Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Lett ; 41(24): 5676-5679, 2016 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-27973487

RESUMO

The optical outputs of single-section quantum-dash and quantum-dot mode-locked lasers (MLLs) are well known to exhibit strong group velocity dispersion. Based on careful measurements of the spectral phase of the pulses from these MLLs, we confirm that the difference in group delay between the modes at either end of the MLL spectrum equals the cavity round-trip time. This observation allows us to deduce an empirical formula relating the accumulated dispersion of the output pulse to the spectral extent and free-spectral range of the MLL. We find excellent agreement with previously reported dispersion measurements of both quantum-dash and quantum-dot MLLs over a wide range of operating conditions.

2.
Opt Express ; 23(2): 724-38, 2015 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-25835832

RESUMO

Terabit/s super-channels are likely to become the standard for next-generation optical networks and optical interconnects. A particularly promising approach exploits optical frequency combs for super-channel generation. We show that injection locking of a gain-switched laser diode can be used to generate frequency combs that are particularly well suited for terabit/s super-channel transmission. This approach stands out due to its extraordinary stability and flexibility in tuning both center wavelength and line spacing. We perform a series of transmission experiments using different comb line spacings and modulation formats. Using 9 comb lines and 16QAM signaling, an aggregate line rate (net data rate) of 1.296 Tbit/s (1.109 Tbit/s) is achieved for transmission over 150 km of standard single mode fiber (SSMF) using a spectral bandwidth of 166.5 GHz, which corresponds to a (net) spectral efficiency of 7.8 bit/s/Hz (6.7 bit/s/Hz). The line rate (net data rate) can be boosted to 2.112 Tbit/s (1.867 Tbit/s) for transmission over 300 km of SSMF by using a bandwidth of 300 GHz and QPSK modulation on the weaker carriers. For the reported net data rates and spectral efficiencies, we assume a variable overhead of either 7% or 20% for forward- error correction depending on the individual sub-channel quality after fiber transmission.

3.
Opt Express ; 23(20): 26442-9, 2015 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-26480157

RESUMO

Successful use of a single-section quantum well (QW) passively mode-locked laser (MLL) as a comb source for optical interconnects is demonstrated for the first time. Sixteen comb lines spaced by 37.6 GHz are modulated using 25 Gb/s compatible single sideband orthogonal frequency division multiplexed (SSB-OFDM) signals and transmitted over 50 km of standard single-mode fiber with bit error ratio below the 7% forward error correction limit. The system performance, analyzed on the basis of the relative intensity noise of the device, reveal the suitability of single-section QW MLLs as inexpensive comb sources for inter- and intra-data center communication scenarios.

4.
Appl Opt ; 53(32): 7704-8, 2014 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-25402993

RESUMO

We use the physics of four-wave mixing to study the decorrelation of two optical frequencies as they propagate through different fiber delays. The phase noise relationship between the four-wave mixing components is used to quantify and measure the correlation between the two optical frequencies using the correlation coefficient. We show the difference in the evolution of decorrelation between frequency-dependent and frequency-independent components of phase noise.

5.
Micromachines (Basel) ; 15(4)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38675237

RESUMO

Soft lithography has long remained the state of the art to generate the necessary micropatterning for molded microfluidic (MF) chips. Previous attempts to use printed circuit boards (PCBs) as a cheap and accessible alternative to expensive lithographed molds for the production of PDMS MF chip prototypes have shown their limitations. A more in-depth exploration of using PCBs as a mold substrate and a novel methodology of using flexible PCBs to produce highly accurate MF chips is reported here for the first time. Cross sections highlight the improved accuracy of this method, and peel testing is performed to demonstrate suitable adhesion between the glass substrate and PDMS cast. Positive cell growth viability showcases this novel method as a high-accuracy, high-accessibility, low-cost prototyping method for microfluidic chips while still maintaining all favorable properties provided by the PDMS material.

6.
Opt Express ; 21(13): 15568-79, 2013 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-23842343

RESUMO

We study the effect of transfer of phase noise in different four wave mixing schemes using a coherent phase noise measurement technique. The nature of phase noise transfer from the pump to the generated wavelengths is shown to be independent of the type of phase noise (1 / f or white noise frequency components). We then propose a novel scheme using dual correlated pumps to prevent the increase in phase noise in the conjugate wavelengths. The proposed scheme is experimentally verified by the all-optical wavelength conversion of a DQPSK signal at 10.7 GBaud.

7.
Opt Lett ; 37(9): 1499-501, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22555717

RESUMO

The mode coherence of adjacent and non-adjacent spectral modes of a passively mode locked quantum dash (QDash) semiconductor laser are deduced through radio frequency beat-tone linewidth measurements. A wavelength conversion scheme that uses degenerate four wave mixing in a semiconductor optical amplifier is proposed which considerably extends the mode spacing beyond the limit imposed by conventional fast-photodetection and electrical spectrum analysis of around 100 GHz. Using this scheme, the mode coherence of the QDash laser was measured out to the thirty-first harmonic, or a mode separation of 1.5 THz.

8.
Opt Lett ; 37(23): 4967-9, 2012 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-23202106

RESUMO

This research carries out coherence measurements of a 42.7 GHz quantum dash (QDash) semiconductor laser when passively, electrically, and optically mode-locked. Coherence of the spectral lines from the mode-locked laser is determined by examining the radio frequency beat-tone linewidth as the mode spacing is increased up to 1.1 THz. Electric-field measurements of the QDash laser are also presented, from which a comparison between experimental results and accepted theory for coherence in passively mode-locked lasers has been performed.

9.
Biosens Bioelectron ; 197: 113764, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34753096

RESUMO

Wearable electrochemical sensors are driven by the user-friendly capability of on-site detection of key biomarkers for health management. Despite the advances in biomolecule monitoring such as glucose, still, several unmet clinical challenges need to be addressed. For example, patients suffering from phenylketonuria (PKU) should be able to monitor their phenylalanine (PHE) level in a rapid, decentralized, and affordable manner to avoid high levels of PHE in the body which can lead to a profound and irreversible mental disability. Herein, we report a wearable wristband electrochemical sensor for the monitoring of PHE tackling the necessity of controlling PHE levels in PHE hydroxylase deficiency patients. The proposed electrochemical sensor is based on a screen-printed electrode (SPE) modified with a membrane consisting of Nafion, to avoid interferences in biofluids. The membrane also consists of sodium 1,2-naphthoquinone-4-sulphonate for the in situ derivatization of PHE into an electroactive product, allowing its electrochemical oxidation at the surface of the SPE in alkaline conditions. Importantly, the electrochemical sensor is integrated into a wristband configuration to enhance user interaction and engage the patient with PHE self-monitoring. Besides, a paper-based sampling strategy is designed to alkalinize the real sample without the need for sample pretreatment, and thus simplify the analytical process. Finally, the wearable device is tested for the determination of PHE in saliva and blood serum. The proposed wristband-based sensor is expected to impact the PKU self-monitoring, facilitating the daily lives of PKU patients toward optimal therapy and disease management.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Eletrodos , Humanos , Fenilalanina , Saliva
10.
Brain Sci ; 12(10)2022 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-36291227

RESUMO

To study the biodistribution of new chemical and biological entities, an in vitro model of the blood-brain barrier (BBB) may become an essential tool during early phases of drug discovery. Here, we present a proof-of-concept of an in-house designed three-dimensional BBB biochip designed by us. This three-dimensional dynamic BBB model consists of endothelial cells and astrocytes, co-cultured on opposing sides of a polymer-coated membrane under flow mimicking blood flow. Our results demonstrate a highly effective BBB as evidenced by (i) a 30-fold increase in transendothelial electrical resistance (TEER), (ii) a significantly higher expression of tight junction proteins, and (iii) the low FITC-dextran permeability of our technical solution as compared to a static in vitro BBB model. Importantly, our three-dimensional BBB model effectively expresses P-glycoprotein (Pg-p), a hallmark characteristic for brain-derived endothelial cells. In conclusion, we provide here a complete holistic approach and insight to the whole BBB system, potentially delivering translational significance in the clinical and pharmaceutical arenas.

11.
Med Devices (Auckl) ; 15: 153-161, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35677033

RESUMO

Introduction: The COVID-19 pandemic significantly increased the usage of various types of face masks. In addition, it triggered the rapid manufacture of new production lines of masks to cope with the unprecedented demand to overcome worldwide shortages. Such masks, which were previously used mostly by the health care personnel, became a daily necessity to the greater mainstream population. This rapid and sudden increase in their usage and the fact that new masks' innovations are progressively emerging to meet the growing global shortage requires an ongoing analysis on the factors associated with the fit and comfort while using these masks. Methods: This paper presents the first translation and validation of the R-COMFI questionnaire to evaluate the comfort of a newly developed filtering face-piece respirator by the research team at the University of Antwerp. The questionnaire, which consists of 3 sections: Discomfort, General wearing experience, and Function, was translated from English to Arabic and involved 43 participants in the Lebanese Red Cross healthcare field based in Lebanon. Results: The results showed discomfort factors that are mostly related to breathability and sweating caused by mask usage. Additionally, the results revealed that female respondents found the mask significantly less comfortable than male respondents (p-value with the two-tailed test is 0.0319), which confirmed that future validations should consider the concerns of both genders, and validated the R-COMFI translation exercise detailed in this paper. Discussion: The contribution of this paper can be pinned down into three findings. The first finding is related to the discomfort issues. The second finding highlighted a significant difference in comfort experience between females and males. The last finding is the translation validation of the R-COMFI instrument, which confirmed that the questionnaire can be applied among wider geographical locations.

12.
J Manuf Syst ; 60: 876-892, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33814674

RESUMO

The SARS-CoV-2 pandemic presented European hospitals with chronic shortages of personal protective equipment (PPE) such as surgical masks and respirator masks. Demand outstripped the production capacity of certified European manufacturers of these devices. Hospitals perceived emergency local manufacturing of PPE as an approach to reduce dependence on foreign supply. The fact of a pandemic does not circumvent the hospital's responsibility to provide appropriate protective equipment to their staff, so the emergency production needed to result in devices that were certified by testing agencies. This paper is a case study of the emergency manufacturing of respirator masks during the first month of the first wave of SARS-CoV-2 pandemic and is separated into two distinct phases. Phase A describes the three-panel folding facepiece respirator design, material sourcing, performance testing, and an analysis of the folding facepiece respirator assembly process. Phase B describes the redevelopment of individual steps in the assembly process.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA