Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 96(8): 3402-3408, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38355418

RESUMO

l-Cysteine, distinguished by its possession of reactive sulfhydryl groups within its molecular structure, plays a significant role in both biological systems and the pharmaceutical industry. It stands not only as a natural component integral to the constitution of glutathione but also as the principal precursor for the synthesis of l-cystine through an oxidation reaction. This study endeavors to introduce a novel approach to l-cysteine analysis, capitalizing on its optical activity, whereby an optical rotation detection system grounded in the principles of quantum weak measurement is proffered. The optical rotation angle corresponding to the concentration of chiral solutions can be accurately ascertained through spectral analysis. In practical implementation, a chiral sensing system, boasting a sensitivity of 372 nm/rad, was meticulously constructed, leveraging the concept of weak value amplification. Then, the real-time monitoring of chemical reactions involving l-cysteine and dimethyl sulfoxide was performed. Under the specific experimental conditions outlined in this investigation, it was observed that the oxidation process culminated within approximately 12 h. The application of weak measurement-based chiral sensors holds immense potential, providing robust technical support for real-time monitoring in fields such as chiral analysis and the synthesis of chiral pharmaceutical compounds.

2.
Opt Express ; 30(20): 36839-36848, 2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36258605

RESUMO

A real-time optical phase sensing scheme based on weak value amplification was proposed to monitor the especially binding process of Pertuzumab combined with Trastuzumab on HER2 positive cells. From the wavelength shift of output spectrum, the phase difference between measuring and referential path related to the concentration of Pertuzumab as well as Trastuzumab could be calculated. With this approach, the limit of detection (LOD) of 5.54 × 10-13 M for Pertuzumab assay was achieved. Besides, the kinetics signal of Pertuzumab in combination with Trastuzumab binding to HER2 was detected in real time. Experimental results demonstrated that both Trastuzumab and Pertuzumab can be captured by HER2, but the former was significantly superior to the latter in terms of the target number. Additionally, the binding speed was analyzed and demonstrated to be closely correlated with the initial concentration of the targeting agents.


Assuntos
Técnicas Biossensoriais , Receptor ErbB-2 , Trastuzumab , Receptor ErbB-2/metabolismo , Protocolos de Quimioterapia Combinada Antineoplásica
3.
Opt Express ; 29(19): 30337-30347, 2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34614759

RESUMO

A Mach-Zehnder interferometer system based on weak measurement was set up to determinate the concentration variation of molecule by measuring the phase difference change between the two optical paths. The spectrum of the light was recorded to monitor the concentration of trastuzumab (Herceptin), which is a humanised monoclonal antibody, targeted to human epidermal growth factor receptor 2 (HER2). The trastuzumab targeting to HER2 was real-time detected and continuously monitored, the HER2 numbers of COS7 cells on a coverslip was determined at pico-molar level. Our weak measurement enabled method proposes an alternative approach for the concentration detection of molecules, providing a promising functional tool for the quantification of HER2 in cancer cells, possibly promoting fields such as the diagnosis and treatment of cancer.


Assuntos
Células COS/química , Interferometria/instrumentação , Receptor ErbB-2/metabolismo , Trastuzumab/metabolismo , Algoritmos , Animais , Sítios de Ligação , Chlorocebus aethiops , Desenho de Equipamento , Interferometria/métodos , Receptor ErbB-2/análise , Projetos de Pesquisa , Soroalbumina Bovina , Trastuzumab/análise
4.
Sensors (Basel) ; 21(3)2021 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-33540721

RESUMO

A chiral sensor with optical rotation detection based on weak measurement for the kinetic study of sucrose hydrolysis is presented. Based on the polarization modulation to the pre-selection state, the optical rotation of chiral sample was accurately determined through the central wavelength shift of the output spectrum. With this approach, the concentration response curves of sucrose and its hydrolysis products, i.e., fructose and glucose, were experimentally obtained for the hydrolysis analysis. By collecting the output spectrum with a frequency of 100 Hz and fitting the central wavelength shift synchronously during the measurement, the sucrose hydrolysis process was monitored in real time. Different hydrolysis conditions with varied concentration of invertase enzyme and citrate were implemented in this work. As a consequence, the real-time hydrolysis curves of the hydrolysis process with distinct velocities was achieved and analyzed. Such a kinetic monitoring about sucrose hydrolysis with optical rotation detection technology played a critical role in the researches involving sucrose, and also revealed the great potential of weak measurement in intersections, such as food safety inspection and chemical analysis.

5.
Heliyon ; 8(11): e11754, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36468144

RESUMO

With the structure of biprism, polarization beam splitting in a Glan-Taylor polarizer was explored based on the birefringence and Goos-Hanchen shift. Due to the birefringence of the light in calcite crystal, the extraordinary light worked as the position calibration. As for the ordinary light, the propagated direction tilted noticeably due to the refraction as well as Goos-Hanchen effect at the prism-air interface of in the air gap. The Snell's law and stationary-phase approach were utilized for the calculation of the beam splitting between the two orthogonal polarization elements. By choosing appropriate incident angle and initial polarization, remarkable beam splitting was realized. With this configuration, the resolution with a magnitude of 10 - 5 ° and 10 - 3 ° was achieved for the response of the incident angle and polarization detection respectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA