesthetic goals of implant dentistry should be similar to those of conventional prostheses. In implant-prosthetic rehabilitations of the anterior sectors, the quantity and quality of hard and soft tissue play a fundamental role in achieving the desired aesthetics and in integrating the restoration in a complete and harmonious way into the existing anterior dentition. Post-extraction implantology is a treatment option for implant therapy after the extraction of a single tooth in the anterior jaw. This article presents some key factors to analyze and follow in order to achieve a predictable and acceptable aesthetic result. The creation of a predictable peri-implant aesthetics requires adequate preservation of the bone and soft tissues around the teeth that will be extracted and a correct positioning of the 3D implant. Furthermore, aesthetic success requires the creation of a correct transmucosal path, during the provisional prosthetic phases, which must be replicated and maintained with the definitive crowns.


Assuntos
Carga Imediata em Implante Dentário , Coroas , Estética , Estética Dentária , Extração Dentária , Resultado do Tratamento
3.
Phys Rev Lett ; 114(9): 095004, 2015 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-25793822

RESUMO

Energy loss in the transport of a beam of relativistic electrons in warm dense aluminum is measured in the regime of ultrahigh electron beam current density over 2×10^{11} A/cm^{2} (time averaged). The samples are heated by shock compression. Comparing to undriven cold solid targets, the roles of the different initial resistivity and of the transient resistivity (upon target heating during electron transport) are directly observable in the experimental data, and are reproduced by a comprehensive set of simulations describing the hydrodynamics of the shock compression and electron beam generation and transport. We measured a 19% increase in electron resistive energy loss in warm dense compared to cold solid samples of identical areal mass.

4.
Sci Rep ; 13(1): 20681, 2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38001120

RESUMO

Shock Ignition is a two-step scheme to reach Inertial Confinement Fusion, where the precompressed fuel capsule is ignited by a strong shock driven by a laser pulse at an intensity in the order of [Formula: see text] W/cm[Formula: see text]. In this report we describe the results of an experiment carried out at PALS laser facility designed to investigate the origin of hot electrons in laser-plasma interaction at intensities and plasma temperatures expected for Shock Ignition. A detailed time- and spectrally-resolved characterization of Stimulated Raman Scattering and Two Plasmon Decay instabilities, as well as of the generated hot electrons, suggest that Stimulated Raman Scattering is the dominant source of hot electrons via the damping of daughter plasma waves. The temperature dependence of laser plasma instabilities was also investigated, enabled by the use of different ablator materials, suggesting that Two Plasmon Decay is damped at earlier times for higher plasma temperatures, accompanied by an earlier ignition of SRS. The identification of the predominant hot electron source and the effect of plasma temperature on laser plasma interaction, here investigated, are extremely useful for developing the mitigation strategies for reducing the impact of hot electrons on the fuel ignition.

5.
Phys Rev Lett ; 109(25): 255002, 2012 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-23368474

RESUMO

We present experimental and numerical results on intense-laser-pulse-produced fast electron beams transport through aluminum samples, either solid or compressed and heated by laser-induced planar shock propagation. Thanks to absolute K(α) yield measurements and its very good agreement with results from numerical simulations, we quantify the collisional and resistive fast electron stopping powers: for electron current densities of ≈ 8 × 10(10) A/cm(2) they reach 1.5 keV/µm and 0.8 keV/µm, respectively. For higher current densities up to 10(12)A/cm(2), numerical simulations show resistive and collisional energy losses at comparable levels. Analytical estimations predict the resistive stopping power will be kept on the level of 1 keV/µm for electron current densities of 10(14)A/cm(2), representative of the full-scale conditions in the fast ignition of inertially confined fusion targets.

6.
Nat Commun ; 13(1): 2893, 2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35610200

RESUMO

Ion stopping in warm dense matter is a process of fundamental importance for the understanding of the properties of dense plasmas, the realization and the interpretation of experiments involving ion-beam-heated warm dense matter samples, and for inertial confinement fusion research. The theoretical description of the ion stopping power in warm dense matter is difficult notably due to electron coupling and degeneracy, and measurements are still largely missing. In particular, the low-velocity stopping range, that features the largest modelling uncertainties, remains virtually unexplored. Here, we report proton energy-loss measurements in warm dense plasma at unprecedented low projectile velocities. Our energy-loss data, combined with a precise target characterization based on plasma-emission measurements using two independent spectroscopy diagnostics, demonstrate a significant deviation of the stopping power from classical models in this regime. In particular, we show that our results are in closest agreement with recent first-principles simulations based on time-dependent density functional theory.

7.
Phys Rev Lett ; 107(6): 065004, 2011 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-21902333

RESUMO

Fast electrons produced by a 10 ps, 160 J laser pulse through laser-compressed plastic cylinders are studied experimentally and numerically in the context of fast ignition. K(α)-emission images reveal a collimated or scattered electron beam depending on the initial density and the compression timing. A numerical transport model shows that implosion-driven electrical resistivity gradients induce strong magnetic fields able to guide the electrons. The good agreement with measured beam sizes provides the first experimental evidence for fast-electron magnetic collimation in laser-compressed matter.

8.
J Endocrinol Invest ; 34(9): e287-90, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21666414

RESUMO

UNLABELLED: Gestational diabetes mellitus (GDM) predisposes women to future development of Type 2 diabetes mellitus (DM2) and the two conditions share similar metabolic alterations. Recent observations suggest that a defective glucose stimulated insulin secretion by glucagon-like peptide-1 (GLP- 1) plays a role in the pathogenesis of DM2. Whether such a defect is impaired in GDM remains to be ascertained. AIM: We have determined GLP-1 secretion in response to oral glucose tolerance test (OGTT) in GDM and normal glucose tolerance (NGT) during and after pregnancy. MATERIALS AND METHODS: 100-g-3h OGTT was performed in 12 GDM and 16 NGT women at 27.3 ± 4.1 weeks of gestation, for determination of plasma GLP-1, glucose, insulin, and C-peptide. Insulin sensitivity (ISI) and insulin secretion (first and second phase); as well as ISI-secretion index (ISSI) were also derived. RESULTS: NGT and GDM women were comparable for age pre-pregnancy body mass index (BMI) and weight gain. GDM had higher glucose area under the curve (AUC): 27,575.5 ± 3448 vs 20,685.88 ± 2715 mg/dl min (p<0.01), but lower first-phase insulin secretion (993.12±367 vs 1376.61 ± 423, p<0.05) and ISSI compared to controls (3873.23 ± 1185 vs 6232.13 ± 1734, p<0.001). When we examined GLP-1 mean levels in relation to mean glycemic values, GLP-1 secretion was inappropriately low with respect to mean glycemic values in GDM compared to NGT. At follow-up, AUCGLP-1 was significantly lower in post-partum GDM compared to post-partum NGT women (2542 ± 273 vs 10,092 ± 7367 pmol·l-1·min-1, p<0.05, respectively). CONCLUSIONS: Our study suggests that GLP-1 secretion in GDM women is inadequate for the prevailing glycemic levels both in pregnancy and post partum. Moreover, we cannot exclude that other important aspects of the incretin effect may be involved in GDM development.


Assuntos
Diabetes Gestacional/sangue , Peptídeo 1 Semelhante ao Glucagon/sangue , Peptídeo 1 Semelhante ao Glucagon/metabolismo , Complicações na Gravidez/sangue , Gravidez/sangue , Adulto , Área Sob a Curva , Glicemia/metabolismo , Peptídeo C/metabolismo , Feminino , Teste de Tolerância a Glucose , Humanos , Insulina/sangue , Insulina/metabolismo , Secreção de Insulina , Pessoa de Meia-Idade
9.
Sci Rep ; 11(1): 6881, 2021 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-33767262

RESUMO

We report on the development of a highly directional, narrow energy band, short time duration proton beam operating at high repetition rate. The protons are generated with an ultrashort-pulse laser interacting with a solid target and converted to a pencil-like narrow-band beam using a compact magnet-based energy selector. We experimentally demonstrate the production of a proton beam with an energy of 500 keV and energy spread well below 10[Formula: see text], and a pulse duration of 260 ps. The energy loss of this beam is measured in a 2 [Formula: see text]m thick solid Mylar target and found to be in good agreement with the theoretical predictions. The short time duration of the proton pulse makes it particularly well suited for applications involving the probing of highly transient plasma states produced in laser-matter interaction experiments. This proton source is particularly relevant for measurements of the proton stopping power in high energy density plasmas and warm dense matter.

10.
Sci Adv ; 7(3)2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33523900

RESUMO

Among the existing elemental characterization techniques, particle-induced x-ray emission (PIXE) and energy-dispersive x-ray (EDX) spectroscopy are two of the most widely used in different scientific and technological fields. Here, we present the first quantitative laser-driven PIXE and laser-driven EDX experimental investigation performed at the Centro de Láseres Pulsados in Salamanca. Thanks to their potential for compactness and portability, laser-driven particle sources are very appealing for materials science applications, especially for materials analysis techniques. We demonstrate the possibility to exploit the x-ray signal produced by the co-irradiation with both electrons and protons to identify the elements in the sample. We show that, using the proton beam only, we can successfully obtain quantitative information about the sample structure through laser-driven PIXE analysis. These results pave the way toward the development of a compact and multifunctional apparatus for the elemental analysis of materials based on a laser-driven particle source.

11.
Sci Rep ; 10(1): 8100, 2020 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-32393805

RESUMO

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

12.
Science ; 211(4486): 1062-4, 1981 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-7466378

RESUMO

Throughout development, Mongolian gerbils engage in conspicuous naso-oral investigations of their social partners' mouth areas. The behavioral contribution of saliva-related stimuli in regulating oral-directed responses was studied during several important phases of the gerbil's social life. Weanlings were preferentially attracted to their mother's saliva, subadults at puberty preferred saliva of littermates to that of nonlittermates, and sexually experienced males preferred the saliva of estrous females to that of nonestrous females. The use of saliva as a discriminative cue during various developmental periods suggests that oral chemostimuli have a perennial role in regulating social interchanges.


Assuntos
Comportamento Animal/fisiologia , Gerbillinae/fisiologia , Saliva/fisiologia , Comportamento Social , Animais , Animais Lactentes/fisiologia , Feminino , Masculino , Comportamento Materno
13.
Sci Rep ; 9(1): 18805, 2019 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-31827132

RESUMO

X-ray phase contrast imaging (XPCI) is more sensitive to density variations than X-ray absorption radiography, which is a crucial advantage when imaging weakly-absorbing, low-Z materials, or steep density gradients in matter under extreme conditions. Here, we describe the application of a polychromatic X-ray laser-plasma source (duration ~0.5 ps, photon energy >1 keV) to the study of a laser-driven shock travelling in plastic material. The XPCI technique allows for a clear identification of the shock front as well as of small-scale features present during the interaction. Quantitative analysis of the compressed object is achieved using a density map reconstructed from the experimental data.

14.
Rev Sci Instrum ; 90(6): 063704, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31255027

RESUMO

A prototype of a highly adjustable Kirkpatrick-Baez (KB) microscope has been designed, built, and tested in a number of laser driven x-ray experiments using the high power (200 TW) VEGA-2 laser system of the Spanish Centre for Pulsed Lasers (CLPU). The presented KB version consists of two, perpendicularly mounted, 500 µm thick silicon wafers, coated with a layer of platinum, a few tens of nanometers thick. Unlike the usual millimeter thick glass substrate, this design allows for a larger bending flexibility and large adjustment range. According to simulations, this KB microscope offers broadband multikiloelectron volt reflection spectra (1 eV-20 keV), allowing more spectral tunability than conventional Bragg crystals. In addition to be vacuum compatible, this prototype is characterized by a relatively small size (21 cm × 31 cm × 27 cm) and permits remote control and modification both of the radii of curvature (down to 10 m) and of the grazing incidence angle (up to 60 mrad). A few examples of focusing performance tests and experimental results are discussed.

16.
Diabetes Res Clin Pract ; 77(3): 465-70, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17350135

RESUMO

To assess whether HbA1c and plasma glucose predicts abnormal fetal growth, 758 pregnant women attending 5 Diabetic Centers were screened for gestational diabetes mellitus (GDM). On glucose challenge (GCT) at 24-27 weeks of gestation (g.w.), negative cases formed the normal control group (N1). Positive cases took an oral glucose tolerance test (OGTT): those found negative were classed as false positives screening test (N2); if they had an OGTT result at least as high as their normal glucose levels, they were classed as having one abnormal glucose value (OAV) at OGTT; two values as GDM. HbA1c was assayed on the day of GCT. We considered fetal macrosomia, large for gestational age (LGA), ponderal index and mean growth percentile. Mean age, pre-pregnancy BMI, fasting plasma glucose (FPG) and HbA1c were progressively higher from N1 to GDM patients. The newborn of N2 mothers were heavier than those with N1 or GDM. The mean growth percentile was significantly higher in N2 than in N1. More LGA babies were born to OAV than to N1 or N2 women. Macrosomia and ponderal index did not differ significantly in the four groups. At logistic regression only plasma glucose at GCT could predict LGA babies and a ponderal index above 2.85. At risk analysis, GDM and OAV significantly predicted LGA babies, and GDM a ponderal index >2.85. In conclusion, FPG at GCT could predict fetal overgrowth and plasma glucose >85mg/dl doubles the risk of LGA infants. HbA1c at 24-27g.w. does not predict fetal overgrowth. Mild alterations in glucose tolerance correlate with fetal overgrowth and needs monitoring and treatment.


Assuntos
Peso ao Nascer , Glicemia/análise , Desenvolvimento Fetal , Intolerância à Glucose , Hemoglobinas Glicadas/análise , Valor Preditivo dos Testes , Adulto , Estudos Transversais , Diabetes Mellitus , Feminino , Idade Gestacional , Teste de Tolerância a Glucose , Humanos , Recém-Nascido , Mães , Gravidez
17.
J Endocrinol Invest ; 30(10): 873-9, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18075292

RESUMO

Physiological changes of pregnancy include insulin resistance and activation of the innate immunity with an inflammatory response. The working hypothesis is that the sub-clinical inflammation associated with excessive adiposity may favor the development of gestational diabetes (GDM) and Type 2 diabetes and other metabolic abnormalities related to cardiovascular disease later in life. In this paper we review the complex interrelationship among inflammatory markers, metabolic syndrome, and endothelium dysfunction in women with GDM and discuss if women with previous GDM (pGDM) could be considered at risk for cardiovascular diseases. MEDLINE was searched for articles relating GDM and the adipokines (tumor necrosis factor-alpha and adiponectin) as well as the acute-phase inflammatory biomarker C-reactive protein that contribute to the development of diabetic pregnancy and vascular complications. However, to date, in pGDM women no prospective study is available, to corroborate the hypothesis that inflammatory pattern could be taken as predictor of cardiovascular disease later in life. Therefore, our paper should provide arguments to perform follow-up programs to prevent cardiovascular events in women with pGDM. Control of body weight, regular physical exercise are indeed powerful intervention tools able at improving insulin sensitivity and reduce sub-clinical inflammation, both involved in the pathogenesis of cardiovascular disease.


Assuntos
Diabetes Gestacional/imunologia , Diabetes Gestacional/metabolismo , Angiopatias Diabéticas/imunologia , Angiopatias Diabéticas/metabolismo , Inflamação/imunologia , Inflamação/metabolismo , Fatores Etários , Envelhecimento/imunologia , Envelhecimento/metabolismo , Doenças Cardiovasculares/imunologia , Doenças Cardiovasculares/metabolismo , Feminino , Humanos , Gravidez
18.
Oper Dent ; 42(4): 436-444, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28402732

RESUMO

The aim of this study was to evaluate the effect of different production methods of resin and ceramic inlays on marginal and internal adaptation, adjustment time, and proximal contacts. Forty premolars were selected, embedded (their roots), and prepared to receive inlays that were made as follows (n=10): LaRe-digital impression with a Lava C.O.S. scanner, followed by milling of Lava Ultimate block (composite resin) in a milling center; CeRe-digital impression with a Cerec 3D Bluecam scanner, followed by milling of Lava Ultimate block in Cerec; CeDis-digital impression with a Cerec 3D Bluecam scanner, followed by milling of IPS e.max CAD block (lithium disilicate) in Cerec; and PresDis-impression with polyvinyl siloxane, inlay made using the lost wax technique and IPS e.max Press pressed ceramic (lithium disilicate). Marginal and internal adaptations were measured using the replica technique. The inlay adjustments were performed using diamond burs in a contra-angle hand piece, and the time for adjustment was recorded using a timer, in seconds. The tightness of the proximal contact was measured using standardized metal blades. The statistical analyses for marginal fit data showed that at the cervical edge, CeDis (177.8 µm) had greater misfit than CeRe (116.7 µm), while all the groups had similar adaptation at the occlusal edge. The groups had similar internal fit at the pulpal wall, while LaRe (104.7 µm) > CeDis (66.7 µm) = CeRe (76.7 µm) at the axial wall. The groups restored with lithium disilicate ceramic took more time for adjustment when compared to the resin restorative material. The lowest proximal contact, in micrometers, was seen in the CeRe group (8.8 µm).


Assuntos
Resinas Compostas/química , Técnica de Moldagem Odontológica , Adaptação Marginal Dentária , Porcelana Dentária/química , Restaurações Intracoronárias , Dente Pré-Molar , Preparo da Cavidade Dentária , Materiais Dentários/química , Humanos , Técnicas In Vitro , Teste de Materiais , Fatores de Tempo
19.
Appl Radiat Isot ; 106: 145-50, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26249744

RESUMO

The reliability of Fricke gel dosimeters in form of layers for measurements aimed at the characterization of epithermal neutron beams has been studied. By means of dosimeters of different isotopic composition (standard, containing (10)B or prepared with heavy water) placed against the collimator exit, the spatial distribution of gamma and fast neutron doses and of thermal neutron fluence are attained. In order to investigate the accuracy of the results obtained with in-air measurements, suitable MC simulations have been developed and experimental measurements have been performed utilizing Fricke gel dosimeters, thermoluminescence detectors and activation foils. The studies were related to the epithermal beam designed for BNCT irradiations at the research reactor LVR-15 (Rez). The results of calculation and measurements have revealed good consistency of gamma dose and fast neutron 2D distributions obtained with gel dosimeters in form of layers. In contrast, noticeable modification of thermal neutron fluence is caused by the neutron moderation produced by the dosimeter material. Fricke gel dosimeters in thin cylinders, with diameter not greater than 3mm, have proved to give good results for thermal neutron profiling. For greater accuracy of all results, a better knowledge of the dependence of gel dosimeter sensitivity on radiation LET is needed.


Assuntos
Terapia por Captura de Nêutron/instrumentação , Dosagem Radioterapêutica , Modelos Teóricos , Método de Monte Carlo
20.
Rev Sci Instrum ; 86(7): 073507, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26233383

RESUMO

In an experiment at the laser facility ECLIPSE of the CELIA laboratory, University of Bordeaux, we measure the reflectivity of spherically bent crystals that are commonly used to investigate the propagation of fast electrons through the Kα radiation they generate in matter. The experimental reflectivity compares well with predictions from a ray-tracing code that takes into account the specific geometry, although the crystals seem to suffer from aging problems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA