Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Respiration ; 103(2): 88-94, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38272004

RESUMO

INTRODUCTION: Photon counting (PC) detectors allow a reduction of the radiation dose in CT. Chest X-ray (CXR) is known to have a low sensitivity and specificity for detection of pneumonic infiltrates. The aims were to establish an ultra-low-dose CT (ULD-CT) protocol at a PC-CT with the radiation dose comparable to the dose of a CXR and to evaluate its clinical yield in patients with suspicion of pneumonia. METHODS: A ULD-CT protocol was established with the aim to meet the radiation dose of a CXR. In this retrospective study, all adult patients who received a ULD-CT of the chest with suspected pneumonia were included. Radiation exposure of ULD-CT and CXR was calculated. The clinical significance (new diagnosis, change of therapy, additional findings) and limitations were evaluated by a radiologist and a pulmonologist considering previous CXR and clinical data. RESULTS: Twenty-seven patients (70% male, mean age 68 years) were included. With our ULD-CT protocol, the radiation dose of a CXR could be reached (mean radiation exposure 0.11 mSv). With ULD-CT, the diagnosis changed in 11 patients (41%), there were relevant additional findings in 4 patients (15%), an infiltrate (particularly fungal infiltrate under immunosuppression) could be ruled out with certainty in 10 patients (37%), and the therapy changed in 10 patients (37%). Two patients required an additional CT with contrast medium to rule out a pulmonary embolism or pleural empyema. CONCLUSIONS: With ULD-CT, the radiation dose of a CXR could be reached while the clinical impact is higher with change in diagnosis in 41%.


Assuntos
Pneumonia , Tomografia Computadorizada por Raios X , Adulto , Humanos , Masculino , Idoso , Feminino , Estudos Retrospectivos , Estudos de Viabilidade , Raios X , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Pneumonia/diagnóstico por imagem
2.
Radiology ; 308(1): e230318, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37432088

RESUMO

Background Experience with functional CT in the lungs without additional equipment in clinical routine is limited. Purpose To report initial experience and evaluate the robustness of a modified chest CT protocol and photon-counting CT (PCCT) for comprehensive analysis of pulmonary vasculature, perfusion, ventilation, and morphologic structure in a single examination. Materials and Methods In this retrospective study, consecutive patients with clinically indicated CT for various known and unknown pulmonary function impairment (six subgroups) were included between November 2021 and June 2022. After administration of an intravenous contrast agent, inspiratory PCCT was followed by expiratory PCCT after a delay of 5 minutes. Advanced automated postprocessing was performed, and CT-derived functional parameters were calculated (regional ventilation, perfusion, late contrast enhancement, and CT angiography). Mean intravascular contrast enhancement in the mediastinal vessels and radiation dose were determined. Using analysis of variance, the mean values of lung volumes, attenuation, ventilation, perfusion, and late contrast enhancement were tested for differences between subgroups of patients. Results In 166 patients (mean age, 63.2 years ± 14.2 [SD]; 106 male patients), all CT-derived parameters could be acquired (84.7% success rate; 166 of 196 patients). At the inspiratory examination, mean density was 325 HU in the pulmonary trunk, 260 HU in the left atrium, and 252 HU in the ascending aorta. The mean dose-length product for inspiration and expiration was 110.32 mGy · cm and 109.47 mGy · cm, respectively; the mean CT dose index for inspiration and expiration was 3.22 mGy and 3.09 mGy, respectively (less than the mean total radiation dose of 8-12 mGy, which is diagnostic reference level). Significant differences (P < .05) between the subgroups were found for all assessed parameters. Visual inspection allowed for voxelwise assessment of morphologic structure and function. Conclusion The proposed PCCT protocol allowed for a dose-efficient and robust simultaneous evaluation of pulmonary morphologic structure, ventilation, vasculature, and parenchymal perfusion in a procedure requiring advanced software but no additional hardware. © RSNA, 2023.


Assuntos
Respiração , Tomografia Computadorizada por Raios X , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Artéria Pulmonar , Pulmão/diagnóstico por imagem
3.
J Radiol Prot ; 43(3)2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-37442119

RESUMO

To evaluate the image quality (IQ) of advanced modeled iterative reconstruction (ADMIRE; Siemens Healthcare, Forchheim, Germany) applying image texture and image visual impression as a supplement to physical parameters such as noise level and spatial resolution. An ACR-phantom with four modules was examined at different radiation dose levels. To characterise the image texture, two Haralick texture parameters, contrast and entropy, were assessed at different dose levels and reconstruction algorithms. The visual impression of images and the low-contrast detectability were evaluated by the structural similarity index (SSIM). The spatial resolution was determined by the modulation transfer functions and the line spread function. The Haralick texture parameters, contrast and entropy, decreased with increasing ADMIRE levels. ADMIRE III, IV and V offered a comparable contrast and entropy to those calculated by filtered back projection (FBP) with a radiation dose reduction up to 50%. SSIM (low-contrast detectability) improved with increasing ADMIRE levels. SSIM calculated by ADMIRE IV and V revealed comparable IQ to FBP with a decreased CTDIvolup to 50%. Spatial resolution was retained up to 90% dose reduction. Compared to FBP at the same dose level, the image noise decreased up to 61% with higher ADMIRE levels (σFBP= 17.3 HU andσADMIREV= 10.6 HU at 6.65 mGy). Taking texture analysis and visual perception into account, a more realistic assessment of the dose reduction potential of ADMIRE can be achieved than quality metrics based alone on physical measurements.


Assuntos
Redução da Medicação , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação , Algoritmos , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
4.
Acta Radiol ; 62(12): 1707-1715, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33225716

RESUMO

BACKGROUND: Patients with substantially impaired kidney function and peripheral arterial disease (PAD) underwent comparative CO2-based depiction of the pelvic arteries (PAs). PURPOSE: To evaluate the feasibility and diagnostic performance of CO2-based C-arm computed tomography (CACT) and compare its depiction of PAs with CO2-digital subtraction angiography (DSA). MATERIAL AND METHODS: Fifteen patients (10 men, mean age 70 ± 11 years) with PAD received CO2-DSA and CO2-CACT of the PAs, depicted from the aorta to femoral arteries. These were divided into nine segments (135 in total) and graded by two independent readers for image quality (IQ; 1 = sufficient, 2 = minimal impairments, 3 = insufficient, 4 = outside field of view) and subsequent stenosis grading (SG; grade 1: normal to grade 4: occlusion), under exclusion of all segments with insufficient IQ. Inter-observer and inter-modality agreement calculation and subsequent consensus reading were performed and correlated to a standard of reference (StOR), representing a modality consensus. RESULTS: Of 135 segments, 117 showed sufficient IQ, excluding 18 segments (10 CACT, 8 DSA). Inter-observer agreement for IQ and consecutive SG demonstrated good to excellent agreement: IQDSA: κ = 0.83, IQCACT: κ = 0.76; StenosisDSA: κ = 0.71, StenosisCACT: κ = 0.84. Inter-modality agreement for SG lay at κ = 0.76 and κ = 0.65, respectively. More stenoses could be detected by CACT, and analysis of pooled consensus values of SG in CACTcons versus StOR showed an excellent agreement (κ = 0.96) that proved considerably higher than the moderate agreement between consensus values in DSAcons versus StOR (κ = 0.43). CONCLUSION: CO2-CACT proved feasible, and has the potential to optimize angiographic work-up of PAD in patients with contraindications for other contrast media.


Assuntos
Angiografia Digital/métodos , Artérias/diagnóstico por imagem , Dióxido de Carbono , Pelve/irrigação sanguínea , Doença Arterial Periférica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Constrição Patológica/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
Eur Radiol ; 29(3): 1276-1284, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30209593

RESUMO

AIM: To assess the frequency and severity of complications of balloon pulmonary angioplasty (BPA) using C-arm computed tomography (CACT) guidance. MATERIAL AND METHODS: 266 consecutive interventions in 67 patients (42 females, mean age 66 ± 13 years) were included. Selective CACT was acquired prior to the intervention for three-dimensional (3D) guidance and to select appropriate balloon size based on the measured vessel diameter. Complications during and after the procedure, the need for further interventions and the impact on patient safety and outcome were assessed and categorised according to the SIR Classification System to Complications by Outcome (Grade A-F). RESULTS: Overall, 237 interventions were conducted without any complications (89.1%). Minor complications not requiring additional treatment occurred during or after 25 procedures (9.4%), including recurring dry cough in four patients during a total of 11 interventions (4.1%) (Grade A), three focal dissections of the targeted pulmonary artery (1.1%), four cases of pulmonary haemorrhage (1.5%), one case of reperfusion oedema (0.4%) and six cases of post-interventional short-term hemoptysis (2.3%) (Grade B). Four cases of major complications requiring additional treatment were observed (1.5%): one case of pulmonary haemorrhage (0.4%) and two cases of post-interventional haemoptysis (0.8%), all resolved after medical therapy without requiring further intervention, and one case of atrial tachycardia induced during catheterisation, subsequently requiring pharmacological cardioversion (0.4%) (Grade C). No fatal or life-threatening peri- or post-interventional complications or mortality were observed (Grade D-F). CONCLUSION: BPA performed under CACT guidance appears to be a safe procedure with a low risk of severe complications. KEY POINTS: • CACT guidance of BPA is safe and successful. • CACT-guided BPA procedures have a low complication profile. • CACT guidance is a valuable tool to navigate BPA.


Assuntos
Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Segurança do Paciente/estatística & dados numéricos , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Imageamento Tridimensional/métodos , Pneumopatias/terapia , Masculino , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
6.
Eur Radiol ; 27(10): 4264-4270, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28361177

RESUMO

OBJECTIVE: To evaluate the feasibility of 2D-perfusion angiography (2D-PA) in order to quantify perfusion changes of the lung parenchyma pre- and post-balloon pulmonary angioplasty (BPA). METHODS: Thirty consecutive interventions in 16 patients with 99 treated pulmonary artery segments were included. To quantify changes in pulmonary blood flow using 2D-PA, the acquired digital subtraction angiographies (DSA) pre- and post-BPA were post-processed. A reference ROI in the treated pulmonary artery and a distal target ROI in the lung parenchyma were placed in corresponding areas on DSA pre- and post-BPA. Time to peak (TTP), peak density (PD) and area under the curve (AUC) were assessed. The ratios reference ROI to target ROI (TTPparenchyma/TTPinflow; PDparenchyma/PDinflow; AUCparenchyma/AUCinflow) were calculated. Relative differences of the 2D-PA parameters were correlated to changes in the pulmonary-flow-grade-score. RESULTS: The pulmonary-flow-grade-score improved after BPA (p<0.0001). Likewise, the ratio TTPparenchyma/TTPinflow shortened by 10% (p=0.0002), the PDparenchyma/PDinflow increased by 46% (p<0.0001) and the AUCparenchyma/AUCinflow increased by 36% (p<0.0001). A significant correlation between changes in the pulmonary-flow-grade-score and changes in PDparenchyma/PDinflow (ρ=0.48, p<0.0001) and AUCparenchyma/AUCinflow (ρ=0.31, p=0.0018) was observed. CONCLUSION: Quantification of pulmonary perfusion pre- and post-BPA using 2D-PA is feasible and has the potential to improve monitoring of BPA. KEY POINTS: • Quantification of BPA results by use of 2D-PA is feasible. • 2D-PA allows objective assessment of changes in lung parenchymal perfusion. • 2D-PA has the potential to optimize BPA.


Assuntos
Angiografia Digital/métodos , Angioplastia com Balão/métodos , Hipertensão Pulmonar , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/complicações , Radiografia Intervencionista , Adulto , Idoso , Área Sob a Curva , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/cirurgia , Masculino , Pessoa de Meia-Idade , Perfusão , Estudos Retrospectivos
7.
Invest Radiol ; 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38529924

RESUMO

OBJECTIVES: This phantom and animal pilot study aimed to compare image quality and radiation exposure between detector-dose-driven exposure control (DEC) and contrast-to-noise ratio (CNR)-driven exposure control (CEC) as functions of source-to-image receptor distance (SID) and collimation. MATERIALS AND METHODS: First, an iron foil simulated a guide wire in a stack of polymethyl methacrylate and aluminum plates representing patient thicknesses of 15, 25, and 35 cm. Fluoroscopic images were acquired using 5 SIDs ranging from 100 to 130 cm and 2 collimations (full field of view, collimated field of view: 6 × 6 cm). The iron foil CNRs were calculated, and radiation doses in terms of air kerma rate were obtained and assessed using a multivariate regression. Second, 5 angiographic scenarios were created in 2 anesthetized pigs. Fluoroscopic images were acquired at 2 SIDs (110 and 130 cm) and both collimations. Two blinded experienced readers compared image quality to the reference image using full field of view at an SID of 110 cm. Air kerma rate was obtained and compared using t tests. RESULTS: Using DEC, both CNR and air kerma rate increased significantly at longer SID and collimation below the air kerma rate limit. When using CEC, CNR was significantly less dependent of SID, collimation, and patient thickness. Air kerma rate decreased at longer SID and tighter collimation. After reaching the air kerma rate limit, CEC behaved similarly to DEC. In the animal study using DEC, image quality and air kerma rate increased with longer SID and collimation (P < 0.005). Using CEC, image quality was not significantly different than using longer SID or tighter collimation. Air kerma rate was not significantly different at longer SID but lower using collimation (P = 0.012). CONCLUSIONS: CEC maintains the image quality with varying SID and collimation stricter than DEC, does not increase the air kerma rate at longer SID and reduces it with tighter collimation. After reaching the air kerma rate limit, CEC and DEC perform similarly.

8.
Comput Biol Med ; 154: 106539, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36689856

RESUMO

Model-based reconstruction employing the time separation technique (TST) was found to improve dynamic perfusion imaging of the liver using C-arm cone-beam computed tomography (CBCT). To apply TST using prior knowledge extracted from CT perfusion data, the liver should be accurately segmented from the CT scans. Reconstructions of primary and model-based CBCT data need to be segmented for proper visualisation and interpretation of perfusion maps. This research proposes Turbolift learning, which trains a modified version of the multi-scale Attention UNet on different liver segmentation tasks serially, following the order of the trainings CT, CBCT, CBCT TST - making the previous trainings act as pre-training stages for the subsequent ones - addressing the problem of limited number of datasets for training. For the final task of liver segmentation from CBCT TST, the proposed method achieved an overall Dice scores of 0.874±0.031 and 0.905±0.007 in 6-fold and 4-fold cross-validation experiments, respectively - securing statistically significant improvements over the model, which was trained only for that task. Experiments revealed that Turbolift not only improves the overall performance of the model but also makes it robust against artefacts originating from the embolisation materials and truncation artefacts. Additionally, in-depth analyses confirmed the order of the segmentation tasks. This paper shows the potential of segmenting the liver from CT, CBCT, and CBCT TST, learning from the available limited training data, which can possibly be used in the future for the visualisation and evaluation of the perfusion maps for the treatment evaluation of liver diseases.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada por Raios X , Tomografia Computadorizada de Feixe Cônico/métodos , Artefatos , Fígado/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
9.
Europace ; 14(10): 1441-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22523379

RESUMO

AIMS: Catheter ablation of the pulmonary veins (PVs) is a promising therapeutic approach for symptomatic atrial fibrillation (AF). The prospective randomized single-centre study 'Mesh Ablator versus Cryoballoon Pulmonary Vein Ablation of Symptomatic Paroxysmal Atrial Fibrillation' (MACPAF; clinicaltrials.gov NCT01061931) compared the efficacy and safety of two balloon-based PV ablation systems. METHODS AND RESULTS: Thirty-two patients underwent PV ablation for symptomatic paroxysmal AF using the Arctic Front® or the HD Mesh Ablator® catheter according to study protocol. The primary endpoint was complete PV isolation (PVI) at the end of the ablation procedure, determined by exit block after achieving entrance block. Long-term follow-up data are not included in this publication. Patients' mean age was 61.7 ± 8.9 years, 43.2% were female, and median CHA2DS2-VASc score was 2.0. In the intention-to-treat analysis, the rate of the primary endpoint was 56.5% in patients randomized to the Arctic Front® and 9.5% in patients randomized to the HD Mesh Ablator® catheter (P = 0.001). In the per-protocol analysis, complete PVI was achieved in 13 (76.5%) of 17 Arctic Front® patients but in none of the 15 HD Mesh Ablator® patients (P < 0.0001). There were one major and two minor complications in each study arm but no clinically evident stroke. Post-procedural AF recurrence was detected within hospital stay in two (11.8%) Arctic Front® patients and in seven (46.7%) HD Mesh Ablator® patients (P = 0.049). CONCLUSION: The MACPAF study revealed a superiority of the Arctic Front® catheter concerning complete PVI. Owing to the insufficient efficacy of the HD Mesh Ablator® catheter, the safety board decided to stop MACPAF prematurely.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Idoso , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Recidiva , Telas Cirúrgicas , Resultado do Tratamento
10.
Eur Radiol Exp ; 6(1): 24, 2022 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-35578057

RESUMO

BACKGROUND: The aim of this animal study was to compare the fluoroscopic image quality (IQ) and radiation dose between a tantalum (Ta)-specific contrast-to-noise ratio-driven exposure control (Ta-CEC) and a detector dose-driven exposure control (DEC) in abdominal angiography. METHODS: Nine angiography scenarios were created in seven anaesthetised pigs using Ta-based embolisation material during percutaneous liver and kidney intervention. Fluoroscopic images were acquired using three DEC protocols with different dose levels and Ta-CEC protocols with different IQ levels, sampled in small steps. Polymethyl-methacrylate and aluminium plates were used to simulate attenuation of three water equivalent thicknesses (WET). Three blinded readers evaluated the IQ of DEC and dose equivalent Ta images and selected the Ta-IQ equivalent image corresponding to the DEC image. RESULTS: Interobserver agreement for the IQ assessment was 0.43 for DEC, 0.56 for Ta-CEC and for the assessment of incident air kerma at the interventional reference point (Ka,r) for the Ta-IQ equivalent image 0.73. The average IQ of the dose equivalent Ta images was superior compared to the DEC images (p < 0.001) and also for every WET (26, 31, or 36 cm) and dose level (p ≤ 0.022). The average Ka,r for the Ta-IQ equivalent images was 59 ± 16% (mean ± standard deviation) lower compared to the DEC images (p < 0.001). CONCLUSIONS: Compared to DEC, Ta-CEC significantly improved the fluoroscopic depiction of Ta, while maintaining the Ka,r. Alternatively, the Ka,r can be significantly reduced by using Ta-CEC instead of DEC, while maintaining equivalent IQ.


Assuntos
Angiografia , Tantálio , Angiografia/métodos , Animais , Fluoroscopia , Imagens de Fantasmas , Doses de Radiação , Suínos
11.
Acad Radiol ; 29 Suppl 2: S1-S10, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-32768347

RESUMO

RATIONALE AND OBJECTIVES: To assess the value and possible benefit of combined C-arm computed tomography (CACT) and conventional digital subtraction angiography (DSA) of the pulmonary arteries in the diagnostic work-up of patients with suspected chronic thromboembolic pulmonary hypertension (CTEPH). MATERIALS AND METHODS: We evaluated 308 pulmonary artery angiographies of 308 consecutive patients with suspected CTEPH. Seven patients were excluded because of incomplete imaging. Thus, 301 datasets were included in our study. The pulmonary artery segments and their subsegmental branching were independently evaluated by two readers (R1, R2) using both, DSA and CACT for optimal image quality. Subsequently, the diagnostic findings were compared. Inter-modality and inter-observer agreement were calculated. Consensus reading was done and correlated to a standard of reference, representing the overall consensus of both modalities. Fisher's exact test and Cohen's Kappa were applied. RESULTS: A total of 5719 pulmonary segments were evaluated of which only 28 segments (0.4%) were rated to be nondiagnostic on both, CACT and DSA. Overall, 5640 (98.6%) and 5600 (97.9%) pulmonary segments were rated to be diagnostic in DSA and CACT, respectively. The main causes of nondiagnostic image quality were motion artifacts on both, CACT (R1:81, R2:50) and DSA (R1:60, R2:48). Interobserver agreement was excellent for DSA (κ = 0.9) and CACT (κ = 0.91) and intermodality agreement was substantial (R1: κ = 0.69, R2: κ = 0.77). Compared to standard of reference, the intermodality agreement for CACT was excellent (κ = 0.96), whereas it was inferior for DSA (κ = 0.75), due to the higher number of pathologic findings in CACT read as normal on DSA. CONCLUSION: CACT of the pulmonary arteries can provide additional information to DSA during CTEPH work-up. Moreover, the combination of CACT and DSA can minimize the portion of non-diagnostic examinations, therefore being a reasonable combination to optimize the diagnostic work-up.


Assuntos
Hipertensão Pulmonar , Embolia Pulmonar , Angiografia Digital/métodos , Angiografia por Tomografia Computadorizada , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
12.
Cancer Imaging ; 22(1): 37, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-35908026

RESUMO

BACKGROUND: To evaluate effectivity of a 3D-motion correction algorithm in C-Arm CTs (CACT) with limited image quality (IQ) during transarterial chemoembolization (TACE). METHODS: From 1/2015-5/2021, 644 CACTs were performed in patients during TACE. Of these, 27 CACTs in 26 patients (18 m, 8f; 69.7 years ± 10.7 SD) of limited IQ were included. Post-processing of the original raw-data sets (CACTOrg) included application of a 3D-motion correction algorithm and bone segmentation (CACTMC_no_bone). Four radiologists (R1-4) compared the images by choosing their preferred dataset and recommending repeat acquisition in case of severe IQ-impairment. R1,2 performed additional grading of intrahepatic vessel visualization, presence/extent of movement artifacts, and overall IQ. RESULTS: R1,2 demonstrated excellent interobserver agreement for overall IQ (ICC 0.79,p < 0.01) and the five-point vessel visualization scale before and after post-processing of the datasets (ICC 0.78,p < 0.01). Post-processing caused significant improvement, with overall IQ improving from 2.63 (CACTOrg) to 1.39 (CACTMC_no_bone;p < 0.01) and a decrease in the mean distance of identifiable, subcapsular vessels to the liver capsule by 4 mm (p < 0.01). This proved especially true for datasets with low parenchymal and high hepatic artery contrast. A good interobserver agreement (ICC = 0.73) was recorded concerning the presence of motion artifacts, with significantly less discernible motion after post-processing (CACTOrg:1.31 ± 1.67, CACTMC_no_bone:1.00 ± 1.34, p < 0.01). Of the 27 datasets, ≥ 23 CACTMC_no_bone were preferred, with identical datasets chosen by the readers to show benefit from the algorithm. CONCLUSION: Application of a 3D-motion correction algorithm significantly improved IQ in diagnostically limited CACTs during TACE, with the potential to decrease repeat acquisitions.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Algoritmos , Artefatos , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia
13.
Rofo ; 194(3): 272-280, 2022 03.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-34794186

RESUMO

PURPOSE: Comparison of puncture deviation and puncture duration between computed tomography (CT)- and C-arm CT (CACT)-guided puncture performed by residents in training (RiT). METHODS: In a cohort of 25 RiTs enrolled in a research training program either CT- or CACT-guided puncture was performed on a phantom. Prior to the experiments, the RiT's level of training, experience playing a musical instrument, video games, and ball sports, and self-assessed manual skills and spatial skills were recorded. Each RiT performed two punctures. The first puncture was performed with a transaxial or single angulated needle path and the second with a single or double angulated needle path. Puncture deviation and puncture duration were compared between the procedures and were correlated with the self-assessments. RESULTS: RiTs in both the CT guidance and CACT guidance groups did not differ with respect to radiologic experience (p = 1), angiographic experience (p = 0.415), and number of ultrasound-guided puncture procedures (p = 0.483), CT-guided puncture procedures (p = 0.934), and CACT-guided puncture procedures (p = 0.466). The puncture duration was significantly longer with CT guidance (without navigation tool) than with CACT guidance with navigation software (p < 0.001). There was no significant difference in the puncture duration between the first and second puncture using CT guidance (p = 0.719). However, in the case of CACT, the second puncture was significantly faster (p = 0.006). Puncture deviations were not different between CT-guided and CACT-guided puncture (p = 0.337) and between the first and second puncture of CT-guided and CACT-guided puncture (CT: p = 0.130; CACT: p = 0.391). The self-assessment of manual skills did not correlate with puncture deviation (p = 0.059) and puncture duration (p = 0.158). The self-assessed spatial skills correlated positively with puncture deviation (p = 0.011) but not with puncture duration (p = 0.541). CONCLUSION: The RiTs achieved a puncture deviation that was clinically adequate with respect to their level of training and did not differ between CT-guided and CACT-guided puncture. The puncture duration was shorter when using CACT. CACT guidance with navigation software support has a potentially steeper learning curve. Spatial skills might accelerate the learning of image-guided puncture. KEY POINTS: · The CT-guided and CACT-guided puncture experience of the RiTs selected as part of the program "Researchers for the Future" of the German Roentgen Society was adequate with respect to the level of training.. · Despite the lower collective experience of the RiTs with CACT-guided puncture with navigation software assistance, the learning curve regarding CACT-guided puncture may be faster compared to the CT-guided puncture technique.. · If the needle path is complex, CACT guidance with navigation software assistance might have an advantage over CT guidance.. CITATION FORMAT: · Meine TC, Hinrichs JB, Werncke T et al. Phantom study for comparison between computed tomography- and C-Arm computed tomography-guided puncture applied by residents in radiology. Fortschr Röntgenstr 2022; 194: 272 - 280.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Punções/métodos , Software , Tomografia Computadorizada por Raios X/métodos
14.
Rofo ; 193(4): 417-426, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32882728

RESUMO

PURPOSE: To evaluate the influence of patient alignment and thereby heel effect on the image quality (IQ) of C-arm flat-panel detector computed tomography (CACT). MATERIALS AND METHODS: An ACR phantom placed in opposite directions along the z-axis (setup A and B) on the patient support was imaged using CACT. Image acquisition was performed with three different image acquisition protocols. The images were reconstructed with four convolution kernels. IQ was assessed in terms of high contrast using the modulation transfer function (MTF) and low contrast by assessing the image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR) as well as the reliability of density measurements. Furthermore, the dose intensity profiles were measured free-in-air. RESULTS: The MTF in setup B is higher than the MTF measured in setup A (p < 0.01). The image noises measured in setup A for the air and bone inserts were higher compared to those measured in setup B (p > 0.05). Opposite behavior has been observed for the polyethylene, water-equivalent and acrylic inserts. The SNR for all inserts is inversely related to the image noise. A systematically increasing or decreasing trend of CNR could not be observed (p > 0.05). The intensity profile measured by the detector system free-in-air showed that the anode heel effect is perpendicular to the z-axis. CONCLUSION: The patient alignment has a minor influence on the IQ of CACT. This effect is not based on the X-ray anode heel effect but is caused mainly by the non-symmetrical rotation of CACT. KEY POINTS: · The impact of patient alignment and thereby the heel effect on the image quality of CACT was analyzed.. · The patient alignment has a minor influence on the physical parameters related to image quality, such as noise, SNR, and MTF.. · This effect is based mainly on the non-symmetrical rotation of CACT.. CITATION FORMAT: · Alikhani B, Renne J, Maschke S et al. Impact of Patient Alignment on Image Quality in C-Arm Computed Tomography - Evaluation Using an ACR Phantom. Fortschr Röntgenstr 2021; 193: 417 - 426.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Humanos , Posicionamento do Paciente , Imagens de Fantasmas , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/normas
15.
Front Oncol ; 11: 634389, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33968734

RESUMO

DNA double-strand break (DSB) induction and repair have been widely studied in radiation therapy (RT); however little is known about the impact of very low exposures from repeated computed tomography (CT) scans for the efficiency of repair. In our current study, DSB repair and kinetics were investigated in side-by-side comparison of RT treatment (2 Gy) with repeated diagnostic CT scans (≤20 mGy) in human breast epithelial cell lines and lymphoblastoid cells harboring different mutations in known DNA damage repair proteins. Immunocytochemical analysis of well known DSB markers γH2AX and 53BP1, within 48 h after each treatment, revealed highly correlated numbers of foci and similar appearance/disappearance profiles. The levels of γH2AX and 53BP1 foci after CT scans were up to 30% of those occurring 0.5 h after 2 Gy irradiation. The DNA damage repair after diagnostic CT scans was monitored and quantitatively assessed by both γH2AX and 53BP1 foci in different cell types. Subsequent diagnostic CT scans in 6 and/or 12 weeks intervals resulted in elevated background levels of repair foci, more pronounced in cells that were prone to genomic instability due to mutations in known regulators of DNA damage response (DDR). The levels of persistent foci remained enhanced for up to 6 months. This "memory effect" may reflect a radiation-induced long-term response of cells after low-dose x-ray exposure.

16.
Sci Rep ; 11(1): 20042, 2021 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-34625646

RESUMO

To evaluate mosaic perfusion patterns and vascular lesions in patients with chronic thromboembolic pulmonary hypertension (CTEPH) using C-Arm computed tomography (CACT) compared to computed tomography pulmonary angiography (CTPA). We included 41 patients (18 female; mean age 59.9 ± 18.3 years) with confirmed CTEPH who underwent CACT and CTPA within 21 days (average 5.3 ± 5.2). Two readers (R1; R2) independently evaluated datasets from both imaging techniques for mosaic perfusion patterns and presence of CTEPH-typical vascular lesions. The number of pulmonary arterial segments with typical findings was evaluated and the percentage of affected segments was calculated and categorized: < 25%; 25-49%; 50-75%; < 75% of all pulmonary arterial segments affected by thromboembolic vascular lesions. Inter-observer agreement was calculated for both modalities using the intraclass-correlation-coefficient (ICC). Based on consensus reading the inter-modality agreement (CACTcons vs. CTPAcons) was calculated using the ICC. Inter-observer agreement was excellent for central vascular lesions (ICC > 0.87) and the percentage of affected segments (ICC > 0.76) and good for the perceptibility of mosaic perfusion (ICC > 0.6) and attribution of the pattern of mosaic perfusion (ICC > 0.6) for both readers on CACT and CTPA. Inter-modality agreement was excellent for the perceptibility of mosaic perfusion (ICC = 1), the present perfusion pattern (ICC = 1) and central vascular lesions (ICC = 1). However, inter-modality agreement for the percentage of affected segments was fair (ICC = 0.50), with a greater proportion of identified affected segments on CACTcons. CACT demonstrates a high agreement with CTPA regarding the detection of mosaic perfusion. CACT detects a higher number of peripheral vascular lesions compared to CTPA.


Assuntos
Angiografia/métodos , Hipertensão Pulmonar/patologia , Artéria Pulmonar/patologia , Embolia Pulmonar/patologia , Tomografia Computadorizada por Raios X/métodos , Doença Crônica , Feminino , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Perfusão , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Estudos Retrospectivos
17.
Med Phys ; 48(12): 7641-7656, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34651705

RESUMO

PURPOSE: The first purpose of this phantom study was to verify whether a contrast-to-noise ratio (CNR)-driven exposure control (CEC) can maintain target CNR in angiography more precisely compared to a conventional detector dose-driven exposure control (DEC). The second purpose was to estimate the difference between incident air kerma produced by CEC and DEC when both exposure controls reach the same CNR. METHODS: A standardized 3D-printed phantom with an iron foil and a cavity, filled with iodinated contrast material, was developed to measure CNR using different image acquisition settings. This phantom was placed into a stack of polymethylmethacrylate and aluminum plates, simulating a patient equivalent thickness (PET) of 2.5-40 cm. Images were acquired using fluoroscopy and digital radiography modes with CEC using one image quality level and four image quality gradients and DEC having three different detector dose levels. The spatial frequency weighted CNR and incident air kerma were determined. The differences in incident air kerma between DEC and CEC were estimated. RESULTS: When using DEC, CNR decreased continuously with increasing attenuation, while CEC within physical limits maintained a predefined CNR level. Furthermore, CEC could be parameterized to deliver the CNR as a predefined function of PET. To provide a given CNR level, CEC used equal or lower air kerma than DEC. The mean estimated incident air kerma of CEC compared to DEC was between 3% (PET 20 cm) and 40% (PET 27.5 cm) lower in fluoroscopy and between 1% (PET 20 cm) and 55% (PET 2.5 cm) lower in digital radiography while maintaining CNR. CONCLUSION: Within physical and legislative limits, the CEC allows for a flexible adjustment of the CNR as a function of PET. Thus, the CEC enables task-dependent examination protocols with predefined image quality in order to easier achieve the as low as reasonably achievable principle. CEC required equal or lower incident air kerma than DEC to provide similar CNR, which allows for a substantial reduction of skin radiation dose in these situations.


Assuntos
Angiografia , Intensificação de Imagem Radiográfica , Fluoroscopia , Humanos , Imagens de Fantasmas , Doses de Radiação
18.
Phys Med Biol ; 66(6): 065020, 2021 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-33709957

RESUMO

Conventional detector-dose driven exposure controls (DEC) do not consider the contrasting material of interest in angiography. Considering the latter when choosing the acquisition parameters should allow for optimization of x-ray quality and consecutively lead to a substantial reduction of radiation exposure. Therefore, the impact of a material-specific, contrast-to-noise ratio (CNR) driven exposure control (CEC) compared to DEC on radiation exposure was investigated. A 3D-printed phantom containing iron, tantalum, and platinum foils and cavities, filled with iodine, barium, and gas (carbon dioxide), was developed to measure the CNR. This phantom was placed within a stack of polymethylmethacrylate and aluminum plates simulating a patient equivalent thickness (PET) of 2.5-40 cm. Fluoroscopy and digital radiography (DR) were conducted applying either CEC or three, regular DEC protocols with parameter settings used in abdominal interventions. CEC protocols where chosen to achieve material-specific CNR values similar to those of DEC. Incident air kerma at the reference point(Ka,r), using either CEC or DEC, was assessed and possible Ka,r reduction for similar CNR was estimated. We show that CEC provided similar CNR as DEC at the same or lower Ka,r. When imaging barium, iron, and iodine Ka,r was substantially reduced below a PET of 20 cm and between 25 cm and 30 cm for fluoroscopy and Dr When imaging platinum and tantalum using fluoroscopy and DR and gas using DR, the Ka,r reduction was substantially higher. We estimate the Ka,r reduction for these materials between 15% and 84% for fluoroscopy and DR between 15% and 93% depending on the PET. The results of this study demonstrate a high potential for skin dose reduction in abdominal radiology when using a material-specific CEC compared to DEC. This effect is substantial in imaging materials with higher energy K-edges, which is beneficial, for example, in long-lasting embolization procedures with tantalum-based embolization material in young patients with arterio-venous malformations.


Assuntos
Angiografia/métodos , Meios de Contraste , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Bário , Fluoroscopia/métodos , Humanos , Imageamento Tridimensional/métodos , Iodo , Ferro , Tomografia por Emissão de Pósitrons , Doses de Radiação , Exposição à Radiação , Radiografia , Pele/efeitos da radiação , Raios X
19.
Medicine (Baltimore) ; 100(7): e24783, 2021 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-33607830

RESUMO

ABSTRACT: To evaluate the feasibility and potential value of 2D Parametric Parenchymal Blood Flow (2D-PPBF) for the assessment of perfusion changes following partial spleen embolization (PSE) in a retrospective observational study design.Overall, 12 PSE procedures in 12 patients were included in this study. The outcome of the study was the platelet response (PR), calculated as the percentage increase of platelet count (PLT), following PSE. To quantify perfusion changes using 2D-PPBF, the acquired digital subtraction angiography series were post-processed. A reference region-of-interest (ROI) was placed in the afferent splenic artery and a target ROI was positioned on the embolization territory of the spleen on digital subtraction angiography series pre- and post-embolization. The ratios of the target ROIs to the reference ROIs were calculated for the Wash-In-Rate (WIR), the Time-To-Peak (TTP) and the Area-Under-the-Curve (AUC). Comparisons between pre- and post-embolization data were made using Wilcoxon signed-rank test and Spearman's rank correlation coefficient (r). Afterwards, the study population was divided by the median of the TTP before PSE to analyze its value for the prediction of PR following PSE.Following PSE, PLT increased significantly from 43,000 ±â€Š21,405 platelets/µL to 128,500 ±â€Š66,083 platelets/µL with a PR of 255 ±â€Š243% (P = .003). In the embolized splenic territory, the pre-/post-embolization 2D-PPBF parameter changed significantly: WIRpre-PSE 1.23 ±â€Š2.42/WIRpost-PSE 0.09 ±â€Š0.07; -64 ±â€Š46% (p = 0.04), TTPpre-PSE 4.41 ±â€Š0.99/TTPpost-PSE 5.67 ±â€Š1.52 (P = .041); +34 ±â€Š47% and AUCpost-PSE 0.81 ±â€Š0.85/AUCpost-PSE 0.14 ±â€Š0.08; -71 ±â€Š18% (P = .002). A significant correlation of a 2D-PPBF parameter with the PLT was found for TTPpre-PSE/PLTpre-PSE r = -0.66 (P = .01). Subgroup analysis showed a significantly increased PR for the group with TTPpre-PSE >4.44 compared to the group with TTPpre-PSE ≤4.44 (404 ±â€Š267% versus 107 ±â€Š76%; P = .04).2D-PPBF is an objective approach to analyze the perfusion reduction of embolized splenic tissue. TTP derived from 2D-PPBF has the potential to predict the extent of PR during PSE.


Assuntos
Embolização Terapêutica/métodos , Hiperesplenismo/diagnóstico por imagem , Hipertensão Portal/diagnóstico por imagem , Artéria Esplênica/cirurgia , Adolescente , Adulto , Angiografia Digital/métodos , Embolização Terapêutica/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Hiperesplenismo/etiologia , Hiperesplenismo/cirurgia , Hipertensão Portal/complicações , Hipertensão Portal/cirurgia , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Adulto Jovem
20.
Rofo ; 193(9): 1074-1080, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33634459

RESUMO

PURPOSE: To evaluate the feasibility and image quality of a motion correction algorithm for supra-selective C-arm computed tomography (CACT) of the pulmonary arteries in patients with chronic thromboembolic pulmonary hypertension (CTEPH) undergoing balloon pulmonary angioplasty (BPA). MATERIALS & METHODS: CACT raw data acquired during 30 consecutive BPAs were used for image reconstruction using either standard (CACTorg) or a motion correction algorithm (CACTmc), using 400 iterations. Two readers independently evaluated 188 segmental and 564 sub-segmental contrast-enhanced pulmonary arteries in each reconstruction. The following categories were assessed: Sharpness of the vessel, motion artifacts, delineation of bronchial structures, vessel geometry, and visibility of treatable lesions. The mentioned criteria were rated from grade 1 to grade 3: grade 1: excellent quality; grade 2: good quality; grade 3: poor/seriously impaired quality. Inter-observer agreement was calculated using Cohen's Kappa. Due to an excellent agreement, the ratings of both readers were merged. Differences in the assessed image quality criteria were evaluated using pairwise Wilcoxon signed-rank test. RESULTS: Inter-observer agreement was excellent for all evaluated image quality criteria (κ > 0.81). For all assessed image quality criteria, the ratings on CACTorg were good but improved significantly for CACTmc to excellent for the whole vascular tree (p < 0.01). When considering segmental and sub-segmental levels individually, all image quality criteria improved significantly for CACTmc on both levels (p < 0.01). While ratings of CACTmc were constant for both levels (segmental and sub-segmental) for all criteria, the ratings of CACTorg were slightly impaired for the sub-segmental arteries. CONCLUSION: Motion correction for supra-selective contrast-enhanced CACT of the pulmonary arteries is feasible and improves the overall image quality. KEY POINTS: · Motion artifacts can severely impair the diagnostic accuracy of CACT.. · A motion correction algorithm can significantly improve image quality in CACT of the pulmonary arteries.. · Especially the overall image quality of sub-segmental branches is significantly improved.. CITATION FORMAT: · Maschke S, Werncke T, Becker LS et al. Motion Reduction for C-Arm Computed Tomography of the Pulmonary Arteries: Image Quality of a Motion Correction Algorithm in Patients with Chronic Thromboembolic Hypertension During Balloon Pulmonary Angioplasty. Fortschr Röntgenstr 2021; 193: 1074 - 1080.


Assuntos
Angioplastia com Balão , Hipertensão Pulmonar , Embolia Pulmonar , Algoritmos , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/terapia , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/terapia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA