Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Otolaryngol Head Neck Surg ; 171(1): 45-53, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38488229

RESUMO

OBJECTIVE: To compare long-term health-related quality of life (HRQOL) after Transoral Endoscopic Thyroidectomy Vestibular Approach (TOETVA) and transcervical approach (TCA) thyroidectomy. STUDY DESIGN: Prospective cohort study. SETTING: Tertiary referral center. METHODS: A web-based survey was distributed to patients at our institution who met the criteria for TOETVA and underwent thyroidectomy by TOETVA or TCA between August 2017 and October 2021. All survey participants were at least 6 months postsurgery. Minors, non-English speakers, and patients who received concomitant neck dissection or reoperative thyroidectomy were excluded from the study. The survey assessed quality of life through 4 standardized instruments: the Dermatology Life Quality Index (DLQI), the Eating Assessment Tool (EAT-10), the Voice Handicap Index (VHI-10), and the Short Form Health Survey (SF-36). RESULTS: A total of 108 TOETVA and 129 TCA patients were included in the study. The median age of respondents was 44 (36, 54; 25th, 75th percentile) years and median time from surgery to survey was 35 (22, 45; 25th, 75th percentile) months. TOETVA group DLQI (0.63 vs 0.99; P = .17), VHI-10 (1.94 vs 1.67; P = .35), EAT-10 (2.14 vs 2.32; P = .29), SF-36 physical component (52.25 vs 51.00; P = .25), and SF-36 mental component (47.74 vs 47.29; P = .87) scores were all similar to those of the TCA group. Scrutinizing specific DLQI questions, individuals in the TOETVA group were less self-conscious of their skin as compared to the TCA group (Q2; 0.08 vs 0.26, P = .03). CONCLUSION: Long-term HRQOL after TOETVA is similar to TCA, with significantly lower skin-related self-consciousness.


Assuntos
Qualidade de Vida , Tireoidectomia , Humanos , Tireoidectomia/métodos , Masculino , Feminino , Adulto , Estudos Prospectivos , Pessoa de Meia-Idade , Cirurgia Endoscópica por Orifício Natural/métodos , Inquéritos e Questionários
2.
Gland Surg ; 13(2): 236-247, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38455358

RESUMO

Background: Thyroglossal duct cyst (TGDC) is the most common congenital neck mass among the pediatric population. Less than 10% of the cases occur in adults. The standard of care for TGDC is surgical treatment with the Sistrunk procedure via a traditional transverse cervicotomy. This technique involves the resection of the cyst with its tract and the central portion of the hyoid bone body to avoid recurrence. The transoral vestibular approach has gained popularity as an alternative approach to open neck surgery in order to eliminate the transcervical scar associated with these procedures. Methods: We describe a case of an endoscopic Sistrunk procedure performed by the transoral vestibular approach. A scoping review of the transoral endoscopic vestibular approach Sistrunk procedure (TEVAS) was performed. The PubMed, Medline, Cochrane, Lilacs, Scielo, Mary Ann Libert and Scopus databases were systematically searched by using a Medical Subject Heading (MeSH)-optimized search strategy. The selection of papers followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines after setting inclusion and exclusion criteria. Results: The case was successful and without complications. Five studies were included in the final analysis for this review. Conclusions: This novel approach to the Sistrunk procedure is an effective alternative way to treat TGDC in selected patients who are motivated to avoid a visible neck scar.

3.
VideoEndocrinology ; 10(1): 9-10, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38144891

RESUMO

Introduction: Hypoparathyroidism and hypocalcemia are common complications after thyroid surgery. Parathyroids may be incidentally damaged or removed because they are difficult to distinguish from surrounding tissue. Intraoperative optical technologies such as near infrared autofluorescence (NIRAF) are becoming increasingly popular to help identify parathyroids during thyroid surgery. The objective of this video is to introduce a developing NIRAF device called hANDY-i and compare the device with existing Food and Drug Administration approved technology. Materials and Methods: hANDY-i is developed by Optosurgical, LLC. The device consists of a coaxial 785 nm laser excitation module and coregistred red-green-blue and near-infrared cameras. Operation of the device and output from preliminary intraoperative use are shown. Results: hANDY-i performs well, producing intuitive side-by-side NIRAF and RGB images of the operating field. The device demonstrates high contrast between suspected parathyroid glands and surrounding tissue. Operating theater, overhead lamps, and surgical headlights can all be used with the device. The device is also shown to be effective in both in vivo and ex vivo applications. Conclusions: The prototype described advance NIRAF technology by reducing light sensitivity and improving output representation. In doing so, hANDY-i makes NIRAF more accessible and less obstructive to the surgical workflow. Sources of Funding: This study was supported by the National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health under Award Number R43EB030874. Disclaimer: The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.Yoseph Kim is an employee of Optosurgical LLC. Jaepyeong Cha has ownership stake in Optosurgical LLC. For all other authors, no competing financial interests exist.Runtime of video: 7 mins 14 secs.

4.
Front Endocrinol (Lausanne) ; 14: 1190282, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37554762

RESUMO

Introduction: Parathyroid glands may be compromised during thyroid surgery which can lead to hypoparathyroidism and hypocalcemia. Identifying the parathyroid glands relies on the surgeon's experience and the only way to confirm their presence was through tissue biopsy. Near infrared autofluorescence technology offers an opportunity for real-time, non-invasive identification of the parathyroid glands. Methods: We used a new research prototype (hANDY-I) developed by Optosurgical, LLC. It offers coaxial excitation light and a dual-Red Green Blue/Near Infrared sensor that guides anatomical landmarks and can aid in identification of parathyroid glands by showing a combined autofluorescence and colored image simultaneously. Results: We tested the imager during 23 thyroid surgery cases, where initial clinical feasibility data showed that out of 75 parathyroid glands inspected, 71 showed strong autofluorescence signal and were correctly identified (95% accuracy) by the imager. Conclusions: The hANDY-I prototype demonstrated promising results in this feasibility study by aiding in real-time visualization of the parathyroid glands. However, further testing by conducting randomized clinical trials with a bigger sample size is required to study the effect on levels of hypoparathyroidism and hypocalcemia.


Assuntos
Hipocalcemia , Hipoparatireoidismo , Humanos , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Estudos de Viabilidade , Tireoidectomia/efeitos adversos , Tireoidectomia/métodos , Imagem Óptica/métodos , Hipoparatireoidismo/diagnóstico
5.
Front Endocrinol (Lausanne) ; 14: 1233956, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37693365

RESUMO

Background: Treatment options for thyroid pathologies have expanded to include scarless and remote access methods such as the transoral endoscopic thyroidectomy vestibular approach (TOETVA). Currently, no standardized methods exist for locating parathyroid glands (PGs) in patients undergoing TOETVA, which can lead to parathyroid injury and subsequent hypocalcemia. This early feasibility study describes and evaluates the hANDY-i endoscopic attachment for detecting PGs in transoral thyroidectomy. Methods: We used a prototype parathyroid autofluorescence imager (hANDY-i) that was mounted to a 10-mm 0-degree endoscope. The device delivers a split screen view of Red-green-blue (RGB) and near-infrared autofluorescence (NIRAF) which allows for simultaneous anatomical localization and fluorescence visualization of PGs during endoscopic thyroid dissection. Results: One cadaveric case and two patient cases were included in this study. The endoscopic hANDY-i imaging system successfully visualized PGs during all procedures. Conclusion: The ability to leverage parathyroid autofluorescence during TOETVA may lead to improved PG localization and preservation. Further human studies are needed to assess its effect on postoperative hypocalcemia and hypoparathyroidism.


Assuntos
Hipocalcemia , Tireoidectomia , Humanos , Tireoidectomia/efeitos adversos , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Hipocalcemia/diagnóstico , Hipocalcemia/etiologia , Endoscopia Gastrointestinal , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA