Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 39(1-2): 275-80, 2005 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-16085143

RESUMO

A 5% (m/m) premix for animal use was quantitatively characterized for the polymorph composition of its benzimidazole drug substance. Raman spectra of reference samples (pure polymorphs A, B and C in lactose at a concentration of 5%, m/m) were compared with the spectra of benzimidazole samples with a known polymorph composition and with the spectra of uncharacterized premixes. The raw intensities of 78 selected wavenumbers were vector-normalized and application of stepwise linear regression models estimated the relative quantities of the benzimidazole-drug polymorphs A, B and C in the different samples. Modelling results of the samples with known polymorph composition were in compliance with the expected concentrations, validating the proposed methodology. The benzimidazole drug substance in the premixes was predominantly polymorph B. Although statistically not significant, some traces of polymorph A could not be ruled out. Similar analyses were performed to evaluate the solid-state stability of the benzimidazole drug substance in another drug formulation, i.e. a suspension-emulsion. Suspension-emulsions originally determined as containing polymorph B benzimidazole drug substance were stored for 12 months at 25 degrees C/60%RH. FT-Raman spectroscopy revealed that no polymorph transformations occurred during this storage.


Assuntos
Benzimidazóis/análise , Benzimidazóis/química , Preparações Farmacêuticas/química , Análise Espectral Raman/métodos , Cristalização , Análise de Fourier
2.
Autoimmunity ; 4(1-2): 51-8, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2491642

RESUMO

A sensitive and highly specific ELISA assay was developed to determine the anti-myosin humoral immune response (AMA) in various heart diseases: acute viral myocarditis, infective endocarditis, acute myocardial infarction, and valve and coronary bypass surgery. The mean study entry AMA titer of each patient group was already significantly increased compared with age matched controls. During further follow-up (90 d) all the groups except for endocarditis showed a significant increase of AMA titer compared with their entry titer. Anti-myosin antibody titer were higher after cardiac surgery than after myocardial infarction or inflammatory heart disease. These results suggest that anti-myosin immune response is not limited to infectious processes in which the pathogen induces antibodies which cross-react with heart constituents but is merely caused by direct cardiac injury. Myosin as a major compound of heart cellular proteins turned out to be a good candidate to trigger immune response after cardiac injury.


Assuntos
Autoanticorpos/sangue , Traumatismos Cardíacos/imunologia , Miosinas/imunologia , Adolescente , Adulto , Idoso , Autoantígenos , Criança , Ponte de Artéria Coronária/efeitos adversos , Reações Cruzadas , Endocardite Bacteriana/imunologia , Feminino , Doenças das Valvas Cardíacas/imunologia , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/imunologia , Miocardite/imunologia
3.
Clin Biochem ; 22(2): 115-9, 1989 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2566398

RESUMO

Lectin affinity chromatography of gamma-glutamyl transferase (GGT,EC 2.3.2.2) is able to detect differences in the carbohydrate moiety of the enzyme. Binding of tissue GGT towards lectins is significantly different from serum GGT, showing increased galactosylation in tissue forms. Kidney GGT is less glycosylated than GGT from other tissues (liver, pancreas, prostate, vesiculae seminales). Increases in sialic acid content of GGT are associated with an increase in the activation energy of the catalyzed reaction. Differences in galactose, fucose and N-acetylhexosamine content induce much smaller effects on activation energy. In liver diseases, serum GGT is characterized by an altered affinity against lectins recognizing galactose, fucose and N-acetyglucosamine and by increased activation energy. In patients with liver disease, use of fixed temperature conversion factors can lead to erroneous calculations of serum GGT enzyme activity (errors up to 13.3%).


Assuntos
Isoenzimas/sangue , Hepatopatias/enzimologia , gama-Glutamiltransferase/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores , Cromatografia de Afinidade , Ensaios Enzimáticos Clínicos , Humanos , Lectinas , Pessoa de Meia-Idade
4.
Clin Chim Acta ; 59(3): 369-72, 1975 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-1126024

RESUMO

Investigations on the high molecular weight isozyme of alkaline phosphatase (R type of AP), which is typically found in the serum of patients with cholestasis, have revealed that AP of the R type corresponds to the conventional liver AP which is attached to vesicular material. The isolation of these vesicles by Sepharose gel filtration is described. Several features were found to be characteristic for these vesicles: 1. The presence of the following enzymes known to be membrane bound: alkaline phosphatase (AP), 5FEET-NUCLEOTIDASE, L-leucyl-beta-naphthylamidase (LAP), and gamma-glutamyl transpeptidase (gamma-GT). 2. The absence of the following enzymes known not to be present on cell membranes: glutamic pyruvic transaminase (SGPT), glutamic oxalacetic transaminase (SGOT), lactate dehydrogenase (LDH), and acid phosphatase. 3. The typical ultrastructural appearance and the cytochemical visualization of alkaline phosphatase and 5feet-nucleotidase. It is concluded that the vesicles correspond to fragments of the liver cell membranes that appear and continue to circulate in the blood of patients with cholestasis.


Assuntos
Membrana Celular/patologia , Hidrolases/sangue , Fígado/enzimologia , Fosfatase Alcalina/sangue , Autoanálise , Colestase/diagnóstico , Colestase/enzimologia , Colestase/patologia , Ensaios Enzimáticos Clínicos , Humanos , Isoenzimas/sangue , Leucil Aminopeptidase/sangue , Fígado/patologia , Nucleotidases/sangue
5.
Clin Chim Acta ; 75(2): 275-85, 1977 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-618370

RESUMO

In this work serum Ig levels were determined daily for 14 days in 12 subjects, every two days for 14 days in 19 subjects, every week for 1 month in 11 subjects and fortnightly in 11 subjects for 6 months. The serum IgG, IgM and IgA levels were quantitated by the linear plate method. The day-to-day reproducibility of the technique was checked for a period of one months on seven different samples. The mean coefficient of variation in the reproducibility experiments was found to be 4.8% for IgG, 8.2% for IgM and 5.2% for IgA. Since the observed variation in all groups of subjects was found to be higher than the methodological variation, it appears that physiological variability occurs in the serum Ig levels of an individual. No difference was found between the physiological variances of IgG, IgM and IgA observed in the group with daily analysis and those with determinations every two days. The physiological variations increase when longer periods are considered between consecutive determinations, but the variability of IgG and IgA in the group with fortnightly determinations is less important than that observed in the group with weekly analyses. Some evidence is presented indicating a periodic fluctuation of serum IgG and IgA levels with an amplitude of nearly 20% and with a recurrence rate of two weeks.


Assuntos
Imunoglobulina A/metabolismo , Imunoglobulina G/metabolismo , Imunoglobulina M/metabolismo , Adolescente , Adulto , Idoso , Análise de Variância , Humanos , Pessoa de Meia-Idade , Periodicidade , Valores de Referência
6.
Clin Chim Acta ; 81(3): 237-45, 1977 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-923096

RESUMO

Human duodenal fluid, secretion fluid of a villous adenoma of the rectum, urine and culture medium of HeLa cells contain plasma membrane fragments which can be revealed by electrophoresis in different media, gel filtration on Sepharose 4-B, electron microscopy and cytochemistry. They carry plasma membrane enzymes (alkaline phosphatase EC 3.1.3.1, leucine aminopeptidase EC 3.4.1.1, 5'-nucleotidase EC 3.1.3.5, maltase EC 3.2.1.20) in the same ratio as the membranes of the cells of origin. Equilibrium density centrifugation results in recovery of these plasma membrane fragments at density 1.190 (g/ml) in CsCl, 1.165 (g/ml) in sucrose, and 1.135 (g/ml) in metrizamide. Similar plasma membrane fragments were decribed previously in the serum of certain liver patients. These observations give evidence that shedding of whole plasma membrane fragments (koinozymic shedding) is a widespread feature of viable cells.


Assuntos
Membrana Celular/ultraestrutura , Idoso , Membrana Celular/enzimologia , Células Cultivadas , Histocitoquímica , Humanos , Masculino , Microscopia Eletrônica , Ultracentrifugação
7.
Clin Chim Acta ; 162(3): 311-8, 1987 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-2882878

RESUMO

The variation of the carbohydrate chain of gamma-glutamyltransferase was studied in 45 liver patients by means of lectin affinity chromatography. Five lectins were used: concanavalin A, Ricinus communis I and II, Maclura pomifera and Ulex europaeus agglutinin. The binding towards Con A was shown to be independent from the binding towards the other lectins. Parallel variations of binding results against the galactose- and fucose-recognizing lectins were obtained. In liver steatosis, the binding results were comparable to those obtained in normal patients. Cirrhosis and metastasis patients showed a decreased binding towards Con A, while the binding against the various galactose- and fucose-recognizing lectins was increased. After neuraminidase treatment, an increased affinity towards all lectins was observed. However, differences in RCA I and RCA II binding between patients and controls still persisted. Besides sialic acid, also galactose and fucose residues contribute to serum gamma-glutamyltransferase heterogeneity.


Assuntos
Cromatografia de Afinidade/métodos , Hepatopatias/enzimologia , gama-Glutamiltransferase/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Concanavalina A/farmacologia , Humanos , Lectinas , Hepatopatias/sangue , Hepatopatias/classificação , Hepatopatias/diagnóstico , Pessoa de Meia-Idade , Neuraminidase/farmacologia , Análise de Regressão
8.
Clin Chim Acta ; 187(2): 115-24, 1990 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-2317930

RESUMO

Low creatine kinase (CK) activities in serum are associated with high fatality rates in intensive care patients. The underlying mechanisms for this phenomenon were investigated. No correlation was found with other biochemical markers of inflammation (CRP, alpha-1 acid glycoprotein, alpha-2 macroglobulin). In the patients' serum a factor is described which is capable of increasing the activation energy of normal CK-MM, indicating molecular changes in CK-structure. This factor is likely to be an enzyme which is present in liver tissue and in fibroblasts. Similar results were obtained after in vitro treatment of normal serum samples with arylsulfatase. Furthermore, bacterial strains isolated in the serum of intensive care patients were found to alter human CK structure. In the investigated patient group, changes in CK activation energy are influenced by serum factors other than carboxypeptidase N activity.


Assuntos
Infecções Bacterianas/enzimologia , Creatina Quinase/metabolismo , Cuidados Críticos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Infecções Bacterianas/sangue , Biomarcadores/análise , Creatina Quinase/sangue , Feminino , Humanos , Concentração de Íons de Hidrogênio , Masculino , Pessoa de Meia-Idade , Temperatura
9.
Ann Clin Biochem ; 25 ( Pt 4): 383-8, 1988 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3214119

RESUMO

In the acute phase of acute myocardial infarction (3-8 h after onset of symptoms) an early transient increase in the creatine concentration of serum, saliva, and especially of urine can be observed. Due to the renal threshold, urine values give a much better discrimination between infarction patients and controls than do serum determination. In some patients secondary peaks of serum and urine creatine concentrations can be seen about 24-36 h after hospital admission. Intramuscular injections of 5.0 mL of a saline solution and muscular trauma interfere with the test, but with angina pectoris interference is absent or limited. Creatine leakage from myocardium is insufficient to explain the observed creatinuria in infarctions, and intact extra-cardiac tissues are believed to be involved in creatine release.


Assuntos
Creatina/análise , Infarto do Miocárdio/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angina Pectoris/sangue , Angina Pectoris/urina , Creatina/sangue , Creatina/urina , Feminino , Humanos , Injeções Intramusculares , Masculino , Pessoa de Meia-Idade , Músculos/análise , Infarto do Miocárdio/sangue , Infarto do Miocárdio/urina , Miocárdio/análise , Valores de Referência , Cloreto de Sódio/administração & dosagem
10.
Comput Methods Programs Biomed ; 50(2): 169-85, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8875023

RESUMO

The OpenLabs coding system is an established, comprehensive, dynamic, flexible, open, multilingual European system which is tailored to meet the electronic data interchange (EDI) needs of medical laboratory users. The OpenLabs coding system, having many specific, independent classes and considerable flexibility, serves two different objectives: (i) unambiguous coding of entities present in messages used for EDI in clinical pathology; and (ii) interfacing with other nomenclatures and coding schemes to map concepts between different systems.


Assuntos
Sistemas de Informação em Laboratório Clínico , Classificação , Redes de Comunicação de Computadores , Sistemas Computacionais , Pesquisa , Semântica , Software , Terminologia como Assunto
17.
Clin Chim Acta ; 13(6): 784, 1966 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-5962606
18.
Hepatology ; 5(1): 118-28, 1985.
Artigo em Inglês | MEDLINE | ID: mdl-3881328

RESUMO

This study presents biochemical, histochemical, morphological and immunological evidence that part of the high molecular weight alkaline phosphatase observed in the serum of patients with liver disease and particularly in cases of intrahepatic cholestasis or focal-, extrahepatic obstruction originates from the liver plasma membrane. The high molecular weight protein alkaline phosphatase complex contains several plasma membrane enzymes and behaves like a plasma membrane fragment after isopycnic density gradient ultracentrifugation in sucrose, cesium chloride and metrizamide. Electron microscopic examination revealed a triple-layered vesicle which retained alkaline phosphatase activity. Incubation of human liver cells with anti-serum against purified high molecular weight multienzyme complex resulted in fixation of antibodies on the plasma membrane as shown by positive plasma membrane fluorescence. These plasma membrane fragments in the serum are not of biliary origin.


Assuntos
Fosfatase Alcalina/sangue , Membrana Celular/enzimologia , Colestase/sangue , Fígado/enzimologia , Adulto , Idoso , Fosfatase Alcalina/análise , Membrana Celular/patologia , Colestase/enzimologia , Colestase/patologia , Feminino , Imunofluorescência , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Peso Molecular
19.
Acta Clin Belg ; 30(1): 9-18, 1975 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27368378

RESUMO

Results of the Belgian proficiency surveys (1971-1973) for clinical chemistry labs are reported. The specific position of this external type of quality control is analyzed. Special attention is given to the detection of systematic factors that could interfere with the introduction of a uniform medical record. A new procedure is described for displaying results grouped according to methods. The difference between the main methods in actual use is of the systematic type rather than a difference in precision. The Youden approach to collaborative tests has been elaborated and generalized by the introduction of correla-tion as an expression of the incidence of systematic factors. The shape of the contour encompassing 95% of the Youden couples, defines a target area often very different from the circular surface expected with uncorrelated results. The participating laboratories, as a group, appeared to work from the beginning according to the current state of the art. Improvement is only possible if basic changes in methods or in calibration are introduced. This suggests a broadening of the activities of the Belgian Society for Quality Control.

20.
Ann Intern Med ; 90(1): 30-5, 1979 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-105655

RESUMO

We studied three patients in whom all or part of their serum alkaline phosphatase circulated as a complex with immunoglobulin G (IgG). Serum alkaline phosphatase isozymes were visualized by their electrophoretic (in agar, agarose, and starch gel and on cellulose acetate), gel filtration, and electroimmunodiffusion behaviour. The alkaline phosphatase-IgG complex was of the liver type (two cases) and bone type (one case). The reaction pattern of alkaline phosphatase with different human tissues and with sera of heterologous origin suggests that the complex is of the antigen-antibody type. A direct genetic mechanism seems unlikely since in one patient the IgG-alkaline phosphatase complex was not present in previous serum samples. The presence of this complex has no apparent correlation with the observed abnormalities. Alkaline phosphatase linked to immunoglobulin G must be considered in the interpretation of increased serum alkaline phosphatase.


Assuntos
Fosfatase Alcalina/sangue , Complexo Antígeno-Anticorpo , Imunoglobulina G , Isoenzimas/sangue , Idoso , Eletroforese em Gel de Ágar , Eletroforese em Gel de Amido , Feminino , Humanos , Imunodifusão , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA