RESUMO
BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.
Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8â mL, P < .001) and cardiac output (0.6 ± 1.2â L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2â m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Masculino , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Índice de Gravidade de DoençaRESUMO
BACKGROUND: Studies comparing plug-based (i.e., MANTA) with suture-based (i.e., ProStar XL and ProGlide) vascular closure devices (VCDs) for large-bore access closure after transcatheter aortic valve replacement (TAVR) have yielded mixed results. AIMS: To examine the comparative safety and efficacy of both types of VCDs among TAVR recipients. METHODS: An electronic database search was performed through March 2022 for studies comparing access-site related vascular complications with plug-based versus suture-based VCDs for large-bore access site closure after transfemoral (TF) TAVR. RESULTS: Ten studies (2 randomized controlled trials [RCTs] and 8 observational studies) with 3113 patients (MANTA = 1358, ProGlide/ProStar XL = 1755) were included. There was no difference between plug-based and suture-based VCD in the incidence of access-site major vascular complications (3.1% vs. 3.3%, odds ratio [OR]: 0.89; 95% confidence interval [CI]: 0.52-1.53). The incidence of VCD failure was lower in plug-based VCD (5.2% vs. 7.1%, OR: 0.64; 95% CI: 0.44-0.91). There was a trend toward a higher incidence of unplanned vascular intervention in plug-based VCD (8.2% vs. 5.9%, OR: 1.35; 95% CI: 0.97-1.89). Length of stay was shorter with MANTA. Subgroup analyses suggested significant interaction based on study designs such that there was higher incidence of access-site vascular complications and bleeding events with plug-based versus suture-based VCD among RCTs. CONCLUSION: In patients undergoing TF-TAVR, large-bore access site closure with plug-based VCD was associated with a similar safety profile as suture-based VCD. However, subgroup analysis showed that plug-based VCD was associated with higher incidence of vascular and bleeding complications in RCTs.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Humanos , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Suturas , Artéria Femoral/cirurgia , Técnicas Hemostáticas , Valva Aórtica/cirurgiaRESUMO
Background: Despite an association between operator volumes and procedural success, there remains an incomplete understanding of the contemporary utilization and procedural volumes for mitral valve transcatheter edge-to-edge repair (MTEER). We aimed to identify annual operator procedural volumes, temporal trends, and geographic variability for MTEER among Medicare patients in the United States (US). Methods: We queried the National Medicare Provider Utilization and Payment Database for a CPT code (33418) specific for MitraClip device from 2015 through 2019. We analyzed annual operator procedural volumes and incidence and identified longitudinal and geographic trends in MTEER utilization. Results: From 2015 through 2019, a total of 27,034 MTEER procedures were performed among Medicare patients in the US. The nationwide incidence increased from 6.2 per 100,000 patients in 2015 to 23.8 per 100,000 patients in 2019, a 283% increase over the study period (Ptrend < 0.001). The incidence of MTEER by state varied by nearly 900% (range 5.5 to 54.9 per 100,000 person-years). In 2019, the mean annual MTEER operator annual volume was 9.1 MTEER procedures and had grown from 6.2 per year in 2015. Conclusions: In this nationwide study of Medicare beneficiaries in the United States, we identified a significant and sustained increase in the utilization of MTEER devices and operators and growth in annual procedural volumes from 2015 through 2019 with considerable variability in utilization by state. Further studies are needed to understand the clinical impact of variability in utilization and the optimal procedural volumes to ensure high efficacy outcomes and maintain critical access to MTEER therapies.
Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Humanos , Estados Unidos/epidemiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Medicare , Insuficiência da Valva Mitral/cirurgia , Cateterismo CardíacoRESUMO
Many novel percutaneous interventions are being developed for application in the tricuspid valve position. At the present time in the United States, there are no commercially available transcathter devices for this application. This article reviews the growing evidence for diagnosing, imaging, and treating severe tricuspid regurgitation as well as the surgical and transcatheter options that are under current development and in various stages of clinical trials.
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Humanos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgiaRESUMO
BACKGROUND: There is a paucity of data on cardiogenic shock (CS) incidence and outcomes among patients with spontaneous coronary artery dissection (SCAD). METHODS: Women admitted to the hospital for acute myocardial infarction (AMI) with and without SCAD were identified from the United States National Readmission Database from October 1, 2015 to December 31, 2018. We calculated the incidence of CS among women with AMI with and without SCAD and odds for developing CS after adjusting for baseline characteristics. In addition, we report the utilization of percutaneous coronary intervention, mechanical circulatory support, severe disability surrogates, and 30-day readmission rates. RESULTS: A total of 664,292 patients admitted for AMI were eligible for analysis, including 6643 patients with SCAD and 657,649 without SCAD. Patients with SCAD were younger (57 years [interquartile range, IQR 48-68] vs. 71 years [IQR 60-81], p < 0.01) and had fewer comorbidities yet had a higher incidence of CS as compared to patients without SCAD (9% vs. 5%, p < 0.01) and remained at elevated risk after adjusting for baseline comorbidities (adjusted odds ratio 1.5 [95% confidence interval, CI 1.2-1.7]). Among patients who developed CS, those with SCAD had lower in-hospital mortality than non-SCAD (31% vs. 39%, p < 0.01), and were more likely to receive mechanical circulatory support. CONCLUSIONS: In a nationally representative sample of women admitted for AMI, we found that patients with SCAD had a higher risk of developing CS and required more frequent use of mechanical circulatory support but were more likely to survive to discharge than women suffering AMI from causes other than SCAD.
Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Anomalias dos Vasos Coronários , Vasos Coronários , Feminino , Humanos , Incidência , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/terapia , Resultado do Tratamento , Estados Unidos/epidemiologia , Doenças Vasculares/congênitoRESUMO
OBJECTIVES: To evaluate transcatheter aortic valve replacement (TAVR) operator procedural volumes, and describe temporal and geographic trends. BACKGROUND: TAVR is the standard of care for most patients with severe symptomatic aortic stenosis. Despite an association between operator procedural volume and outcomes, nationwide TAVR operator volumes have been incompletely described. METHODS: We queried the National Medicare Provider Utilization and Payment Database for transfemoral TAVRs from 2014 to 2018. Annual operator volume, state and regional volumes, and longitudinal trends were extracted and analyzed using descriptive statistics. RESULTS: In 2018, the mean annual operator volume was 23.6 TAVRs. The highest 1% of operators by volume performed 7.6% of total TAVR procedures in the United States, while 35.7% of operators performed 10 or fewer TAVRs per year. From 2014 to 2018, there was a 53.9% annualized increase in TAVRs, and the mean annual volume per operator grew from 12.5 to 23.6. There was more than five-fold variability in the density of operators (range 0.35-1.79 operators per 100,000 population) and mean operator volume by state (range 14.2-52.4 TAVRs per operator). CONCLUSIONS: In this nationally representative study of operators performing transfemoral TAVRs among Medicare patients, we found the mean annual volume of TAVR in 2018 to be 23.6 and has increased since 2014. There was considerable variability in operator density and procedural volumes, with a significant proportion of operators performing 10 or fewer TAVRs per year. Ambiguity remains in regard to the optimal balance of procedural requirements to sustain high efficacy outcomes and ensure critical access to TAVR therapies.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Bases de Dados Factuais , Humanos , Medicare , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estados UnidosRESUMO
OBJECTIVES: The purpose of this study was to characterize the anatomic relationship between the inferior vena cava (IVC) and tricuspid annulus (TA) and its potential impact on the performance of transcatheter TV interventions. BACKGROUND: Transcatheter tricuspid valve (TV) interventions are emerging as a therapeutic alternative for the treatment of severe, symptomatic tricuspid regurgitation (TR). Progression of TR is associated with right heart dilatation. These anatomic changes may distort the IVC-TA relationship and impact successful implantation of transcatheter devices. METHODS: Fifty patients who presented with symptomatic TR for consideration of transcatheter TV therapy with an available CT were included in the study. Comprehensive transesophageal echocardiogram and CT analyses were performed to assess the right-sided cardiac chambers, TA and IVC-TA relationship. RESULTS: The mean age of the study cohort was 78.4 ± 8.9 years. Torrential TR was present in 54% (n = 27). There was considerable variation in the short axis mid-IVC to mid-TA offset (SAXMID 18.2 ± 7.9 mm, range 4.7-42.1 mm). CONCLUSIONS: The IVC-to-TA relationship exhibits significant variability in patients with symptomatic TR. CT analysis of the tricuspid anatomy, including the relationship to the surrounding structures and the IVC, is essential for planning transcatheter TV interventions. Further studies are needed to define whether the IVC-to-TA relationship is a predictor of technical success in the context of specific transcatheter delivery systems.
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Humanos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Veia Cava Inferior/diagnóstico por imagemRESUMO
PURPOSE OF REVIEW: In this review, we have focused on the currently available transcatheter tricuspid valve therapies, device selection, as well as role and management of tricuspid regurgitation (TR) in the setting of other transcatheter valvular procedures. RECENT FINDINGS: In this review, we have enlisted the recently finished as well as ongoing trials in the percutaneous tricuspid valve therapies. TR is highly prevalent yet remains underrecognized and is often untreated. TR has traditionally been managed conservatively with medical therapies including diuretics for volume management, whereas surgical therapies are reserved for those undergoing left-sided valvular surgery. Although the transcatheter devices for tricuspid repair and replacement are in clinical trials, the experience to date for their effectiveness and safety has been reassuring.
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgiaRESUMO
BACKGROUND: Hypoattenuating leaflet thickening (HALT), the radiographic manifestation of transcatheter heart valve thrombosis, is commonly identified following transcatheter aortic valve replacement (TAVR) and associated with increased risk of stroke and structural valve deterioration. While anticoagulation effectively resolves HALT, routine use remains controversial. We aimed to identify hemodynamic, anatomic, and comorbid predictors of HALT. METHODS: We evaluated consecutive patients with severe aortic stenosis who underwent TAVR with Edwards SAPIEN 3 bioprosthesis at a single center between June 1, 2018 and October 30, 2019. Patients on anticoagulation and those receiving valve-in-valve were excluded. Clinically driven computed tomography (CT) imaging was performed to assess for HALT at the discretion of the treating valve team. RESULTS: A total of 78 patients with a mean age of 78 ± 10 years and STS risk score 5.5 ± 3.3% were analyzed. HALT was identified in 11 (14.1%) patients. Compared to controls, those with HALT had smaller annular areas, 435 ± 57 mm2 vs. 489 ± 79 mm2 (p = .032), but received comparable size valves. In multivariate regression, valve oversizing by more than 20% was associated with increased risk of HALT, OR 23.5, 95% CI 2.5-223, (p = .006). After initiation of anticoagulation, patients with HALT had similar rates of stroke, major bleeding, and all-cause mortality out to an average of 243 days. CONCLUSIONS: In this pragmatic study of patients undergoing TAVR with SAPIEN 3 valves, we report the novel finding that oversizing by more than 20% was independently associated with increased risk of HALT. These findings warrant confirmation in larger and prospective trials.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Estudos Prospectivos , Desenho de Prótese , Trombose/diagnóstico por imagem , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
OBJECTIVES: We report the 30-day outcomes from the roll-in cohort of the CLASP IID trial, representing the first procedures performed by each site. BACKGROUND: The currently enrolling CLASP IID/IIF pivotal trial is a multicenter, prospective, randomized trial assessing the safety and effectiveness of the PASCAL transcatheter valve repair system in patients with clinically significant MR. The trial allows for up to three roll-in patients per site. METHODS: Eligibility criteria were: DMR ≥3+, prohibitive surgical risk, and deemed suitable for transcatheter repair by the local heart team. Trial oversight included a central screening committee and echocardiographic core laboratory. The primary safety endpoint was a 30-day composite MAE: cardiovascular mortality, stroke, myocardial infarction (MI), new need for renal replacement therapy, severe bleeding, and non-elective mitral valve re-intervention, adjudicated by an independent clinical events committee. Thirty-day echocardiographic, functional, and quality of life outcomes were assessed. RESULTS: A total of 45 roll-in patients with mean age of 83 years and 69% in NYHA class III/IV were treated. Successful implantation was achieved in 100%. The 30-day composite MAE rate was 8.9% including one cardiovascular death (2.2%) due to severe bleeding from a hemorrhagic stroke, one MI, and no need for re-intervention. MR≤1+ was achieved in 73% and ≤2+ in 98% of patients. 89% of patients were in NYHA class I/II (p < .001) with improvements in 6MWD (30 m; p = .054) and KCCQ (17 points; p < .001). CONCLUSIONS: Early results representing sites with first experience with the PASCAL repair system showed favorable 30-day outcomes in patients with DMR≥3+ at prohibitive surgical risk.
Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Qualidade de Vida , Resultado do TratamentoRESUMO
OBJECTIVES: We sought to evaluate the efficacy and safety of bivalirudin versus heparin in patients with coronary artery disease undergoing transradial artery coronary intervention (TRI). BACKGROUND: Bivalirudin and radial artery access are independently associated with improved cardiovascular outcomes. However, data supporting a strategy of combining both to achieve additive improvements in cardiovascular outcomes provide conflicting results. METHODS: A systematic search was performed to identify randomized controlled trials (RCTs) of bivalirudin, in which vascular access sites were reported. The primary outcome was net adverse clinical events (NACE) at 30 days. Secondary outcomes were long-term NACE, short-, and long-term major adverse cardiovascular events, all-cause mortality, myocardial infarction, unplanned revascularization, stent thrombosis, and major bleeding. RESULTS: We identified 10 RCTs, including 16,328 patients who underwent TRI (mean age 64.6 ± 15.7 years, 72.5% male). Bivalirudin use was associated with decreased 30-day NACE compared with heparin (6.3 vs. 7.4%; risk ratio [RR] = 0.87; 95% confidence interval [CI] = 0.76-0.99; p = .04; number needed to treat = 91). No significant interactions were observed based on clinical presentation, administration of P2Y12 inhibitors, or glycoprotein IIb/IIIa-receptor inhibitors (GPI) use. There were no significant differences between groups in any prespecified secondary outcomes. There was, however, a significant reduction of major bleeding in the bivalirudin group compared with heparin when used in combination with routine GPI (RR = 0.41; 95% CI = 0.19-0.90; p = .03). CONCLUSIONS: Among patients undergoing TRI, use of bivalirudin was associated with significantly reduced 30-day NACE compared with heparin. There was no significant difference in long term NACE, ischemic, or bleeding events compared with heparin.
Assuntos
Anticoagulantes/uso terapêutico , Antitrombinas/uso terapêutico , Cateterismo Periférico , Doença da Artéria Coronariana/terapia , Heparina/uso terapêutico , Fragmentos de Peptídeos/uso terapêutico , Intervenção Coronária Percutânea , Artéria Radial , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Antitrombinas/efeitos adversos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/mortalidade , Trombose Coronária/prevenção & controle , Feminino , Hemorragia/induzido quimicamente , Hemorragia/mortalidade , Heparina/efeitos adversos , Hirudinas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Punções , Ensaios Clínicos Controlados Aleatórios como Assunto , Proteínas Recombinantes/efeitos adversos , Proteínas Recombinantes/uso terapêutico , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
Among patients who have undergone percutaneous coronary intervention (PCI), the use of dual antiplatelet therapy (DAPT) is associated with increased risk of bleeding, but decreased stent thrombosis and myocardial infarction unrelated to the stent. As PCI techniques and devices have progressed, the optimal duration of DAPT has come into question. We identified all randomized controlled trials (RCTs) of patients undergoing PCI, who received one or more drug eluting stents (DES) for stable coronary artery disease (CAD) or acute coronary syndrome (ACS), and randomized to short (1-3 months) versus standard duration DAPT. The prespecified primary outcome was major adverse cardiovascular events (MACE). Important secondary outcomes were net adverse clinical events (NACE) defined as MACE and major bleeding; any bleeding; major bleeding; all-cause death; cardiovascular death. We calculated hazard ratios (HR) and 95% confidence intervals (CI) using random-effects model. Analysis included 7 RCTs, comprising 35,857 patients and 53,321 patient-years of follow-up. The mean (SD) age of patients was 64.4 (10.6) years, 49.6% of patients presented with ACS, and 25.5% were female. There was no difference between short and standard-length DAPT in regards to MACE (HR = 0.93; 95% CI 0.84-1.03; p = 0.19), NACE (HR = 0.93; 95% CI 0.85-1.02; p = 0.12), all-cause death (HR = 0.92; 95% CI 0.80-1.05; p = 0.21), or cardiovascular death (HR = 0.85; 95% CI 0.64-1.13; p = 0.26). However, short-term DAPT was associated with significantly reduced major bleeding events (HR = 0.67; 95% CI 0.47-0.95; p = 0.03) and any bleeding event (HR = 0.63; 95% CI 0.44-0.90; p = 0.01) compared with standard-length DAPT. Among patients undergoing PCI for CAD, the use of short-term DAPT (1-3 months) followed by single antiplatelet therapy was associated with a lower incidence of clinically relevant bleeding events, but with similar risk of MACE, all-cause death, and cardiovascular death compared with standard duration DAPT.
Assuntos
Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Quimioterapia Combinada/métodos , Duração da Terapia , Humanos , Intervenção Coronária Percutânea/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do TratamentoRESUMO
TMVR for degenerative (stenosis and regurgitation) mitral valve prosthesis (valves and rings) results in immediate and sustainable reduction but not normalization of left atrial pressure. Concomitant comorbid conditions such as left ventricular diastolic dysfunction adversely impact left atrial pressure and should be treated. The long-term impact of postprocedural ASD and patient-prosthesis mismatch need to be systematically evaluated so we develop the appropriate data to guide decision making as more transeptal mitral procedures are being performed.
Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Hemodinâmica , Humanos , Valva Mitral/cirurgia , Resultado do TratamentoRESUMO
Transcatheter aortic valve replacement (TAVR) is well-established for the treatment of bioprosthetic aortic valve stenosis (AS) in high surgical risk patients. Coronary artery obstruction from displacement of the bioprosthetic valve leaflets during valve-in-valve (VIV) TAVR is a rare, but potentially fatal, complication. Recently, the bioprosthetic aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) procedure was developed as a method for disrupting bioprosthetic leaflets in patients undergoing VIV TAVR at high risk for coronary obstruction. This case describes a successful VIV TAVR utilizing a simplified concept of the BASILICA technique in a patient where the full procedure could not be completed.
Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese , Estenose Coronária/prevenção & controle , Eletrocoagulação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/fisiopatologia , Estenose Coronária/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
Mitral annular calcification presents a unique challenge to the surgical and interventional management of mitral valve pathology. Herein are presented the details of an emerging use of transcatheter valve replacement not only to salvage an open operation but also to minimize the important late complications of valve migration, resulting in paravalvular leak (PVL). The valve was initially stabilized with balloon valvuloplasty to prevent further migration; a vascular plug was then used to close the PVL. Teams treating complex valvular pathology with transcatheter technologies should be aware of these pitfalls, and be prepared to manage both early and late complications that may arise after transcatheter interventions. Video 1: Paravalvular leak due to atrial migration of the stent frame. Video 2: Resolution of paravalvular leak.
Assuntos
Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Valva Mitral/cirurgia , Falha de Prótese/efeitos adversos , Valvuloplastia com Balão , Calcinose , Cateterismo Cardíaco , Humanos , Valva Mitral/patologiaRESUMO
BVS, as compared with DES, have higher stent thrombosis (ST) rates. BVS may prove reasonable in patients with complex anatomy. Future trials will be necessary to guide clinicians regarding whether BVS are equivalent to DES in patients with noncomplex or complex coronary anatomy.