Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Neurol Sci ; 41(5): 1193-1199, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31901124

RESUMO

INTRODUCTION: To improve the accuracy of ultrasound techniques for the assessment of carotid stenosis, we designed a novel carotid artery stenosis ultrasound scale (CASUS), and evaluated its accuracy, reliability, and its value in predicting the occurrence of cardiovascular and cerebrovascular diseases in a prospective study. METHODS: A total of 750 patients with first-time ischemic stroke and hospitalized within 24 h were enrolled in the study. Using color Doppler ultrasound (CDUS), the degree of stenosis and blood flow (BF) in bilateral internal carotid arteries (ICA) and the V1-V3 segment of vertebral arteries (VA) was assessed. Cubic simulation curves for BF and global blood flow (GBF) over the stenosis score (SS), total stenosis score (TSS), and radiological imaging- total stenosis score (RI-TSS) were fitted and compared. The receiver operating characteristic (ROC) curves using TSS, RI-TSS, or GBF to predict various ischemic stroke endpoints were also analyzed and compared. RESULTS: There was a linear relationship between SS and BF both ICA and VA (R2 were 0.734 and 0.783, respectively, both P < 0.05). Both TSS and RI-TSS with GBF showed an inverse "S" curve relationship (R2 was 0.839 and 0.843, all P < 0.05). The AUC values of TSS-based and RI-TSS-based predictions of each endpoint were all greater than 0.7 (all P < 0.05), but the differences of the AUC values between TSS, RI-TSS, and GBF were not statistically significant (all P > 0.05). CONCLUSIONS: The novel CASUS can better reflect the level of cerebral reperfusion in patients with ischemic stroke and can better predict the occurrence of cardiovascular and cerebrovascular diseases.


Assuntos
Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , AVC Isquêmico/diagnóstico por imagem , Ultrassonografia Doppler , Artéria Vertebral/diagnóstico por imagem , Idoso , Artéria Carótida Interna/patologia , Feminino , Humanos , AVC Isquêmico/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Artéria Vertebral/patologia
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(8): 2246-50, 2013 Aug.
Artigo em Zh | MEDLINE | ID: mdl-24159886

RESUMO

Longquan celadon not only has been loved widely by the domestic and international ceramic lovers, but also imitated by the kiln workers from different places. Among all of the imitated celadons, the most representative products appeared in Ming and Qing dynasties. This paper used EDXRF to test 38 pieces of Longquan celadon of Song, Yuan and Ming dynasty and imitated Longquan celadon in Jingdezhen of Ming dynasty, combined with firing temperature in order to analyze the different composition characteristics of the bodies and the glaze, evolution rule and formation reasons of these samples in the two different places from the views of time and space. It will be contributed to realising the evolution development, mutual communication and influence of the southern celadon and also provide a scientific basis to get the exact information of the celadon including its time and place of origin and so on.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA